Liquid Propellant Rocket Engine Control Systems
Liquid Propellant Rocket Engine Control Systems
Liquid Propellant Rocket Engine Control Systems
V Gnanagandhi
Programme Director CSP /LPSC/ISRO TRIVANDRUM
WORKSHOP ON ENGINE CONTROL SYSTEM TECHNOLOGY IIT MUMBAI 19TH NOVEMBER 2004
MONO-PROPELLANT
1N
11N
22N
50N
440N
6.4 KN
7.35 KN
75KN
735KN
GAS GENERATOR
GHe purge valve Ignitor Cavitating Venturi Main Valve Thrust Chamber H2 Injection Valve
By pass Orifice
Vent Line
40 Pressure (bar)
30 Main valve Command Main valve open Bypass valve Open IGNITION 0 H2 valve open 0 0.5 1.0 Time(s) 1.5
20
10
LOX & LH2 FEED SYSTEM CHILLING - LOW FLOW RATE - HIGH FLOW RATE LH2 & LOX TANK PRESSURE GHe SUPPLY FOR FBU PURGE ME & GG USING GHe PURGE SE USING GHe
To-900
To 150 To 150 To + 1
Tf Tf +1 Tf+2.3 +2.3
Tf+10
Tf+10
To - 155 To - 155
LH2 SUPPLY FOR ENGINE UNIT (GG, ME & SE) OPERATE IGNITER OF SE OPERATE IGNITOR OF ME LOX SUPPLY TO SE LOX SUPPLY TO ME OPERATE IGNITOR OF GG LOX SUPPLY FOR GG MOVE THRUST & MRC ACTUATORS TO NOM POSITION
Tf + 2.3
Tf + 2.3 Tf + 2 Tf + 1
Pressure(MPa)
Time (s)
5 MR 4 3
2.5
5.0 Time(s)
7.5
10.0
-50
-100
-150
4
Time(s)
10
20
Acceleration(m/s )
15
Pressure(MPa)
0 262
264
268
270
Typical Engine parameters to be monitored for assessing the health Chamber pressure Coolant channel outlet temperature Turbo pump speed Pump inlet & outlet pressures Gas generator pressure & temperature
AUTO ABORT CONDITIONS FOR HOT TEST TYPICAL CRYOGENIC ENGINE OF PARAMETER
1. a. CHAMBER PRESSURE b. CHAMBER PRESSURE c. LOX INJECTION PRESSURE
ABORT VALUE
NOMINAL VALUE
INTERVAL
PC1 PC2
670K To to Tf 630K
PC1 PC2
< <
POCI-1' <
(2 out of 3)
60
Pressure(bar)
40
Successful test
20
Open loop mode Propellant flow to Gas generator is controlled using fixed area orifices or venturies. Closed loop mode Propellant flow to GG or hot gas flow from GG to turbines is controlled by variable area flow control valves, based on the feed back signal.
Feed back signals for closed loop Mixture Ratio control systems
Onboard computer estimates the mixture ratio using the flow meter and temperature data, which is compared with the desired value and corrected. In propellant utilization control system, the available propellants in the tanks are estimated using level sensors. Modified mixture ratio based on the available propellant is arrived at for the optimum utilization of the propellants and the control valves are adjusted to deplete the propellants simultaneously.
Schematic diagram of GG cycle engine with open loop Thrust & MR control system
Typical Open Loop Thrust/MR Control System for a Cryogenic Rocket Engine
Engine Thrust and Mixture ratio is set to required level by properly sizing the orifices and venturies employed in the propellant feed lines of GG and main Combustion chamber. Control accuracy : +3%
Schematic of SCC engine with closed Loop Thrust and MR control system
Control Electronics
MAJOR SPECIFICATIONS :
FLUID MEDIUM = LOX, FLOW RATE 1.4 KG/SEC, OPERATING PRESSURE = 130 BAR NORMAL OPERATING RANGE = -125 TO +125, MAX: RANGE OF MOVEMENT = -140 TO +140 MAX RESISTANCE TORQUE AT 130 BAR,(NO FLOW CONDITION) = 20 KG CM LEAK RATE OF SHAFT PRIMARY SEL= 50 SCC/MIN,GN2 AT 150 BAR, SECONDARY SEAL=10SCC/MIN,1 BAR
FLOW CHARACTERISTICS
POSITION(DEGRS) WATER FLW RATE,KG/SEC PR : DROP(BAR) TEST RESULT, A0 (BAR) -125 0.46 39.846.8 35.4 38.4 -80 1.26 59.679.9 59.3 77.5 -50 1.26 42.958.1 43.0 45.5 -25 1.26 32.343.2 33.0 35.5 0 1.26 27.127.9 24.6 26.3 25 1.26 15.623 17.4 18.9 50 1.26 9.115.6 10.7 12.0 75 1.26 5.79.1 5.85 6.91 100 1.26 3.85.3 3.23 3.58 125 1.26 2.7-4.1 2.36 1.84
A1
Typical Closed Loop Thrust Control System for a Cryogenic Rocket Engine
Thrust is regulated by controlling the LOX flow to Pre-combustion chamber by a variable area flow control valve, operated by a stepper motor. Using the feed back signal, the thrust control electronics estimates the engine thrust, its deviation from the requirements and command pulses required to nullify the deviation using the thrust control algorithm and actuates the thrust regulator.
START CHAMBER PRESSURE MEASURED [PIO(M)] INPUT SIGNALS IS PIO(L)<PIO(M)<PIO(H) CHAMBER PRESSURE REQUIRED [PIO(R)] NO
PIO(M) PIO(R)
F >D
YES IS F <D1 NO U=Ax
IS
YES
U=A x 1
U <99 YES
NO
U=99xSIGN[U]
1 0.06025[U] = + >0+
NO
U
YES YES
U=
L
( + U)- 0
0.06025
<0- L
NO OUT PUT
( )- 0 U= 0.06025 =
+0.06025*U
6.0
Test result
5.5
Permissible limits
5.0
400
TIME (s)
800
Engine chamber pressure with closed loop control system in a Cryogenic engine hot test
MAJOR SPECIFICATIONS FLUID MEDIUM = LOX, FLOW RATE = 12.8 KG/SEC, OPERATING PR := 130 BAR.
NORMAL RANGE OF OPERATION = -125 TO +125,MAX: RANGE = -140 TO +140 LEAK RT OF PINTLE FORE END SEAL= 2000SCC/MIN AIR AT 100 BAR LEAK RT OF PINTLE REAR END SEAL=1500 SCC/MIN AIR AT 65 BAR MAX REST TORQUE AT NO FLOW, = 20 KGCM
FLOW CHARACTERISTICS
POSITION
WATER,FLOW RATE,KG/SEC PR.DROP
-125
4.97
-80
12.35 8293.9 87.3 88.1
-50
12.35 73.783.7 74.5 79.1
-25
12.35 67.276.7 68.0 72.2
0
12.35 61.269.9 64.1 67.2
25
12.35 55.863.7 59.1 60.0
50
12.35 50.158 52.9 54.9
75
12.35 44.952.4 49.1 49.6
100
12.35 42.743.6 44.2 44.2
125
12.35 34.241.5 38.7 38.8
The MR control electronics estimates the MR and the command pulses required to correct the deviation using the signals from flow meters and temperature sensor. MRC regulator is actuated by a stepper motor to achieve the required mixture ratio.
START
RECEIVED COMMAND 47 YES RECEIVED COMMAND 47-A SIGNAL FROM LOX FLOW METER N01 N02 N 03 , , SIGNAL FROM LH 2 FLOW METER Nf1, Nf2, N f3 NO
NO
NO
YES
L NLIM <N f<N H LIM
NO
Db
b dK = DDb
Da=a-a1/a2 U = -16.6 Da
b S = dK dK+ dK
> K d Km d m YES S=F* d K m 1 U = -S
S
NO d S=F* d m 2 K +F* 1K
b
U > Um YES U < 99 YES a=a +0.06025*U i-1 L a > (a -a reg 0 ) YES a < (a +a 0
H ) reg
NO
U=0
NO
U=99 *sign(U)
NO
U=
NO
YES
i-1
OUT PUT
MR
5.6
Permissible limits
5.5
Test result
5.4
800
Engine mixture ratio with closed loop control system in a Cryogenic engine hot test
1. LH2 temperature change in flight,K 2. LOX temperature change in flight,K 3. LH2 temperature variation during loading, K 4. LOX temperature variation during loading, K 5. LH2 pump inlet pressure variation,bar 6. LOX pump inlet pressure variation,bar 7. Engine tuning error
0.8
0.6
0.4 1.0 Thrust Regulator dThrust/d - constant 0.5 -150 -50 50 Regulator pintle position(Degrees) 0.2
0 150
Typical Closed Loop Thrust Control System for an Earth Storable Rocket Engine
Earth storable engines generally employ pneumo hydraulic/hydraulic systems for Thrust and MR control. The thrust control regulator uses a piston, balanced by the chamber pressure feedback on one side and the required chamber pressure fed as command pressure on the other side. Any unbalance will move the piston thereby varying the propellant flow rate to the gas generator resulting in an increase or decrease of chamber pressure as required.
Typical Closed Loop MR Control System for an Earth Storable Rocket Engine
Since the effect of propellant temperature on MR is negligible, MR is controlled by controlling the thrust chamber inlet pressures. MR control regulator equalizes the oxidizer and fuel pressures at thrust chamber inlet by means of a balancing piston. The required MR is ensured by suitably sizing the calibrated orifice mounted in the propellant line.
4000
LH2 TANK
GAS BOTTLE LH2 PAS RCS THRUSTERS ITT AMBIENT HEL. GAS BOTTLE LOX TANK
UMBILICA L CONNECT OR
LOX PAS
13630
0.700
0.675 Pressure(MPa)
0.600
100 sec
200
300
0.20
0.18 Pressure(MPa)
0.16
0.12
0.10
200
400 Time(s)
600
FUTURE ENDEAVORS
GSLV MKIII PAYLOAD CONFIGURATION LIFT-OFF WEIGHT OVERALL LENGTH 4.5 T 2xS200 + L110 + C25 629 T 40.5 m
G S L V M K II I
L P S C
C-25 STAGE
4000
13630
INSAT
PSLV 1994
C25 STAGE
Ion THRUSTER
8th Plan
9th Plan
10th Plan
TSTO