DataCenter - Overview
DataCenter - Overview
N e x a n s
C a b l i n g
S o l u t i o n s
CENELEC EN 50173-5
Cabling
ISO/IEC 24764
Cabling
ENI (External Network Interface) MD (Main Distributor) ZD (Zone Distributor) LDP (Local Distribution Point) EO (Equipment Outlet)
ENI MD ZD LDP EO
Cat6
Cat6 Class E
Cat6A Class EA
Cat7 Class F Cat7A Class FA
RJ45 - Coax
62,5/125 - 50/125 laser optimized recommended, SM
LC, MPO
LC, MPO
LC, MPO
TIA/EIA 568A
Commercial Building Telecommunications Wiring Standard
EN 50173
ISO/IEC 11801
Generic Cabling for Customer Premises
October 1995
August 1995
July 1995
ISO/IEC 24764
International facilities
Competence Centres
USA UK Belgium
Manufacturing Units
Worldwide
PP
PP PP
PP PP
N e x a n s
C a b l i n g
S o l u t i o n s
LANmark
Copper Cabling Solutions
10
Cablings vs Applications
ISO/IEC 11801:2002 : A1(2008 ) / A2 (2010)
Category Class (Link/Channel) Class D Frequency Bandwidth 100 MHz Connector Type RJ45 Applications Supported 100BASE-T, 1000BASE-T 1000BASE-T, 1000BASE-TX 10GBASE-T 10GBASE-T, future 10G 10GBASE-T, future 40G, hi-bandwidth app Bit rates 100Mbps, 1000Mbps 1000Mbps
CAT5e
CAT6
Class E
250 MHz
RJ45
CAT6A
Class EA
500 MHz
RJ45
10Gbps
CAT7
Class F
600 MHz
GG45
10Gbps
CAT7A
Class FA
1000 MHz
GG45
40Gbps
N e x a n s
C a b l i n g
S o l u t i o n s
11
CAT7A SOLUTIONS
The GG45 connectors are CAT7A connectors, but also backward compatible to legacy CAT5e/ 6/ 6A RJ45.
N e x a n s
C a b l i n g
S o l u t i o n s
12
New Connector
New Cable
LANmark-7A 1500
LANmark-7A Patch Cords based on GG45 V2 Plug
13
N100.371 Upgraded to Cat7A compliance Individually shielded pairs with overall braid screening 7.5mm OD
N100.382 up to 1200 MHz Replaces the old LANmark-7 AWG22 Excellent attenuation performance maintains thin diameter of 7.8mm OD
14
or
2 Pairs on top 2 Pairs on bottom 600 / 1000 MHz 1,2/7,8 and 2 new pairs
15
The GG 45 Interface
16
Shannon Capacity
18
19
20
21
Cables
3x4pair
4x4pair
N e x a n s
6x4pair
C a b l i n g S o l u t i o n s
23
Alan
Bob
Chris
Dave
24
Alien Crosstalk
It is critical to the application. 10GBASE-T is the most sensitive application developed for Copper cabling so far.
It cannot be compensated in equipment. Bit-Error-Rate is set at 10-12 (BER). If failure occurs, transmission may not just degrade, but stop. It is difficult to achieve with UTP Cabling.
26
FTP
27
U/UTP
Construction
U/UTP
(UTP)
C cross copper wire
F/FTP
(FTP)
C cross copper wire Individual Au foil Overal Au foil
outer jacket
outer jacket
F/UTP
(FTP)
outer jacket
S/FTP
(STP)
aluminium foil copper wire braid
outer jacket
28
N e x a n s
C a b l i n g
S o l u t i o n s
29
N e x a n s
C a b l i n g
S o l u t i o n s
30
N e x a n s
C a b l i n g
S o l u t i o n s
31
32
LANmark
Optic Fiber Solutions
33
Core Dia
62.5um
Overfilled Bandwidth 850nm 200 Mhz.km 500 Mhz.km 1500 Mhz.km 3500 Mhz.km
Overfilled Bandwidth 1300nm 500 Mhz.km 500 Mhz.km 500 Mhz.km 500 Mhz.km
1 Gb/s SX
275m
10 Gb/s SR
33m
40 Gb/s SR4
NA
OM2
50um
550m
82m
NA
NA
OM3
50um
550m
300m
100m
100m
OM4
50um
550m
550m
125m
125m
34
FIBER SOLUTIONS
35
LC 2xOM3 LC 2xOM3
LC 2xOM3
LC 2xOM3
LC 2xOM3 LC 2xOM3
Server rack
LC Assemblies for 10G Fabric switch rack Not ready for 40G
LC/LC patchcords
Cross-connect rack
36
40G/100G installation
MPO CORD
MPO CORD
MPO CORD
MPO
MPO
MPO Assemblies for 40G Cabling would need LC Fanouts to run 10G Server rack Fabric switch rack
Cross-connect rack
N e x a n s C a b l i n g S o l u t i o n s
37
Cross-connect rack
38
10 Gigabit Solutions
Install today...
Backbone cabling, Patch Panels, MPO Modules, LC Duplex Patch Cords Horizontal cable Cat6A, patch cord Cat6A
39
40 Gigabit Solutions
40
Smaller tube and better bre arrangement in Micro-Bundle lead to lower skew
41
LANmarkOF UC PE
LANmark-OF UD PE
LANmark-OF ZC LSZH
42
LANmark-OF OM3 and OM4: Fibre cables with high performance multimode fibres for 10, 40 and 100 Gb/s Ethernet LAN applications IEC 60793-1-49: differential mode delay (DMD) to measure effective modal bandwidth (EMB) IEC 60793-1-41: overfilled mode launch bandwidth (OFL BW) ISO/IEC 11801 (2) as OM3 and OM4 fibre
43
Pre-Term FO Assembly Ideal for data center. Quick and easy installation. High loss performance Plug and Play.
Fan-out legs
Protection tube
Grommet
Pulling eye
44
45
46
47
MPO Cassette MPO Connector & Adapter MPO MPO PreTerm trunck cable
48
Pre-Term FO Assembly Ideal for data center. Quick and easy installation. High loss performance Plug and Play.
Fan-out legs
Protection tube
Grommet
Pulling eye
49
Cables management
50
Cables management
51
52
53
54
55
LANsense IIM
56
LANsense topology
57
EMAC/LANsense Integration
58
59
Test
25 YEARS
61
62