Open repository for EU-funded research outputs from Horizon Europe, Euratom and earlier Framework Programmes.
Featured communities
Recent uploads
-
June 27, 2024 (v1)PresentationOpen
All presentations from the ZeroPM event "Special Symposium on the elimination of PFAS from drinking water including a technology demonstration". The event was organized by Stadtwerke Rastatt, TZW (The German Water Centre) and ZeroPM. Experts working on remediation and the PFAS contamination issue at Rastatt came together for a knowledge sharing...
-
June 11, 2024 (v1)DatasetOpen
Microscopic images of discrete samples were acquired using stereo and upright light microscopes and captured on digital cameras. Image files were uploaded along with a brief description and a record of the microscopic and lighting conditions when the image was taken.
-
June 11, 2024 (v1)DatasetOpen
Red, green, and blue pixel data were extracted from Section Half Imaging Logger (SHIL) linescan images, typically binned at 0.5 cm resolution using the central 2 cm of the image.
-
June 11, 2024 (v1)DatasetOpen
Color reflectance data were measured on section halves using an integration sphere and a UV-VIS spectrophotometer mounted on the Section Half Multisensor Logger (SHMSL). Spectral counts are recorded in the range of 380 to 700 nm, covering the visible spectrum, and binned in ~2 nm bins. Spectral data are reduced from spectra and recorded in...
-
June 11, 2024 (v1)DatasetOpen
Report includes detailed information about samples taken for testing: location/depth, type/form factor, test, request number, and database identifier.
-
June 11, 2024 (v1)DatasetOpen
Report includes data for individual core sections: coring/drilling depths and recovery, database identifiers for the whole section and section halves, and number of samples taken from the section before and after splitting.
-
June 11, 2024 (v1)DatasetOpen
Microscopic images of discrete samples were acquired using a scanning electron microscope (SEM) and captured as image files. These files were uploaded along with a brief description and a record of the microscopic conditions when the image was taken.
-
June 11, 2024 (v1)DatasetOpen
Magnetic remanence was measured on discrete samples by an Agico JR-6A spinner magnetometer, first as natural remanent magnetization (NRM) and then after demagnetization or remagnetization steps were performed on the samples (e.g., alternating field [AF] demagnetization, thermal demagnetization [TD], or isothermal remanent magnetization [IRM]).
-
June 11, 2024 (v1)DatasetOpen
Magnetic remanence was measured on section halves (and rarely on whole-round sections) using a 2G Enterprises 760R cryogenic magnetometer, first as natural remanent magnetization (NRM) and then after demagnetization steps were performed on the samples by alternating field (AF) demagnetizer coils mounted in-line within the instrument.
-
June 11, 2024 (v1)DatasetOpen
Thermal conductivity was measured using the heated needle method in either full-space needle configuration (soft/saturated sediments) or half-space needle configuration (harder materials) of a TeKa Berlin TK-04 thermal conductivity meter. Heat is applied to the sample and then thermal equilibrium is sought. The heating and equilibration curve...