Main

Recently, a great deal of attention is devoted to the investigation of thermally excited magnons, particularly in studies of the spin Seebeck effect in YIG (refs 8, 9, 10, 11, 12), for which the relaxation length of magnons was investigated in a local longitudinal spin Seebeck geometry13. Long-distance transport of thermally excited magnons was demonstrated very recently at T = 23 K, using a non-local geometry14. However, thermal excitation is a nonlinear and relatively slow process and does not allow high-fidelity transport and conversion of information. To facilitate magnonic devices operating with a linear response at room temperature, the ideal signal pathway would be: input electronic charge signal → electron spins → magnons → electron spins → output charge signal. Information processing and transport can then be done in the magnon part of the pathway15.

Kajiwara et al.16 reported long-distance transmission of signals in YIG by spin-wave interconversion. However, in their experiment spin waves are excited by exerting a spin transfer torque17,18 (STT) on the magnetization large enough to overcome the intrinsic and interfacial Gilbert damping, driving the sample into ferromagnetic resonance (FMR). The STT was generated by the spin Hall effect (SHE) in a platinum layer, deposited on the YIG. Spin waves generated in this type of experiment typically have frequencies f < 10 GHz (refs 16, 19, 20), much smaller than the thermal energy (hf ≫ kBT), and are hence in the classical regime. Excitation of this type of spin waves by the STT is a highly nonlinear process, where a threshold current density has to be overcome to compensate the damping of the specific spin-wave modes. Their experiments proved difficult to reproduce, but recently Collet et al.have shown that YIG nanostructures can be driven into FMR through the STT (ref. 21). Chumak et al.22 demonstrated long-range low-frequency spin-wave spin transport using radiofrequency magnetic fields to excite spin waves, which were detected by making use of the inverse spin Hall effect (ISHE) in platinum.

Here, we demonstrate for the first time the excitation and detection of high-frequency magnons (that is, quantized spin waves with hf ≈ kBT) through a spin accumulation in a paramagnetic normal metal layer, and their long-distance transport in YIG. Because the spin accumulation can be induced (through the SHE) and detected (through the ISHE) electrically, this method allows full electrical excitation and detection of magnon spin signals in the linear regime and provides a new route towards the development of low-power electronic devices, using magnons rather than electrons for the transport and processing of information.

We study the transport of magnons in a non-local geometry, shown schematically in Fig. 1a. The devices consist of platinum (Pt) strips, deposited on a thin YIG film (see Methods for fabrication details). One Pt strip functions as injector, another as detector (Fig. 1c). When a charge current I is sent through the injector, the SHE generates a transverse spin current. A spin accumulation μs then builds up at the Pt|YIG interface, pointing in the film plane. When the spin orientation of μs is parallel (antiparallel) to the average magnetization M, magnons are annihilated (excited), resulting in a non-equilibrium magnon population nm in the YIG (refs 5, 6, 7; shown schematically in Fig. 1a, b). The non-equilibrium magnons diffuse in the YIG, giving a magnon current jm from injector to detector. At the detector, the reciprocal process occurs: magnons interact at the interface, flipping the spins of electrons and creating a spin imbalance in the platinum (Fig. 1b). Owing to the ISHE, the induced spin current is converted into charge current, which under open-circuit conditions generates a voltage V. The non-local resistance is then Rnl = V/I.

Figure 1: Non-local measurement geometry.
figure 1

a, Schematic representation of the experimental geometry. A charge current I through the left platinum strip (the injector) generates a spin accumulation at the Pt|YIG interface through the spin Hall effect. Through the exchange interaction at the interface, angular momentum is transferred to the YIG, exciting or annihilating magnons. The magnons then diffuse towards the right platinum strip (the detector), where they are absorbed and a spin accumulation is generated. Through the inverse spin Hall effect the spin accumulation is converted to a charge voltage V, which is then measured. b, Schematic of the magnon creation and absorption process. A conduction electron in the platinum scattering off the Pt|YIG interface transfers spin angular momentum to the YIG. This will flip its spin and create a magnon. The reciprocal process occurs for magnon absorption. c, Optical microscope image of a typical device. The parallel vertical lines are the platinum injector and detector, which are contacted by gold leads. Current and voltage connections are indicated schematically. An external magnetic field B is applied at an angle α. The scale bar represents 20 μm.

As only the component of μs collinear to M contributes to magnon injection/detection, we expect to see a dependence of Rnl on the angle α (Fig. 1c) between the sample and an in-plane external magnetic field B that orients M (see Methods). We perform non-local measurements as a function of α by rotating the sample in a fixed external field. Using lock-in amplifiers, we separate higher-order contributions in the voltage by measuring higher harmonics, using: V = R1I + R2I2 + ⋯ , where Ri is the ith harmonic response23. Because magnon spin injection/detection scales linearly with I, its magnitude is obtained from the first harmonic signal. Any thermal effects due to Joule heating (for which ΔT ∝ I2) will be detected in the second harmonic signal. The result of such a measurement is shown in Fig. 2a (2c) for the first (second) harmonic, and the observed angular dependence is explained schematically in Fig. 2b (2d).

Figure 2: Non-local resistance as a function of angle α.
figure 2

a, First harmonic signal. The red line is a cos2α fit through the data. b, Schematic top-view of the experiment. A charge current I through the injector generates a spin accumulation μi at the Pt|YIG interface. The component μ∥ parallel to the net YIG magnetization MY IG generates non-equilibrium magnons in the YIG, which gives rise to a cosα dependence of the injected magnon density. The magnons then diffuse to the detector. At the detector, a spin accumulation μ∥ parallel to MY IG is generated. Owing to the inverse spin Hall effect, μ∥ generates a charge voltage, of which we detect the component generated by μd. This gives rise to a cosα dependence of the detected magnon current. The total signal is a product of the effects at the injector and detector, leading to the cos2α dependence shown in a. c, Second harmonic signal. The red line is a cosα fit through the data. d, Schematic illustration of the angular dependence of the second harmonic: Joule heating at the injector excites magnons thermally, which diffuse to the detector. This process is independent of α. At the detector, the excited magnons generate a spin accumulation antiparallel to the YIG magnetization, which is detected in the same way as for the first harmonic, giving rise to a total cosα dependence. The data shown in a and c are from a device with an injector–detector separation distance of 200 nm and a device length of 12.5 μm, measured at a lock-in frequency f = 9 Hz.

We fabricated two series of devices with different injector–detector separation distances d. Series A is tailored to the short-distance regime (d < 5 μm), whereas series B explores the long-distance regime (3 < d < 50 μm). For each device, a non-local measurement as shown in Fig. 2 was performed. The magnitudes of the non-local resistances were extracted for every d, by fitting the data with

where R01ω and R02ω are offset resistances (see Methods) and Rnl1ω (Rnl2ω) are the magnitudes of the first (second) harmonic signal. Figure 3a and c (3b and d) show the results on linear and logarithmic scales, for the first (second) harmonic non-local resistance, respectively. Both Rnl1ω and Rnl2ω are normalized to device length, to compare devices having different lengths.

Figure 3: Amplitude of the non-local signals as a function of injector–detector separation distance.
figure 3

Every data point represents a device with a different injector–detector separation and results from an angle-dependent measurement as shown in Fig. 2. The magnitude of the signal is extracted by fitting the angle-dependent non-local resistance to equation (1) (2) for the first (second) harmonic. The error bars represent the standard error in the fits. The signal is scaled by device length for both first and second harmonic. a,c, First harmonic data on linear and logarithmic scales, respectively. The dashed line is a fit to equation (5), resulting in λ1ω = 9.4 ± 0.6 μm. For d < λ, the data is described well by a A/d fit, shown in the inset of a. b,d, Second harmonic data on linear and logarithmic scales, respectively. The dashed line is again a fit to equation (5), and we find λ2ω = 8.7 ± 0.8 μm. The inset to b shows the short-distance behaviour of the second harmonic signal. For very short distances, the signal changes sign. For this reason, data points with d < 0.5 μm were omitted from the fit in b and d.

From Fig. 3 we can clearly observe two regimes, which we interpret as follows: at large distances, signal decay is dominated by magnon relaxation and is characterized by exponential decay. For distances shorter than the magnon spin diffusion length we observe diffusive transport, and the signal follows a 1/d behaviour (inset Fig. 3a). Both regimes are described well with a single model, using the one-dimensional spin diffusion equation24,25, adapted for magnon transport:

where nm is the non-equilibrium magnon density, λ is the magnon spin diffusion length in YIG, D is the magnon diffusion constant and τ is the magnon relaxation time. The one-dimensional approach is valid because the YIG thickness (200 nm) is much smaller than the injector–detector distance d, whereas the device length is much larger than d. We assume strong spin–magnon coupling between YIG and platinum, given the large spin-mixing conductance at the Pt|YIG interface26,27 and the strong spin–orbit interaction in platinum. We therefore impose the boundary conditions nm(0) = n0 and nm(d) = 0, where n0 is the injected magnon density, which is proportional to the applied current and is determined by various material and interface parameters. These conditions imply that the injector acts as a low-impedance magnon source, and all magnon current is absorbed when it arrives at the detector. The solution to equation (3) is of the form nm(x) = aexp(−x/λ) + bexp(x/λ), and from the boundary conditions we find for the magnon diffusion current density jm = −D(dnm/dx) at the detector:

The non-local resistance is proportional to jm(d)/n0, and from equation (4) we adopt a two-parameter fitting function for the non-local resistances, capturing the distance-independent prefactors in a single parameter C:

The signal decay described by equation (5) is equivalent to that of spin signals in metallic spin valves with transparent contacts28. The dashed lines shown in Fig. 3a, c are best fits to this function, where we find from the first harmonic data λ1ω = 9.4 ± 0.6 μm. From the second harmonic signal (Fig. 3b, d), originating from magnons generated by heat produced in the injector strip, we find λ2ω = 8.7 ± 0.8 μm. For distances larger than 40 μm, the non-local voltage is smaller than the noise level of our set-up (approximately 3 nVr.m.s.). We compare the magnitude and sign of the signal in the short-distance measurements to a local measurement in Supplementary Section A. From this, we obtain a value for the spin conductivity of YIG, σs ≈ 4 × 105 S m−1, which is comparable to that of metals.

The first and second harmonic signals can be characterized by similar values of λ, indicating that thermally excited magnons are also generated in the close vicinity of the injector. This supports the conclusions drawn in ref. 14—namely, for thermal magnon excitation, the magnon signal reaches far beyond the thermal gradient generated by the applied heating. Note, however, that the sign change for the second harmonic signal (Fig. 3b inset) illustrates that the physics for electrical and thermal magnon generation is very different. This is discussed further in Supplementary Section B.

We verify our assumption of magnon excitation and detection in the linear regime by performing measurements where we reversed the role of injector and detector. The results are shown in Fig. 4a (4b) for the first (second) harmonic. For the first harmonic non-local resistance we find RV –I1ω = 13.28 ± 0.02 mΩ and RI–V1ω = 13.26 ± 0.03 mΩ. As we find RV –I(B) = RI–V(−B) (ref. 29), we conclude that Onsager reciprocity holds within the experimental uncertainty, despite the asymmetry in the injector–detector geometry. Reciprocity does not hold for the second harmonic (Fig. 4b), as expected for nonlinear processes. Finally, we verify that Vnl1ω scales linearly with applied current (Fig. 4c). The linearity and reciprocity of the first harmonic non-local signal demonstrate that it is due to linear processes only.

Figure 4: Demonstration of reciprocity and linearity of the non-local resistance.
figure 4

a, First harmonic signal as a function of angle for the I–V and V–I configurations. We extract the amplitude of the signal using a fit to equation (1), finding RV –I1ω = 13.28 ± 0.024 mΩ and RI–V1ω = 13.26 ± 0.033 mΩ. We thus conclude that reciprocity holds. b, Second harmonic signal as a function of angle. We extract the amplitude of the signal using a fit to equation (2), finding RV –I2ω = 76.3 ± 0.5 V A−2 and RI–V2ω = 132.8 ± 0.5 V A−2. We conclude that reciprocity does not hold for the second harmonic. c, Non-local voltage as a function of injected charge current. The data is obtained from angle-dependent measurements. A data point represents the amplitude of the angle-dependent voltage, obtained by a fit to equation (1). The error bars, representing the standard error in the fit, are also plotted but are smaller than the data points. The red dashed line is a linear fit through the data, showing the linearity of the first harmonic signal. The data shown here is obtained from a device with an injector–detector separation distance of 200 nm and a device length of 12.5 μm, measured at a lock-in frequency f = 5.939 Hz.

Remarkably, the observed magnon transport is described well by the familiar spin diffusion model, despite the completely different character of the carriers of spins in magnetic insulators (bosons) compared to metals and semiconductors (fermions). Our results are consistent with spin injection/detection by invasive contacts, indicating that by optimizing contact properties the signals could be enhanced further. Our observation that the YIG spin conductivity is comparable to that of metals, combined with the long magnon spin diffusion length in YIG, provides new opportunities from a technological point of view to enable novel magnonic devices based on microstructured YIG. The observed similarity between electron and magnon transport begs the question how far this analogy can be extended, and calls for the investigation of effects such as the magnon Hall effect and, possibly, ballistic magnon transport at lower temperatures.

Methods

Fabrication.

The YIG samples of series A consist of a 200 nm (111) single-crystal YIG film grown on a 500 μm (111) Gd3Ga5O12 (GGG) substrate by liquid-phase epitaxy (LPE), provided by the Université de Bretagne Occidentale in Brest, France. YIG samples of series B were obtained commercially from the company Matesy GmbH, and consist of a 210 nm single-crystal (111) Y3Fe5O12 film grown by LPE, also on a GGG substrate. The saturation magnetization MS and Gilbert damping parameter α are comparable for the YIG samples of series A and B, with MSA ∼ 140 kA m−1, αA ∼ 2 × 10−4 and MSB ∼ 144 kA m−1, αB ∼ 1.4 × 10−4. Values of MS were obtained from superconducting quantum inteference device (SQUID) magnetometry measurements, whereas the value for α was determined by means of FMR linewidth measurements (data obtained from N. Vlietstra and J.B.Y. for series A, and from Matesy GmbH for series B). The device pattern was defined using three e-beam lithography steps, each followed by a standard deposition and lift-off procedure. The first step produces a Ti/Au marker pattern, used to align the subsequent steps. The second step defines the platinum injector and detector strips, which were deposited by d.c. sputtering in an Ar+ plasma at an argon pressure of 3.3 × 10−3 mbar. The deposited Pt thickness was approximately 13 nm for series A devices and 7 nm for series B devices, measured by atomic force microscopy. The third step defines 5/75 nm Ti/Au leads and bonding pads, deposited by e-beam evaporation. Before Ti evaporation, argon ion milling was used to remove any polymer residues from the platinum strips, ensuring electrical contact between the platinum and the leads. Devices of series A have an injector/detector length of LA = 7.5 to 12.5 μm and a strip width WA of approximately 100–150 nm. Devices of series B have an injector/detector length of LB = 100 μm and a strip width WB of approximately 300 nm.

Measurements.

All measurements were carried out by means of three SR830 lock-in amplifiers using excitation frequencies ranging from 3 to 40 Hz. The lock-in amplifiers are set up to measure the first, second and third harmonic responses of the sample. Current was sent to the sample using a custom built current source, galvanically isolated from the rest of the measurement equipment. Voltage measurements were made using a custom-built pre-amplifier (gain 103–105) and amplified further using the lock-in systems. The current applied to the sample ranged from 10 to 200 μA (root mean squared). The typical excitation current used is I = 80 μA, which results in a charge current density of jc ≈ 1010 A m−2, depending on the specific device geometry. The in-plane coercive field of the YIG is Bc < 1 mT for both YIG samples, and we apply an external field to orient the magnetization (typically Bext = 5 mT) using a GMW electromagnet. The sample was rotated with respect to the magnet poles using a rotatable sample holder with stepper motor. The offset resistances R01ω and R02ω described in equations (1) and (2) depend on the capacitive and inductive coupling between the measurement wires to and from the sample, and vanish for low excitation frequencies (typically when Flock−in < 5 Hz).