To compare research grading of diabetic retinopathy (DR) severity level from compressed digital i... more To compare research grading of diabetic retinopathy (DR) severity level from compressed digital images versus uncompressed images and film. Compressed (JPEG2000, 37:1) digital images (C) were compared with uncompressed digital (U) and film (F) stereoscopic photographs from a 152-eye cohort with full-spectrum Early Treatment Diabetic Retinopathy Study severity levels for agreement on severity level, DR presence with ascending severity threshold, presence of DR index lesions, and repeatability of grading. Classification of Early Treatment Diabetic Retinopathy Study severity levels from C images agreed substantially with results from F images (κ = 0.60, κ(w) [linear weighted] = 0.86) and uncompressed digital images (κ = 0.76, κ(w) = 0.92). For agreement of uncompressed digital versus F images, κ = 0.62 and κ(w) = 0.86. Distribution of Early Treatment Diabetic Retinopathy Study levels was not significantly different between C and F images (P = 0.09, Bhapkar's test for marginal homogeneity). For presence/absence of DR at 8 ascending severity thresholds, agreement between C and F was "almost perfect" (κ ≥ 0.8). Agreement on severity level between readers with C images was at least as good as that with uncompressed digital image or F. Repeatability of severity threshold grading between readers was similar using C or F images. For identifying individual DR lesions, agreement between C and F ranged from "moderate" to "perfect." Agreement of grading venous beading from C was slightly lower than from F. Full Early Treatment Diabetic Retinopathy Study scale DR severity level grading using C images is comparable to that using U images or film.
To evaluate digital photography parameters affecting comparability with the Early Treatment Diabe... more To evaluate digital photography parameters affecting comparability with the Early Treatment Diabetic Retinopathy Study (ETDRS) film protocol for diabetic retinopathy (DR) severity grading. ETDRS protocol photographs and four variations of digital images (uncompressed stereoscopic, compressed stereoscopic, uncompressed monoscopic, and uncompressed monoscopic wide-angle mosaic) of 152 eyes were independently evaluated by using ETDRS classifications. Digital formats were compared to film and each other for agreement on severity level, DR presence at ascending threshold, presence of the DR index lesion, and repeatability of grading. Study parameters included image resolution sufficient to distinguish small lesions, color balancing of digital images to film, documenting essential ETDRS classification retinal regions, similar magnification, and supplementary green-channel viewing. The κ statistic was substantial or near substantial between all digital formats and film for classifying severity levels (κ = 0.59-0.62; κ(w) [linear weighted] = 0.83-0.87). The distribution of DR levels in all digital formats was not significantly different from that of the film (Bhapkar test, P = 0.09-0.44). The κ among digital formats for severity level was also substantial or near substantial (κ = 0.58-0.76, κ(w) = 0.82-0.92). Differences between digital formats and film for grading severity level, severity threshold, or index lesions were not significant. The repeatability of grading between readers using film and all digital formats was also similar. Digital format variations compared favorably with film for DR classification. Translating film characteristics (resolution, color/contrast) and protocol (magnification, retinal regions) to digital equivalents and augmentation of full color with green-channel viewing most likely contributed to the results.
To assess agreement between digital and film photography for research classification of diabetic ... more To assess agreement between digital and film photography for research classification of diabetic retinopathy severity. Digital and film photographs from a 152-eye cohort with a full spectrum of Early Treatment Diabetic Retinopathy Study (ETDRS) severity levels were assessed for repeatability of grading within each image medium and for agreement on ETDRS discrete severity levels, ascending severity thresholds, and presence or absence of diabetic retinopathy index lesions, between digital and 35-mm slides (film). Digital photographs were color balanced to match film. There was substantial agreement (κ = 0.61, κ(w) [linear weighted] = 0.87) in classification of ETDRS diabetic retinopathy severity levels between digital images and film. Marginal homogeneity analyses found no significant difference in frequency distributions on the severity scale (P = 0.21, Bhapkar test). The κ results ranged from 0.72 to 0.95 for presence or absence of eight ascending diabetic retinopathy severity thresholds. Repeatability of grading between readers viewing digital images was equal to or better than that obtained with film (pair-wise interreader κ for digital images ranged from 0.47 to 0.57 and for film from 0.43 to 0.57. The κ results for identifying diabetic retinopathy lesions ranged from moderate to almost perfect. Moderate agreement of intraretinal microvascular abnormalities and venous beading between digital images and film accounted for slightly lower concordance for severity thresholds ≥47 and for slightly lower interreader agreement within digital and film images at severity thresholds ≥43 and ≥47. Under controlled circumstances, digital photography can equal the reliability of 35-mm slides for research classification of ETDRS severity level.
To assess agreement between monoscopic and stereoscopic photography for research classification o... more To assess agreement between monoscopic and stereoscopic photography for research classification of the severity of diabetic retinopathy (DR). Monoscopic digital (MD) images were compared with stereo digital (SD) and film (SF) photographs from a 152-eye cohort with full-spectrum Early Treatment Diabetic Retinopathy Study (ETDRS) severity levels for agreement on severity level, DR presence with ascending severity threshold, presence of DR index lesions, and repeatability of grading. There was substantial agreement classifying ETDRS DR severity levels between MD and SF (kappa = 0.65, kappa(w) [linear weighted] = 0.87), MD and SD (kappa = 0.66, kappa(w) = 0.87), and SD and SF (kappa = 0.62, kappa(w) = 0.86) images. Marginal homogeneity analyses found no significant difference between MD and SF images (P = 0.53, Bhapkar test). The kappa agreement between MD and SF ranged from 0.80 to 0.94 for the presence or absence of eight ascending DR severity thresholds. Repeatability between the readers of the MD images was equal to or better than that of the readers of SD or SF images. Severity threshold grading repeatability between readers was similar with the MD and SF images. The kappa agreement between MD and SF for identifying diabetic retinopathy lesions ranged from moderate to almost perfect. The kappa comparisons showed that performance of grading new vessels on the disc in MD images was slightly lower than that with the SF images. Monoscopic photography can equal the reliability of stereo photography for full ETDRS DR severity scale grading.
To assess agreement between evaluations of monoscopic and stereoscopic digital images versus ster... more To assess agreement between evaluations of monoscopic and stereoscopic digital images versus stereo film photographs in diabetic macular edema (DME). A 152-eye group of digital monoscopic macular images (seven-field sets and wide-angle mosaics) were compared with digital stereoscopic images (uncompressed and compressed seven-field sets) and stereo 35-mm film photos (Early Treatment Diabetic Retinopathy Study protocol) for the presence of hard exudates (HE), retinal thickening (RT), clinically significant macular edema (CSME), and RT at the center of the macular (RTCM). Agreement, according to the κ statistic, was almost perfect in identifying HE and RT between all digital formats and stereo film (HE, κ = 0.81-0.87; RT, κ = 0.87-0.92). Distribution in all digital formats was not significantly different from that in film (Bhapkar test: HE, P = 0.20-0.40; RT, P = 0.06-1.0). CSME and RTCM grading differences were either significant or trended toward significance. The readers detected CSME and RTCM in film images more often than in digital formats. In identifying DME features, agreement between evaluations of monoscopic digital formats and film was similar to that between stereo digital formats and film, and the performance of uncompressed images versus film was similar to that of compressed images versus film. Repeatability between readers was similar in evaluations of film and all digital formats. Repeatability in identifying RTCM was lower than that of other DME components in film and all digital formats. Stereoscopic digital formats are equivalent to monoscopic for DME evaluation, but digital photography is not as sensitive as film in detecting CSME and RTCM.
A number of studies have demonstrated that radiologists can become fatigued after reading cases f... more A number of studies have demonstrated that radiologists can become fatigued after reading cases for a number of hours. Some of these studies have demonstrated that there are associated decreases in observer performance (i.e., reduced accuracy), but mammographic reading has not been a focus of any of these studies. Based on these recent findings regarding decreases in performance as a
Two decades have passed since the publication of laboratory studies of satisfaction of search (SO... more Two decades have passed since the publication of laboratory studies of satisfaction of search (SOS) in chest radiography. Those studies were performed using film. The current investigation tests for SOS effects in computed radiography of the chest. Sixty-four chest computed radiographs half demonstrating various "test" abnormalities were read twice by 20 radiologists, once with and once without the addition of a simulated pulmonary nodule. Receiver-operating characteristic detection accuracy and decision thresholds were analyzed to study the effects of adding the nodule on detecting the test abnormalities. Results of previous studies were reanalyzed using similar modern techniques. In the present study, adding nodules did not influence detection accuracy for the other abnormalities (P = .93), but did induce a reluctance to report them (P < .001). Adding nodules did not affect inspection time (P = .58) so the reluctance to report was not associated with reduced search. R...
Telemedicine journal and e-health : the official journal of the American Telemedicine Association, Jan 28, 2015
Telemedicine is used with increasing frequency to improve patient care in remote areas. The inter... more Telemedicine is used with increasing frequency to improve patient care in remote areas. The interpretation of medical imaging on iPad(®) (Apple, Cupertino, CA) tablets has been reported to be accurate. There are no studies on the use of iPads for interpretation of pediatric echocardiograms. We compared the quality of echo images, diagnostic accuracy, and review time using three different modalities: remote access on an iPad Air (iPad), remote access via a computer (Remote), and direct access on a computer linked through Ethernet to the server, the "gold standard" (Direct). Fifty consecutive archived pediatric echocardiograms were interpreted using the three modalities. Studies were analyzed blindly by three pediatric cardiologists; review time, diagnostic accuracy, and image quality were documented. Diagnostic accuracy was assessed by comparing the study diagnoses with the official diagnosis in the patient's chart. Discrepancies between diagnoses were graded as major (...
Journal of the American Academy of Audiology, 2015
Health care is being fundamentally changed by telemedicine. Telemedicine uses communication techn... more Health care is being fundamentally changed by telemedicine. Telemedicine uses communication technologies in prevention, disease management, home health care, long-term (chronic) care, emergency medicine, and many other applications including audiology. Telemedicine is being adopted and integrated into the health care enterprise at an exponential rate and it is often difficult to keep up with all of these changes. Other key drivers such as the Affordable Care Act and other federal health care initiatives are pushing the adoption of telemedicine and catalyzing a flood of interest in telemedicine, telehealth, and m-Health. This paper provides an overview of telehealth models and will describe methodologies as they pertain to clinical practice. The goal is to provide the principles behind the practice of telemedicine and how they can be applied to teleaudiology programs. There is a very large body of evidence supporting the benefits and utility of telehealth in terms of technology, econ...
Precordial ECG lead placement is difficult in obese patients with increased chest wall soft tissu... more Precordial ECG lead placement is difficult in obese patients with increased chest wall soft tissues due to inaccurate palpation of the intercostal spaces. We investigated whether the length of the sternum (distance between the sternal notch and xiphoid process) can accurately predict the location of the 4th intercostal space, which is the traditional location for V1 lead position. Fifty-five consecutive adult chest computed tomography examinations were reviewed for measurements. The sternal notch to right 4th intercostal space distance was 67% of the sternal notch to xiphoid process length with an overall correlation of r=0.600 (p&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt;0.001). The above measurement may be utilized to locate the 4th intercostal space for accurate placement of the precordial electrodes in adults in whom the 4th intercostal space cannot be found by physical exam.
Patients were surveyed to assess the impact of dopamine transporter imaging on diagnostic confide... more Patients were surveyed to assess the impact of dopamine transporter imaging on diagnostic confidence, change in treatment plan, effect on medication compliance, and subjective well-being. Surveys were sent to 140 patients who completed dopamine transporter imaging an average of 18 months prior. Sixty-five surveys from patients (46%) were returned. Questions assessed patients&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;#39; perceived impact of the imaging on their care. Increased diagnostic confidence following imaging was reported by 69% of patients. Changes to treatment plan from imaging were reported by 24% of patients. Overall satisfaction with the study and its impact was reported by 70% of patients. Dopamine transporter imaging increased diagnostic confidence among patients and overall patient satisfaction with the impact of imaging on clinical care was high.
The clinical reading environment for the 21st century pathologist looks very different than it di... more The clinical reading environment for the 21st century pathologist looks very different than it did even a few short years ago. Glass slides are quickly being replaced by digital "virtual slides," and the traditional light microscope is being replaced by the computer display. There are numerous questions that arise however when deciding exactly what this new digital display viewing environment will be like. Choosing a workstation for daily use in the interpretation of digital pathology images can be a very daunting task. Radiology went digital nearly 20 years ago and faced many of the same challenges so there are lessons to be learned from these experiences. One major lesson is that there is no "one size fits all" workstation so users must consider a variety of factors when choosing a workstation. In this article, we summarize some of the potentially critical elements in a pathology workstation and the characteristics one should be aware of and look for in the sel...
Rings, intravenous lines, and other objects on the injured upper extremities of trauma patients a... more Rings, intravenous lines, and other objects on the injured upper extremities of trauma patients are frequently overlooked by radiology and emergency department (ED) personnel. This can impair proper radiologic evaluation of the injured extremity as well as negatively affect the quality of the patient's treatment. A 1-week sample of radiographs of injured upper extremities from the ED of University Medical Center (UMC), Tucson, Arizona, showed that 20% of the studies (19 of 95) contained at least one object on the injured upper extremity, but only one radiology report (1.1%) mentioned such an object. A review of 2489 upper extremity ED radiology reports from January to June 2002 showed only 47 reports (1.9%) that mentioned the presence of an overlying object. It is important to educate radiology department and ED personnel to remove upper extremity jewelry and place necessary medical devices on noninjured extremities.
Prior studies have revealed little difference in residents' abilities to interpret cranial CT... more Prior studies have revealed little difference in residents' abilities to interpret cranial CT scans. The purpose of this study was to assess the performance of radiology residents at different levels of training in the interpretation of emergency head CT images. Radiology residents prospectively interpreted 1324 consecutive head CT scans ordered in the emergency department at the University of Arizona Health Science Center. The residents completed a preliminary interpretation form that included their interpretation and confidence in that interpretation. One of five neuroradiologists with a Certificate of Added Qualification subsequently interpreted the images and classified their assessment of the residents' interpretations as follows: "agree," "disagree-insignificant," or "disagree-significant." The data were analyzed by using analysis-of-variance or chi-squared methods. Overall, the agreement rate was 91%; the insignificant disagreement rate, ...
The ability to identify patients at increased risk for stroke from cerebral hemodynamic ischemia ... more The ability to identify patients at increased risk for stroke from cerebral hemodynamic ischemia may help guide treatment planning. We tested the correlation between regional cerebrovascular reserve (rCVR) on acetazolamide-challenged single-photon emission CT (SPECT) brain scans and intracranial collateral pathways as well as extra- or intracranial (EC-IC) arterial stenosis on cerebral angiography. A retrospective analysis of 27 patients who underwent cerebral angiography and acetazolamide-challenged SPECT brain imaging was performed. With cerebral angiography, the anterior, middle, and posterior cerebral artery (ACA, MCA, PCA) territories were evaluated for patterns of flow, including the ipsilateral carotid or basilar arteries, the circle of Willis collaterals, the EC-IC collaterals, and the leptomeningeal collaterals. With acetazolamide-challenged SPECT, the ACA, MCA, and PCA territories were classified as either showing or not showing evidence of decreased rCVR. Statistical sign...
To compare research grading of diabetic retinopathy (DR) severity level from compressed digital i... more To compare research grading of diabetic retinopathy (DR) severity level from compressed digital images versus uncompressed images and film. Compressed (JPEG2000, 37:1) digital images (C) were compared with uncompressed digital (U) and film (F) stereoscopic photographs from a 152-eye cohort with full-spectrum Early Treatment Diabetic Retinopathy Study severity levels for agreement on severity level, DR presence with ascending severity threshold, presence of DR index lesions, and repeatability of grading. Classification of Early Treatment Diabetic Retinopathy Study severity levels from C images agreed substantially with results from F images (κ = 0.60, κ(w) [linear weighted] = 0.86) and uncompressed digital images (κ = 0.76, κ(w) = 0.92). For agreement of uncompressed digital versus F images, κ = 0.62 and κ(w) = 0.86. Distribution of Early Treatment Diabetic Retinopathy Study levels was not significantly different between C and F images (P = 0.09, Bhapkar&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;#39;s test for marginal homogeneity). For presence/absence of DR at 8 ascending severity thresholds, agreement between C and F was &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;quot;almost perfect&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;quot; (κ ≥ 0.8). Agreement on severity level between readers with C images was at least as good as that with uncompressed digital image or F. Repeatability of severity threshold grading between readers was similar using C or F images. For identifying individual DR lesions, agreement between C and F ranged from &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;quot;moderate&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;quot; to &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;quot;perfect.&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;quot; Agreement of grading venous beading from C was slightly lower than from F. Full Early Treatment Diabetic Retinopathy Study scale DR severity level grading using C images is comparable to that using U images or film.
To evaluate digital photography parameters affecting comparability with the Early Treatment Diabe... more To evaluate digital photography parameters affecting comparability with the Early Treatment Diabetic Retinopathy Study (ETDRS) film protocol for diabetic retinopathy (DR) severity grading. ETDRS protocol photographs and four variations of digital images (uncompressed stereoscopic, compressed stereoscopic, uncompressed monoscopic, and uncompressed monoscopic wide-angle mosaic) of 152 eyes were independently evaluated by using ETDRS classifications. Digital formats were compared to film and each other for agreement on severity level, DR presence at ascending threshold, presence of the DR index lesion, and repeatability of grading. Study parameters included image resolution sufficient to distinguish small lesions, color balancing of digital images to film, documenting essential ETDRS classification retinal regions, similar magnification, and supplementary green-channel viewing. The κ statistic was substantial or near substantial between all digital formats and film for classifying severity levels (κ = 0.59-0.62; κ(w) [linear weighted] = 0.83-0.87). The distribution of DR levels in all digital formats was not significantly different from that of the film (Bhapkar test, P = 0.09-0.44). The κ among digital formats for severity level was also substantial or near substantial (κ = 0.58-0.76, κ(w) = 0.82-0.92). Differences between digital formats and film for grading severity level, severity threshold, or index lesions were not significant. The repeatability of grading between readers using film and all digital formats was also similar. Digital format variations compared favorably with film for DR classification. Translating film characteristics (resolution, color/contrast) and protocol (magnification, retinal regions) to digital equivalents and augmentation of full color with green-channel viewing most likely contributed to the results.
To assess agreement between digital and film photography for research classification of diabetic ... more To assess agreement between digital and film photography for research classification of diabetic retinopathy severity. Digital and film photographs from a 152-eye cohort with a full spectrum of Early Treatment Diabetic Retinopathy Study (ETDRS) severity levels were assessed for repeatability of grading within each image medium and for agreement on ETDRS discrete severity levels, ascending severity thresholds, and presence or absence of diabetic retinopathy index lesions, between digital and 35-mm slides (film). Digital photographs were color balanced to match film. There was substantial agreement (κ = 0.61, κ(w) [linear weighted] = 0.87) in classification of ETDRS diabetic retinopathy severity levels between digital images and film. Marginal homogeneity analyses found no significant difference in frequency distributions on the severity scale (P = 0.21, Bhapkar test). The κ results ranged from 0.72 to 0.95 for presence or absence of eight ascending diabetic retinopathy severity thresholds. Repeatability of grading between readers viewing digital images was equal to or better than that obtained with film (pair-wise interreader κ for digital images ranged from 0.47 to 0.57 and for film from 0.43 to 0.57. The κ results for identifying diabetic retinopathy lesions ranged from moderate to almost perfect. Moderate agreement of intraretinal microvascular abnormalities and venous beading between digital images and film accounted for slightly lower concordance for severity thresholds ≥47 and for slightly lower interreader agreement within digital and film images at severity thresholds ≥43 and ≥47. Under controlled circumstances, digital photography can equal the reliability of 35-mm slides for research classification of ETDRS severity level.
To assess agreement between monoscopic and stereoscopic photography for research classification o... more To assess agreement between monoscopic and stereoscopic photography for research classification of the severity of diabetic retinopathy (DR). Monoscopic digital (MD) images were compared with stereo digital (SD) and film (SF) photographs from a 152-eye cohort with full-spectrum Early Treatment Diabetic Retinopathy Study (ETDRS) severity levels for agreement on severity level, DR presence with ascending severity threshold, presence of DR index lesions, and repeatability of grading. There was substantial agreement classifying ETDRS DR severity levels between MD and SF (kappa = 0.65, kappa(w) [linear weighted] = 0.87), MD and SD (kappa = 0.66, kappa(w) = 0.87), and SD and SF (kappa = 0.62, kappa(w) = 0.86) images. Marginal homogeneity analyses found no significant difference between MD and SF images (P = 0.53, Bhapkar test). The kappa agreement between MD and SF ranged from 0.80 to 0.94 for the presence or absence of eight ascending DR severity thresholds. Repeatability between the readers of the MD images was equal to or better than that of the readers of SD or SF images. Severity threshold grading repeatability between readers was similar with the MD and SF images. The kappa agreement between MD and SF for identifying diabetic retinopathy lesions ranged from moderate to almost perfect. The kappa comparisons showed that performance of grading new vessels on the disc in MD images was slightly lower than that with the SF images. Monoscopic photography can equal the reliability of stereo photography for full ETDRS DR severity scale grading.
To assess agreement between evaluations of monoscopic and stereoscopic digital images versus ster... more To assess agreement between evaluations of monoscopic and stereoscopic digital images versus stereo film photographs in diabetic macular edema (DME). A 152-eye group of digital monoscopic macular images (seven-field sets and wide-angle mosaics) were compared with digital stereoscopic images (uncompressed and compressed seven-field sets) and stereo 35-mm film photos (Early Treatment Diabetic Retinopathy Study protocol) for the presence of hard exudates (HE), retinal thickening (RT), clinically significant macular edema (CSME), and RT at the center of the macular (RTCM). Agreement, according to the κ statistic, was almost perfect in identifying HE and RT between all digital formats and stereo film (HE, κ = 0.81-0.87; RT, κ = 0.87-0.92). Distribution in all digital formats was not significantly different from that in film (Bhapkar test: HE, P = 0.20-0.40; RT, P = 0.06-1.0). CSME and RTCM grading differences were either significant or trended toward significance. The readers detected CSME and RTCM in film images more often than in digital formats. In identifying DME features, agreement between evaluations of monoscopic digital formats and film was similar to that between stereo digital formats and film, and the performance of uncompressed images versus film was similar to that of compressed images versus film. Repeatability between readers was similar in evaluations of film and all digital formats. Repeatability in identifying RTCM was lower than that of other DME components in film and all digital formats. Stereoscopic digital formats are equivalent to monoscopic for DME evaluation, but digital photography is not as sensitive as film in detecting CSME and RTCM.
A number of studies have demonstrated that radiologists can become fatigued after reading cases f... more A number of studies have demonstrated that radiologists can become fatigued after reading cases for a number of hours. Some of these studies have demonstrated that there are associated decreases in observer performance (i.e., reduced accuracy), but mammographic reading has not been a focus of any of these studies. Based on these recent findings regarding decreases in performance as a
Two decades have passed since the publication of laboratory studies of satisfaction of search (SO... more Two decades have passed since the publication of laboratory studies of satisfaction of search (SOS) in chest radiography. Those studies were performed using film. The current investigation tests for SOS effects in computed radiography of the chest. Sixty-four chest computed radiographs half demonstrating various "test" abnormalities were read twice by 20 radiologists, once with and once without the addition of a simulated pulmonary nodule. Receiver-operating characteristic detection accuracy and decision thresholds were analyzed to study the effects of adding the nodule on detecting the test abnormalities. Results of previous studies were reanalyzed using similar modern techniques. In the present study, adding nodules did not influence detection accuracy for the other abnormalities (P = .93), but did induce a reluctance to report them (P < .001). Adding nodules did not affect inspection time (P = .58) so the reluctance to report was not associated with reduced search. R...
Telemedicine journal and e-health : the official journal of the American Telemedicine Association, Jan 28, 2015
Telemedicine is used with increasing frequency to improve patient care in remote areas. The inter... more Telemedicine is used with increasing frequency to improve patient care in remote areas. The interpretation of medical imaging on iPad(®) (Apple, Cupertino, CA) tablets has been reported to be accurate. There are no studies on the use of iPads for interpretation of pediatric echocardiograms. We compared the quality of echo images, diagnostic accuracy, and review time using three different modalities: remote access on an iPad Air (iPad), remote access via a computer (Remote), and direct access on a computer linked through Ethernet to the server, the "gold standard" (Direct). Fifty consecutive archived pediatric echocardiograms were interpreted using the three modalities. Studies were analyzed blindly by three pediatric cardiologists; review time, diagnostic accuracy, and image quality were documented. Diagnostic accuracy was assessed by comparing the study diagnoses with the official diagnosis in the patient's chart. Discrepancies between diagnoses were graded as major (...
Journal of the American Academy of Audiology, 2015
Health care is being fundamentally changed by telemedicine. Telemedicine uses communication techn... more Health care is being fundamentally changed by telemedicine. Telemedicine uses communication technologies in prevention, disease management, home health care, long-term (chronic) care, emergency medicine, and many other applications including audiology. Telemedicine is being adopted and integrated into the health care enterprise at an exponential rate and it is often difficult to keep up with all of these changes. Other key drivers such as the Affordable Care Act and other federal health care initiatives are pushing the adoption of telemedicine and catalyzing a flood of interest in telemedicine, telehealth, and m-Health. This paper provides an overview of telehealth models and will describe methodologies as they pertain to clinical practice. The goal is to provide the principles behind the practice of telemedicine and how they can be applied to teleaudiology programs. There is a very large body of evidence supporting the benefits and utility of telehealth in terms of technology, econ...
Precordial ECG lead placement is difficult in obese patients with increased chest wall soft tissu... more Precordial ECG lead placement is difficult in obese patients with increased chest wall soft tissues due to inaccurate palpation of the intercostal spaces. We investigated whether the length of the sternum (distance between the sternal notch and xiphoid process) can accurately predict the location of the 4th intercostal space, which is the traditional location for V1 lead position. Fifty-five consecutive adult chest computed tomography examinations were reviewed for measurements. The sternal notch to right 4th intercostal space distance was 67% of the sternal notch to xiphoid process length with an overall correlation of r=0.600 (p&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt;0.001). The above measurement may be utilized to locate the 4th intercostal space for accurate placement of the precordial electrodes in adults in whom the 4th intercostal space cannot be found by physical exam.
Patients were surveyed to assess the impact of dopamine transporter imaging on diagnostic confide... more Patients were surveyed to assess the impact of dopamine transporter imaging on diagnostic confidence, change in treatment plan, effect on medication compliance, and subjective well-being. Surveys were sent to 140 patients who completed dopamine transporter imaging an average of 18 months prior. Sixty-five surveys from patients (46%) were returned. Questions assessed patients&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;#39; perceived impact of the imaging on their care. Increased diagnostic confidence following imaging was reported by 69% of patients. Changes to treatment plan from imaging were reported by 24% of patients. Overall satisfaction with the study and its impact was reported by 70% of patients. Dopamine transporter imaging increased diagnostic confidence among patients and overall patient satisfaction with the impact of imaging on clinical care was high.
The clinical reading environment for the 21st century pathologist looks very different than it di... more The clinical reading environment for the 21st century pathologist looks very different than it did even a few short years ago. Glass slides are quickly being replaced by digital "virtual slides," and the traditional light microscope is being replaced by the computer display. There are numerous questions that arise however when deciding exactly what this new digital display viewing environment will be like. Choosing a workstation for daily use in the interpretation of digital pathology images can be a very daunting task. Radiology went digital nearly 20 years ago and faced many of the same challenges so there are lessons to be learned from these experiences. One major lesson is that there is no "one size fits all" workstation so users must consider a variety of factors when choosing a workstation. In this article, we summarize some of the potentially critical elements in a pathology workstation and the characteristics one should be aware of and look for in the sel...
Rings, intravenous lines, and other objects on the injured upper extremities of trauma patients a... more Rings, intravenous lines, and other objects on the injured upper extremities of trauma patients are frequently overlooked by radiology and emergency department (ED) personnel. This can impair proper radiologic evaluation of the injured extremity as well as negatively affect the quality of the patient's treatment. A 1-week sample of radiographs of injured upper extremities from the ED of University Medical Center (UMC), Tucson, Arizona, showed that 20% of the studies (19 of 95) contained at least one object on the injured upper extremity, but only one radiology report (1.1%) mentioned such an object. A review of 2489 upper extremity ED radiology reports from January to June 2002 showed only 47 reports (1.9%) that mentioned the presence of an overlying object. It is important to educate radiology department and ED personnel to remove upper extremity jewelry and place necessary medical devices on noninjured extremities.
Prior studies have revealed little difference in residents' abilities to interpret cranial CT... more Prior studies have revealed little difference in residents' abilities to interpret cranial CT scans. The purpose of this study was to assess the performance of radiology residents at different levels of training in the interpretation of emergency head CT images. Radiology residents prospectively interpreted 1324 consecutive head CT scans ordered in the emergency department at the University of Arizona Health Science Center. The residents completed a preliminary interpretation form that included their interpretation and confidence in that interpretation. One of five neuroradiologists with a Certificate of Added Qualification subsequently interpreted the images and classified their assessment of the residents' interpretations as follows: "agree," "disagree-insignificant," or "disagree-significant." The data were analyzed by using analysis-of-variance or chi-squared methods. Overall, the agreement rate was 91%; the insignificant disagreement rate, ...
The ability to identify patients at increased risk for stroke from cerebral hemodynamic ischemia ... more The ability to identify patients at increased risk for stroke from cerebral hemodynamic ischemia may help guide treatment planning. We tested the correlation between regional cerebrovascular reserve (rCVR) on acetazolamide-challenged single-photon emission CT (SPECT) brain scans and intracranial collateral pathways as well as extra- or intracranial (EC-IC) arterial stenosis on cerebral angiography. A retrospective analysis of 27 patients who underwent cerebral angiography and acetazolamide-challenged SPECT brain imaging was performed. With cerebral angiography, the anterior, middle, and posterior cerebral artery (ACA, MCA, PCA) territories were evaluated for patterns of flow, including the ipsilateral carotid or basilar arteries, the circle of Willis collaterals, the EC-IC collaterals, and the leptomeningeal collaterals. With acetazolamide-challenged SPECT, the ACA, MCA, and PCA territories were classified as either showing or not showing evidence of decreased rCVR. Statistical sign...
Uploads
Papers by Elizabeth Krupinski