Condensed Matter > Materials Science
[Submitted on 18 Mar 2019]
Title:Cooling rate effect on thermoremanent magnetization in archaeological baked clays: an experimental study on modern bricks
View PDFAbstract:The influence of cooling rate on the intensity of thermoremanent magnetization (TRM) and the necessity to correct archaeo/palaeointensities for this effect have long been recognized. However the reliability of the correction is still questioned. We studied 35 bricks baked in two modern kilns (SK and BK) in known experimental conditions and with measurements of the direction and intensity of the geomagnetic field at the site. The smallest kiln (SK, 0.2 m 3) cooled in around 12 hours and the biggest kiln (BK, 8 m 3) in around 40 hours. Thermomagnetic, hysteresis and backfield curves indicated that the main magnetic carriers were Ti-poor titanomagnetites and Tipoortitanohematites. The fraction of the TRM carried by Ti-poor titanohematites is the maindifference between the two sets of bricks. This fraction is around 5-10% in bricks from BK kilnand up to 40% in those from SK kiln. Intensities of the Earth's magnetic field were determinedusing the original Thellier-Thellier protocol with correction of TRM anisotropy. The averageintensities overestimate the expected field intensity by 5% (SK) and 6% (BK). This resultemphasizes the necessity of the cooling rate correction. In order to have a detailed evaluation ofthe cooling rate effect, we used several slow cooling rates: 0.8, 0.4, 0.2 and 0.1{\textdegree}C/min. Thecorrection factors obtained with the 0.8{\textdegree}C/min cooling ranged between -2% and 21% and wereproportional to the TRM fraction carried by Ti-poor titanohematite. The higher proportion ofthese grains in bricks from SK kiln led to an overestimate of the correction factor and anunderestimate of the intensity by 7%. However, the expected intensity is recovered whentemperature steps higher than 580{\textdegree}C (i.e. in the range of Ti-poor titanohematites unblockingtemperatures) were excluded from the calculation of archaeointensity and cooling rate this http URL the case of the BK kiln bricks, for which Ti-poor titanohematites does not contributesignificantly to the TRM, all tested cooling rates give average intensities close to the expectedvalue. Incorrectly estimating the duration of the archaeological cooling has therefore a lowimpact on the accuracy of the archaeointensity data on these kinds of material.
Submission history
From: Isabelle Dubigeon [view email] [via CCSD proxy][v1] Mon, 18 Mar 2019 13:32:01 UTC (1,557 KB)
Current browse context:
cond-mat.mtrl-sci
Change to browse by:
References & Citations
Bibliographic and Citation Tools
Bibliographic Explorer (What is the Explorer?)
Connected Papers (What is Connected Papers?)
Litmaps (What is Litmaps?)
scite Smart Citations (What are Smart Citations?)
Code, Data and Media Associated with this Article
alphaXiv (What is alphaXiv?)
CatalyzeX Code Finder for Papers (What is CatalyzeX?)
DagsHub (What is DagsHub?)
Gotit.pub (What is GotitPub?)
Hugging Face (What is Huggingface?)
Papers with Code (What is Papers with Code?)
ScienceCast (What is ScienceCast?)
Demos
Recommenders and Search Tools
Influence Flower (What are Influence Flowers?)
CORE Recommender (What is CORE?)
IArxiv Recommender
(What is IArxiv?)
arXivLabs: experimental projects with community collaborators
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.