Methodology of selective metallic thin film ablation from susceptible polymer substrate using pulsed femtosecond laser
Authors:
Chresten von der Heide,
Maria Grein,
Günther Bräuer,
Andreas Dietzel
Abstract:
Electronic devices are progressively fabricated on flexible substrates allowing new fields of applications. A maskless and very flexible structuring process is offered by ablation using ultra-short pulse laser irradiation. Usually, certain areas of a functional thin film coating are locally removed to yield the needed device structures. Micro laser patterning quality is not only influenced by the…
▽ More
Electronic devices are progressively fabricated on flexible substrates allowing new fields of applications. A maskless and very flexible structuring process is offered by ablation using ultra-short pulse laser irradiation. Usually, certain areas of a functional thin film coating are locally removed to yield the needed device structures. Micro laser patterning quality is not only influenced by the beam properties (beam profile, fluence) but also by pulse overlap, scan repetitions and many other factors such as substrate and coating material. This makes process parameter optimization a challenging task. In this paper, we present a systematic approach to efficiently find suitable parameters for laser-induced ablation of thin films on susceptible polymer substrates. As an example, we use a sputtered NiCr coating with a thickness of 100 $nm$ on a polyimide film made by spin coating of PI-2611 precursor (@ 2000 $rpm$ > ca. 8 $μm$, HD microsystems). Irradiation is conducted using a fs-laser with infrared wavelength of 1030 $nm$ and a pulse length of 212 $fs$. The energy per pulse is varied in the range of 0,29 $μJ$ to 4,83 $μJ$, yielding fluence values between 70 $mJ/cm^2$ and 1,11 $J/cm^2$. Ablation threshold fluence for a 100 $nm$ layer of NiCr was found to be $φ_{th}$ ($N_P$:1)=0,50 $J/cm^2$ and the incubation factor was evaluated to be $ξ$=0,53. A clear distinction must be made between the material ablation at the surface of a bulk material and the selective removal of a thin film. In the second case effects such as flaking occur in practice and influence the ablation characteristic. We then investigate different varieties of thin film removal including dot-, line- and areal-ablation. The methodology is presented using a practical example, but can be applied to selective ablation of a wide range of thin film systems.
△ Less
Submitted 10 February, 2020; v1 submitted 31 January, 2020;
originally announced February 2020.
Hydrogen mediated ferromagnetism in ZnO single crystals
Authors:
M. Khalid,
P. Esquinazi,
D. Spemann,
W. Anwand,
G. Brauer
Abstract:
We investigated the magnetic properties of hydrogen plasma treated ZnO single crystals by SQUID magnetometry. In agreement with the expected hydrogen penetration depth we found ferromagnetic behavior located at the first 20 nm of the H-treated surface of ZnO with magnetization at saturation up to 6 emu/g at 300 K and Curie temperature T$_c$ $\gtrsim $ 400 K. In the ferromagnetic samples a hydrogen…
▽ More
We investigated the magnetic properties of hydrogen plasma treated ZnO single crystals by SQUID magnetometry. In agreement with the expected hydrogen penetration depth we found ferromagnetic behavior located at the first 20 nm of the H-treated surface of ZnO with magnetization at saturation up to 6 emu/g at 300 K and Curie temperature T$_c$ $\gtrsim $ 400 K. In the ferromagnetic samples a hydrogen concentration of a few atomic percent in the first 20 nm surface layer was determined by nuclear reaction analysis. The saturation magnetization of H-treated ZnO increases with the concentration of hydrogen.
△ Less
Submitted 11 April, 2011;
originally announced April 2011.