Bunch Length and Energy Measurements in the Bunch-Compressor of a Free-Electron-Laser
Authors:
G. L. Orlandi,
R. Xue,
H. Brands,
F. Frei,
Z. Geng,
S. Bettoni
Abstract:
At SwissFEL, a fully non-invasive characterization of the beam energy distribution can be performed by means of a Synchrotron-Radiation-Monitor (SRM) imaging in the visible the transverse profile of the electron beam in a magnetic chicane. Under conditions of off-crest acceleration in the SwissFEL injector, according to a first order Taylor series expansion, the distribution of the relative energy…
▽ More
At SwissFEL, a fully non-invasive characterization of the beam energy distribution can be performed by means of a Synchrotron-Radiation-Monitor (SRM) imaging in the visible the transverse profile of the electron beam in a magnetic chicane. Under conditions of off-crest acceleration in the SwissFEL injector, according to a first order Taylor series expansion, the distribution of the relative energy of the electron beam can be linearly expressed as a function of the distribution of the electron longitudinal coordinates via the coefficient of the rf induced beam energy chirp. It is hence possible to express the distribution of the electron longitudinal coordinates at the entrance of the magnetic chicane of SwissFEL as a function of the distribution of the dispersed electron trajectories in the horizontal plane of the magnetic chicane. Machine parameters and instrument data at SwissFEL can be beam-synchronously acquired. A shot-by-shot correlation between the analysis results of the SRM camera images and the linear coefficient of the beam energy chirp resulting from the rf parameters of the injector can be hence established. Finally, taking into account the compression factor of the magnetic chicane, the electron bunch length at the exit of the magnetic chicane can be expressed as a function of the horizontal size of the electron beam imaged by the SRM. Bunch-length measurements performed by means of the SRM in the first magnetic chicane of SwissFEL will be presented.
△ Less
Submitted 20 May, 2019;
originally announced May 2019.
-
Lithium-loaded scintillators coupled to a custom-designed silicon photomultiplier array for neutron and gamma-ray detection
Authors:
Felix Liang,
Hartmut Brands,
Les Hoy,
Jeff Preston,
Jason Smith
Abstract:
Scintillators capable of detecting both neutrons and gamma-rays have generated considerable interest. In particular, the use of such scintillators with silicon photomultipliers (SiPMs) enables low-power and compact-geometry applications. Three types of Li-loaded scintillators, CLYC, CLLB, and NaIL, have been tested with a custom-designed SiPM array for temperatures between --20 and 50$^{\circ}$C.…
▽ More
Scintillators capable of detecting both neutrons and gamma-rays have generated considerable interest. In particular, the use of such scintillators with silicon photomultipliers (SiPMs) enables low-power and compact-geometry applications. Three types of Li-loaded scintillators, CLYC, CLLB, and NaIL, have been tested with a custom-designed SiPM array for temperatures between --20 and 50$^{\circ}$C. The array consists of four 6x6~mm$^2$ SiPMs arranged in a 2x2 configuration. Pulse shape discrimination is used for neutron and gamma identification. Because the pulse shape changes with temperature, the quality of neutron and gamma discrimination varies with temperature. Furthermore, the larger dark current in SiPMs at high temperatures results in poorer energy resolution and neutron-gamma discrimination. Comparison of the energy resolution and the neutron-gamma discrimination for the three scintillators coupled to the custom SiPM array will be discussed.
△ Less
Submitted 26 November, 2017;
originally announced November 2017.
-
Scintillation detectors constructed with an optimized 2x2 silicon photomultiplier array
Authors:
Felix Liang,
Hartmut Brands,
Les Hoy,
Jeff Preston,
Jason Smith
Abstract:
Silicon photomultipliers (SiPMs) are a good alternative to photomultiplier tubes (PMTs) because their gain and quantum efficiency are comparable to PMTs. However, the largest single-chip SiPM is still less than 1~cm$^2$. In order to use SiPMs with scintillators that have reasonable sensitivity, it is necessary to use multiple SiPMs. In this work, scintillation detectors are constructed and tested…
▽ More
Silicon photomultipliers (SiPMs) are a good alternative to photomultiplier tubes (PMTs) because their gain and quantum efficiency are comparable to PMTs. However, the largest single-chip SiPM is still less than 1~cm$^2$. In order to use SiPMs with scintillators that have reasonable sensitivity, it is necessary to use multiple SiPMs. In this work, scintillation detectors are constructed and tested with a custom 2x2 SiPM array. The layout of the SiPMs and the geometry of the scintillator were determined by performing Geant4 simulations. Cubic NaI, CsI, and CLYC with 18~mm sides have been tested. The output of the scintillation detectors are stabilized over the temperature range between --20 and 50~$^{\circ}$C by matching the gain of the SiPMs in the array. The energy resolution for these detectors has been measured as a function of temperature. Furthermore, neutron detection for the CLYC detector was studied in the same temperature range. Using pulse-shape discrimination, neutrons can be cleanly identified without contribution from $γ$-photons. As a result, these detectors are suitable for deploying in spectroscopic personal radiation detectors (SPRD).
△ Less
Submitted 22 December, 2016;
originally announced December 2016.
-
Design and Test of Wire-Scanners for SwissFEL
Authors:
G. L. Orlandi,
M. Baldinger,
H. Brands,
P. Heimgartner,
R. Ischebeck,
A. Kammerer,
F. Löhl,
R. Lüscher,
P. Mohanmurthy,
C. Ozkan,
V. Schlott,
L. Schulz,
B. Rippstein,
C. Seiler,
S. Trovati,
P. Valitutti,
D. Zimoch
Abstract:
The SwissFEL light-facility will provide coherent X-rays in the wavelength region 7-0.7 nm and 0.7-0.1 nm. In SwissFEL, view-screens and wire-scanners will be used to monitor the transverse profile of a 200/10pC electron beam with a normalized emittance of 0.4/0.2 mm.mrad and a final energy of 5.8 GeV. Compared to view screens, wire-scanners offer a quasi-non-destructive monitoring of the beam tra…
▽ More
The SwissFEL light-facility will provide coherent X-rays in the wavelength region 7-0.7 nm and 0.7-0.1 nm. In SwissFEL, view-screens and wire-scanners will be used to monitor the transverse profile of a 200/10pC electron beam with a normalized emittance of 0.4/0.2 mm.mrad and a final energy of 5.8 GeV. Compared to view screens, wire-scanners offer a quasi-non-destructive monitoring of the beam transverse profile without suffering from possible micro-bunching of the electron beam. The main aspects of the design, laboratory characterization and beam-test of the SwissFEL wire-scanner prototype will be discussed.
△ Less
Submitted 1 November, 2016;
originally announced November 2016.
-
Commissioning experience and beam physics measurements at the SwissFEL Injector Test Facility
Authors:
T. Schietinger,
M. Pedrozzi,
M. Aiba,
V. Arsov,
S. Bettoni,
B. Beutner,
M. Calvi,
P. Craievich,
M. Dehler,
F. Frei,
R. Ganter,
C. P. Hauri,
R. Ischebeck,
Y. Ivanisenko,
M. Janousch,
M. Kaiser,
B. Keil,
F. Löhl,
G. L. Orlandi,
C. Ozkan Loch,
P. Peier,
E. Prat,
J. -Y. Raguin,
S. Reiche,
T. Schilcher
, et al. (70 additional authors not shown)
Abstract:
The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and testbed for the development and realization of SwissFEL, the X-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chican…
▽ More
The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and testbed for the development and realization of SwissFEL, the X-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chicane and a diagnostic section including a transverse deflecting rf cavity. It delivered electron bunches of up to 200 pC charge and up to 250 MeV beam energy at a repetition rate of 10 Hz. The measurements performed at the test facility not only demonstrated the beam parameters required to drive the first stage of an FEL facility, but also led to significant advances in instrumentation technologies, beam characterization methods and the generation, transport and compression of ultra-low-emittance beams. We give a comprehensive overview of the commissioning experience of the principal subsystems and the beam physics measurements performed during the operation of the test facility, including the results of the test of an in-vacuum undulator prototype generating radiation in the vacuum ultraviolet and optical range.
△ Less
Submitted 27 October, 2016; v1 submitted 8 June, 2016;
originally announced June 2016.