A portable widefield fundus camera with high dynamic range imaging capability
Authors:
Alfa Rossi,
Mojtaba Rahimi,
David Le,
Taeyoon son,
Michael J. Heiferman,
R. V. Paul Chan,
Xincheng Yao
Abstract:
Fundus photography is indispensable for clinical detection and management of eye diseases. Limited image contrast and field of view (FOV) are common limitations of conventional fundus cameras, making it difficult to detect subtle abnormalities at the early stages of eye diseases. Further improvements of image contrast and FOV coverage are important to improve early disease detection and reliable t…
▽ More
Fundus photography is indispensable for clinical detection and management of eye diseases. Limited image contrast and field of view (FOV) are common limitations of conventional fundus cameras, making it difficult to detect subtle abnormalities at the early stages of eye diseases. Further improvements of image contrast and FOV coverage are important to improve early disease detection and reliable treatment assessment. We report here a portable fundus camera, with a wide FOV and high dynamic range (HDR) imaging capabilities. Miniaturized indirect ophthalmoscopy illumination was employed to achieve the portable design for nonmydriatic, widefield fundus photography. Orthogonal polarization control was used to eliminate illumination reflectance artifact. With independent power controls, three fundus images were sequentially acquired and fused to achieve HDR function for local image contrast enhancement. A 101° eye-angle (67° visual-angle) snapshot FOV was achieved for nonmydriatic fundus photography. The effective FOV can be readily expanded up to 190° eye-angle (134° visual-angle) with the aid of a fixation target, without the need of pharmacologic pupillary dilation. The effectiveness of HDR imaging was validated with both normal healthy and pathologic eyes, compared to a conventional fundus camera.
△ Less
Submitted 20 December, 2022;
originally announced December 2022.
-
Contrastive learning-based pretraining improves representation and transferability of diabetic retinopathy classification models
Authors:
Minhaj Nur Alam,
Rikiya Yamashita,
Vignav Ramesh,
Tejas Prabhune,
Jennifer I. Lim,
R. V. P. Chan,
Joelle Hallak,
Theodore Leng,
Daniel Rubin
Abstract:
Self supervised contrastive learning based pretraining allows development of robust and generalized deep learning models with small, labeled datasets, reducing the burden of label generation. This paper aims to evaluate the effect of CL based pretraining on the performance of referrable vs non referrable diabetic retinopathy (DR) classification. We have developed a CL based framework with neural s…
▽ More
Self supervised contrastive learning based pretraining allows development of robust and generalized deep learning models with small, labeled datasets, reducing the burden of label generation. This paper aims to evaluate the effect of CL based pretraining on the performance of referrable vs non referrable diabetic retinopathy (DR) classification. We have developed a CL based framework with neural style transfer (NST) augmentation to produce models with better representations and initializations for the detection of DR in color fundus images. We compare our CL pretrained model performance with two state of the art baseline models pretrained with Imagenet weights. We further investigate the model performance with reduced labeled training data (down to 10 percent) to test the robustness of the model when trained with small, labeled datasets. The model is trained and validated on the EyePACS dataset and tested independently on clinical data from the University of Illinois, Chicago (UIC). Compared to baseline models, our CL pretrained FundusNet model had higher AUC (CI) values (0.91 (0.898 to 0.930) vs 0.80 (0.783 to 0.820) and 0.83 (0.801 to 0.853) on UIC data). At 10 percent labeled training data, the FundusNet AUC was 0.81 (0.78 to 0.84) vs 0.58 (0.56 to 0.64) and 0.63 (0.60 to 0.66) in baseline models, when tested on the UIC dataset. CL based pretraining with NST significantly improves DL classification performance, helps the model generalize well (transferable from EyePACS to UIC data), and allows training with small, annotated datasets, therefore reducing ground truth annotation burden of the clinicians.
△ Less
Submitted 24 August, 2022;
originally announced August 2022.
-
Not Color Blind: AI Predicts Racial Identity from Black and White Retinal Vessel Segmentations
Authors:
Aaron S. Coyner,
Praveer Singh,
James M. Brown,
Susan Ostmo,
R. V. Paul Chan,
Michael F. Chiang,
Jayashree Kalpathy-Cramer,
J. Peter Campbell
Abstract:
Background: Artificial intelligence (AI) may demonstrate racial bias when skin or choroidal pigmentation is present in medical images. Recent studies have shown that convolutional neural networks (CNNs) can predict race from images that were not previously thought to contain race-specific features. We evaluate whether grayscale retinal vessel maps (RVMs) of patients screened for retinopathy of pre…
▽ More
Background: Artificial intelligence (AI) may demonstrate racial bias when skin or choroidal pigmentation is present in medical images. Recent studies have shown that convolutional neural networks (CNNs) can predict race from images that were not previously thought to contain race-specific features. We evaluate whether grayscale retinal vessel maps (RVMs) of patients screened for retinopathy of prematurity (ROP) contain race-specific features.
Methods: 4095 retinal fundus images (RFIs) were collected from 245 Black and White infants. A U-Net generated RVMs from RFIs, which were subsequently thresholded, binarized, or skeletonized. To determine whether RVM differences between Black and White eyes were physiological, CNNs were trained to predict race from color RFIs, raw RVMs, and thresholded, binarized, or skeletonized RVMs. Area under the precision-recall curve (AUC-PR) was evaluated.
Findings: CNNs predicted race from RFIs near perfectly (image-level AUC-PR: 0.999, subject-level AUC-PR: 1.000). Raw RVMs were almost as informative as color RFIs (image-level AUC-PR: 0.938, subject-level AUC-PR: 0.995). Ultimately, CNNs were able to detect whether RFIs or RVMs were from Black or White babies, regardless of whether images contained color, vessel segmentation brightness differences were nullified, or vessel segmentation widths were normalized.
Interpretation: AI can detect race from grayscale RVMs that were not thought to contain racial information. Two potential explanations for these findings are that: retinal vessels physiologically differ between Black and White babies or the U-Net segments the retinal vasculature differently for various fundus pigmentations. Either way, the implications remain the same: AI algorithms have potential to demonstrate racial bias in practice, even when preliminary attempts to remove such information from the underlying images appear to be successful.
△ Less
Submitted 28 September, 2021;
originally announced September 2021.
-
Trans-pars-planar illumination enables 200° ultra-wide field pediatric fundus photography for easy examination of the retina
Authors:
Devrim Toslak,
Felix Chau,
Muhammet Kazim Erol,
Changgeng Liu,
R. V. Paul Chan,
Taeyoon Son,
Xincheng Yao
Abstract:
This study is to test the feasibility of using trans-pars-planar illumination for ultrawide field pediatric fundus photography. Fundus examination of the peripheral retina is essential for clinical management of pediatric eye diseases. However, current pediatric fundus cameras with traditional trans-pupillary illumination provide a limited field of view (FOV), making it difficult to access the per…
▽ More
This study is to test the feasibility of using trans-pars-planar illumination for ultrawide field pediatric fundus photography. Fundus examination of the peripheral retina is essential for clinical management of pediatric eye diseases. However, current pediatric fundus cameras with traditional trans-pupillary illumination provide a limited field of view (FOV), making it difficult to access the peripheral retina adequately for a comprehensive assessment of eye conditions. Here, we report the first demonstration of trans-pars-planar illumination in ultra-wide field pediatric fundus photography. For proof-of-concept validation, all off-the-shelf optical components were selected to construct a lab prototype pediatric camera (PedCam). By freeing the entire pupil for imaging purpose only, the trans-pars-planar illumination enables a 200o FOV in a snapshot fundus image, allowing easy visualization of both the central and peripheral retina up to the ora serrata. A low-cost, easy-to-use ultra-wide field PedCam provides a unique opportunity to foster affordable telemedicine in rural and underserved areas.
△ Less
Submitted 15 October, 2019;
originally announced October 2019.
-
Transfer Learning for Automated OCTA Detection of Diabetic Retinopathy
Authors:
David Le,
Minhaj Alam,
Cham Yao,
Jennifer I. Lim,
R. V. P. Chan,
Devrim Toslak,
Xincheng Yao
Abstract:
Purpose: To test the feasibility of using deep learning for optical coherence tomography angiography (OCTA) detection of diabetic retinopathy (DR). Methods: A deep learning convolutional neural network (CNN) architecture VGG16 was employed for this study. A transfer learning process was implemented to re-train the CNN for robust OCTA classification. In order to demonstrate the feasibility of using…
▽ More
Purpose: To test the feasibility of using deep learning for optical coherence tomography angiography (OCTA) detection of diabetic retinopathy (DR). Methods: A deep learning convolutional neural network (CNN) architecture VGG16 was employed for this study. A transfer learning process was implemented to re-train the CNN for robust OCTA classification. In order to demonstrate the feasibility of using this method for artificial intelligence (AI) screening of DR in clinical environments, the re-trained CNN was incorporated into a custom developed GUI platform which can be readily operated by ophthalmic personnel. Results: With last nine layers re-trained, CNN architecture achieved the best performance for automated OCTA classification. The overall accuracy of the re-trained classifier for differentiating healthy, NoDR, and NPDR was 87.27%, with 83.76% sensitivity and 90.82% specificity. The AUC metrics for binary classification of healthy, NoDR and DR were 0.97, 0.98 and 0.97, respectively. The GUI platform enabled easy validation of the method for AI screening of DR in a clinical environment. Conclusion: With a transfer leaning process to adopt the early layers for simple feature analysis and to re-train the upper layers for fine feature analysis, the CNN architecture VGG16 can be used for robust OCTA classification of healthy, NoDR, and NPDR eyes. Translational Relevance: OCTA can capture microvascular changes in early DR. A transfer learning process enables robust implementation of convolutional neural network (CNN) for automated OCTA classification of DR.
△ Less
Submitted 4 October, 2019;
originally announced October 2019.
-
Supervised machine learning based multi-task artificial intelligence classification of retinopathies
Authors:
Minhaj Alam,
David Le,
Jennifer I. Lim,
R. V. P. Chan,
Xincheng Yao
Abstract:
Artificial intelligence (AI) classification holds promise as a novel and affordable screening tool for clinical management of ocular diseases. Rural and underserved areas, which suffer from lack of access to experienced ophthalmologists may particularly benefit from this technology. Quantitative optical coherence tomography angiography (OCTA) imaging provides excellent capability to identify subtl…
▽ More
Artificial intelligence (AI) classification holds promise as a novel and affordable screening tool for clinical management of ocular diseases. Rural and underserved areas, which suffer from lack of access to experienced ophthalmologists may particularly benefit from this technology. Quantitative optical coherence tomography angiography (OCTA) imaging provides excellent capability to identify subtle vascular distortions, which are useful for classifying retinovascular diseases. However, application of AI for differentiation and classification of multiple eye diseases is not yet established. In this study, we demonstrate supervised machine learning based multi-task OCTA classification. We sought 1) to differentiate normal from diseased ocular conditions, 2) to differentiate different ocular disease conditions from each other, and 3) to stage the severity of each ocular condition. Quantitative OCTA features, including blood vessel tortuosity (BVT), blood vascular caliber (BVC), vessel perimeter index (VPI), blood vessel density (BVD), foveal avascular zone (FAZ) area (FAZ-A), and FAZ contour irregularity (FAZ-CI) were fully automatically extracted from the OCTA images. A stepwise backward elimination approach was employed to identify sensitive OCTA features and optimal-feature-combinations for the multi-task classification. For proof-of-concept demonstration, diabetic retinopathy (DR) and sickle cell retinopathy (SCR) were used to validate the supervised machine leaning classifier. The presented AI classification methodology is applicable and can be readily extended to other ocular diseases, holding promise to enable a mass-screening platform for clinical deployment and telemedicine.
△ Less
Submitted 10 May, 2019;