The DAMIC-M Low Background Chamber
Authors:
I. Arnquist,
N. Avalos,
P. Bailly,
D. Baxter,
X. Bertou,
M. Bogdan,
C. Bourgeois,
J. Brandt,
A. Cadiou,
N. Castello-Mor,
A. E. Chavarria,
M. Conde,
J. Cuevas-Zepeda,
A. Dastgheibi-Fard,
C. De Dominicis,
O. Deligny,
R. Desani,
M. Dhellot,
J. Duarte-Campderros,
E. Estrada,
D. Florin,
N. Gadola,
R. Gaior,
E. -L. Gkougkousis,
J. Gonzalez Sanchez
, et al. (45 additional authors not shown)
Abstract:
The DArk Matter In CCDs at Modane (DAMIC-M) experiment is designed to search for light dark matter (m$_χ$<10\,GeV/c$^2$) at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-M will use skipper charge-coupled devices (CCDs) as a kg-scale active detector target. Its single-electron resolution will enable eV-scale energy thresholds and thus world-leading sensitivity to a range of hidden sec…
▽ More
The DArk Matter In CCDs at Modane (DAMIC-M) experiment is designed to search for light dark matter (m$_χ$<10\,GeV/c$^2$) at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-M will use skipper charge-coupled devices (CCDs) as a kg-scale active detector target. Its single-electron resolution will enable eV-scale energy thresholds and thus world-leading sensitivity to a range of hidden sector dark matter candidates. A DAMIC-M prototype, the Low Background Chamber (LBC), has been taking data at LSM since 2022. The LBC provides a low-background environment, which has been used to characterize skipper CCDs, study dark current, and measure radiopurity of materials planned for DAMIC-M. It also allows testing of various subsystems like readout electronics, data acquisition software, and slow control. This paper describes the technical design and performance of the LBC.
△ Less
Submitted 25 July, 2024;
originally announced July 2024.
-
Nuclear Recoil Identification in a Scientific Charge-Coupled Device
Authors:
K. J. McGuire,
A. E. Chavarria,
N. Castello-Mor,
S. Lee,
B. Kilminster,
R. Vilar,
A. Alvarez,
J. Jung,
J. Cuevas-Zepeda,
C. De Dominicis,
R. Gaïor,
L. Iddir,
A. Letessier-Selvon,
H. Lin,
S. Munagavalasa,
D. Norcini,
S. Paul,
P. Privitera,
R. Smida,
M. Traina,
R. Yajur,
J-P. Zopounidis
Abstract:
Charge-coupled devices (CCDs) are a leading technology in direct dark matter searches because of their eV-scale energy threshold and high spatial resolution. The sensitivity of future CCD experiments could be enhanced by distinguishing nuclear recoil signals from electronic recoil backgrounds in the CCD silicon target. We present a technique for event-by-event identification of nuclear recoils bas…
▽ More
Charge-coupled devices (CCDs) are a leading technology in direct dark matter searches because of their eV-scale energy threshold and high spatial resolution. The sensitivity of future CCD experiments could be enhanced by distinguishing nuclear recoil signals from electronic recoil backgrounds in the CCD silicon target. We present a technique for event-by-event identification of nuclear recoils based on the spatial correlation between the primary ionization event and the lattice defect left behind by the recoiling atom, later identified as a localized excess of leakage current under thermal stimulation. By irradiating a CCD with an $^{241}$Am$^{9}$Be neutron source, we demonstrate $>93\%$ identification efficiency for nuclear recoils with energies $>150$ keV, where the ionization events were confirmed to be nuclear recoils from topology. The technique remains fully efficient down to 90 keV, decreasing to 50$\%$ at 8 keV, and reaching ($6\pm2$)$\%$ at 1.5--3.5 keV. Irradiation with a $^{24}$Na $γ$-ray source shows no evidence of defect generation by electronic recoils, with the fraction of electronic recoils with energies $<85$ keV that are spatially correlated with defects $<0.1$$\%$.
△ Less
Submitted 11 August, 2024; v1 submitted 14 September, 2023;
originally announced September 2023.
-
The DAMIC excess from WIMP-nucleus elastic scattering
Authors:
A. E. Chavarria,
H. Lin,
K. J. McGuire,
A. Piers,
M. Traina
Abstract:
Two dark matter searches performed with charge-coupled devices (CCDs) in the DAMIC cryostat at SNOLAB reported with high statistical significance the presence of an unidentified source of low-energy events in bulk silicon. The observed spectrum is consistent with nuclear recoils from the elastic scattering of weakly interacting massive particles (WIMPs) with masses between 2 and 4 GeV. In the stan…
▽ More
Two dark matter searches performed with charge-coupled devices (CCDs) in the DAMIC cryostat at SNOLAB reported with high statistical significance the presence of an unidentified source of low-energy events in bulk silicon. The observed spectrum is consistent with nuclear recoils from the elastic scattering of weakly interacting massive particles (WIMPs) with masses between 2 and 4 GeV. In the standard scenario of spin-independent WIMP-nucleus scattering, the derived cross section is conclusively excluded by results in argon by the DarkSide-50 experiment. We identify isospin-violating and spin-dependent scenarios where interactions with $^{40}$Ar are strongly suppressed and the interpretation of the DAMIC excess as WIMP-nucleus elastic scattering remains viable.
△ Less
Submitted 26 March, 2024; v1 submitted 23 August, 2023;
originally announced August 2023.
-
Search for Daily Modulation of MeV Dark Matter Signals with DAMIC-M
Authors:
I. Arnquist,
N. Avalos,
D. Baxter,
X. Bertou,
N. Castello-Mor,
A. E. Chavarria,
J. Cuevas-Zepeda,
A. Dastgheibi-Fard,
C. De Dominicis,
O. Deligny,
J. Duarte-Campderros,
E. Estrada,
N. Gadola,
R. Gaior,
T. Hossbach,
L. Iddir,
B. J. Kavanagh,
B. Kilminster,
A. Lantero-Barreda,
I. Lawson,
S. Lee,
A. Letessier-Selvon,
P. Loaiza,
A. Lopez-Virto,
K. J. McGuire
, et al. (15 additional authors not shown)
Abstract:
Dark Matter (DM) particles with sufficiently large cross sections may scatter as they travel through Earth's bulk. The corresponding changes in the DM flux give rise to a characteristic daily modulation signal in detectors sensitive to DM-electron interactions. Here, we report results obtained from the first underground operation of the DAMIC-M prototype detector searching for such a signal from D…
▽ More
Dark Matter (DM) particles with sufficiently large cross sections may scatter as they travel through Earth's bulk. The corresponding changes in the DM flux give rise to a characteristic daily modulation signal in detectors sensitive to DM-electron interactions. Here, we report results obtained from the first underground operation of the DAMIC-M prototype detector searching for such a signal from DM with MeV-scale mass. A model-independent analysis finds no modulation in the rate of 1$e^-$ events with periods in the range 1-48 h. We then use these data to place exclusion limits on DM in the mass range [0.53, 2.7] MeV/c$^2$ interacting with electrons via a dark photon mediator. Taking advantage of the time-dependent signal we improve by $\sim$2 orders of magnitude on our previous limit obtained from the total rate of 1$e^-$ events, using the same data set. This daily modulation search represents the current strongest limit on DM-electron scattering via ultralight mediators for DM masses around 1 MeV/c$^2$.
△ Less
Submitted 14 July, 2023;
originally announced July 2023.
-
Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs
Authors:
A. Aguilar-Arevalo,
I. Arnquist,
N. Avalos,
L. Barak,
D. Baxter,
X. Bertou,
I. M. Bloch,
A. M. Botti,
M. Cababie,
G. Cancelo,
N. Castelló-Mor,
B. A. Cervantes-Vergara,
A. E. Chavarria,
J. Cortabitarte-Gutiérrez,
M. Crisler,
J. Cuevas-Zepeda,
A. Dastgheibi-Fard,
C. De Dominicis,
O. Deligny,
A. Drlica-Wagner,
J. Duarte-Campderros,
J. C. D'Olivo,
R. Essig,
E. Estrada,
J. Estrada
, et al. (47 additional authors not shown)
Abstract:
We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. W…
▽ More
We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ${\sim}7$ events per kg-day and electron-equivalent energies of ${\sim}80~$eV, whose origin remains unknown.
△ Less
Submitted 26 March, 2024; v1 submitted 2 June, 2023;
originally announced June 2023.
-
Searching for millicharged particles with 1 kg of Skipper-CCDs using the NuMI beam at Fermilab
Authors:
Santiago Perez,
Dario Rodrigues,
Juan Estrada,
Roni Harnik,
Zhen Liu,
Brenda A. Cervantes-Vergara,
Juan Carlos D'Olivo,
Ryan D. Plestid,
Javier Tiffenberg,
Tien-Tien Yu,
Alexis Aguilar-Arevalo,
Fabricio Alcalde-Bessia,
Nicolas Avalos,
Oscar Baez,
Daniel Baxter,
Xavier Bertou,
Carla Bonifazi,
Ana Botti,
Gustavo Cancelo,
Nuria Castelló-Mor,
Alvaro E. Chavarria,
Claudio R. Chavez,
Fernando Chierchie,
Juan Manuel De Egea,
Cyrus Dreyer
, et al. (35 additional authors not shown)
Abstract:
Oscura is a planned light-dark matter search experiment using Skipper-CCDs with a total active mass of 10 kg. As part of the detector development, the collaboration plans to build the Oscura Integration Test (OIT), an engineering test with 10% of the total mass. Here we discuss the early science opportunities with the OIT to search for millicharged particles (mCPs) using the NuMI beam at Fermilab.…
▽ More
Oscura is a planned light-dark matter search experiment using Skipper-CCDs with a total active mass of 10 kg. As part of the detector development, the collaboration plans to build the Oscura Integration Test (OIT), an engineering test with 10% of the total mass. Here we discuss the early science opportunities with the OIT to search for millicharged particles (mCPs) using the NuMI beam at Fermilab. mCPs would be produced at low energies through photon-mediated processes from decays of scalar, pseudoscalar, and vector mesons, or direct Drell-Yan productions. Estimates show that the OIT would be a world-leading probe for mCPs in the MeV mass range.
△ Less
Submitted 2 December, 2023; v1 submitted 17 April, 2023;
originally announced April 2023.
-
Skipper-CCD Sensors for the Oscura Experiment: Requirements and Preliminary Tests
Authors:
Brenda A. Cervantes-Vergara,
Santiago Perez,
Juan Estrada,
Ana Botti,
Claudio R. Chavez,
Fernando Chierchie,
Nathan Saffold,
Alexis Aguilar-Arevalo,
Fabricio Alcalde-Bessia,
Nicolás Avalos,
Oscar Baez,
Daniel Baxter,
Xavier Bertou,
Carla Bonifazi,
Gustavo Cancelo,
Nuria Castelló-Mor,
Alvaro E. Chavarria,
Juan Manuel De Egea,
Juan Carlos D'Olivo,
Cyrus Dreyer,
Alex Drlica-Wagner,
Rouven Essig,
Ezequiel Estrada,
Erez Etzion,
Paul Grylls
, et al. (30 additional authors not shown)
Abstract:
Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2-10 electron ionization-signal…
▽ More
Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2-10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru. In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.
△ Less
Submitted 11 April, 2024; v1 submitted 10 April, 2023;
originally announced April 2023.
-
First Constraints from DAMIC-M on Sub-GeV Dark-Matter Particles Interacting with Electrons
Authors:
I. Arnquist,
N. Avalos,
D. Baxter,
X. Bertou,
N. Castello-Mor,
A. E. Chavarria,
J. Cuevas-Zepeda,
J. Cortabitarte Gutierrez,
J. Duarte-Campderros,
A. Dastgheibi-Fard,
O. Deligny,
C. De Dominicis,
E. Estrada,
N. Gadola,
R. Gaıor,
T. Hossbach,
L. Iddir,
L. Khalil,
B. Kilminster,
A. Lantero-Barreda,
I. Lawson,
S. Lee,
A. Letessier-Selvon,
P. Loaiza,
A. Lopez-Virto
, et al. (20 additional authors not shown)
Abstract:
We report constraints on sub-GeV dark matter particles interacting with electrons from the first underground operation of DAMIC-M detectors. The search is performed with an integrated exposure of 85.23 g days, and exploits the sub-electron charge resolution and low level of dark current of DAMIC-M Charge-Coupled Devices (CCDs). Dark-matter-induced ionization signals above the detector dark current…
▽ More
We report constraints on sub-GeV dark matter particles interacting with electrons from the first underground operation of DAMIC-M detectors. The search is performed with an integrated exposure of 85.23 g days, and exploits the sub-electron charge resolution and low level of dark current of DAMIC-M Charge-Coupled Devices (CCDs). Dark-matter-induced ionization signals above the detector dark current are searched for in CCD pixels with charge up to 7 e-. With this data set we place limits on dark matter particles of mass between 0.53 and 1000 MeV/c2, excluding unexplored regions of parameter space in the mass ranges [1.6,1000] MeV/c2 and [1.5,15.1] MeV/c2 for ultra-light and heavy mediator interactions, respectively.
△ Less
Submitted 5 February, 2023;
originally announced February 2023.
-
Background Rejection in Highly Pixelated Solid-State Detectors
Authors:
Alvaro E. Chavarria
Abstract:
Highly pixelated solid-state detectors offer outstanding capabilities in the identification and suppression of backgrounds from natural radioactivity. We present the background-identification strategies developed for the DAMIC experiment, which employs silicon charge-coupled devices to search for dark matter. DAMIC has demonstrated the capability to disentangle and measure the activities of every…
▽ More
Highly pixelated solid-state detectors offer outstanding capabilities in the identification and suppression of backgrounds from natural radioactivity. We present the background-identification strategies developed for the DAMIC experiment, which employs silicon charge-coupled devices to search for dark matter. DAMIC has demonstrated the capability to disentangle and measure the activities of every $β$ emitter from the $^{32}$Si, $^{238}$U and $^{232}$Th decay chains in the silicon target. Similar strategies will be adopted by the Selena Neutrino Experiment, which will employ hybrid amorphous $^{82}$Se/CMOS imagers to perform spectroscopy of $ββ$ decay and solar neutrinos. We present the proposed experimental strategy for Selena to achieve zero-background in a 100-ton-year exposure.
△ Less
Submitted 9 December, 2022;
originally announced December 2022.
-
The DAMIC-M Experiment: Status and First Results
Authors:
I. Arnquist,
N. Avalos,
P. Bailly,
D. Baxter,
X. Bertou,
M. Bogdan,
C. Bourgeois,
J. Brandt,
A. Cadiou,
N. Castelló-Mor,
A. E. Chavarria,
M. Conde,
N. J. Corso,
J. Cortabitarte Gutiérrez,
J. Cuevas-Zepeda,
A. Dastgheibi-Fard,
C. De Dominicis,
O. Deligny,
R. Desani,
M. Dhellot,
J-J. Dormard,
J. Duarte-Campderros,
E. Estrada,
D. Florin,
N. Gadola
, et al. (47 additional authors not shown)
Abstract:
The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV…
▽ More
The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called "hidden sector." A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.
△ Less
Submitted 25 November, 2022; v1 submitted 11 October, 2022;
originally announced October 2022.
-
Even Lighter Particle Dark Matter
Authors:
Alvaro E. Chavarria
Abstract:
We report on recent progress in the search for dark matter particles with masses from 1 MeV to 1 GeV. Several dark matter candidates in this mass range are expected to generate measurable electronic-recoil signals in direct-detection experiments. We focus on dark matter particles scattering with electrons in semiconductor detectors since they have fundamentally the highest sensitivity due to their…
▽ More
We report on recent progress in the search for dark matter particles with masses from 1 MeV to 1 GeV. Several dark matter candidates in this mass range are expected to generate measurable electronic-recoil signals in direct-detection experiments. We focus on dark matter particles scattering with electrons in semiconductor detectors since they have fundamentally the highest sensitivity due to their low ionization threshold. Charge-coupled device (CCD) silicon detectors are the leading technology, with significant progress expected in the coming years. We present the status of the CCD program and briefly report on other efforts.
△ Less
Submitted 29 December, 2022; v1 submitted 11 October, 2022;
originally announced October 2022.
-
The low-energy spectrum in DAMIC at SNOLAB
Authors:
Alvaro E. Chavarria
Abstract:
The DAMIC experiment employs large-area, thick charge-coupled devices (CCDs) to search for the interactions of low-mass dark matter particles in the galactic halo with silicon atoms in the CCD target. From 2017 to 2019, DAMIC collected data with a seven-CCD array (40-gram target) installed in the SNOLAB underground laboratory. We report dark-matter search results, including a conspicuous excess of…
▽ More
The DAMIC experiment employs large-area, thick charge-coupled devices (CCDs) to search for the interactions of low-mass dark matter particles in the galactic halo with silicon atoms in the CCD target. From 2017 to 2019, DAMIC collected data with a seven-CCD array (40-gram target) installed in the SNOLAB underground laboratory. We report dark-matter search results, including a conspicuous excess of events above the background model below 200 eV$_{\rm ee}$, whose origin remains unknown. We present details of the published spectral analysis, and update on the deployment of skipper CCDs to perform a more precise measurement by early 2023.
△ Less
Submitted 2 October, 2022;
originally announced October 2022.
-
Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection
Authors:
D. Norcini,
N. Castello-Mor,
D. Baxter,
N. J. Corso,
J. Cuevas-Zepeda,
C. De Dominicis,
A. Matalon,
S. Munagavalasa,
S. Paul,
P. Privitera,
K. Ramanathan,
R. Smida,
R. Thomas,
R. Yajur,
A. E. Chavarria,
K. McGuire,
P. Mitra,
A. Piers,
M. Settimo,
J. Cortabitarte Gutierrez,
J. Duarte-Campderros,
A. Lantero-Barreda,
A. Lopez-Virto,
I. Vila,
R. Vilar
, et al. (19 additional authors not shown)
Abstract:
Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $γ$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a…
▽ More
Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $γ$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23$\,$eV. A skipper charge-coupled device (CCD) with single-electron resolution, developed for the DAMIC-M experiment, was exposed to a $^{241}$Am $γ$-ray source over several months. Features associated with the silicon K, L$_{1}$, and L$_{2,3}$-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100$\,$eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5$\,$keV. The data are in better agreement with $ab$ $initio$ calculations originally developed for X-ray absorption spectroscopy.
△ Less
Submitted 2 July, 2022;
originally announced July 2022.
-
Snowmass 2021 White Paper: The Selena Neutrino Experiment
Authors:
A. E. Chavarria,
C. Galbiati,
B. Hernandez-Molinero,
Al. Ianni,
X. Li,
Y. Mei,
D. Montanino,
X. Ni,
C. Peña Garay,
A. Piers,
H. Wang
Abstract:
Imaging devices made from an ionization target layer of amorphous selenium (aSe) coupled to a silicon complementary metal-oxide-semiconductor (CMOS) active pixel array for charge readout are a promising technology for neutrino physics. The high spatial resolution in a solid-state target provides unparalleled rejection of backgrounds from natural radioactivity in the search for neutrinoless $ββ$ de…
▽ More
Imaging devices made from an ionization target layer of amorphous selenium (aSe) coupled to a silicon complementary metal-oxide-semiconductor (CMOS) active pixel array for charge readout are a promising technology for neutrino physics. The high spatial resolution in a solid-state target provides unparalleled rejection of backgrounds from natural radioactivity in the search for neutrinoless $ββ$ decay and for electron neutrino ($ν_e$) spectroscopy with $^{82}$Se. In this white paper, we summarize the broad scientific program of a large imaging detector with a 10-ton target of $^{82}$Se. We review the detector technology, and outline the ongoing research program to realize this experiment.
△ Less
Submitted 16 March, 2022;
originally announced March 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
The Selena Neutrino Experiment
Authors:
Alvaro E. Chavarria
Abstract:
Imaging sensors made from an ionization target layer of amorphous selenium (aSe) coupled to a silicon complementary metal-oxide-semiconductor (CMOS) active pixel array for charge readout are a promising technology for neutrino physics. The high spatial resolution in a solid-state target provides unparalleled rejection of backgrounds from natural radioactivity in the search for neutrinoless $ββ$ de…
▽ More
Imaging sensors made from an ionization target layer of amorphous selenium (aSe) coupled to a silicon complementary metal-oxide-semiconductor (CMOS) active pixel array for charge readout are a promising technology for neutrino physics. The high spatial resolution in a solid-state target provides unparalleled rejection of backgrounds from natural radioactivity in the search for neutrinoless $ββ$ decay and for solar neutrino spectroscopy with $^{82}$Se. We present results on the ionization response of aSe measured from the photoabsorption of 122 keV $γ$ rays in a single-pixel device. We report on the progress in the fabrication and testing of the first prototype imaging sensors based on the Topmetal-II$^{\rm -}$ pixelated CMOS charge readout chip. We explore the scientific reach of a large neutrino detector with the proposed technology based on our experimental understanding of the sensor performance.
△ Less
Submitted 31 October, 2021;
originally announced November 2021.
-
Characterization of the background spectrum in DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
I. Arnquist,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
N. Corso,
E. Darragh-Ford,
M. L. Di Vacri,
J. C. D'Olivo,
J. Estrada,
F. Favela-Perez,
R. Gaïor,
Y. Guardincerri,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
P. Mitra,
A. Piers,
P. Privitera,
K. Ramanathan
, et al. (9 additional authors not shown)
Abstract:
We construct the first comprehensive radioactive background model for a dark matter search with charge-coupled devices (CCDs). We leverage the well-characterized depth and energy resolution of the DAMIC at SNOLAB detector and a detailed GEANT4-based particle-transport simulation to model both bulk and surface backgrounds from natural radioactivity down to 50 eV$_{\text{ee}}$. We fit to the energy…
▽ More
We construct the first comprehensive radioactive background model for a dark matter search with charge-coupled devices (CCDs). We leverage the well-characterized depth and energy resolution of the DAMIC at SNOLAB detector and a detailed GEANT4-based particle-transport simulation to model both bulk and surface backgrounds from natural radioactivity down to 50 eV$_{\text{ee}}$. We fit to the energy and depth distributions of the observed ionization events to differentiate and constrain possible background sources, for example, bulk $^{3}$H from silicon cosmogenic activation and surface $^{210}$Pb from radon plate-out. We observe the bulk background rate of the DAMIC at SNOLAB CCDs to be as low as $3.1 \pm 0.6$ counts kg$^{-1}$ day$^{-1}$ keV$_{\text{ee}}^{-1}$, making it the most sensitive silicon dark matter detector. Finally, we discuss the properties of a statistically significant excess of events over the background model with energies below 200 eV$_{\text{ee}}$.
△ Less
Submitted 24 March, 2022; v1 submitted 25 October, 2021;
originally announced October 2021.
-
Measurement of the ionization response of amorphous selenium with 122keV $γ$ rays
Authors:
Xinran Li,
Alvaro E. Chavarria,
Snezana Bogdanovich,
Cristiano Galbiati,
Alexander Piers,
Brad Polischuk
Abstract:
We performed a measurement of the ionization response of 200 $μ$m-thick amorphous selenium (aSe) layers under drift electric fields of up to 50 V/$μ$m. The aSe target was exposed to ionizing radiation from a $^{57}$Co radioactive source and the ionization pulses were recorded with high resolution. Using the spectral line from the photoabsorption of 122 keV $γ$ rays, we measured the charge yield in…
▽ More
We performed a measurement of the ionization response of 200 $μ$m-thick amorphous selenium (aSe) layers under drift electric fields of up to 50 V/$μ$m. The aSe target was exposed to ionizing radiation from a $^{57}$Co radioactive source and the ionization pulses were recorded with high resolution. Using the spectral line from the photoabsorption of 122 keV $γ$ rays, we measured the charge yield in aSe and the line width as a function of drift electric field. From a detailed microphysics simulation of charge generation and recombination in aSe, we conclude that the strong dependence of recombination on the ionization track density provides the dominant contribution to the energy resolution in aSe. These results provide valuable input to estimate the sensitivity of a proposed next-generation search for the neutrinoless $ββ$ decay of $^{82}$Se that aims to employ imaging sensors with an active layer of aSe. We estimate the RMS line width of the integrated ionization signal from neutrinoless $ββ$ decay events (of deposited energy 3 MeV) to be 2.0% for a drift field of 50 V/$μ$m. The energy resolution can be improved to 1% by correcting for the charge yield as a function of ionization density along the imaged electron tracks.
△ Less
Submitted 21 June, 2021; v1 submitted 7 December, 2020;
originally announced December 2020.
-
Measurement of the bulk radioactive contamination of detector-grade silicon with DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
E. Darragh-Ford,
J. C. D'Olivo,
J. Estrada,
F. Favela-Perez,
R. Gaïor,
Y. Guardincerri,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
P. Mitra,
A. Piers,
P. Privitera,
K. Ramanathan,
J. Da Rocha,
Y. Sarkis,
M. Settimo
, et al. (6 additional authors not shown)
Abstract:
We present measurements of bulk radiocontaminants in the high-resistivity silicon CCDs from the DAMIC at SNOLAB experiment. We utilize the exquisite spatial resolution of CCDs to discriminate between $α$ and $β$ decays, and to search with high efficiency for the spatially-correlated decays of various radioisotope sequences. Using spatially-correlated $β$ decays, we measure a bulk radioactive conta…
▽ More
We present measurements of bulk radiocontaminants in the high-resistivity silicon CCDs from the DAMIC at SNOLAB experiment. We utilize the exquisite spatial resolution of CCDs to discriminate between $α$ and $β$ decays, and to search with high efficiency for the spatially-correlated decays of various radioisotope sequences. Using spatially-correlated $β$ decays, we measure a bulk radioactive contamination of $^{32}$Si in the CCDs of $140 \pm 30$ $μ$Bq/kg, and place an upper limit on bulk $^{210}$Pb of $< 160~μ$Bq/kg. Using similar analyses of spatially-correlated bulk $α$ decays, we set limits of $< 11$ $μ$Bq/kg (0.9 ppt) on $^{238}$U and of $< 7.3$ $μ$Bq/kg (1.8 ppt) on $^{232}$Th. The ability of DAMIC CCDs to identify and reject spatially-coincident backgrounds, particularly from $^{32}$Si, has significant implications for the next generation of silicon-based dark matter experiments, where $β$'s from $^{32}$Si decay will likely be a dominant background. This capability demonstrates the readiness of the CCD technology to achieve kg-scale dark matter sensitivity.
△ Less
Submitted 23 July, 2021; v1 submitted 25 November, 2020;
originally announced November 2020.
-
Results on Low-Mass Weakly Interacting Massive Particles from an 11 kg-day Target Exposure of DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
J. C. D'Olivo,
J. Estrada,
F. Favela-Perez,
R. Gaior,
Y. Guardincerri,
E. W. Hoppe,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
P. Mitra,
C. T. Overman,
A. Piers,
P. Privitera,
K. Ramanathan,
J. Da Rocha,
Y. Sarkis
, et al. (7 additional authors not shown)
Abstract:
We present constraints on the existence of weakly interacting massive particles (WIMPs) from an 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An exces…
▽ More
We present constraints on the existence of weakly interacting massive particles (WIMPs) from an 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An excess of ionization events is observed above the analysis threshold of 50 eV$_{\rm ee}$. While the origin of this low-energy excess requires further investigation, our data exclude spin-independent WIMP-nucleon scattering cross sections $σ_{χ-n}$ as low as $3\times 10^{-41}$ cm$^2$ for WIMPs with masses $m_χ$ from 7 to 10 GeV$c^{-2}$ . These results are the strongest constraints from a silicon target on the existence of WIMPs with $m_χ$$<$9 GeV$c^{-2}$ and are directly relevant to any dark matter interpretation of the excess of nuclear-recoil events observed by the CDMS silicon experiment in 2013.
△ Less
Submitted 25 December, 2020; v1 submitted 30 July, 2020;
originally announced July 2020.
-
Cosmogenic activation of silicon
Authors:
R. Saldanha,
R. Thomas,
R. H. M. Tsang,
A. E. Chavarria,
R. Bunker,
J. L. Burnett,
S. R. Elliott,
A. Matalon,
P. Mitra,
A. Piers,
P. Privitera,
K. Ramanathan,
R. Smida
Abstract:
The production of $^{3}$H, $^{7}$Be, and $^{22}$Na by interactions of cosmic-ray particles with silicon can produce radioactive backgrounds in detectors used to search for rare events. Through controlled irradiation of silicon CCDs and wafers with a neutron beam that mimics the cosmic-ray neutron spectrum, followed by direct counting, we determined that the production rate from cosmic-ray neutrons…
▽ More
The production of $^{3}$H, $^{7}$Be, and $^{22}$Na by interactions of cosmic-ray particles with silicon can produce radioactive backgrounds in detectors used to search for rare events. Through controlled irradiation of silicon CCDs and wafers with a neutron beam that mimics the cosmic-ray neutron spectrum, followed by direct counting, we determined that the production rate from cosmic-ray neutrons at sea level is ($112 \pm 24$) atoms/(kg day) for $^{3}$H, ($8.1 \pm 1.9 $) atoms/(kg day) for $^{7}$Be, and ($43.0 \pm 7.1 $) atoms/(kg day) for $^{22}$Na. Complementing these results with the current best estimates of activation cross sections for cosmic-ray particles other than neutrons, we obtain a total sea-level cosmic-ray production rate of ($124 \pm 24$) atoms/(kg day) for $^{3}$H, ($9.4 \pm 2.0 $) atoms/(kg day) for $^{7}$Be, and ($49.6 \pm 7.3 $) atoms/(kg day) for $^{22}$Na. These measurements will help constrain background estimates and determine the maximum time that silicon-based detectors can remain unshielded during detector fabrication before cosmogenic backgrounds impact the sensitivity of next-generation rare-event searches.
△ Less
Submitted 22 November, 2020; v1 submitted 20 July, 2020;
originally announced July 2020.
-
Constraints on Light Dark Matter Particles Interacting with Electrons from DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
E. Darragh-Ford,
J. R. T. de Mello Neto,
J. C. D'Olivo,
J. Estrada,
R. Gaïor,
Y. Guardincerri,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
V. B. B. Mello,
P. Mitra,
Y. S. Mobarak,
J. Molina,
S. Paul,
A. Piers,
P. Privitera
, et al. (9 additional authors not shown)
Abstract:
We report direct-detection constraints on light dark matter particles interacting with electrons. The results are based on a method that exploits the extremely low levels of leakage current of the DAMIC detector at SNOLAB of 2-6$\times$10$^{-22}$ A cm$^{-2}$. We evaluate the charge distribution of pixels that collect $<10~\rm{e^-}$ for contributions beyond the leakage current that may be attribute…
▽ More
We report direct-detection constraints on light dark matter particles interacting with electrons. The results are based on a method that exploits the extremely low levels of leakage current of the DAMIC detector at SNOLAB of 2-6$\times$10$^{-22}$ A cm$^{-2}$. We evaluate the charge distribution of pixels that collect $<10~\rm{e^-}$ for contributions beyond the leakage current that may be attributed to dark matter interactions. Constraints are placed on so-far unexplored parameter space for dark matter masses between 0.6 and 100 MeV$c^{-2}$. We also present new constraints on hidden-photon dark matter with masses in the range $1.2$-$30$ eV$c^{-2}$.
△ Less
Submitted 8 April, 2020; v1 submitted 29 July, 2019;
originally announced July 2019.
-
Measurement of low energy ionization signals from Compton scattering in a CCD dark matter detector
Authors:
K. Ramanathan,
A. Kavner,
A. E. Chavarria,
P. Privitera,
D. Amidei,
T. -L. Chou,
A. Matalon,
R. Thomas,
J. Estrada,
J. Tiffenberg,
J. Molina
Abstract:
An important source of background in direct searches for low-mass dark matter particles are the energy deposits by small-angle scattering of environmental $γ$ rays. We report detailed measurements of low-energy spectra from Compton scattering of $γ$ rays in the bulk silicon of a charge-coupled device (CCD). Electron recoils produced by $γ$ rays from $^{57}$Co and $^{241}$Am radioactive sources are…
▽ More
An important source of background in direct searches for low-mass dark matter particles are the energy deposits by small-angle scattering of environmental $γ$ rays. We report detailed measurements of low-energy spectra from Compton scattering of $γ$ rays in the bulk silicon of a charge-coupled device (CCD). Electron recoils produced by $γ$ rays from $^{57}$Co and $^{241}$Am radioactive sources are measured between 60 eV and 4 keV. The observed spectra agree qualitatively with theoretical predictions, and characteristic spectral features associated with the atomic structure of the silicon target are accurately measured for the first time. A theoretically-motivated parametrization of the data that describes the Compton spectrum at low energies for any incident $γ$-ray flux is derived. The result is directly applicable to background estimations for low-mass dark matter direct-detection experiments based on silicon detectors, in particular for the DAMIC experiment down to its current energy threshold.
△ Less
Submitted 19 June, 2017;
originally announced June 2017.
-
A measurement of the ionization efficiency of nuclear recoils in silicon
Authors:
F. Izraelevitch,
D. Amidei,
A. Aprahamian,
R. Arcos-Olalla,
G. Cancelo,
C. Casarella,
A. E. Chavarria,
P. Collon,
J. Estrada,
G. Fernández Moroni,
Y. Guardincerri,
G. Gutiérrez,
A. Gyurjinyan,
A. Kavner,
B. Kilminster,
A. Lathrop,
J. Liao,
Q. Liu,
M. López,
J. Molina,
P. Privitera,
M. A. Reyes,
V. Scarpine,
K. Siegl,
M. Smith
, et al. (4 additional authors not shown)
Abstract:
We have measured the ionization efficiency of silicon nuclear recoils with kinetic energy between 1.8 and 20 keV. We bombarded a silicon-drift diode with a neutron beam to perform an elastic-scattering experiment. A broad-energy neutron spectrum was used and the nuclear recoil energy was reconstructed using a measurement of the time of flight and scattering angle of the scattered neutron. The over…
▽ More
We have measured the ionization efficiency of silicon nuclear recoils with kinetic energy between 1.8 and 20 keV. We bombarded a silicon-drift diode with a neutron beam to perform an elastic-scattering experiment. A broad-energy neutron spectrum was used and the nuclear recoil energy was reconstructed using a measurement of the time of flight and scattering angle of the scattered neutron. The overall trend of the results of this work is well described by the theory of Lindhard et al. above 4 keV of recoil energy. Below this energy, the presented data shows a deviation from the model. The data indicates a faster drop than the theory prediction at low energies.
△ Less
Submitted 4 July, 2017; v1 submitted 2 February, 2017;
originally announced February 2017.
-
First Direct-Detection Constraints on eV-Scale Hidden-Photon Dark Matter with DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
B. A. Cervantes Vergara,
A. E. Chavarria,
C. R. Chavez,
J. R. T. de Mello Neto,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
R. Gaïor,
Y. Guardincerri,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
A. Letessier-Selvon,
J. Liao,
A. Matalon,
V. B. B. Mello,
J. Molina
, et al. (13 additional authors not shown)
Abstract:
We present direct detection constraints on the absorption of hidden-photon dark matter with particle masses in the range 1.2-30 eV$c^{-2}$ with the DAMIC experiment at SNOLAB. Under the assumption that the local dark matter is entirely constituted of hidden photons, the sensitivity to the kinetic mixing parameter $κ$ is competitive with constraints from solar emission, reaching a minimum value of…
▽ More
We present direct detection constraints on the absorption of hidden-photon dark matter with particle masses in the range 1.2-30 eV$c^{-2}$ with the DAMIC experiment at SNOLAB. Under the assumption that the local dark matter is entirely constituted of hidden photons, the sensitivity to the kinetic mixing parameter $κ$ is competitive with constraints from solar emission, reaching a minimum value of 2.2$\times$$10^{-14}$ at 17 eV$c^{-2}$. These results are the most stringent direct detection constraints on hidden-photon dark matter in the galactic halo with masses 3-12 eV$c^{-2}$ and the first demonstration of direct experimental sensitivity to ionization signals $<$12 eV from dark matter interactions.
△ Less
Submitted 11 April, 2017; v1 submitted 9 November, 2016;
originally announced November 2016.
-
A high-resolution CMOS imaging detector for the search of neutrinoless double $β$ decay in $^{82}$Se
Authors:
A. E. Chavarria,
C. Galbiati,
X. Li,
J. A. Rowlands
Abstract:
We introduce high-resolution solid-state imaging detectors for the search of neutrinoless double $β$ decay. Based on the present literature, imaging devices from amorphous $^{82}$Se evaporated on a complementary metal-oxide-semiconductor (CMOS) active pixel array could have the energy and spatial resolution to produce two-dimensional images of ionizing tracks of utmost quality, effectively akin to…
▽ More
We introduce high-resolution solid-state imaging detectors for the search of neutrinoless double $β$ decay. Based on the present literature, imaging devices from amorphous $^{82}$Se evaporated on a complementary metal-oxide-semiconductor (CMOS) active pixel array could have the energy and spatial resolution to produce two-dimensional images of ionizing tracks of utmost quality, effectively akin to an electronic bubble chamber in the double $β$ decay energy regime. Still to be experimentally demonstrated, a detector consisting of a large array of these devices could have very low backgrounds, possibly reaching $10^{-7}$/(kg y) in the neutrinoless decay region of interest (ROI), as it may be required for the full exploration of the neutrinoless double $β$ decay parameter space in the most unfavorable condition of a strongly quenched nucleon axial coupling constant.
△ Less
Submitted 20 March, 2017; v1 submitted 12 September, 2016;
originally announced September 2016.
-
Measurement of the low-energy quenching factor in germanium using an $^{88}$Y/Be photoneutron source
Authors:
B. J. Scholz,
A. E. Chavarria,
J. I. Collar,
P. Privitera,
A. E. Robinson
Abstract:
We employ an $^{88}$Y/Be photoneutron source to derive the quenching factor for neutron-induced nuclear recoils in germanium, probing recoil energies from a few hundred eV$_{nr}$ to 8.5keV$_{nr}$. A comprehensive Monte Carlo simulation of our setup is compared to experimental data employing a Lindhard model with a free electronic energy loss $k$ and an adiabatic correction for sub-keV$_{nr}$ nucle…
▽ More
We employ an $^{88}$Y/Be photoneutron source to derive the quenching factor for neutron-induced nuclear recoils in germanium, probing recoil energies from a few hundred eV$_{nr}$ to 8.5keV$_{nr}$. A comprehensive Monte Carlo simulation of our setup is compared to experimental data employing a Lindhard model with a free electronic energy loss $k$ and an adiabatic correction for sub-keV$_{nr}$ nuclear recoils. The best fit $k=0.179\pm 0.001$ obtained using a Monte Carlo Markov Chain (MCMC) ensemble sampler is in good agreement with previous measurements, confirming the adequacy of the Lindhard model to describe the stopping of few-keV ions in germanium crystals at a temperature of $\sim$77 K. This value of $k$ corresponds to a quenching factor of 13.7 % to 25.3 % for nuclear recoil energies between 0.3 keV$_{nr}$ and 8.5 keV$_{nr}$, respectively.
△ Less
Submitted 11 August, 2016;
originally announced August 2016.
-
Measurement of the ionization produced by sub-keV silicon nuclear recoils in a CCD dark matter detector
Authors:
A. E. Chavarria,
J. I. Collar,
J. R. Peña,
P. Privitera,
A. E. Robinson,
B. Scholz,
C. Sengul,
J. Zhou,
J. Estrada,
F. Izraelevitch,
J. Tiffenberg,
J. R. T. de Mello Neto,
D. Torres Machado
Abstract:
We report a measurement of the ionization efficiency of silicon nuclei recoiling with sub-keV kinetic energy in the bulk silicon of a charge-coupled device (CCD). Nuclear recoils are produced by low-energy neutrons ($<$24 keV) from a $^{124}$Sb-$^{9}$Be photoneutron source, and their ionization signal is measured down to 60 eV electron equivalent. This energy range, previously unexplored, is relev…
▽ More
We report a measurement of the ionization efficiency of silicon nuclei recoiling with sub-keV kinetic energy in the bulk silicon of a charge-coupled device (CCD). Nuclear recoils are produced by low-energy neutrons ($<$24 keV) from a $^{124}$Sb-$^{9}$Be photoneutron source, and their ionization signal is measured down to 60 eV electron equivalent. This energy range, previously unexplored, is relevant for the detection of low-mass dark matter particles. The measured efficiency is found to deviate from the extrapolation to low energies of the Lindhard model. This measurement also demonstrates the sensitivity to nuclear recoils of CCDs employed by DAMIC, a dark matter direct detection experiment located in the SNOLAB underground laboratory.
△ Less
Submitted 9 November, 2016; v1 submitted 2 August, 2016;
originally announced August 2016.
-
Search for low-mass WIMPs in a 0.6 kg day exposure of the DAMIC experiment at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
B. A. Cervantes Vergara,
A. E. Chavarria,
C. R. Chavez,
J. R. T. de Mello Neto,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
R. Gaïor,
Y. Guandincerri,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
A. Letessier-Selvon,
J. Liao,
J. Molina,
J. R. Peña,
P. Privitera
, et al. (13 additional authors not shown)
Abstract:
We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic…
▽ More
We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic-scattering cross section are accordingly placed. A region of parameter space relevant to the potential signal from the CDMS-II Si experiment is excluded using the same target for the first time. This result obtained with a limited exposure demonstrates the potential to explore the low-mass WIMP region (<10 GeV/$c^{2}$) of the upcoming DAMIC100, a 100 g detector currently being installed in SNOLAB.
△ Less
Submitted 9 November, 2016; v1 submitted 25 July, 2016;
originally announced July 2016.
-
The DAMIC dark matter experiment
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
D. Bole,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
A. E. Chavarria,
J. R. T. de Mello Neto,
S. Dixon,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
J. Liao,
M. López,
J. Molina,
G. Moreno-Granados,
J. Pena,
P. Privitera,
Y. Sarkis
, et al. (8 additional authors not shown)
Abstract:
The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to detect silicon recoils resulting from interactions of low mass WIMPs. In addition the CCD's high spatial resolution and the excellent energy response results in ver…
▽ More
The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to detect silicon recoils resulting from interactions of low mass WIMPs. In addition the CCD's high spatial resolution and the excellent energy response results in very effective background identification techniques. The experiment has a unique sensitivity to dark matter particles with masses below 10 GeV/c$^2$. Previous results have demonstrated the potential of this technology, motivating the construction of DAMIC100, a 100 grams silicon target detector currently being installed at SNOLAB. In this contribution, the mode of operation and unique imaging capabilities of the CCDs, and how they may be exploited to characterize and suppress backgrounds will be discussed, as well as physics results after one year of data taking.
△ Less
Submitted 7 October, 2015;
originally announced October 2015.
-
Status of the DAMIC direct dark matter search experiment
Authors:
DAMIC Collaboration,
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
D. Boule,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
A. E. Chavarría,
J. R. T. de Melo Neto,
S. Dixon,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
J. Liao,
M. López,
J. Molina,
G. Moreno-Granados,
J. Pena,
P. Privitera
, et al. (9 additional authors not shown)
Abstract:
The DAMIC experiment uses fully depleted, high resistivity CCDs to search for dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to identify and suppress radioactive backgrounds, having an unrivaled sensitivity to WIMPs with masses $<$6 GeV/$c^2$. Early results motivated the construction of a 100 g detect…
▽ More
The DAMIC experiment uses fully depleted, high resistivity CCDs to search for dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to identify and suppress radioactive backgrounds, having an unrivaled sensitivity to WIMPs with masses $<$6 GeV/$c^2$. Early results motivated the construction of a 100 g detector, DAMIC100, currently being installed at SNOLAB. This contribution discusses the installation progress, new calibration efforts near the threshold, a preliminary result with 2014 data, and the prospects for physics results after one year of data taking.
△ Less
Submitted 8 December, 2015; v1 submitted 30 September, 2015;
originally announced October 2015.
-
Measurement of radioactive contamination in the high-resistivity silicon CCDs of the DAMIC experiment
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
D. Bole,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
A. E. Chavarria,
J. R. T. de Mello Neto,
S. Dixon,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
J. Liao,
M. López,
J. Molina,
G. Moreno-Granados,
J. Pena,
P. Privitera,
Y. Sarkis
, et al. (8 additional authors not shown)
Abstract:
We present measurements of radioactive contamination in the high-resistivity silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search for dark matter particles. Novel analysis methods, which exploit the unique spatial resolution of CCDs, were developed to identify $α$ and $β$ particles. Uranium and thorium contamination in the CCD bulk was measured through $α$ spectroscopy, wit…
▽ More
We present measurements of radioactive contamination in the high-resistivity silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search for dark matter particles. Novel analysis methods, which exploit the unique spatial resolution of CCDs, were developed to identify $α$ and $β$ particles. Uranium and thorium contamination in the CCD bulk was measured through $α$ spectroscopy, with an upper limit on the $^{238}$U ($^{232}$Th) decay rate of 5 (15) kg$^{-1}$ d$^{-1}$ at 95% CL. We also searched for pairs of spatially correlated electron tracks separated in time by up to tens of days, as expected from $^{32}$Si-$^{32}$P or $^{210}$Pb-$^{210}$Bi sequences of $β$ decays. The decay rate of $^{32}$Si was found to be $80^{+110}_{-65}$ kg$^{-1}$ d$^{-1}$ (95% CI). An upper limit of $\sim$35 kg$^{-1}$ d$^{-1}$ (95% CL) on the $^{210}$Pb decay rate was obtained independently by $α$ spectroscopy and the $β$ decay sequence search. These levels of radioactive contamination are sufficiently low for the successful operation of CCDs in the forthcoming 100 g DAMIC detector.
△ Less
Submitted 9 July, 2015; v1 submitted 8 June, 2015;
originally announced June 2015.