-
Measurement of the Principal Quantum Number Distribution in a Beam of Antihydrogen Atoms
Authors:
B. Kolbinger,
C. Amsler,
S. Arguedas Cuendis,
H. Breuker,
A. Capon,
G. Costantini,
P. Dupré,
M. Fleck,
A. Gligorova,
H. Higaki,
Y. Kanai,
V. Kletzl,
N. Kuroda,
A. Lanz,
M. Leali,
V. Mäckel,
C. Malbrunot,
V. Mascagna,
O. Massiczek,
Y. Matsuda,
D. J. Murtagh,
Y. Nagata,
A. Nanda,
L. Nowak,
B. Radics
, et al. (13 additional authors not shown)
Abstract:
The ASACUSA (Atomic Spectroscopy And Collisions Using Slow Antiprotons) collaboration plans to measure the ground-state hyperfine splitting of antihydrogen in a beam at the CERN Antiproton Decelerator with initial relative precision of 10-6 or better, to test the fundamental CPT (combination of charge conjugation, parity transformation and time reversal) symmetry between matter and antimatter. Thi…
▽ More
The ASACUSA (Atomic Spectroscopy And Collisions Using Slow Antiprotons) collaboration plans to measure the ground-state hyperfine splitting of antihydrogen in a beam at the CERN Antiproton Decelerator with initial relative precision of 10-6 or better, to test the fundamental CPT (combination of charge conjugation, parity transformation and time reversal) symmetry between matter and antimatter. This challenging goal requires a polarised antihydrogen beam with a sufficient number of antihydrogen atoms in the ground state. The first measurement of the quantum state distribution of antihydrogen atoms in a low magnetic field environment of a few mT is described. Furthermore, the data-driven machine learning analysis to identify antihydrogen events is discussed.
△ Less
Submitted 19 November, 2020; v1 submitted 10 August, 2020;
originally announced August 2020.
-
AdVersarial: Perceptual Ad Blocking meets Adversarial Machine Learning
Authors:
Florian Tramèr,
Pascal Dupré,
Gili Rusak,
Giancarlo Pellegrino,
Dan Boneh
Abstract:
Perceptual ad-blocking is a novel approach that detects online advertisements based on their visual content. Compared to traditional filter lists, the use of perceptual signals is believed to be less prone to an arms race with web publishers and ad networks. We demonstrate that this may not be the case. We describe attacks on multiple perceptual ad-blocking techniques, and unveil a new arms race t…
▽ More
Perceptual ad-blocking is a novel approach that detects online advertisements based on their visual content. Compared to traditional filter lists, the use of perceptual signals is believed to be less prone to an arms race with web publishers and ad networks. We demonstrate that this may not be the case. We describe attacks on multiple perceptual ad-blocking techniques, and unveil a new arms race that likely disfavors ad-blockers. Unexpectedly, perceptual ad-blocking can also introduce new vulnerabilities that let an attacker bypass web security boundaries and mount DDoS attacks.
We first analyze the design space of perceptual ad-blockers and present a unified architecture that incorporates prior academic and commercial work. We then explore a variety of attacks on the ad-blocker's detection pipeline, that enable publishers or ad networks to evade or detect ad-blocking, and at times even abuse its high privilege level to bypass web security boundaries.
On one hand, we show that perceptual ad-blocking must visually classify rendered web content to escape an arms race centered on obfuscation of page markup. On the other, we present a concrete set of attacks on visual ad-blockers by constructing adversarial examples in a real web page context. For seven ad-detectors, we create perturbed ads, ad-disclosure logos, and native web content that misleads perceptual ad-blocking with 100% success rates. In one of our attacks, we demonstrate how a malicious user can upload adversarial content, such as a perturbed image in a Facebook post, that fools the ad-blocker into removing another users' non-ad content.
Moving beyond the Web and visual domain, we also build adversarial examples for AdblockRadio, an open source radio client that uses machine learning to detects ads in raw audio streams.
△ Less
Submitted 26 August, 2019; v1 submitted 7 November, 2018;
originally announced November 2018.
-
Hyperfine spectroscopy of hydrogen and antihydrogen in ASACUSA
Authors:
E. Widmann,
C. Amsler,
S. Arguedas Cuendis,
H. Breuker,
M. Diermaier,
P. Dupré,
C. Evans,
M. Fleck,
A. Gligorova,
H. Higaki,
Y. Kanai,
B. Kolbinger,
N. Kuroda,
M. Leali,
A. M. M. Leite,
V. Mäckel,
C. Malbrunot,
V. Mascagna,
O. Massiczek,
Y. Matsuda,
D. J. Murtagh,
Y. Nagata,
A. Nanda,
D. Phan,
C. Sauerzopf
, et al. (9 additional authors not shown)
Abstract:
The ASACUSA collaboration at the Antiproton Decelerator of CERN aims at a precise measurement of the antihydrogen ground-state hyperfine structure as a test of the fundamental CPT symmetry. A beam of antihydrogen atoms is formed in a CUSP trap, undergoes Rabi-type spectroscopy and is detected downstream in a dedicated antihydrogen detector. In parallel measurements using a polarized hydrogen beam…
▽ More
The ASACUSA collaboration at the Antiproton Decelerator of CERN aims at a precise measurement of the antihydrogen ground-state hyperfine structure as a test of the fundamental CPT symmetry. A beam of antihydrogen atoms is formed in a CUSP trap, undergoes Rabi-type spectroscopy and is detected downstream in a dedicated antihydrogen detector. In parallel measurements using a polarized hydrogen beam are being performed to commission the spectroscopy apparatus and to perform measurements of parameters of the Standard Model Extension (SME). The current status of antihydrogen spectroscopy is reviewed and progress of ASACUSA is presented.
△ Less
Submitted 16 December, 2018; v1 submitted 4 September, 2018;
originally announced September 2018.
-
Sub-Doppler frequency metrology in HD for test of fundamental physics
Authors:
F. M. J. Cozijn,
P. Dupre,
E. J. Salumbides,
K. S. E. Eikema,
W. Ubachs
Abstract:
Weak transitions in the (2,0) overtone band of the HD molecule at $λ= 1.38 \, μ$m were measured in saturated absorption using the technique of noise-immune cavity-enhanced optical heterodyne molecular spectroscopy. Narrow Doppler-free lines were interrogated with a spectroscopy laser locked to a frequency comb laser referenced to an atomic clock to yield transition frequencies [R(1) =…
▽ More
Weak transitions in the (2,0) overtone band of the HD molecule at $λ= 1.38 \, μ$m were measured in saturated absorption using the technique of noise-immune cavity-enhanced optical heterodyne molecular spectroscopy. Narrow Doppler-free lines were interrogated with a spectroscopy laser locked to a frequency comb laser referenced to an atomic clock to yield transition frequencies [R(1) = $217\,105\,181\,895\,(20)$ kHz; R(2) = $219\,042\,856\,621\,(28)$ kHz; R(3) = $220\,704\,304\,951\,(28)$ kHz] at three orders of magnitude improved accuracy. These benchmark values provide a test of QED in the smallest neutral molecule, and open up an avenue to resolve the proton radius puzzle, as well as constrain putative fifth forces and extra dimensions.
△ Less
Submitted 22 December, 2017;
originally announced December 2017.
-
The ASACUSA antihydrogen and hydrogen program : results and prospects
Authors:
C. Malbrunot,
C. Amsler,
S. Arguedas Cuendi,
H. Breuker,
P. Dupre,
M. Fleck,
H. Higaki,
Y. Kanai,
T. Kobayashi,
B. Kolbinger,
N. Kuroda,
M. Leali,
V. Maeckel,
V. Mascagna,
O. Massiczek,
Y. Matsuda,
Y. Nagata,
M. C. Simon,
H. Spitzer,
M. Tajima,
S. Ulmer,
L. Venturelli,
E. Widmann,
M. Wiesinger,
Y. Yamazaki
, et al. (1 additional authors not shown)
Abstract:
The goal of the ASACUSA-CUSP collaboration at the Antiproton Decelerator of CERN is to measure the ground-state hyperfine splitting of antihydrogen using an atomic spectroscopy beamline. A milestone was achieved in 2012 through the detection of 80 antihydrogen atoms 2.7 meters away from their production region. This was the first observation of "cold" antihydrogen atoms in a magnetic field free re…
▽ More
The goal of the ASACUSA-CUSP collaboration at the Antiproton Decelerator of CERN is to measure the ground-state hyperfine splitting of antihydrogen using an atomic spectroscopy beamline. A milestone was achieved in 2012 through the detection of 80 antihydrogen atoms 2.7 meters away from their production region. This was the first observation of "cold" antihydrogen atoms in a magnetic field free region. In parallel to the progress on the antihydrogen production, the spectroscopy beamline was tested with a source of hydrogen. This led to a measurement at a relative precision of 2.7x 10^(-9) which constitues the most precise measurement of the hydrogen hyperfine splitting in a beam. Further measurements with an upgraded hydrogen apparatus are motivated by CPT and Lorentz violation tests in the framework of the Standard Model Extension. Unlike for hydrogen, the antihydrogen experiment is complicated by the difficulty of synthesizing enough cold antiatoms in ground-state. The first antihydrogen quantum states scan at the entrance of the spectroscopy apparatus was realized in 2016 and is presented here. The prospects for a ppm measurement are also discussed.
△ Less
Submitted 9 October, 2017;
originally announced October 2017.
-
Towards Measuring the Ground State Hyperfine Splitting of Antihydrogen -- A Progress Report
Authors:
C. Sauerzopf,
A. Capon,
M. Diermaier,
P. Dupré,
Y. Higashi,
C. Kaga,
B. Kolbinger,
M. Leali,
S. Lehner,
E. Lodi Rizzini,
C. Malbrunot,
V. Mascagna,
O. Massiczek,
D. J. Murtagh,
Y. Nagata,
B. Radics,
M. C. Simon,
K. Suzuki,
M. Tajima,
S. Ulmer,
S. Vamosi,
S. van Gorp,
J. Zmeskal,
H. Breuker,
H. Higaki
, et al. (6 additional authors not shown)
Abstract:
We report the successful commissioning and testing of a dedicated field-ioniser chamber for measuring principal quantum number distributions in antihydrogen as part of the ASACUSA hyperfine spectroscopy apparatus. The new chamber is combined with a beam normalisation detector that consists of plastic scintillators and a retractable passivated implanted planar silicon (PIPS) detector.
We report the successful commissioning and testing of a dedicated field-ioniser chamber for measuring principal quantum number distributions in antihydrogen as part of the ASACUSA hyperfine spectroscopy apparatus. The new chamber is combined with a beam normalisation detector that consists of plastic scintillators and a retractable passivated implanted planar silicon (PIPS) detector.
△ Less
Submitted 6 June, 2016;
originally announced June 2016.