Excited State Muon Transfer in Hydrogen/Deuterium Mixtures
Authors:
B. Lauss,
P. Ackerbauer,
W. H. Breunlich,
B. Gartner,
M. Jeitler,
P. Kammel,
J. Marton,
W. Prymas,
J. Zmeskal,
D. Chatellard,
J. -P. Egger,
E. Jeannet,
H. Daniel,
F. J. Hartmann,
A. Kosak,
C. Petitjean
Abstract:
We report the first direct observation of excited state muon transfer in hydrogen/deuterium mixtures by direct measurement of q_1s, the probability that a mu-p atom, which is initially formed in an excited state, reaches the 1s ground state. The dependence of q_1s on deuterium concentration c_d was measured for two different densities at cryogenic temperatures using charge coupled devices (CCDs)…
▽ More
We report the first direct observation of excited state muon transfer in hydrogen/deuterium mixtures by direct measurement of q_1s, the probability that a mu-p atom, which is initially formed in an excited state, reaches the 1s ground state. The dependence of q_1s on deuterium concentration c_d was measured for two different densities at cryogenic temperatures using charge coupled devices (CCDs) to detect the muonic X rays. First results based on the analysis of the K_alpha-lines of the two isotopes are presented.
△ Less
Submitted 19 September, 1997;
originally announced September 1997.
X-ray emission during the muonic cascade in hydrogen
Authors:
B. Lauss,
P. Ackerbauer,
W. H. Breunlich,
B. Gartner,
M. Jeitler,
P. Kammel,
J. Marton,
W. Prymas,
J. Zmeskal,
D. Chatellard,
J. -P. Egger,
E. Jeannet,
H. Daniel,
F. J. Hartmann,
A. Kosak,
C. Petitjean
Abstract:
We report our investigations of X rays emitted during the muonic cascade in hydrogen employing charge coupled devices as X-ray detectors. The density dependence of the relative X-ray yields for the muonic hydrogen lines (K_alpha, K_beta, K_gamma) has been measured at densities between 0.00115 and 0.97 of liquid hydrogen density. In this density region collisional processes dominate the cascade d…
▽ More
We report our investigations of X rays emitted during the muonic cascade in hydrogen employing charge coupled devices as X-ray detectors. The density dependence of the relative X-ray yields for the muonic hydrogen lines (K_alpha, K_beta, K_gamma) has been measured at densities between 0.00115 and 0.97 of liquid hydrogen density. In this density region collisional processes dominate the cascade down to low energy levels. A comparison with recent calculations is given in order to demonstrate the influence of Coulomb deexcitation.
△ Less
Submitted 19 September, 1997;
originally announced September 1997.