Diagnostics of charge breeder electron cyclotron resonance ion source plasma with consecutive transients method
Authors:
Julien Angot,
Olli Tarvainen,
Hannu Koivisto,
Miha Luntinen,
Thomas Thuillier,
Ville Toivanen
Abstract:
The consecutive transients (CT) method is a diagnostics approach combining experimental and computational techniques to probe the plasma parameters of Charge Breeder Electron Cyclotron Resonance Ion Sources (CB-ECRIS). The method is based on short pulse injection of singly charged ions into the charge breeder plasma, and the measurement of the resulting transients of the charge bred multiply charg…
▽ More
The consecutive transients (CT) method is a diagnostics approach combining experimental and computational techniques to probe the plasma parameters of Charge Breeder Electron Cyclotron Resonance Ion Sources (CB-ECRIS). The method is based on short pulse injection of singly charged ions into the charge breeder plasma, and the measurement of the resulting transients of the charge bred multiply charged ions. Estimates for plasma density, average electron energy and characteristic times of ion confinement, electron impact ionization and charge exchange are then computationally derived from the experimental data. Here the CT method is applied for parametric studies of CBECRIS plasma. Potassium ions were charge bred with hydrogen support plasma, and the effects of varied microwave power, neutral gas pressure and magnetic field strength on the plasma parameters and charge breeding efficiency are presented. It is shown that the method is sufficiently sensitive to provide relevant information on changing plasma conditions with the control parameters. The neutral gas pressure had the strongest impact on the plasma parameters, and the results agree with trends obtained by using other diagnostic methods, e.g. the increase of plasma density with increased neutral gas pressure. Furthermore, the method can provide information inaccessible with other methods, such as the characteristic times of ion confinement, ionization and charge exchange, and the hierarchy between them. The results show that the peak charge breeding efficiency is obtained for the highest ion charge state for which the ionization time remains shorter than the charge exchange and the ion confinement times.
△ Less
Submitted 17 October, 2023;
originally announced October 2023.
-
Method for estimating charge breeder ECR ion source plasma parameters with short pulse 1+ injection
Authors:
J. Angot,
M. Luntinen,
T. Kalvas,
H. Koivisto,
R. Kronholm,
L. Maunoury,
O. Tarvainen,
T. Thuillier,
V. Toivanen
Abstract:
A new method for determining plasma parameters from beam current transients resulting from short pulse 1+ injection into a Charge Breeder Electron Cyclotron Resonance Ion Source (CB-ECRIS) has been developed. The proposed method relies on few assumptions, and yields the ionisation times $1/n_e\left\langleσv\right\rangle^{\text{inz}}_{q\to q+1}$, charge exchange times…
▽ More
A new method for determining plasma parameters from beam current transients resulting from short pulse 1+ injection into a Charge Breeder Electron Cyclotron Resonance Ion Source (CB-ECRIS) has been developed. The proposed method relies on few assumptions, and yields the ionisation times $1/n_e\left\langleσv\right\rangle^{\text{inz}}_{q\to q+1}$, charge exchange times $1/n_0\left\langleσv\right\rangle^{\text{cx}}_{q\to q-1}$, the ion confinement times $τ^q$, as well as the plasma energy contents $n_e\left\langle E_e\right\rangle$ and the plasma triple products $n_e \left\langle E_e\right\rangle τ^q$. The method is based on fitting the current balance equation on the extracted beam currents of high charge state ions, and using the fitting coefficients to determine the postdictions for the plasma parameters via an optimisation routine.
The method has been applied for the charge breeding of injected K$^+$ ions in helium plasma. It is shown that the confinement times of K$^{q+}$ charge states range from 2.6$^{+0.8}_{-0.4}$ ms to 16.4$^{+18.3}_{-6.8}$ ms increasing with the charge state. The ionisation and charge exchange times for the high charge state ions are 2.6$^{+0.5}_{-0.5}$ ms--12.6$^{+2.6}_{-3.2}$ ms and 3.7$^{+5.0}_{-1.6}$ ms--357.7$^{+406.7}_{-242.4}$ ms, respectively. The plasma energy content is found to be $2.5^{+4.3}_{-1.8}\times 10^{15}$ eV/cm$^3$.
△ Less
Submitted 5 March, 2021;
originally announced March 2021.
-
Controlled turbulence regime of electron cyclotron resonance ion source for improved multicharged ion performance
Authors:
V. A. Skalyga,
I. V. Izotov,
A. G. Shalashov,
E. D. Gospodchikov,
E. M. Kiseleva,
O. Tarvainen,
H. Koivisto,
V. Toivanen
Abstract:
Fundamental studies of excitation and non-linear evolution of kinetic instabilities of strongly nonequlibrium hot plasmas confined in open magnetic traps suggest new opportunities for fine-tuning of conventional electron cyclotron resonance (ECR) ion sources. These devices are widely used for the production of particle beams of high charge state ions. Operating the ion source in controlled turbule…
▽ More
Fundamental studies of excitation and non-linear evolution of kinetic instabilities of strongly nonequlibrium hot plasmas confined in open magnetic traps suggest new opportunities for fine-tuning of conventional electron cyclotron resonance (ECR) ion sources. These devices are widely used for the production of particle beams of high charge state ions. Operating the ion source in controlled turbulence regime allows increasing the absorbed power density and therefore the volumetric plasma energy content in the dense part of the discharge surrounded by the ECR surface, which leads to enhanced beam currents of high charge state ions. We report experiments at the ECR ion source at the JYFL accelerator laboratory, in which adopting of a new approach allows to increase the multicharged ion beam current up to two times, e.g. to 95 $μ$A of O$^{7+}$ achieved with mere 280 W power at 11.56 GHz. A theoretical model supporting and explaining the experimental findings is presented. The study suggests that the controlled turbulence regime has the potential to enhance the beam currents of modern high-performance ion sources, including state-of-the-art superconducting devices.
△ Less
Submitted 9 February, 2021; v1 submitted 20 November, 2020;
originally announced November 2020.
-
Experimental evidence on photo-assisted O$^-$ ion production from Al$_2$O$_3$ cathode in cesium sputter negative ion source
Authors:
O. Tarvainen,
R. Kronholm,
M. Laitinen,
M. Reponen,
J. Julin,
V. Toivanen,
M. Napari,
M. Marttinen,
D. Faircloth,
H. Koivisto,
T. Sajavaara
Abstract:
The production of negative ions in cesium sputter ion sources is generally considered to be a pure surface process. It has been recently proposed that ion pair production could explain the higher-than-expected beam currents extracted from these ion sources, therefore opening the door for laser-assisted enhancement of the negative ion yield. We have tested this hypothesis by measuring the effect of…
▽ More
The production of negative ions in cesium sputter ion sources is generally considered to be a pure surface process. It has been recently proposed that ion pair production could explain the higher-than-expected beam currents extracted from these ion sources, therefore opening the door for laser-assisted enhancement of the negative ion yield. We have tested this hypothesis by measuring the effect of various pulsed diode lasers on the O$^-$ beam current produced from Al$_2$O$_3$ cathode of a cesium sputter ion source. It is expected that the ion pair production of O$^-$ requires populating the 5d electronic states of neutral cesium, thus implying that the process should be provoked only with specific wavelengths. Our experimental results provide evidence for the existence of a wavelength-dependent photo-assisted effect but cast doubt on its alleged resonant nature as the prompt enhancement of beam current can be observed with laser wavelengths exceeding a threshold photon energy. The beam current transients observed during the laser pulses suggest that the magnitude and longevity of the beam current enhancement depends on the cesium balance on the cathode surface. We conclude that the photo-assisted negative ion production could be of practical importance as it can more than double the extracted beam current under certain operational settings of the ion source.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Design of a 10 GHz minimum-B quadrupole permanent magnet electron cyclotron resonance ion source
Authors:
T. Kalvas,
O. Tarvainen,
V. Toivanen,
H. Koivisto
Abstract:
This paper presents a simulation study of a permanent magnet electron cyclotron resonance ion source (ECRIS) with a minimum-B quadrupole magnetic field topology. The magnetic field is made to conform to conventional ECRIS with $B_\textrm{min}/B_\textrm{ECR}$ of 0.67 and a last closed magnetic isosurface of 1.86$B_\textrm{ECR}$ at 10 GHz. The distribution of magnetic field gradients parallel to the…
▽ More
This paper presents a simulation study of a permanent magnet electron cyclotron resonance ion source (ECRIS) with a minimum-B quadrupole magnetic field topology. The magnetic field is made to conform to conventional ECRIS with $B_\textrm{min}/B_\textrm{ECR}$ of 0.67 and a last closed magnetic isosurface of 1.86$B_\textrm{ECR}$ at 10 GHz. The distribution of magnetic field gradients parallel to the field, affecting the electron heating efficiency, cover a range from 0 to 13 T/m, being similar to conventional ECRIS. Therefore it is expected that the novel ion source produces warm electrons and high charge state ions in significant number. Single electron tracking simulations are used to estimate plasma flux distribution on the plasma chamber walls and to provide an estimate of the ion density profile at the extraction slit then used in ion optical simulations demonstrating high transmission through the low energy beam transport. The designed ion source is intended to study if the quadrupole field topology could produce high charge state beams in comparable intensities to conventional ECRIS and efficiently transport them through a low energy beamline, thus paving the way for a superconducting ARC-ECRIS using the same field topology. Furthermore, the prospects of the presented ion source design as an injector of a single-ended accelerator for ion beam analysis are discussed.
△ Less
Submitted 21 April, 2020;
originally announced April 2020.
-
Measurements of the energy distribution of electrons lost from the minimum B-field -- the effect of instabilities and two-frequency heating
Authors:
Ivan Izotov,
Olli Tarvainen,
Vadim Skalyga,
Dmitry Mansfeld,
Hannu Koivisto,
Risto Kronholm,
Ville Toivanen,
Vladimir Mironov
Abstract:
Further progress in the development of ECR ion sources (ECRIS) requires deeper understanding of the underlying physics. One of the topics that remains obscure, though being crucial for the performance of the ECRIS, is the electron energy distribution (EED). A well-developed technique of measuring the EED of electrons escaping axially from the magnetically confined plasma of an ECRIS was used for t…
▽ More
Further progress in the development of ECR ion sources (ECRIS) requires deeper understanding of the underlying physics. One of the topics that remains obscure, though being crucial for the performance of the ECRIS, is the electron energy distribution (EED). A well-developed technique of measuring the EED of electrons escaping axially from the magnetically confined plasma of an ECRIS was used for the study of EED in unstable mode of plasma confinement, i.e. in the presence of kinetic instabilities. The experimental data were recorded for pulsed and CW discharges with a room-temperature 14 GHz ECRIS at the JYFL accelerator laboratory. The measurements were focused on observing differences between the EED escaping from a stable and unstable plasmas. It was found that nonlinear phenomena alter the EED noticeably. The electron losses are enhanced in both unstable regime and with two-frequency heating suppressing the instabilities. It has been shown earlier that two-frequency heating boosts the ECRIS performance presumably owing to the suppression of instabilities. We report the observed changes in EED introduced by the secondary frequency in different regimes, including an off-resonance condition where the secondary frequency is lower than the minimum frequency satisfying the resonance condition for cold electrons at the magnetic field minimum. Finally, we suggest an experimental method of qualitative evaluation of the energy distribution of electrons confined in the magnetic trap using a method of measuring energy distribution of lost electrons during the plasma decay in pulsed operation of the ion source.
△ Less
Submitted 10 December, 2019;
originally announced December 2019.
-
The role of rf-scattering in high-energy electron losses from minimum-B ECR ion source
Authors:
I. V. Izotov,
A. G. Shalashov,
V. A. Skalyga,
E. D. Gospodchikov,
O. Tarvainen,
V. E. Mironov,
H. Koivisto,
R. Kronholm,
V. Toivanen,
B. Bhaskar
Abstract:
The measurement of the axially lost electron energy distribution escaping from a minimum-B electron cyclotron resonance ion source in the range of 4-800 keV is reported. The experiments have revealed the existence of a hump at 150-300 keV energy, containing up to 15% of the lost electrons and carrying up to 30% of the measured energy losses. The mean energy of the hump is independent of the microw…
▽ More
The measurement of the axially lost electron energy distribution escaping from a minimum-B electron cyclotron resonance ion source in the range of 4-800 keV is reported. The experiments have revealed the existence of a hump at 150-300 keV energy, containing up to 15% of the lost electrons and carrying up to 30% of the measured energy losses. The mean energy of the hump is independent of the microwave power, frequency and neutral gas pressure but increases with the magnetic field strength, most importantly with the value of the minimum-B field. Experiments in pulsed operation mode have indicated the presence of the hump only when microwave power is applied, confirming that the origin of the hump is rf-induced momentum space diffusion. Possible mechanism of the hump formation is considered basing on the quasi-linear model of plasma-wave interaction.
△ Less
Submitted 8 December, 2020; v1 submitted 9 December, 2019;
originally announced December 2019.
-
Measurement of the energy distribution of electrons escaping minimum-B ECR plasmas
Authors:
Ivan Izotov,
Olli Tarvainen,
Vadim Skalyga,
Dmitry Mansfeld,
Taneli Kalvas,
Hannu Koivisto,
Risto Kronholm
Abstract:
The measurement of the electron energy distribution (EED) of electrons escaping axially from a minimum-B electron cyclotron resonance ion source (ECRIS) is reported. The experimental data were recorded with a room-temperature 14 GHz ECRIS at the JYFL accelerator laboratory. The electrons escaping through the extraction mirror of the ion source were detected with a secondary electron amplifier plac…
▽ More
The measurement of the electron energy distribution (EED) of electrons escaping axially from a minimum-B electron cyclotron resonance ion source (ECRIS) is reported. The experimental data were recorded with a room-temperature 14 GHz ECRIS at the JYFL accelerator laboratory. The electrons escaping through the extraction mirror of the ion source were detected with a secondary electron amplifier placed downstream from a dipole magnet serving as an electron spectrometer with 500 eV resolution. It was discovered that the EED in the range of 5 - 250 keV is strongly non-Maxwellian and exhibits several local maxima below 20 keV energy. It was observed that the most influential ion source operating parameter on the EED is the magnetic field strength, which affected the EED predominantly at energies less than 100 keV. The effects of the microwave power and frequency, ranging from 100 to 600 W and 11 to 14 GHz respectively, on the EED were found to be less significant. The presented technique and experiments enable the comparison between direct measurement of the EED and results derived from bremsstrahlung diagnostics, the latter being severely complicated by the non-Maxwellian nature of the EED reported here. The role of RF pitch angle scattering on electron losses and the relation between the EED of the axially escaping electrons and the EED of the confined electrons are discussed.
△ Less
Submitted 15 November, 2017;
originally announced November 2017.
-
VUV irradiance measurement of a 2.45 GHz microwave-driven hydrogen discharge
Authors:
J. Komppula,
O. Tarvainen,
T. Kalvas,
H. Koivisto,
R. Kronholm,
J. Laulainen,
P. Myllyperkiö
Abstract:
Absolute values of VUV-emission of a 2.45 GHz microwave-driven hydrogen discharge are reported. The measurements were performed with a robust and straightforward method based on a photodiode and optical filters. It was found that the volumetric photon emission rate in the VUV-range (80-250 nm) is $10^{16}$-$10^{17}$ 1/cm$^3$s, which corresponds to approximately 8% dissipation of injected microwave…
▽ More
Absolute values of VUV-emission of a 2.45 GHz microwave-driven hydrogen discharge are reported. The measurements were performed with a robust and straightforward method based on a photodiode and optical filters. It was found that the volumetric photon emission rate in the VUV-range (80-250 nm) is $10^{16}$-$10^{17}$ 1/cm$^3$s, which corresponds to approximately 8% dissipation of injected microwave power by VUV photon emission. The volumetric emission of characteristic emission bands was utilized to diagnostics of molecular plasma processes including volumetric rates of ionization, dissociation and excitation to high vibrational levels and metastable states. The estimated reaction rates imply that each injected molecule experiences several inelastic electron impact collisions. The upper limit for the total density of metastable neutrals ($2S$ atoms and $c^3Π_u$ molecules) was estimated to be approximately 0.5% of the neutral gas density.
△ Less
Submitted 8 October, 2015;
originally announced October 2015.
-
Photoelectron Emission from Metal Surfaces Induced by Radiation Emitted by a 14 GHz Electron Cyclotron Resonance Ion Source
Authors:
Janne Laulainen,
Taneli Kalvas,
Hannu Koivisto,
Jani Komppula,
Risto Kronholm,
Olli Tarvainen
Abstract:
Photoelectron emission measurements have been performed using a room-temperature 14 GHz ECR ion source. It is shown that the photoelectron emission from Al, Cu, and stainless steel (SAE 304) surfaces, which are common plasma chamber materials, is predominantly caused by radiation emitted from plasma with energies between 8 eV and 1 keV. Characteristic X-ray emission and bremsstrahlung from plasma…
▽ More
Photoelectron emission measurements have been performed using a room-temperature 14 GHz ECR ion source. It is shown that the photoelectron emission from Al, Cu, and stainless steel (SAE 304) surfaces, which are common plasma chamber materials, is predominantly caused by radiation emitted from plasma with energies between 8 eV and 1 keV. Characteristic X-ray emission and bremsstrahlung from plasma have a negligible contribution to the photoelectron emission. It is estimated from the measured data that the maximum conceivable photoelectron flux from plasma chamber walls is on the order of 10 % of the estimated total electron losses from the plasma.
△ Less
Submitted 1 September, 2015;
originally announced September 2015.
-
Photoelectron Emission from Metal Surfaces Induced by VUV-emission of Filament Driven Hydrogen Arc Discharge Plasma
Authors:
J. Laulainen,
T. Kalvas,
H. Koivisto,
J. Komppula,
O. Tarvainen
Abstract:
Photoelectron emission measurements have been performed using a filament-driven multi-cusp arc discharge volume production H^- ion source (LIISA). It has been found that photoelectron currents obtained with Al, Cu, Mo, Ta and stainless steel (SAE 304) are on the same order of magnitude. The photoelectron currents depend linearly on the discharge power. It is shown experimentally that photoelectron…
▽ More
Photoelectron emission measurements have been performed using a filament-driven multi-cusp arc discharge volume production H^- ion source (LIISA). It has been found that photoelectron currents obtained with Al, Cu, Mo, Ta and stainless steel (SAE 304) are on the same order of magnitude. The photoelectron currents depend linearly on the discharge power. It is shown experimentally that photoelectron emission is significant only in the short wavelength range of hydrogen spectrum due to the energy dependence of the quantum efficiency. It is estimated from the measured data that the maximum photoelectron flux from plasma chamber walls is on the order of 1 A per kW of discharge power.
△ Less
Submitted 27 March, 2015;
originally announced March 2015.
-
An Experimental Study of Waveguide Coupled Microwave Heating with Conventional Multicusp Negative Ion Source
Authors:
J. Komppula,
T. Kalvas,
H. Koivisto,
J. Laulainen,
O. Tarvainen
Abstract:
Negative ion production with conventional multicusp plasma chambers utilizing 2.45 GHz microwave heating is demonstrated. The experimental results were obtained with the multicusp plasma chambers and extraction systems of the RFdriven RADIS ion source and the filament driven arc discharge ion source LIISA. A waveguide microwave coupling system, which is almost similar to the one used with the SILH…
▽ More
Negative ion production with conventional multicusp plasma chambers utilizing 2.45 GHz microwave heating is demonstrated. The experimental results were obtained with the multicusp plasma chambers and extraction systems of the RFdriven RADIS ion source and the filament driven arc discharge ion source LIISA. A waveguide microwave coupling system, which is almost similar to the one used with the SILHI ion source, was used. The results demonstrate that at least one third of negative ion beam obtained with inductive RF-coupling (RADIS) or arc discharge (LIISA) can be achieved with 1 kW of 2.45 GHz microwave power in CW mode without any modification of the plasma chamber. The co-extracted electron to H^- ratio and the optimum pressure range were observed to be similar for both heating methods. The behaviour of the plasma implies that the energy transfer from the microwaves to the plasma electrons is mainly an off-resonance process.
△ Less
Submitted 27 March, 2015;
originally announced March 2015.
-
E-sail test payload of ESTCube-1 nanosatellite
Authors:
Jouni Envall,
Pekka Janhunen,
Petri Toivanen,
Mihkel Pajusalu,
Erik Ilbis,
Jaanus Kalde,
Matis Averin,
Henri Kuuste,
Kaspars Laizans,
Viljo Allik,
Timo Rauhala,
Henri Seppänen,
Sergiy Kiprich,
Jukka Ukkonen,
Edward Haeggström,
Taneli Kalvas,
Olli Tarvainen,
Janne Kauppinen,
Antti Nuottajärvi,
Hannu Koivisto
Abstract:
The scientific mission of ESTCube-1, launched in May 2013, is to measure the Electric solar wind sail (E-sail) force in orbit. The experiment is planned to push forward the development of E-sail, a propulsion method recently invented at the Finnish Meteorological Institute. E-sail is based on extracting momentum from the solar wind plasma flow by using long thin electrically charged tethers. ESTCu…
▽ More
The scientific mission of ESTCube-1, launched in May 2013, is to measure the Electric solar wind sail (E-sail) force in orbit. The experiment is planned to push forward the development of E-sail, a propulsion method recently invented at the Finnish Meteorological Institute. E-sail is based on extracting momentum from the solar wind plasma flow by using long thin electrically charged tethers. ESTCube-1 is equipped with one such tether, together with hardware capable of deploying and charging it. At the orbital altitude of ESTCube-1 (660--680~km) there is no solar wind present. Instead, ESTCube-1 shall observe the interaction between the charged tether and the ionospheric plasma. The ESTCube-1 payload uses a 10-meter, partly two-filament E-sail tether and a motorized reel on which it is stored. The tether shall be deployed from a spinning satellite with the help of centrifugal force. An additional mass is added at the tip of the tether to assist with the deployment. During E-sail experiment the tether shall be charged to 500~V potential. Both positive and negative voltages shall be experimented with. The voltage is provided by a dedicated high voltage source and delivered to the tether through a slip ring contact. When the negative voltage is applied to the tether, the satellite body is expected to attract electron flow capable of compensating for the ion flow, which runs to the tether from the surrounding plasma. With the positive voltage applied, onboard cold cathode electron guns are used to remove excess electrons to maintain the positive voltage of the tether. In this paper we present the design and structure of the tether payload of ESTCube-1.
△ Less
Submitted 28 April, 2014;
originally announced April 2014.
-
Shape coexistence at the proton drip-line: First identification of excited states in 180Pb
Authors:
P. Rahkila,
D. G. Jenkins,
J. Pakarinen,
C. Gray-Jones,
P. T. Greenlees,
U. Jakobsson,
P. Jones,
R. Julin,
S. Juutinen,
S. Ketelhut,
H. Koivisto,
M. Leino,
P. Nieminen,
M. Nyman,
P. Papadakis,
S. Paschalis,
M. Petri,
P. Peura,
O. J. Roberts,
T. Ropponen,
P. Ruotsalainen,
J. Saren,
C. Scholey,
J. Sorri,
A. G. Tuff
, et al. (4 additional authors not shown)
Abstract:
Excited states in the extremely neutron-deficient nucleus, 180Pb, have been identified for the first time using the JUROGAM II array in conjunction with the RITU recoil separator at the Accelerator Laboratory of the University of Jyvaskyla. This study lies at the limit of what is presently achievable with in-beam spectroscopy, with an estimated cross-section of only 10 nb for the 92Mo(90Zr,2n)18…
▽ More
Excited states in the extremely neutron-deficient nucleus, 180Pb, have been identified for the first time using the JUROGAM II array in conjunction with the RITU recoil separator at the Accelerator Laboratory of the University of Jyvaskyla. This study lies at the limit of what is presently achievable with in-beam spectroscopy, with an estimated cross-section of only 10 nb for the 92Mo(90Zr,2n)180Pb reaction. A continuation of the trend observed in 182Pb and 184Pb is seen, where the prolate minimum continues to rise beyond the N=104 mid-shell with respect to the spherical ground state. Beyond mean-field calculations are in reasonable correspondence with the trends deduced from experiment.
△ Less
Submitted 1 March, 2010;
originally announced March 2010.
-
The stellar (n,gamma) cross section of 62Ni
Authors:
H. Nassar,
M. Paul,
I. Ahmad,
D. Berkovits,
M. Bettan,
P. Collon,
S. Dababneh,
S. Ghelberg,
J. P. Greene,
A. Heger,
M. Heil,
D. J. Henderson,
C. L. Jiang,
F. Kaeppeler,
H. Koivisto,
S. O'Brien,
R. C. Pardo,
N. Patronis,
T. Pennington,
R. Plag,
K. E. Rehm,
R. Reifarth,
R. Scott,
S. Sinha,
X. Tang
, et al. (1 additional authors not shown)
Abstract:
The 62Ni(n,gamma)63Ni(t_1/2=100+-2 yrs) reaction plays an important role in the control of the flow path of the slow neutron-capture (s-) nucleosynthesis process. We have measured for the first time the total cross section of this reaction for a quasi-Maxwellian (kT = 25 keV) neutron flux. The measurement was performed by fast-neutron activation, combined with accelerator mass spectrometry to de…
▽ More
The 62Ni(n,gamma)63Ni(t_1/2=100+-2 yrs) reaction plays an important role in the control of the flow path of the slow neutron-capture (s-) nucleosynthesis process. We have measured for the first time the total cross section of this reaction for a quasi-Maxwellian (kT = 25 keV) neutron flux. The measurement was performed by fast-neutron activation, combined with accelerator mass spectrometry to detect directly the 63Ni product nuclei. The experimental value of 28.4+-2.8 mb, fairly consistent with a recent theoretical estimate, affects the calculated net yield of 62Ni itself and the whole distribution of nuclei with 62<A <90 produced by the weak s-process in massive stars.
△ Less
Submitted 12 March, 2005; v1 submitted 5 June, 2004;
originally announced June 2004.