-
Extended X-ray absorption spectroscopy using an ultrashort pulse laboratory-scale laser-plasma accelerator
Authors:
B. Kettle,
C. Colgan,
E. Los,
E. Gerstmayr,
M. J. V. Streeter,
F. Albert,
S. Astbury,
R. A. Baggott,
N. Cavanagh,
K. Falk,
T. I. Hyde,
O. Lundh,
P. P. Rajeev,
D. Riley,
S. J. Rose,
G. Sarri,
C. Spindloe,
K. Svendsen,
D. R. Symes,
M. Smid,
A. G. R. Thomas,
C. Thornton,
R. Watt,
S. P. D. Mangles
Abstract:
Laser-driven compact particle accelerators can provide ultrashort pulses of broadband X-rays, well suited for undertaking X-ray absorption spectroscopy measurements on a femtosecond timescale. Here the Extended X-ray Absorption Fine Structure (EXAFS) features of the K-edge of a copper sample have been observed over a 250 eV window in a single shot using a laser wakefield accelerator, providing inf…
▽ More
Laser-driven compact particle accelerators can provide ultrashort pulses of broadband X-rays, well suited for undertaking X-ray absorption spectroscopy measurements on a femtosecond timescale. Here the Extended X-ray Absorption Fine Structure (EXAFS) features of the K-edge of a copper sample have been observed over a 250 eV window in a single shot using a laser wakefield accelerator, providing information on both the electronic and ionic structure simultaneously. This unique capability will allow the investigation of ultrafast processes, and in particular, probing high-energy-density matter and physics far-from-equilibrium where the sample refresh rate is slow and shot number is limited. For example, states that replicate the tremendous pressures and temperatures of planetary bodies or the conditions inside nuclear fusion reactions. Using high-power lasers to pump these samples also has the advantage of being inherently synchronised to the laser-driven X-ray probe. A perspective on the additional strengths of a laboratory-based ultrafast X-ray absorption source is presented.
△ Less
Submitted 1 July, 2024; v1 submitted 17 May, 2023;
originally announced May 2023.
-
Plasma density profile reconstruction of a gas cell for Ionization Induced Laser Wakefield Acceleration
Authors:
F. Filippi,
L. T. Dickson,
M. Backhouse,
P. Forestier-Colleoni,
C. Gustafsson,
C. Cobo,
C. Ballage,
S. Dobosz Dufrénoy,
E. Löfquist,
G. Maynard,
C. D. Murphy,
Z. Najmudin,
F. Panza,
A. Persson,
M. Scisciò,
O. Vasilovici,
O. Lundh,
B. Cros
Abstract:
Laser-driven plasma wakefields can provide hundreds of MeV electron beam in mm-range distances potentially shrinking the dimension of the actual particle accelerators. The plasma density plays a fundamental role in the control and stability of the acceleration process, which is a key development for the future electron injector proposed by EuPRAXIA. A gas cell was designed by LPGP and LIDYL teams,…
▽ More
Laser-driven plasma wakefields can provide hundreds of MeV electron beam in mm-range distances potentially shrinking the dimension of the actual particle accelerators. The plasma density plays a fundamental role in the control and stability of the acceleration process, which is a key development for the future electron injector proposed by EuPRAXIA. A gas cell was designed by LPGP and LIDYL teams, with variable length and backing pressure, to confine the gas and tailor the gas density profile before the arrival of the laser. This cell was used during an experimental campaign with the multi TW-class laser at the Lund Laser Centre. Ionization assisted injection in a tailored density profile is used to tune the electron beam properties. During the experiment, we filled the gas cell with hydrogen mixed with different concentration of nitrogen. We also varied the backing pressure of the gas and the geometrical length of the gas cell. We used a transverse probe to acquire shadowgraphic images of the plasma and to measure the plasma electron density. Methods and results of the analysis with comparisons between shadowgraphic and interferometric images will be discussed.
△ Less
Submitted 8 May, 2023; v1 submitted 19 April, 2023;
originally announced April 2023.
-
Mechanisms to control laser-plasma coupling in laser wakefield electron acceleration
Authors:
L. T. Dickson,
C. I. D. Underwood,
F. Filippi,
R. J. Shalloo,
J. Björklund Svensson,
D. Guénot,
K. Svendsen,
I. Moulanier,
S. Dobosz Dufrénoy,
C. D. Murphy,
N. C. Lopes,
P. P. Rajeev,
Z. Najmudin,
G. Cantono,
A. Persson,
O. Lundh,
G. Maynard,
M. J. V. Streeter,
B. Cros
Abstract:
Experimental results, supported by precise modelling, demonstrate optimisation of a plasma-based injector with intermediate laser pulse energy ($<1$ J), corresponding to a normalised vector potential $a_0 = 2.15$, using ionisation injection in a tailored plasma density profile. An increase in electron bunch quality and energy is achieved experimentally with the extension of the density downramp at…
▽ More
Experimental results, supported by precise modelling, demonstrate optimisation of a plasma-based injector with intermediate laser pulse energy ($<1$ J), corresponding to a normalised vector potential $a_0 = 2.15$, using ionisation injection in a tailored plasma density profile. An increase in electron bunch quality and energy is achieved experimentally with the extension of the density downramp at the plasma exit. Optimisation of the focal position of the laser pulse in the tailored plasma density profile is shown to efficiently reduce electron bunch angular deviation, leading to a better alignment of the electron bunch with the laser axis. Single peak electron spectra are produced in a previously unexplored regime by combining an early focal position and adaptive optic control of the laser wavefront through optimising the symmetry of the pre-focal laser energy distribution. Experimental results have been validated through particle-in-cell simulations using realistic laser energy, phase distribution, and temporal envelope, allowing for accurate predictions of difficult to model parameters, such as total charge and spatial properties of the electron bunches, opening the way for more accurate modelling for the design of plasma-based accelerators.
△ Less
Submitted 18 August, 2022; v1 submitted 17 August, 2022;
originally announced August 2022.
-
European Strategy for Particle Physics -- Accelerator R&D Roadmap
Authors:
C. Adolphsen,
D. Angal-Kalinin,
T. Arndt,
M. Arnold,
R. Assmann,
B. Auchmann,
K. Aulenbacher,
A. Ballarino,
B. Baudouy,
P. Baudrenghien,
M. Benedikt,
S. Bentvelsen,
A. Blondel,
A. Bogacz,
F. Bossi,
L. Bottura,
S. Bousson,
O. Brüning,
R. Brinkmann,
M. Bruker,
O. Brunner,
P. N. Burrows,
G. Burt,
S. Calatroni,
K. Cassou
, et al. (111 additional authors not shown)
Abstract:
The 2020 update of the European Strategy for Particle Physics emphasised the importance of an intensified and well-coordinated programme of accelerator R&D, supporting the design and delivery of future particle accelerators in a timely, affordable and sustainable way. This report sets out a roadmap for European accelerator R&D for the next five to ten years, covering five topical areas identified…
▽ More
The 2020 update of the European Strategy for Particle Physics emphasised the importance of an intensified and well-coordinated programme of accelerator R&D, supporting the design and delivery of future particle accelerators in a timely, affordable and sustainable way. This report sets out a roadmap for European accelerator R&D for the next five to ten years, covering five topical areas identified in the Strategy update. The R&D objectives include: improvement of the performance and cost-performance of magnet and radio-frequency acceleration systems; investigations of the potential of laser / plasma acceleration and energy-recovery linac techniques; and development of new concepts for muon beams and muon colliders. The goal of the roadmap is to document the collective view of the field on the next steps for the R&D programme, and to provide the evidence base to support subsequent decisions on prioritisation, resourcing and implementation.
△ Less
Submitted 30 March, 2022; v1 submitted 19 January, 2022;
originally announced January 2022.
-
Characterisation of Laser Wakefield Acceleration Efficiency with Octave Spanning Near-IR Spectrum Measurements
Authors:
M. J. V. Streeter,
Y. Ma,
B. Kettle,
S. J. D. Dann,
E. Gerstmayr,
F. Albert,
N. Bourgeois,
S. Cipiccia,
J. M. Cole,
I. Gallardo González,
A. E. Hussein,
D. A. Jaroszynski,
K. Falk,
K. Krushelnick,
N. Lemos,
N. C. Lopes,
C. Lumsdon,
O. Lundh,
S. P. D. Mangles,
Z. Najmudin,
P. P. Rajeev,
R. Sandberg,
M. Shahzad,
M. Smid,
R. Spesyvtsev
, et al. (3 additional authors not shown)
Abstract:
We report on experimental measurements of energy transfer efficiencies in a GeV-class laser wakefield accelerator. Both the transfer of energy from the laser to the plasma wakefield, and from the plasma to the accelerated electron beam were diagnosed by simultaneous measurement of the deceleration of laser photons and the acceleration of electrons as a function of plasma length. The extraction eff…
▽ More
We report on experimental measurements of energy transfer efficiencies in a GeV-class laser wakefield accelerator. Both the transfer of energy from the laser to the plasma wakefield, and from the plasma to the accelerated electron beam were diagnosed by simultaneous measurement of the deceleration of laser photons and the acceleration of electrons as a function of plasma length. The extraction efficiency, which we define as the ratio of the energy gained by the electron beam to the energy lost by the self-guided laser mode, was maximised at $19\pm3$\% by tuning of the plasma density and length. The additional information provided by the octave-spanning laser spectrum measurement allows for independent optimisation of the plasma efficiency terms, which is required for the key goal of improving the overall efficiency of laser wakefield accelerators.
△ Less
Submitted 20 December, 2022; v1 submitted 2 November, 2020;
originally announced November 2020.
-
Interaction of ultraintense radially-polarized laser pulses with plasma mirrors
Authors:
N. Zaïm,
D. Guénot,
L. Chopineau,
A. Denoeud,
O. Lundh,
H. Vincenti,
F. Quéré,
J. Faure
Abstract:
We present experimental results of vacuum laser acceleration (VLA) of electrons using radially polarized laser pulses interacting with a plasma mirror. Tightly focused radially polarized laser pulses have been proposed for electron acceleration because of their strong longitudinal electric field, making them ideal for VLA. However, experimental results have been limited until now because injecting…
▽ More
We present experimental results of vacuum laser acceleration (VLA) of electrons using radially polarized laser pulses interacting with a plasma mirror. Tightly focused radially polarized laser pulses have been proposed for electron acceleration because of their strong longitudinal electric field, making them ideal for VLA. However, experimental results have been limited until now because injecting electrons into the laser field has remained a considerable challenge. Here, we demonstrate experimentally that using a plasma mirror as an injector solves this problem and permits to inject electrons at the ideal phase of the laser, resulting in the acceleration of electrons along the laser propagation direction while reducing the electron beam divergence compared to the linear polarization case. We obtain electron bunches with few-MeV energies and a 200 pC charge, thus demonstrating for the first time electron acceleration to relativistic energies using a radially polarized laser. High-harmonic generation from the plasma surface is also measured and provides additional insight into the injection of electrons into the laser field upon its reflection on the plasma mirror. Detailed comparisons between experimental results and full 3D simulations unravel the complex physics of electron injection and acceleration in this new regime: we find that electrons are injected into the radially polarized pulse in the form of two spatially-separated bunches emitted from the p-polarized regions of the focus. Finally, we leverage on the insight brought by this study to propose and validate a more optimal experimental configuration that can lead to extremely peaked electron angular distributions and higher energy beams.
△ Less
Submitted 7 April, 2020;
originally announced April 2020.
-
Simultaneous laser-driven X-ray and two-photon fluorescence imaging of atomizing sprays
Authors:
Diego Guenot,
Kristoffer Svendsen,
Jonas Björklund Svensson,
Henrik Ekerfelt,
Anders Persson,
Olle Lundh,
Edouard Berrocal
Abstract:
In this letter we report for the first time the possibility of visualizing an atomizing spray by simultaneously recording X-ray absorption and 2- photon laser-induced fluorescence imaging. This unique illumination/detection scheme was made possible thanks to the use of soft X-rays emitted from a laser-driven X-ray source. An 800 mJ laser pulse of 38 fs duration is used to generate an X-ray beam wi…
▽ More
In this letter we report for the first time the possibility of visualizing an atomizing spray by simultaneously recording X-ray absorption and 2- photon laser-induced fluorescence imaging. This unique illumination/detection scheme was made possible thanks to the use of soft X-rays emitted from a laser-driven X-ray source. An 800 mJ laser pulse of 38 fs duration is used to generate an X-ray beam with up to 4.10^8 photons ranging from 1 to 10 keV; allowing projection radiography of water jets generated by an automotive port fuel injector. In addition, a fraction of the laser pulse (approximately 10 mJ)is employed to form a light sheet and to induce 2-photon fluorescence from a dye added to the water. The resulting high-contrast fluorescence images provide fine details of the spray structure, with reduced blur from multiple light scattering, while the integrated liquid mass is extracted from the X-ray radiography. The combination of these two highly complementary techniques, both in the visible and in the soft X-ray regime, is very promising for the future characterization of challenging spray systems as well as for further understanding the physics of liquid atomization.
△ Less
Submitted 28 December, 2019;
originally announced December 2019.
-
Single-shot multi-keV X-ray absorption spectroscopy using an ultrashort laser wakefield accelerator source
Authors:
B. Kettle,
E. Gerstmayr,
M. J. V. Streeter,
F. Albert,
R. A. Baggott,
N. Bourgeois,
J. M. Cole,
S. Dann,
K. Falk,
I. Gallardo González,
A. E. Hussein,
N. Lemos,
N. C. Lopes,
O. Lundh,
Y. Ma,
S. J. Rose,
C. Spindloe,
D. R. Symes,
M. Šmíd,
A. G. R. Thomas,
R. Watt,
S. P. D. Mangles
Abstract:
Single-shot absorption measurements have been performed using the multi-keV X-rays generated by a laser wakefield accelerator. A 200 TW laser was used to drive a laser wakefield accelerator in a mode which produced broadband electron beams with a maximum energy above 1 GeV and a broad divergence of $\approx15$ miliradians FWHM. Betatron oscillations of these electrons generated…
▽ More
Single-shot absorption measurements have been performed using the multi-keV X-rays generated by a laser wakefield accelerator. A 200 TW laser was used to drive a laser wakefield accelerator in a mode which produced broadband electron beams with a maximum energy above 1 GeV and a broad divergence of $\approx15$ miliradians FWHM. Betatron oscillations of these electrons generated $1.2\pm0.2\times10^6$ photons/eV in the 5 keV region, with a signal-to-noise ratio of approximately 300:1. This was sufficient to allow high-resolution XANES measurements at the K-edge of a titanium sample in a single shot. We demonstrate that this source is capable of single-shot, simultaneous measurements of both the electron and ion distributions in matter heated to eV temperatures by comparison with DFT simulations. The unique combination of a high-flux, large bandwidth, few femtosecond duration X-ray pulse synchronised to a high-power laser will enable key advances in the study of ultra-fast energetic processes such as electron-ion equilibration.
△ Less
Submitted 5 December, 2019; v1 submitted 23 July, 2019;
originally announced July 2019.
-
Proton acceleration by a pair of successive ultraintense femtosecond laser pulses
Authors:
Julien Ferri,
Lovisa Senje,
Malay Dalui,
Kristoffer Svensson,
Bastian Aurand,
Martin Hansson,
Anders Persson,
Olle Lundh,
Claes-Göran Wahlström,
Laurent Gremillet,
Evangelos Siminos,
Timothy DuBois,
Longqing Yi,
Joana Martins,
Tünde Fülöp
Abstract:
We investigate the target normal sheath acceleration of protons in thin aluminum targets irradiated at relativistic intensity by two time-separated ultrashort (35 fs) laser pulses. For identical laser pulses and target thicknesses of 3 and 6 $μ$m, we observe experimentally that the second pulse boosts the maximum energy and charge of the proton beam produced by the first pulse for time delays belo…
▽ More
We investigate the target normal sheath acceleration of protons in thin aluminum targets irradiated at relativistic intensity by two time-separated ultrashort (35 fs) laser pulses. For identical laser pulses and target thicknesses of 3 and 6 $μ$m, we observe experimentally that the second pulse boosts the maximum energy and charge of the proton beam produced by the first pulse for time delays below $\sim0.6-1$ ps. By using two-dimensional particle-in-cell simulations we examine the variation of the proton energy spectra with respect to the time-delay between the two pulses. We demonstrate that the expansion of the target front surface caused by the first pulse significantly enhances the hot-electron generation by the second pulse arriving after a few hundreds of fs time delay. This enhancement, however, does not suffice to further accelerate the fastest protons driven by the first pulse once three-dimensional quenching effects have set in. This implies a limit to the maximum time delay that leads to proton energy enhancement, which we theoretically determine.
△ Less
Submitted 20 February, 2018;
originally announced February 2018.
-
Highly efficient angularly resolving x-ray spectrometer optimized for absorption measurements with collimated sources
Authors:
Michal Šmíd,
Isabel Gallardo-Gonzáles,
Henrik Ekerfelt,
Jonas Björklund Svensson,
Martin Hansson,
Jonathan C. Wood,
Anders Persson,
Stuart P. D. Mangles,
Olle Lundh,
Kateřina Falk
Abstract:
Highly collimated betatron radiation from a laser wakefield accelerator is a promising tool for spectroscopic measurements. Therefore there is a requirement to create spectrometers suited to the unique properties of such a source. We demonstrate a spectrometer which achieves an energy resolution of < 5 eV at 9 keV and is angularly resolving the x-ray emission allowing the reference and spectrum to…
▽ More
Highly collimated betatron radiation from a laser wakefield accelerator is a promising tool for spectroscopic measurements. Therefore there is a requirement to create spectrometers suited to the unique properties of such a source. We demonstrate a spectrometer which achieves an energy resolution of < 5 eV at 9 keV and is angularly resolving the x-ray emission allowing the reference and spectrum to be recorded at the same time. The single photon analysis is used to significantly reduce the background noise. Theoretical performance of various configurations of the spectrometer is calculated by a ray-tracing algorithm. The properties and performance of the spectrometer including the angular and spectral resolution are demonstrated experimentally on absorption above the K-edge of a Cu foil backlit by laser-produced betatron radiation x-ray beam.
△ Less
Submitted 20 June, 2017;
originally announced June 2017.
-
Propagation of Ultra-Intense Laser Pulses in Near-critical Plasmas: Depletion Mechanisms and Effects of Radiation Reaction
Authors:
Erik Wallin,
Arkady Gonoskov,
Christopher Harvey,
Olle Lundh,
Mattias Marklund
Abstract:
Although, for current laser pulse energies, the weakly nonlinear regime of LWFA is known to be the optimal for reaching the highest possible electron energies, the capabilities of upcoming large laser systems will provide the possibility of running highly nonlinear regimes of laser pulse propagation in underdense or near-critical plasmas. Using an extended particle-in-cell (PIC) model that takes i…
▽ More
Although, for current laser pulse energies, the weakly nonlinear regime of LWFA is known to be the optimal for reaching the highest possible electron energies, the capabilities of upcoming large laser systems will provide the possibility of running highly nonlinear regimes of laser pulse propagation in underdense or near-critical plasmas. Using an extended particle-in-cell (PIC) model that takes into account all the relevant physics, we show that such regimes can be implemented with external guiding for a relatively long distance of propagation and allow for the stable transformation of laser energy into other types of energy, including the kinetic energy of a large number of high energy electrons and their incoherent emission of photons. This is despite the fact that the high intensity of the laser pulse triggers a number of new mechanisms of energy depletion, which we investigate systematically.
△ Less
Submitted 5 April, 2017; v1 submitted 10 December, 2015;
originally announced December 2015.
-
Betatron emission as a diagnostic for injection and acceleration mechanisms in laser-plasma accelerators
Authors:
S. Corde,
C. Thaury,
K. Ta Phuoc,
A. Lifschitz,
G. Lambert,
O. Lundh,
P. Brijesh,
L. Arantchuk,
S. Sebban,
A. Rousse,
J. Faure,
V. Malka
Abstract:
Betatron x-ray emission in laser-plasma accelerators is a promising compact source that may be an alternative to conventional x-ray sources, based on large scale machines. In addition to its potential as a source, precise measurements of betatron emission can reveal crucial information about relativistic laser-plasma interaction. We show that the emission length and the position of the x-ray emiss…
▽ More
Betatron x-ray emission in laser-plasma accelerators is a promising compact source that may be an alternative to conventional x-ray sources, based on large scale machines. In addition to its potential as a source, precise measurements of betatron emission can reveal crucial information about relativistic laser-plasma interaction. We show that the emission length and the position of the x-ray emission can be obtained by placing an aperture mask close to the source, and by measuring the beam profile of the betatron x-ray radiation far from the aperture mask. The position of the x-ray emission gives information on plasma wave breaking and hence on the laser non-linear propagation. Moreover, the measurement of the longitudinal extension helps one to determine whether the acceleration is limited by pump depletion or dephasing effects. In the case of multiple injections, it is used to retrieve unambiguously the position in the plasma of each injection. This technique is also used to study how, in a capillary discharge, the variations of the delay between the discharge and the laser pulse affect the interaction. The study reveals that, for a delay appropriate for laser guiding, the x-ray emission only occurs in the second half of the capillary: no electrons are injected and accelerated in the first half.
△ Less
Submitted 22 November, 2012;
originally announced November 2012.
-
Laser Wakefield Acceleration Using Wire Produced Double Density Ramps
Authors:
M. Burza,
A. Gonoskov,
K. Svensson,
F. Wojda,
A. Persson,
M. Hansson,
G. Genoud,
M. Marklund,
C. -G. Wahlström,
O. Lundh
Abstract:
A novel approach to implement and control electron injection into the accelerating phase of a laser wakefield accelerator (LWFA) is presented. It utilizes a wire, which is introduced into the flow of a supersonic gas jet creating shock waves and three regions of differing plasma electron density. If tailored appropriately, the laser plasma interaction takes place in three stages: Laser self-compre…
▽ More
A novel approach to implement and control electron injection into the accelerating phase of a laser wakefield accelerator (LWFA) is presented. It utilizes a wire, which is introduced into the flow of a supersonic gas jet creating shock waves and three regions of differing plasma electron density. If tailored appropriately, the laser plasma interaction takes place in three stages: Laser self-compression, electron injection and acceleration in the second plasma wave period. Compared to self-injection by wavebreaking of a nonlinear plasma wave in a constant density plasma, this scheme increases beam charge by up to one order of magnitude in the quasi-monoenergetic regime. Electron acceleration in the second plasma wave period reduces electron beam divergence by approximately 25 %, and the localized injection at the density downramps results in spectra with less than a few percent relative spread.
△ Less
Submitted 25 October, 2012;
originally announced October 2012.
-
Mapping the X-Ray Emission Region in a Laser-Plasma Accelerator
Authors:
S. Corde,
C. Thaury,
K. Ta Phuoc,
A. Lifschitz,
G. Lambert,
J. Faure,
O. Lundh,
E. Benveniste,
A. Ben-Ismail,
L. Arantchuk,
A. Marciniak,
A. Stordeur,
P. Brijesh,
A. Rousse,
A. Specka,
V. Malka
Abstract:
The x-ray emission in laser-plasma accelerators can be a powerful tool to understand the physics of relativistic laser-plasma interaction. It is shown here that the mapping of betatron x-ray radiation can be obtained from the x-ray beam profile when an aperture mask is positioned just beyond the end of the emission region. The influence of the plasma density on the position and the longitudinal pr…
▽ More
The x-ray emission in laser-plasma accelerators can be a powerful tool to understand the physics of relativistic laser-plasma interaction. It is shown here that the mapping of betatron x-ray radiation can be obtained from the x-ray beam profile when an aperture mask is positioned just beyond the end of the emission region. The influence of the plasma density on the position and the longitudinal profile of the x-ray emission is investigated and compared to particle-in-cell simulations. The measurement of the x-ray emission position and length provides insight on the dynamics of the interaction, including the electron self-injection region, possible multiple injection, and the role of the electron beam driven wakefield.
△ Less
Submitted 18 November, 2011; v1 submitted 13 April, 2011;
originally announced April 2011.
-
Observation of Plasma-Undulator Harmonics from a Laser Wakefield Accelerator
Authors:
G. Genoud,
K. Cassou,
F. Wojda,
M. Burza,
C. Kamperidis,
A. Persson,
J. Uhlig,
O. Lundh,
S. Kneip,
S. P. D. Mangles,
H. Ferrari,
A. Lifschitz,
B. Cros,
C. -G. Wahlström
Abstract:
This paper has been withdrawn by the author. An assumption made in the analysis is not valid under the experimental conditions.
This paper has been withdrawn by the author. An assumption made in the analysis is not valid under the experimental conditions.
△ Less
Submitted 9 March, 2010; v1 submitted 4 December, 2009;
originally announced December 2009.
-
Laser-driven plasma waves in capillary tubes
Authors:
F. Wojda,
K. Cassou,
G. Genoud,
M. Burza,
Y. Glinec,
O. Lundh,
A. Persson,
G. Vieux,
E. Brunetti,
R. P. Shanks,
D. Jaroszynski,
N. E. Andreev,
C. -G. Wahlstrom,
B. Cros
Abstract:
The excitation of plasma waves over a length of up to 8 centimeters is, for the first time, demon- strated using laser guiding of intense laser pulses through hydrogen filled glass capillary tubes. The plasma waves are diagnosed by spectral analysis of the transmitted laser radiation. The dependence of the spectral redshift, measured as a function of filling pressure, capillary tube length and i…
▽ More
The excitation of plasma waves over a length of up to 8 centimeters is, for the first time, demon- strated using laser guiding of intense laser pulses through hydrogen filled glass capillary tubes. The plasma waves are diagnosed by spectral analysis of the transmitted laser radiation. The dependence of the spectral redshift, measured as a function of filling pressure, capillary tube length and incident laser energy, is in excellent agreement with simulation results. The longitudinal accelerating field inferred from the simulations is in the range 1 -10 GV/m.
△ Less
Submitted 16 October, 2009;
originally announced October 2009.