-
Isotope substitution and polytype control for point defects identification: the case of the ultraviolet color center in hexagonal boron nitride
Authors:
J. Plo,
A. Pershin,
S. Li,
T. Poirier,
E. Janzen,
H. Schutte,
M. Tian,
M. Wynn,
S. Bernard,
A. Rousseau,
A. Ibanez,
P. Valvin,
W. Desrat,
T. Michel,
V. Jacques,
B. Gil,
A. Kaminska,
N. Wan,
J. H. Edgar,
A. Gali,
G. Cassabois
Abstract:
Defects in crystals can have a transformative effect on the properties and functionalities of solid-state systems. Dopants in semiconductors are core components in electronic and optoelectronic devices. The control of single color centers is at the basis of advanced applications for quantum technologies. Unintentional defects can also be detrimental to the crystalline structure and hinder the deve…
▽ More
Defects in crystals can have a transformative effect on the properties and functionalities of solid-state systems. Dopants in semiconductors are core components in electronic and optoelectronic devices. The control of single color centers is at the basis of advanced applications for quantum technologies. Unintentional defects can also be detrimental to the crystalline structure and hinder the development of novel materials. Whatever the research perspective, the identification of defects is a key but complicated, and often long-standing issue. Here, we present a general methodology to identify point defects by combining isotope substitution and polytype control, with a systematic comparison between experiments and first-principles calculations. We apply this methodology to hexagonal boron nitride (hBN) and its ubiquitous color center emitting in the ultraviolet spectral range. From isotopic purification of the host hBN matrix, a local vibrational mode of the defect is uncovered, and isotope-selective carbon doping proves that this mode belongs to a carbon-based center. Then, by varying the stacking sequence of the host hBN matrix, we unveil different optical responses to hydrostatic pressure for the non-equivalent configurations of this ultraviolet color center. We conclude that this defect is a carbon dimer in the honeycomb lattice of hBN. Our results show that tuning the stacking sequence in different polytypes of a given crystal provides unique fingerprints contributing to the identification of defects in 2D materials.
△ Less
Submitted 31 May, 2024;
originally announced May 2024.
-
Boron and nitrogen isotope effects on hexagonal boron nitride properties
Authors:
E. Janzen,
H. Schutte,
J. Plo,
A. Rousseau,
T. Michel,
W. Desrat,
P. Valvin,
V. Jacques,
G. Cassabois,
B. Gil,
J. H. Edgar
Abstract:
The unique physical, mechanical, chemical, optical, and electronic properties of hexagonal boron nitride (hBN) make it a promising two-dimensional material for electronic, optoelectronic, nanophotonic, and quantum devices. Here we report on the changes in hBN's properties induced by isotopic purification in both boron and nitrogen. Previous studies on isotopically pure hBN have focused on purifyin…
▽ More
The unique physical, mechanical, chemical, optical, and electronic properties of hexagonal boron nitride (hBN) make it a promising two-dimensional material for electronic, optoelectronic, nanophotonic, and quantum devices. Here we report on the changes in hBN's properties induced by isotopic purification in both boron and nitrogen. Previous studies on isotopically pure hBN have focused on purifying the boron isotope concentration in hBN from its natural concentration (approximately 20 at$\%$ $^{10}$B, 80 at$\%$ $^{11}$B) while using naturally abundant nitrogen (99.6 at$\%$ $^{14}$N, 0.4 at$\%$ $^{15}$N), i.e. almost pure $^{14}$N. In this study, we extend the class of isotopically-purified hBN crystals to $^{15}$N. Crystals in the four configurations, namely h$^{10}$B$^{14}$N, h$^{11}$B$^{14}$N, h$^{10}$B$^{15}$N, and h$^{11}$B$^{15}$N, were grown by the metal flux method using boron and nitrogen single isotope ($>99\%$) enriched sources, with nickel plus chromium as the solvent. In-depth Raman and photoluminescence spectroscopies demonstrate the high quality of the monoisotopic hBN crystals with vibrational and optical properties of the $^{15}$N-purified crystals at the state of the art of currently available $^{14}$N-purified hBN. The growth of high-quality h$^{10}$B$^{14}$N, h$^{11}$B$^{14}$N, h$^{10}$B$^{15}$N, and h$^{11}$B$^{15}$N opens exciting perspectives for thermal conductivity control in heat management, as well as for advanced functionalities in quantum technologies.
△ Less
Submitted 23 June, 2023;
originally announced June 2023.
-
Optical intensity interferometry lab tests in preparation of stellar diameter measurements at IACTs at GHz photon rates
Authors:
Andreas Zmija,
Naomi Vogel,
Gisela Anton,
Dmitry Malyshev,
Thilo Michel,
Adrian Zink,
Stefan Funk
Abstract:
Astronomical intensity interferometry enables quantitative measurements of the source geometry by measuring the photon fluxes in individual telescopes and correlating them, rather than correlating the electromagnetic waves' amplitudes. This simplifies realization of large telescope baselines and high angular resolutions. Imaging Atmospheric Cherenkov Telescopes (IACTs), intended to detect the opti…
▽ More
Astronomical intensity interferometry enables quantitative measurements of the source geometry by measuring the photon fluxes in individual telescopes and correlating them, rather than correlating the electromagnetic waves' amplitudes. This simplifies realization of large telescope baselines and high angular resolutions. Imaging Atmospheric Cherenkov Telescopes (IACTs), intended to detect the optical emission of $γ$-ray induced air showers, are excellent candidates to perform intensity correlations in the optical at reasonable signal-to-noise ratios. The detected coherence time is on the scale of $10^{-12}$ to $10^{-15}$~seconds - depending on the optical bandwidth of the measurement - which challenges the detection system to work in a stable and accurate way. We developed an intensity interferometry setup applicable to IACTs, which measures the photo currents from photomultipliers and correlates them offline, and as such is designed to handle the very large photon rates provided by the telescopes. We present measurements in the lab simulating starlight using a xenon lamp and measured at different degrees of temporal and spatial coherence. Necessary calibration procedures are described with the goal of understanding the measurements quantitatively. Measured coherence times between $5\,$femtoseconds (corresponding signal-to-background ratio $5\cdot10^{-7}$) and $110\,$femtoseconds (signal-to-background ratio $10^{-5}$) are in good agreement with expectations, and so are the noise levels in the correlations, reaching down to $6 \cdot 10^{-8}$, after measurements between $30\,$minutes and $1\,$ hour.
△ Less
Submitted 13 June, 2023;
originally announced June 2023.
-
Active Personal Eye Lens Dosimetry with the Hybrid Pixelated Dosepix Detector
Authors:
Florian Beißer,
Dennis Haag,
Rafael Ballabriga,
Rolf Behrens,
Michael Campbell,
Christian Fuhg,
Patrick Hufschmidt,
Oliver Hupe,
Carolin Kupillas,
Xavier Llopart,
Jürgen Roth,
Sebastian Schmidt,
Markus Schneider,
Lukas Tlustos,
Winnie Wong,
Hayo Zutz,
Thilo Michel,
Erlangen Centre for Astroparticle Physics,
CERN,
Physikalisch-Technische Bundesantalt,
was with the Erlangen Centre for Astroparticle Physics,
is now with Helene-Lange-Gymnasium,
was with the Erlangen Centre for Astroparticle Physics,
is now with CodeCamp,
:
, et al. (6 additional authors not shown)
Abstract:
Eye lens dosimetry has been an important field of research in the last decade. Dose measurements with a prototype of an active personal eye lens dosemeter based on the Dosepix detector are presented. The personal dose equivalent at $3\,$mm depth of soft tissue, $H_\text{p}(3)$, was measured in the center front of a water-filled cylinder phantom with a height and diameter of $20\,$cm. The energy de…
▽ More
Eye lens dosimetry has been an important field of research in the last decade. Dose measurements with a prototype of an active personal eye lens dosemeter based on the Dosepix detector are presented. The personal dose equivalent at $3\,$mm depth of soft tissue, $H_\text{p}(3)$, was measured in the center front of a water-filled cylinder phantom with a height and diameter of $20\,$cm. The energy dependence of the normalized response is investigated for mean photon energies between $12.4\,$keV and $248\,$keV for continuous reference radiation fields (N-series) according to ISO 4037. The response normalized to N-60 ($\overline{E}=47.9\,\text{keV}$) at $0^\circ$ angle of irradiation stays within the approval limits of IEC 61526 for angles of incidence between $-75^\circ$ and $+75^\circ$. Performance in pulsed photon fields was tested for varying dose rates from $0.1\,\frac{\text{Sv}}{\text{h}}$ up to $1000\,\frac{\text{Sv}}{\text{h}}$ and pulse durations from $1\,\text{ms}$ up to $10\,\text{s}$. The dose measurement works well within the approval limits (acc. to IEC 61526) up to $1\,\frac{\text{Sv}}{\text{h}}$. No significant influence of the pulse duration on the measured dose is found. Reproducibility measurements yield a coefficient of variation which does not exceed $1\,\%$ for two tested eye lens dosemeter prototypes.
△ Less
Submitted 1 August, 2023; v1 submitted 9 May, 2023;
originally announced May 2023.
-
Generative Adversarial Networks for Scintillation Signal Simulation in EXO-200
Authors:
S. Li,
I. Ostrovskiy,
Z. Li,
L. Yang,
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian
, et al. (65 additional authors not shown)
Abstract:
Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial N…
▽ More
Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial Network - a deep learning technique allowing for implicit non-parametric estimation of the population distribution for a given set of objects. Our network is trained on real calibration data using raw scintillation waveforms as input. We find that it is able to produce high-quality simulated waveforms an order of magnitude faster than the traditional simulation approach and, importantly, generalize from the training sample and discern salient high-level features of the data. In particular, the network correctly deduces position dependency of scintillation light response in the detector and correctly recognizes dead photodetector channels. The network output is then integrated into the EXO-200 analysis framework to show that the standard EXO-200 reconstruction routine processes the simulated waveforms to produce energy distributions comparable to that of real waveforms. Finally, the remaining discrepancies and potential ways to improve the approach further are highlighted.
△ Less
Submitted 8 May, 2023; v1 submitted 11 March, 2023;
originally announced March 2023.
-
Search for Two-neutrino Double-Beta Decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ with the Complete EXO-200 Dataset
Authors:
EXO-200 Collaboration,
:,
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling
, et al. (83 additional authors not shown)
Abstract:
A new search for two-neutrino double-beta ($2νββ$) decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the additio…
▽ More
A new search for two-neutrino double-beta ($2νββ$) decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the addition of the Phase II dataset taken with an upgraded detector, the median 90$\%$ confidence level half-life sensitivity of $2νββ$ decay to the $0^+_1$ state of $^{136}\rm Ba$ is $2.9 \times 10^{24}~\rm yr$ using a total $^{136}\rm Xe$ exposure of $234.1~\rm kg~yr$. No statistically significant evidence for $2νββ$ decay to the $0^+_1$ state is observed, leading to a lower limit of $T^{2ν}_{1/2}(0^+ \rightarrow 0^+_1) > 1.4\times10^{24}~\rm yr$ at 90$\%$ confidence level, improved by 70$\%$ relative to the current world's best constraint.
△ Less
Submitted 16 October, 2023; v1 submitted 2 March, 2023;
originally announced March 2023.
-
Search for MeV Electron Recoils from Dark Matter in EXO-200
Authors:
EXO-200 Collaboration,
:,
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling
, et al. (83 additional authors not shown)
Abstract:
We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron recoil background rate of $6.8 \times 10^{-4}\, \mathrm{cts}\,\mathrm{kg}^{-1}\mathrm{yr}^{-1}\mathrm{keV}^{-1}$ above $4\,\mathrm{MeV}$ and find no statistically significant excess over our background projection. Using a total…
▽ More
We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron recoil background rate of $6.8 \times 10^{-4}\, \mathrm{cts}\,\mathrm{kg}^{-1}\mathrm{yr}^{-1}\mathrm{keV}^{-1}$ above $4\,\mathrm{MeV}$ and find no statistically significant excess over our background projection. Using a total ${}^{136}\mathrm{Xe}$ exposure of $234.1\,\mathrm{kg}\,\mathrm{yr}$ we exclude new parameter space for the charged-current absorption cross-section for dark matter masses between $m_χ= 2.6\,\mathrm{MeV} - 11.6\,\mathrm{MeV}$ with a minimum of $6\times 10^{-51}\,\mathrm{cm}^2$ at $8.3\,\mathrm{MeV}$ at the $90\%$ confidence level.
△ Less
Submitted 20 February, 2023; v1 submitted 2 July, 2022;
originally announced July 2022.
-
Comparing Different Approaches for Stellar Intensity Interferometry
Authors:
Sebastian Karl,
Andreas Zmija,
Stefan Richter,
Naomi Vogel,
Dmitry Malyshev,
Adrian Zink,
Thilo Michel,
Gisela Anton,
Joachim von Zanthier,
Stefan Funk
Abstract:
Stellar intensity interferometers correlate photons within their coherence time and could overcome the baseline limitations of existing amplitude interferometers. Intensity interferometers do not rely on phase coherence of the optical elements and thus function without high grade optics and light combining delay lines. However, the coherence time of starlight observed with realistic optical filter…
▽ More
Stellar intensity interferometers correlate photons within their coherence time and could overcome the baseline limitations of existing amplitude interferometers. Intensity interferometers do not rely on phase coherence of the optical elements and thus function without high grade optics and light combining delay lines. However, the coherence time of starlight observed with realistic optical filter bandwidths (> 0.1 nm) is usually much smaller than the time resolution of the detection system (> 10 ps), resulting in a greatly reduced correlation signal. Reaching high signal to noise in a reasonably short measurement time can be achieved in different ways: either by increasing the time resolution, which increases the correlation signal height, or by increasing the photon rate, which decreases statistical uncertainties of the measurement. We present laboratory measurements employing both approaches and directly compare them in terms of signal to noise ratio. A high time-resolution interferometry setup designed for small to intermediate size optical telescopes and thus lower photon rates (diameters < some meters) is compared to a setup capable of measuring high photon rates, which is planned to be installed at Cherenkov telescopes with dish diameters of > 10 m. We use a Xenon lamp as a common light source simulating starlight. Both setups measure the expected correlation signal and work at the expected shot-noise limit of statistical uncertainties for measurement times between 10 min and 23 h. We discuss the quantitative differences in the measurement results and give an overview of suitable operation regimes for each of the interferometer concepts.
△ Less
Submitted 25 January, 2022;
originally announced January 2022.
-
Decoherence of V$_{\rm B}^{-}$ spin defects in monoisotopic hexagonal boron nitride
Authors:
A. Haykal,
R. Tanos,
N. Minotto,
A. Durand,
F. Fabre,
J. Li,
J. H. Edgar,
V. Ivady,
A. Gali,
T. Michel,
A. Dréau,
B. Gil,
G. Cassabois,
V. Jacques
Abstract:
Spin defects in hexagonal boron nitride (hBN) are promising quantum systems for the design of flexible two-dimensional quantum sensing platforms. Here we rely on hBN crystals isotopically enriched with either $^{10}$B or $^{11}$B to investigate the isotope-dependent properties of a spin defect featuring a broadband photoluminescence signal in the near infrared. By analyzing the hyperfine structure…
▽ More
Spin defects in hexagonal boron nitride (hBN) are promising quantum systems for the design of flexible two-dimensional quantum sensing platforms. Here we rely on hBN crystals isotopically enriched with either $^{10}$B or $^{11}$B to investigate the isotope-dependent properties of a spin defect featuring a broadband photoluminescence signal in the near infrared. By analyzing the hyperfine structure of the spin defect while changing the boron isotope, we first unambiguously confirm that it corresponds to the negatively-charged boron-vacancy center (${\rm V}_{\rm B}^-$). We then show that its spin coherence properties are slightly improved in $^{10}$B-enriched samples. This is supported by numerical simulations employing cluster correlation expansion methods, which reveal the importance of the hyperfine Fermi contact term for calculating the coherence time of point defects in hBN. Using cross-relaxation spectroscopy, we finally identify dark electron spin impurities as an additional source of decoherence. This work provides new insights into the properties of ${\rm V}_{\rm B}^-$ spin defects, which are valuable for the future development of hBN-based quantum sensing foils.
△ Less
Submitted 19 December, 2021;
originally announced December 2021.
-
Dynamic instability of individual carbon nanotube growth revealed by in situ homodyne polarization microscopy
Authors:
Vladimir Pimonov,
Huy-Nam Tran,
Léonard Monniello,
Saïd Tahir,
Thierry Michel,
Renaud Podor,
Michaël Odorico,
Christophe Bichara,
Vincent Jourdain
Abstract:
Understanding the kinetic selectivity of carbon nanotube growth at the scale of individual nanotubes is essential for the development of high chiral selectivity growth methods. Here we demonstrate that homodyne polarization microscopy can be used for high-throughput imaging of long individual carbon nanotubes under real growth conditions (at ambient pressure, on a substrate), and with sub-second t…
▽ More
Understanding the kinetic selectivity of carbon nanotube growth at the scale of individual nanotubes is essential for the development of high chiral selectivity growth methods. Here we demonstrate that homodyne polarization microscopy can be used for high-throughput imaging of long individual carbon nanotubes under real growth conditions (at ambient pressure, on a substrate), and with sub-second time resolution. Our in situ observations on hundreds of individual nanotubes reveal that about half of them grow at a constant rate all along their lifetime while the other half exhibits stochastic changes in growth rates, and switches between growth, pause and shrinkage. Statistical analysis shows that the growth rate of a given nanotube essentially varies between two values, with similar average ratio (~1.7) regardless of whether the rate change is accompanied by a change in chirality. These switches indicate that the nanotube edge or the catalyst nanoparticle fluctuates between different configurations during growth.
△ Less
Submitted 4 October, 2021;
originally announced October 2021.
-
Enhancing the precision limits of interferometric satellite geodesy missions
Authors:
Lorcan Conlon,
Thibault Michel,
Giovanni Guccione,
Kirk McKenzie,
Syed M. Assad,
Ping Koy Lam
Abstract:
Satellite geodesy uses the measurement of the motion of one or more satellites to infer precise information about the Earth's gravitational field. In this work, we consider the achievable precision limits on such measurements by examining approximate models for the three main noise sources in the measurement process of the current Gravitational Recovery and Climate Experiment (GRACE) Follow-On mis…
▽ More
Satellite geodesy uses the measurement of the motion of one or more satellites to infer precise information about the Earth's gravitational field. In this work, we consider the achievable precision limits on such measurements by examining approximate models for the three main noise sources in the measurement process of the current Gravitational Recovery and Climate Experiment (GRACE) Follow-On mission: laser phase noise, accelerometer noise and quantum noise. We show that, through time-delay interferometry, it is possible to remove the laser phase noise from the measurement, allowing for almost three orders of magnitude improvement in the signal-to-noise ratio. Several differential mass satellite formations are presented which can further enhance the signal-to-noise ratio through the removal of accelerometer noise. Finally, techniques from quantum optics have been studied, and found to have great promise for reducing quantum noise in other alternative mission configurations. We model the spectral noise performance using an intuitive 1D model and verify that our proposals have the potential to greatly enhance the performance of near-future satellite geodesy missions.
△ Less
Submitted 8 June, 2022; v1 submitted 15 September, 2021;
originally announced September 2021.
-
Search for Majoron-emitting modes of $^{136}$Xe double beta decay with the complete EXO-200 dataset
Authors:
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling,
A. Dolgolenko,
M. J. Dolinski
, et al. (81 additional authors not shown)
Abstract:
A search for Majoron-emitting modes of the neutrinoless double-beta decay of $^{136}$Xe is performed with the full EXO-200 dataset. This dataset consists of a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr, and includes data with detector upgrades that have improved the energy threshold relative to previous searches. A lower limit of T$_{1/2}^{\rm{^{136}Xe}}>$4.3$\cdot$10$^{24}$ yr at 90\% C.L. on…
▽ More
A search for Majoron-emitting modes of the neutrinoless double-beta decay of $^{136}$Xe is performed with the full EXO-200 dataset. This dataset consists of a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr, and includes data with detector upgrades that have improved the energy threshold relative to previous searches. A lower limit of T$_{1/2}^{\rm{^{136}Xe}}>$4.3$\cdot$10$^{24}$ yr at 90\% C.L. on the half-life of the spectral index $n=1$ Majoron decay was obtained, a factor of 3.6 more stringent than the previous limit from EXO-200, corresponding to a constraint on the Majoron-neutrino coupling constant of $|\langle g_{ee}^{M}\rangle|$$<(0.4$-$0.9)\cdot10^{-5}$. The lower threshold and the additional data taken resulted in a factor 8.4 improvement for the $n=7$ mode compared to the previous EXO search. This search provides the most stringent limits to-date on the Majoron-emitting decays of $^{136}$Xe with spectral indices $n=1,2,3,$ and 7.
△ Less
Submitted 17 November, 2021; v1 submitted 3 September, 2021;
originally announced September 2021.
-
Laser astrophysics experiment on the amplification of magnetic fields by shock-induced interfacial instabilities
Authors:
Takayoshi Sano,
Shohei Tamatani,
Kazuki Matsuo,
King Fai Farley Law,
Taichi Morita,
Shunsuke Egashira,
Masato Ota,
Rajesh Kumar,
Hiroshi Shimogawara,
Yukiko Hara,
Seungho Lee,
Shohei Sakata,
Gabriel Rigon,
Thibault Michel,
Paul Mabey,
Bruno Albertazzi,
Michel Koenig,
Alexis Casner,
Keisuke Shigemori,
Shinsuke Fujioka,
Masakatsu Murakami,
Youichi Sakawa
Abstract:
Laser experiments are becoming established as a new tool for astronomical research that complements observations and theoretical modeling. Localized strong magnetic fields have been observed at a shock front of supernova explosions. Experimental confirmation and identification of the physical mechanism for this observation are of great importance in understanding the evolution of the interstellar…
▽ More
Laser experiments are becoming established as a new tool for astronomical research that complements observations and theoretical modeling. Localized strong magnetic fields have been observed at a shock front of supernova explosions. Experimental confirmation and identification of the physical mechanism for this observation are of great importance in understanding the evolution of the interstellar medium. However, it has been challenging to treat the interaction between hydrodynamic instabilities and an ambient magnetic field in the laboratory. Here, we developed an experimental platform to examine magnetized Richtmyer-Meshkov instability (RMI). The measured growth velocity was consistent with the linear theory, and the magnetic-field amplification was correlated with RMI growth. Our experiment validated the turbulent amplification of magnetic fields associated with the shock-induced interfacial instability in astrophysical conditions for the first time. Experimental elucidation of fundamental processes in magnetized plasmas is generally essential in various situations such as fusion plasmas and planetary sciences.
△ Less
Submitted 26 August, 2021;
originally announced August 2021.
-
The EXO-200 detector, part II: Auxiliary Systems
Authors:
N. Ackerman,
J. Albert,
M. Auger,
D. J. Auty,
I. Badhrees,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
V. Belov,
C. Benitez-Medina,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
R. Conley,
S. Cook,
M. Coon,
W. Craddock,
A. Craycraft,
W. Cree,
T. Daniels,
L. Darroch
, et al. (135 additional authors not shown)
Abstract:
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op…
▽ More
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.
△ Less
Submitted 22 October, 2021; v1 submitted 13 July, 2021;
originally announced July 2021.
-
NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity
Authors:
nEXO Collaboration,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
G. Anton,
I. J. Arnquist,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
D. Chernyak,
M. Chiu,
B. Cleveland
, et al. (136 additional authors not shown)
Abstract:
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the…
▽ More
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.
△ Less
Submitted 22 February, 2022; v1 submitted 30 June, 2021;
originally announced June 2021.
-
Personal Dosimetry in Direct Pulsed Photon Fields with the Dosepix Detector
Authors:
Dennis Haag,
Sebastian Schmidt,
Patrick Hufschmidt,
Gisela Anton,
Rafael Ballabriga,
Rolf Behrens,
Michael Campbell,
Franziska Eberle,
Christian Fuhg,
Oliver Hupe,
Xavier Llopart,
Jürgen Roth,
Lukas Tlustos,
Winnie Wong,
Hayo Zutz,
Thilo Michel
Abstract:
First investigations regarding dosimetric properties of the hybrid, pixelated, photon-counting Dosepix detector in the direct beam of a pulsed photon field (RQR8) for the personal dose equivalent $H\mathrm{_p(10)}$ are presented. The influence quantities such as pulse duration and dose rate were varied, and their responses were compared to the legal limits provided in PTB-A 23.2. The variation of…
▽ More
First investigations regarding dosimetric properties of the hybrid, pixelated, photon-counting Dosepix detector in the direct beam of a pulsed photon field (RQR8) for the personal dose equivalent $H\mathrm{_p(10)}$ are presented. The influence quantities such as pulse duration and dose rate were varied, and their responses were compared to the legal limits provided in PTB-A 23.2. The variation of pulse duration at a nearly constant dose rate of about 3.7$\,$Sv/h shows a flat response around 1.0 from 3.6$\,$s down to 2$\,$ms. A response close to 1.0 is achieved for dose rates from 0.07$\,$Sv/h to 35$\,$Sv/h for both pixel sizes. Above this dose rate, the large pixels (220$\,μ$m edge length) are below the lower limit. The small pixels (55$\,μ$m edge length) stay within limits up to 704$\,$Sv/h. The count rate linearity is compared to previous results, confirming the saturating count rate for high dose rates.
△ Less
Submitted 30 November, 2022; v1 submitted 12 June, 2021;
originally announced June 2021.
-
Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
Authors:
M. Wagenpfeil,
T. Ziegler,
J. Schneider,
A. Fieguth,
M. Murra,
D. Schulte,
L. Althueser,
C. Huhmann,
C. Weinheimer,
T. Michel,
G. Anton,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
I. Badhrees,
J. Bane,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (118 additional authors not shown)
Abstract:
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows t…
▽ More
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20° for the four samples and increases to up to 65% at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.
△ Less
Submitted 26 May, 2021; v1 submitted 16 April, 2021;
originally announced April 2021.
-
Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage
Authors:
T. Stiegler,
S. Sangiorgio,
J. P. Brodsky,
M. Heffner,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon
, et al. (126 additional authors not shown)
Abstract:
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier…
▽ More
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. In this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the $γ$-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Second, background from ${}^{222}Rn$ dissolved in the skin LXe can be efficiently rejected by tagging the $α$ decay in the ${}^{214}Bi-{}^{214}Po$ chain in the skin LXe.
△ Less
Submitted 24 March, 2021; v1 submitted 21 September, 2020;
originally announced September 2020.
-
Supporting the Supporters of Unaccompanied Migrant Youth: Designing for Social-ecological Resilience
Authors:
Franziska Tachtler,
Toni Michel,
Petr Slovák,
Geraldine Fitzpatrick
Abstract:
Unaccompanied migrant youth, fleeing to a new country without their parents, are exposed to mental health risks. Resilience interventions mitigate such risks, but access can be hindered by systemic and personal barriers. While much work has recently addressed designing technology to promote mental health, none has focused on the needs of these populations. This paper presents the results of interv…
▽ More
Unaccompanied migrant youth, fleeing to a new country without their parents, are exposed to mental health risks. Resilience interventions mitigate such risks, but access can be hindered by systemic and personal barriers. While much work has recently addressed designing technology to promote mental health, none has focused on the needs of these populations. This paper presents the results of interviews with 18 professional/ volunteer support workers and 5 unaccompanied migrant youths, followed by three design workshops. The results point to the diverse systems that can facilitate youths' resilience development. The relationship between the youth and volunteers acting as mentors is particularly important for increasing resilience but comes with challenges. This suggests the relevance of a social-ecological model of resilience with a focus on designing technology to support the mentors in order to help them better support the youth. We conclude by mapping out the design space for mentor support.
△ Less
Submitted 10 March, 2020;
originally announced March 2020.
-
Measurement of the Spectral Shape of the beta-decay of 137Xe to the Ground State of 137Cs in EXO-200 and Comparison with Theory
Authors:
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling,
A. Dolgolenko,
M. J. Dolinski
, et al. (83 additional authors not shown)
Abstract:
We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden non-unique $β$-decay transition $^{137}\textrm{Xe}(7/2^-)\to\,^{137}\textrm{Cs}(7/2^+)$. The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultra-low background environment of EXO-200, together with dedicated source d…
▽ More
We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden non-unique $β$-decay transition $^{137}\textrm{Xe}(7/2^-)\to\,^{137}\textrm{Cs}(7/2^+)$. The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultra-low background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal-to-background ratio of more than 99-to-1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden non-unique $β$-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.
△ Less
Submitted 7 May, 2020; v1 submitted 31 January, 2020;
originally announced February 2020.
-
Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
Authors:
P. Lv,
G. F. Cao,
L. J. Wen,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon,
A. Craycraft
, et al. (126 additional authors not shown)
Abstract:
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinct…
▽ More
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinction coefficient of the thin silicon-dioxide film deposited on the surface of the FBK SiPMs are derived from reflectance data of a FBK silicon wafer with the same deposited oxide film as SiPMs. The diffuse reflectance of SiPMs is also measured at 193 nm. We use the VUV spectral dependence of the optical constants to predict the reflectance of the FBK silicon wafer and FBK SiPMs in liquid xenon.
△ Less
Submitted 4 December, 2019;
originally announced December 2019.
-
Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode
Authors:
O. Njoya,
T. Tsang,
M. Tarka,
W. Fairbank,
K. S. Kumar,
T. Rao,
T. Wager,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (131 additional authors not shown)
Abstract:
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measur…
▽ More
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are $1.97 \pm 0.04$ mm/$μ$s and $(-0.69\pm0.05)$\%/K for liquid xenon, and $1.42 \pm 0.03$ mm/$μ$s and $(+0.11\pm0.01)$\%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of $25.7 \pm 4.6$ cm$^2$/s and $149 \pm 23$ cm$^2$/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.
△ Less
Submitted 24 November, 2019;
originally announced November 2019.
-
Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon
Authors:
P. Nakarmi,
I. Ostrovskiy,
A. K. Soma,
F. Retiere,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (130 additional authors not shown)
Abstract:
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently a…
▽ More
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 micrometer micro-cells conducted with xenon scintillation light (~175 nm) in liquid xenon. The specular reflectivity at 15 deg. incidence of three samples of VUV4 SiPMs is found to be 30.4+/-1.4%, 28.6+/-1.3%, and 28.0+/-1.3%, respectively. The PDE at normal incidence differs by +/-8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was also measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.
△ Less
Submitted 24 December, 2019; v1 submitted 14 October, 2019;
originally announced October 2019.
-
Leveraging Model Interpretability and Stability to increase Model Robustness
Authors:
Fei Wu,
Thomas Michel,
Alexandre Briot
Abstract:
State of the art Deep Neural Networks (DNN) can now achieve above human level accuracy on image classification tasks. However their outstanding performances come along with a complex inference mechanism making them arduously interpretable models. In order to understand the underlying prediction rules of DNNs, Dhamdhere et al. propose an interpretability method to break down a DNN prediction score…
▽ More
State of the art Deep Neural Networks (DNN) can now achieve above human level accuracy on image classification tasks. However their outstanding performances come along with a complex inference mechanism making them arduously interpretable models. In order to understand the underlying prediction rules of DNNs, Dhamdhere et al. propose an interpretability method to break down a DNN prediction score as sum of its hidden unit contributions, in the form of a metric called conductance. Analyzing conductances of DNN hidden units, we find out there is a difference in how wrong and correct predictions are inferred. We identify distinguishable patterns of hidden unit activations for wrong and correct predictions. We then use an error detector in the form of a binary classifier on top of the DNN to automatically discriminate wrong and correct predictions of the DNN based on their hidden unit activations. Detected wrong predictions are discarded, increasing the model robustness. A different approach to distinguish wrong and correct predictions of DNNs is proposed by Wang et al. whose method is based on the premise that input samples leading a DNN into making wrong predictions are less stable to the DNN weight changes than correctly classified input samples. In our study, we compare both methods and find out by combining them that better detection of wrong predictions can be achieved.
△ Less
Submitted 5 November, 2019; v1 submitted 1 October, 2019;
originally announced October 2019.
-
Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment
Authors:
EXO-200 Collaboration,
:,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling,
A. Dolgolenko
, et al. (78 additional authors not shown)
Abstract:
Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $γ$ interactions from $^{228}$Th (2615~keV), $^{226}$Ra (1764~keV) and $^{60}$Co (1332~keV and 1173~keV) calibration sources, over a range of electric fields. The $W$-value that defines the…
▽ More
Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $γ$ interactions from $^{228}$Th (2615~keV), $^{226}$Ra (1764~keV) and $^{60}$Co (1332~keV and 1173~keV) calibration sources, over a range of electric fields. The $W$-value that defines the recombination-independent energy scale is measured to be $11.5~\pm~0.5$~(syst.)~$\pm~0.1$~(stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV-scale, which deviate from extrapolations of lower-energy data. Additionally, a semi-empirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double beta decay detectors.
△ Less
Submitted 15 June, 2020; v1 submitted 12 August, 2019;
originally announced August 2019.
-
Simulation of charge readout with segmented tiles in nEXO
Authors:
Z. Li,
W. R. Cen,
A. Robinson,
D. C. Moore,
L. J. Wen,
A. Odian,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland
, et al. (128 additional authors not shown)
Abstract:
nEXO is a proposed experiment to search for the neutrino-less double beta decay ($0νββ$) of $^{136}$Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neu…
▽ More
nEXO is a proposed experiment to search for the neutrino-less double beta decay ($0νββ$) of $^{136}$Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neural network are developed to distinguish simulated $0νββ$ signals from backgrounds arising from trace levels of natural radioactivity in the detector materials. These simulations indicate that the nEXO TPC with charge-collection tiles shows promising capability to discriminate the $0νββ$ signal from backgrounds. The estimated half-life sensitivity for $0νββ$ decay is improved by $\sim$20$~(32)\%$ with the multi-variate~(deep neural network) methods considered here, relative to the sensitivity estimated in the nEXO pre-conceptual design report.
△ Less
Submitted 11 October, 2019; v1 submitted 17 July, 2019;
originally announced July 2019.
-
Search for Neutrinoless Double-Beta Decay with the Complete EXO-200 Dataset
Authors:
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling,
A. Dolgolenko,
M. J. Dolinski
, et al. (77 additional authors not shown)
Abstract:
A search for neutrinoless double-beta decay ($0νββ$) in $^{136}$Xe is performed with the full EXO-200 dataset using a deep neural network to discriminate between $0νββ$ and background events. Relative to previous analyses, the signal detection efficiency has been raised from 80.8% to 96.4$\pm$3.0% and the energy resolution of the detector at the Q-value of $^{136}$Xe $0νββ$ has been improved from…
▽ More
A search for neutrinoless double-beta decay ($0νββ$) in $^{136}$Xe is performed with the full EXO-200 dataset using a deep neural network to discriminate between $0νββ$ and background events. Relative to previous analyses, the signal detection efficiency has been raised from 80.8% to 96.4$\pm$3.0% and the energy resolution of the detector at the Q-value of $^{136}$Xe $0νββ$ has been improved from $σ/E=1.23\%$ to $1.15\pm0.02\%$ with the upgraded detector. Accounting for the new data, the median 90% confidence level $0νββ$ half-life sensitivity for this analysis is $5.0 \cdot 10^{25}$ yr with a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr. No statistically significant evidence for $0νββ$ is observed, leading to a lower limit on the $0νββ$ half-life of $3.5\cdot10^{25}$ yr at the 90% confidence level.
△ Less
Submitted 18 October, 2019; v1 submitted 6 June, 2019;
originally announced June 2019.
-
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Authors:
G. Gallina,
P. Giampa,
F. Retiere,
J. Kroeger,
G. Zhang,
M. Ward,
P. Margetak,
G. Lic,
T. Tsang,
L. Doria,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
J. P. Brodsky,
E. Brown,
T. Brunner,
G. F. Cao,
L. Cao
, et al. (126 additional authors not shown)
Abstract:
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency…
▽ More
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
△ Less
Submitted 7 June, 2019; v1 submitted 8 March, 2019;
originally announced March 2019.
-
Real-Time Source Independent Quantum Random Number Generator with Squeezed States
Authors:
Thibault Michel,
Jing Yan Haw,
Davide G. Marangon,
Oliver Thearle,
Giuseppe Vallone,
Paolo Villoresi,
Ping Koy Lam,
Syed M. Assad
Abstract:
Random numbers are a fundamental ingredient for many applications including simulation, modelling and cryptography. Sound random numbers should be independent and uniformly distributed. Moreover, for cryptographic applications they should also be unpredictable. We demonstrate a real-time self-testing source independent quantum random number generator (QRNG) that uses squeezed light as source. We g…
▽ More
Random numbers are a fundamental ingredient for many applications including simulation, modelling and cryptography. Sound random numbers should be independent and uniformly distributed. Moreover, for cryptographic applications they should also be unpredictable. We demonstrate a real-time self-testing source independent quantum random number generator (QRNG) that uses squeezed light as source. We generate secure random numbers by measuring the quadratures of the electromagnetic field without making any assumptions on the source; only the detection device is trusted. We use a homodyne detection to alternatively measure the Q and P conjugate quadratures of our source. Using the entropic uncertainty relation, measurements on P allow us to estimate a bound on the min-entropy of Q conditioned on any classical or quantum side information that a malicious eavesdropper may detain. This bound gives the minimum number of secure bits we can extract from the Q measurement. We discuss the performance of different estimators for this bound. We operate this QRNG with a squeezed state and we compare its performance with a QRNG using thermal states. The real-time bit rate was 8.2 kb/s when using the squeezed source and between 5.2-7.2 kb/s when the thermal state source was used.
△ Less
Submitted 4 March, 2019;
originally announced March 2019.
-
Non-Gaussian quantum states of a multimode light field
Authors:
Young-Sik Ra,
Adrien Dufour,
Mattia Walschaers,
Clément Jacquard,
Thibault Michel,
Claude Fabre,
Nicolas Treps
Abstract:
Even though Gaussian quantum states of multimode light are promising quantum resources due to their scalability, non-Gaussianity is indispensable for quantum technologies, in particular to reach quantum computational advantage. However, embodying non-Gaussianity in a multimode Gaussian state remains a challenge as controllable non-Gaussian operations are hard to implement in a multimode scenario.…
▽ More
Even though Gaussian quantum states of multimode light are promising quantum resources due to their scalability, non-Gaussianity is indispensable for quantum technologies, in particular to reach quantum computational advantage. However, embodying non-Gaussianity in a multimode Gaussian state remains a challenge as controllable non-Gaussian operations are hard to implement in a multimode scenario. Here, we report the first generation of non-Gaussian quantum states of a multimode light field by subtracting a photon in a desired mode from multimode Gaussian states, and observe negativity of the Wigner function. For entangled Gaussian states, we observe that photon subtraction makes non-Gaussianity spread among various entangled modes. In addition to applications in quantum technologies, our results shed new light on non-Gaussian multimode entanglement with particular emphasis on quantum networks.
△ Less
Submitted 30 January, 2019;
originally announced January 2019.
-
A comprehensive model of the optical spectra of carbon nanotubes on substrate by polarized microscopy
Authors:
Léonard Monniello,
Huy-Nam Tran,
Rémy Vialla,
Guillaume Prévot,
Said Tahir,
Thierry Michel,
Vincent Jourdain
Abstract:
Polarized optical microscopy and spectroscopy are progressively becoming key methods for the high-throughput characterization of individual carbon nanotubes (CNTs) and other one-dimensional nanostructures, on substrate and in devices. The optical response of CNTs on substrate in cross polarization experiments is usually limited by the polarization conservation of the optical elements in the experi…
▽ More
Polarized optical microscopy and spectroscopy are progressively becoming key methods for the high-throughput characterization of individual carbon nanotubes (CNTs) and other one-dimensional nanostructures, on substrate and in devices. The optical response of CNTs on substrate in cross polarization experiments is usually limited by the polarization conservation of the optical elements in the experimental setup. We developed a theoretical model taking into account the depolarization by the setup and the optical response of the substrate. We show that proper modelization of the experimental data requires to take into account both non-coherent and coherent light depolarization by the optical elements. We also show how the nanotube signal can be decoupled from the complex reflection factor of the anti-reflection substrate which is commonly used to enhance the optical contrast. Finally, we describe an experimental protocol to extract the depolarization parameters and the complex nanotube susceptibility, and how it can improve the chirality assignment of individual carbon nanotubes in complex cases.
△ Less
Submitted 23 November, 2018;
originally announced November 2018.
-
Study of Silicon Photomultiplier Performance in External Electric Fields
Authors:
X. L. Sun,
T. Tolba,
G. F. Cao,
P. Lv,
L. J. Wen,
A. Odian,
F. Vachon,
A. Alamre,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois
, et al. (127 additional authors not shown)
Abstract:
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estima…
▽ More
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estimated uncertainties. No observable physical damage to the bulk or surface of the devices was caused by the exposure.
△ Less
Submitted 9 July, 2018;
originally announced July 2018.
-
Imaging individual barium atoms in solid xenon for barium tagging in nEXO
Authors:
C. Chambers,
T. Walton,
D. Fairbank,
A. Craycraft,
D. R. Yahne,
J. Todd,
A. Iverson,
W. Fairbank,
A. Alamare,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen
, et al. (126 additional authors not shown)
Abstract:
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a…
▽ More
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a technique for eliminating backgrounds in the nEXO neutrinoless double beta decay experiment. The tagging scheme studied in this work utilizes a cryogenic probe to trap the barium atom in solid xenon, where the barium atom is tagged via fluorescence imaging in the solid xenon matrix. Here we demonstrate imaging and counting of individual atoms of barium in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser sits on an individual atom, the fluorescence persists for $\sim$30~s before dropping abruptly to the background level, a clear confirmation of one-atom imaging. No barium fluorescence persists following evaporation of a barium deposit to a limit of $\leq$0.16\%. This is the first time that single atoms have been imaged in solid noble element. It establishes the basic principle of a barium tagging technique for nEXO.
△ Less
Submitted 12 December, 2018; v1 submitted 27 June, 2018;
originally announced June 2018.
-
VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO
Authors:
A. Jamil,
T. Ziegler,
P. Hufschmidt,
G. Li,
L. Lupin-Jimenez,
T. Michel,
I. Ostrovskiy,
F. Retière,
J. Schneider,
M. Wagenpfeil,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. Barbeau,
D. Beck,
V. Belov,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers
, et al. (118 additional authors not shown)
Abstract:
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting t…
▽ More
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting the $178\,\text{nm}$ xenon scintillation light, in order to achieve an energy resolution of $σ/ Q_{ββ} = 1\, \%$. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler in two complementary setups. It includes measurements of the photon detection efficiency with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. We report improved photon detection efficiency at $175\,\text{nm}$ compared to previous generation devices, that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.
△ Less
Submitted 13 March, 2019; v1 submitted 6 June, 2018;
originally announced June 2018.
-
nEXO Pre-Conceptual Design Report
Authors:
nEXO Collaboration,
S. Al Kharusi,
A. Alamre,
J. B. Albert,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
R. Conley
, et al. (149 additional authors not shown)
Abstract:
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of app…
▽ More
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of approximately $10^{28}$ years. This represents an improvement in sensitivity of about two orders of magnitude with respect to current results. Based on the experience gained from EXO-200 and the effectiveness of xenon purification techniques, we expect the background to be dominated by external sources of radiation. The sensitivity increase is, therefore, entirely derived from the increase of active mass in a monolithic and homogeneous detector, along with some technical advances perfected in the course of a dedicated R&D program. Hence the risk which is inherent to the construction of a large, ultra-low background detector is reduced, as the intrinsic radioactive contamination requirements are generally not beyond those demonstrated with the present generation $0νββ$ decay experiments. Indeed, most of the required materials have been already assayed or reasonable estimates of their properties are at hand. The details described herein represent the base design of the detector configuration as of early 2018. Where potential design improvements are possible, alternatives are discussed.
This design for nEXO presents a compelling path towards a next generation search for $0νββ$, with a substantial possibility to discover physics beyond the Standard Model.
△ Less
Submitted 13 August, 2018; v1 submitted 28 May, 2018;
originally announced May 2018.
-
Phase-Sensitive Region-of-Interest Computed Tomography
Authors:
Lina Felsner,
Martin Berger,
Sebastian Kaeppler,
Johannes Bopp,
Veronika Ludwig,
Thomas Weber,
Georg Pelzer,
Thilo Michel,
Andreas Maier,
Gisela Anton,
Christian Riess
Abstract:
X-Ray Phase-Contrast Imaging (PCI) yields absorption, differential phase, and dark-field images. Computed Tomography (CT) of grating-based PCI can in principle provide high-resolution soft-tissue contrast. Recently, grating-based PCI took several hurdles towards clinical implementation by addressing, for example, acquisition speed, high X-ray energies, and system vibrations. However, a critical im…
▽ More
X-Ray Phase-Contrast Imaging (PCI) yields absorption, differential phase, and dark-field images. Computed Tomography (CT) of grating-based PCI can in principle provide high-resolution soft-tissue contrast. Recently, grating-based PCI took several hurdles towards clinical implementation by addressing, for example, acquisition speed, high X-ray energies, and system vibrations. However, a critical impediment in all grating-based systems lies in limits that constrain the grating diameter to few centimeters. In this work, we propose a system and a reconstruction algorithm to circumvent this constraint in a clinically compatible way. We propose to perform a phase-sensitive Region-of-Interest (ROI) CT within a full-field absorption CT. The biggest advantage of this approach is that it allows to correct for phase truncation artifacts, and to obtain quantitative phase values. Our method is robust, and shows high-quality results on simulated data and on a biological mouse sample. This work is a proof of concept showing the potential to use PCI in CT on large specimen, such as humans, in clinical applications.
△ Less
Submitted 24 May, 2018;
originally announced May 2018.
-
Deep Neural Networks for Energy and Position Reconstruction in EXO-200
Authors:
S. Delaquis,
M. J. Jewell,
I. Ostrovskiy,
M. Weber,
T. Ziegler,
J. Dalmasson,
L. J. Kaufman,
T. Richards,
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree,
T. Daniels
, et al. (69 additional authors not shown)
Abstract:
We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters - total energy and position - directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what…
▽ More
We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters - total energy and position - directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what was achieved by the conventional approaches developed by EXO-200 over the course of the experiment. Most existing DNN approaches to event reconstruction and classification in particle physics are trained on Monte Carlo simulated events. Such algorithms are inherently limited by the accuracy of the simulation. We describe a unique approach that, in an experiment such as EXO-200, allows to successfully perform certain reconstruction and analysis tasks by training the network on waveforms from experimental data, either reducing or eliminating the reliance on the Monte Carlo.
△ Less
Submitted 30 August, 2018; v1 submitted 25 April, 2018;
originally announced April 2018.
-
Laboratory radiative accretion shocks on GEKKO XII laser facility for POLAR project
Authors:
L. Van Box Som,
E. Falize,
M. Koenig,
Y. Sakawa,
B. Albertazzi,
P. Barroso,
J. -M. Bonnet-Bidaud,
C. Busschaert,
A. Ciardi,
Y. Hara,
N. Katsuki,
R. Kumar,
F. Lefevre,
C. Michaut,
Th. Michel,
T. Miura,
T. Morita,
M. Mouchet,
G. Rigon,
T. Sano,
S. Shiiba,
H. Shimogawara,
S. Tomiya
Abstract:
A new target design is presented to model high-energy radiative accretion shocks in polars. In this paper, we present the experimental results obtained on the GEKKO XII laser facility for the POLAR project. The experimental results are compared with 2D FCI2 simulations to characterize the dynamics and the structure of plasma flow before and after the collision. The good agreement between simulatio…
▽ More
A new target design is presented to model high-energy radiative accretion shocks in polars. In this paper, we present the experimental results obtained on the GEKKO XII laser facility for the POLAR project. The experimental results are compared with 2D FCI2 simulations to characterize the dynamics and the structure of plasma flow before and after the collision. The good agreement between simulations and experimental data confirm the formation of a reverse shock where cooling losses start modifying the post-shock region. With the multi-material structure of the target, a hydrodynamic collimation is exhibited and a radiative structure coupled with the reverse shock is highlighted in both experimental data and simulations. The flexibility on the laser energy produced on GEKKO XII, allowed us to produce high-velocity flows and study new and interesting radiation hydrodynamic regimes between those obtained on the LULI2000 and Orion laser facilities.
△ Less
Submitted 8 April, 2018;
originally announced April 2018.
-
Search for nucleon decays with EXO-200
Authors:
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree,
T. Daniels,
M. Danilov,
S. J. Daugherty,
J. Daughhetee,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze
, et al. (70 additional authors not shown)
Abstract:
A search for instability of nucleons bound in $^{136}$Xe nuclei is reported with 223 kg$\cdot$yr exposure of $^{136}$Xe in the EXO-200 experiment. Lifetime limits of 3.3$\times 10^{23}$ and 1.9$\times 10^{23}$ yrs are established for nucleon decay to $^{133}$Sb and $^{133}$Te, respectively. These are the most stringent to date, exceeding the prior decay limits by a factor of 9 and 7, respectively.
A search for instability of nucleons bound in $^{136}$Xe nuclei is reported with 223 kg$\cdot$yr exposure of $^{136}$Xe in the EXO-200 experiment. Lifetime limits of 3.3$\times 10^{23}$ and 1.9$\times 10^{23}$ yrs are established for nucleon decay to $^{133}$Sb and $^{133}$Te, respectively. These are the most stringent to date, exceeding the prior decay limits by a factor of 9 and 7, respectively.
△ Less
Submitted 11 April, 2018; v1 submitted 20 October, 2017;
originally announced October 2017.
-
Characterization of an Ionization Readout Tile for nEXO
Authors:
nEXO Collaboration,
M. Jewell,
A. Schubert,
W. R. Cen,
J. Dalmasson,
R. DeVoe,
L. Fabris,
G. Gratta,
A. Jamil,
G. Li,
A. Odian,
M. Patel,
A. Pocar,
D. Qiu,
Q. Wang,
L. J. Wen,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. Barbeau,
D. Beck,
V. Belov,
F. Bourque,
J. P. Brodsky
, et al. (120 additional authors not shown)
Abstract:
A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale n…
▽ More
A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a $^{207}$Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution $σ/E$=5.5\% is observed at 570~\si{keV}, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936~V/\si{cm}.
△ Less
Submitted 19 January, 2018; v1 submitted 13 October, 2017;
originally announced October 2017.
-
Sensitivity and discovery potential of the proposed nEXO experiment to neutrinoless double beta decay
Authors:
nEXO Collaboration,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon,
M. Côté,
A. Craycraft,
W. Cree,
J. Dalmasson
, et al. (121 additional authors not shown)
Abstract:
The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta ($0νββ$) decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by…
▽ More
The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta ($0νββ$) decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by a significant increase of the $^{136}$Xe mass, the monolithic and homogeneous configuration of the active medium, and the multi-parameter measurements of the interactions enabled by the time projection chamber. The detector concept and anticipated performance are presented based upon demonstrated realizable background rates.
△ Less
Submitted 19 October, 2018; v1 submitted 13 October, 2017;
originally announced October 2017.
-
Search for Neutrinoless Double-Beta Decay with the Upgraded EXO-200 Detector
Authors:
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree,
T. Daniels,
M. Danilov,
S. J. Daugherty,
J. Daughhetee,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze
, et al. (68 additional authors not shown)
Abstract:
Results from a search for neutrinoless double-beta decay $0νββ$ of $^{136}$Xe are presented using the first year of data taken with the upgraded EXO-200 detector. Relative to previous searches by EXO-200, the energy resolution of the detector has been improved to $σ/E$=1.23%, the electric field in the drift region has been raised by 50%, and a system to suppress radon in the volume between the cry…
▽ More
Results from a search for neutrinoless double-beta decay $0νββ$ of $^{136}$Xe are presented using the first year of data taken with the upgraded EXO-200 detector. Relative to previous searches by EXO-200, the energy resolution of the detector has been improved to $σ/E$=1.23%, the electric field in the drift region has been raised by 50%, and a system to suppress radon in the volume between the cryostat and lead shielding has been implemented. In addition, analysis techniques that improve topological discrimination between $0νββ$ and background events have been developed. Incorporating these hardware and analysis improvements, the median 90% confidence level $0νββ$ half-life sensitivity after combining with the full data set acquired before the upgrade has increased 2-fold to $3.7 \times 10^{25}$ yr. No statistically significant evidence for $0νββ$ is observed, leading to a lower limit on the $0νββ$ half-life of $1.8\times10^{25}$ yr at the 90% confidence level.
△ Less
Submitted 26 February, 2018; v1 submitted 27 July, 2017;
originally announced July 2017.
-
Searches for Double Beta Decay of $^{134}$Xe with EXO-200
Authors:
EXO-200 Collaboration,
:,
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree,
T. Daniels,
M. Danilov,
S. J. Daugherty,
J. Daughhetee,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian
, et al. (69 additional authors not shown)
Abstract:
Searches for double beta decay of $^{134}$Xe were performed with EXO-200, a single-phase liquid xenon detector designed to search for neutrinoless double beta decay of $^{136}$Xe. Using an exposure of $29.6\text{ kg}\!\cdot\!\text{yr}$, the lower limits of $\text{T}_{1/2}^{2νβ\!β}>8.7\cdot10^{20}\text{ yr}$ and $\text{T}_{1/2}^{0νβ\!β}>1.1\cdot10^{23}\text{ yr}$ at 90% confidence level were derive…
▽ More
Searches for double beta decay of $^{134}$Xe were performed with EXO-200, a single-phase liquid xenon detector designed to search for neutrinoless double beta decay of $^{136}$Xe. Using an exposure of $29.6\text{ kg}\!\cdot\!\text{yr}$, the lower limits of $\text{T}_{1/2}^{2νβ\!β}>8.7\cdot10^{20}\text{ yr}$ and $\text{T}_{1/2}^{0νβ\!β}>1.1\cdot10^{23}\text{ yr}$ at 90% confidence level were derived, with corresponding half-life sensitivities of $1.2\cdot10^{21}\text{ yr}$ and $1.9\cdot10^{23}\text{ yr}$. These limits exceed those in the literature for $^{134}$Xe, improving by factors of nearly $10^{5}$ and 2 for the two antineutrino and neutrinoless modes, respectively.
△ Less
Submitted 6 November, 2017; v1 submitted 17 April, 2017;
originally announced April 2017.
-
Trace radioactive impurities in final construction materials for EXO-200
Authors:
D. S. Leonard,
D. Auty,
T. Didberidze,
R. Gornea,
P. Grinberg,
R. MacLellan,
B. Methven,
A. Piepke,
J. -L. Vuilleumier,
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree
, et al. (76 additional authors not shown)
Abstract:
We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial results from this campaign have already been reported in a 2008 paper by the EXO collaboration. Here we release the remaining data, collected since 2007, to the public. The data reported were obtained using a variety of…
▽ More
We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial results from this campaign have already been reported in a 2008 paper by the EXO collaboration. Here we release the remaining data, collected since 2007, to the public. The data reported were obtained using a variety of analytic techniques. The measurement sensitivities are among the best in the field. Construction of the EXO-200 detector has been concluded, and Phase-I data was taken from 2011 to 2014. The detector's extremely low background implicitly verifies the measurements and the analysis assumptions made during construction and reported in this paper.
△ Less
Submitted 31 March, 2017;
originally announced March 2017.
-
A search for the radiative neutrinoless double electron capture of $^{58}$Ni
Authors:
B. Lehnert,
D. Degering,
A. Frotscher,
T. Michel,
K. Zuber
Abstract:
A search for the radiative neutrinoless double electron capture with single \gray\ emission has been performed in $^{58}$Ni. Gamma radiation from a 7286 g nickel sample in natural isotope composition was measured for 58.3 d with an ultra low background HPGe detector in the Felsenkeller underground laboratory in Dresden, Germany. A new lower half-life limit of $2.1 \times 10^{21}$ yr (90% CL) was o…
▽ More
A search for the radiative neutrinoless double electron capture with single \gray\ emission has been performed in $^{58}$Ni. Gamma radiation from a 7286 g nickel sample in natural isotope composition was measured for 58.3 d with an ultra low background HPGe detector in the Felsenkeller underground laboratory in Dresden, Germany. A new lower half-life limit of $2.1 \times 10^{21}$ yr (90% CL) was obtained for this decay mode. This half-life limit is two orders of magnitude higher than the existing limit for $^{58}$Ni and among the best half-life limits for neutrinoless double electron capture decays.
△ Less
Submitted 11 May, 2016;
originally announced May 2016.
-
The COBRA demonstrator at the LNGS underground laboratory
Authors:
The COBRA collaboration,
J. Ebert,
M. Fritts,
D. Gehre,
C. Gößling,
T. Göpfert,
C. Hagner,
N. Heidrich,
R. Klingenberg,
T. Köttig,
K. Kröninger,
T. Michel,
T. Neddermann,
C. Nitsch,
C. Oldorf,
T. Quante,
S. Rajek,
H. Rebber,
O. Reinecke,
K. Rohatsch,
O. Schulz,
A. Sörensen,
I. Stekl,
J. Tebrügge,
R. Temminghoff
, et al. (6 additional authors not shown)
Abstract:
The COBRA demonstrator, a prototype for a large-scale experiment searching for neutrinoless double beta-decay, was built at the underground laboratory Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It consists of an array of 64 monolithic, calorimetric CdZnTe semiconductor detectors with a coplanar-grid design and a total mass of 380g. It is used to investigate the experimental challenges fa…
▽ More
The COBRA demonstrator, a prototype for a large-scale experiment searching for neutrinoless double beta-decay, was built at the underground laboratory Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It consists of an array of 64 monolithic, calorimetric CdZnTe semiconductor detectors with a coplanar-grid design and a total mass of 380g. It is used to investigate the experimental challenges faced when operating CdZnTe detectors in low-background mode, to identify potential background sources and to show the long-term stability of the detectors. The first data-taking period started in 2011 with a subset of the detectors, while the demonstrator was completed in November 2013. To date, more than 250kg d of data have been collected. This paper describes technical details of the experimental setup and the hardware components.
△ Less
Submitted 18 November, 2015; v1 submitted 29 July, 2015;
originally announced July 2015.
-
Detection of non-classical space-time correlations with a novel type of single-photon camera
Authors:
Felix Just,
Mykhaylo Filipenko,
Andrea Cavanna,
Thilo Michel,
Thomas Gleixner,
Michael Taheri,
John Vallerga,
Michael Campbell,
Timo Tick,
Gisela Anton,
Maria V. Chekhova,
Gerd Leuchs
Abstract:
During the last decades, multi-pixel detectors have been developed capable of registering single photons. The newly developed Hybrid Photon Detector camera has a remarkable property that it has not only spatial but also temporal resolution. In this work, we use this device for the detection of non-classical light from spontaneous parametric down-conversion and use two-photon correlations for the a…
▽ More
During the last decades, multi-pixel detectors have been developed capable of registering single photons. The newly developed Hybrid Photon Detector camera has a remarkable property that it has not only spatial but also temporal resolution. In this work, we use this device for the detection of non-classical light from spontaneous parametric down-conversion and use two-photon correlations for the absolute calibration of its quantum efficiency.
△ Less
Submitted 28 April, 2014;
originally announced April 2014.
-
Three dimensional photograph of single electron tracks through a scintillator
Authors:
Mykhaylo Filipenko,
Timur Ishakov,
Patrick Hufschmidt,
Gisela Anton,
Michael Campbell,
Thomas Gleixner,
Gerd Leuchs,
Timo Tick,
John Vallerga,
Michael Wagenpfeil,
Thilo Michel
Abstract:
The reconstruction of particle trajectories makes it possible to distinguish between different types of charged particles. In high-energy physics, where trajectories are rather long, large size trackers must be used to achieve sufficient position resolution. However, in low-background experiments tracks are rather short and three dimensional trajectories could only be resolved in time-projection c…
▽ More
The reconstruction of particle trajectories makes it possible to distinguish between different types of charged particles. In high-energy physics, where trajectories are rather long, large size trackers must be used to achieve sufficient position resolution. However, in low-background experiments tracks are rather short and three dimensional trajectories could only be resolved in time-projection chambers so far. For detectors of large volume and therefore large drift distances, which are inevitable for low-background experiments, this technique is limited by diffusion of charge carriers. In this work we present a "proof-of-principle" experiment for a new method for the three dimensional tracking of charged particles by scintillation light: We used a setup consisting of a scintillator, mirrors, lenses and a novel imaging device (the hybrid photo detector) in order to image two projections of electron tracks through the scintillator. We took data at the T-24 beam-line at DESY with relativistic electrons with a kinetic energy of 5 GeV and from this data successfully reconstructed their three dimensional propagetion path in the scintillator. With our setup we achieved a position resolution of about 28 mum in the best case.
△ Less
Submitted 22 April, 2014; v1 submitted 15 April, 2014;
originally announced April 2014.
-
3D Particle Track Reconstrution in a Single Layer Cadmium-Telluride Hybrid Active Pixel Detector
Authors:
Mykhaylo Filipenko,
Thomas Gleixner,
Gisela Anton,
Thilo Michel
Abstract:
In the past 20 years the search for neutrinoless double beta decay has driven many developements in all kind of detector technology. A new branch in this field are highly-pixelated semiconductor detectors - such as the CdTe-Timepix detectors. It compromises a cadmium-telluride sensor of 14 mm x 14 mm x 1 mm size with an ASIC which has 256 x 256 pixel of 55 \textmu m pixel pitch and can be used to…
▽ More
In the past 20 years the search for neutrinoless double beta decay has driven many developements in all kind of detector technology. A new branch in this field are highly-pixelated semiconductor detectors - such as the CdTe-Timepix detectors. It compromises a cadmium-telluride sensor of 14 mm x 14 mm x 1 mm size with an ASIC which has 256 x 256 pixel of 55 \textmu m pixel pitch and can be used to obtain either spectroscopic or timing information in every pixel. In regular operation it can provide a 2D projection of particle trajectories; however, three dimensional trajectories are desirable for neutrinoless double beta decay and other applications. In this paper we present a method to obtain such trajectories. The method was developed and tested with simulations that assume some minor modifications to the Timepix ASIC. Also, we were able to test the method experimentally and in the best case achieved a position resolution of about 90 \textmu m with electrons of 4.4 GeV.
△ Less
Submitted 24 March, 2014;
originally announced March 2014.
-
Simultaneous maximum-likelihood reconstruction for x-ray grating based phase-contrast tomography avoiding intermediate phase retrieval
Authors:
André Ritter,
Florian Bayer,
Jürgen Durst,
Karl Gödel,
Wilhelm Haas,
Thilo Michel,
Jens Rieger,
Thomas Weber,
Lukas Wucherer,
Gisela Anton
Abstract:
Phase-wrapping artifacts, statistical image noise and the need for a minimum amount of phase steps per projection limit the practicability of x-ray grating based phase-contrast tomography, when using filtered back projection reconstruction. For conventional x-ray computed tomography, the use of statistical iterative reconstruction algorithms has successfully reduced artifacts and statistical issue…
▽ More
Phase-wrapping artifacts, statistical image noise and the need for a minimum amount of phase steps per projection limit the practicability of x-ray grating based phase-contrast tomography, when using filtered back projection reconstruction. For conventional x-ray computed tomography, the use of statistical iterative reconstruction algorithms has successfully reduced artifacts and statistical issues. In this work, an iterative reconstruction method for grating based phase-contrast tomography is presented. The method avoids the intermediate retrieval of absorption, differential phase and dark field projections. It directly reconstructs tomographic cross sections from phase stepping projections by the use of a forward projecting imaging model and an appropriate likelihood function. The likelihood function is then maximized with an iterative algorithm. The presented method is tested with tomographic data obtained through a wave field simulation of grating based phase-contrast tomography. The reconstruction results are in agreement with the expectations and proof the validity of the concept.
△ Less
Submitted 30 July, 2013;
originally announced July 2013.