-
A Non-intrusive Approach for Physics-constrained Learning with Application to Fuel Cell Modeling
Authors:
Vishal Srivastava,
Valentin Sulzer,
Peyman Mohtat,
Jason B. Siegel,
Karthik Duraisamy
Abstract:
A data-driven model augmentation framework, referred to as Weakly-coupled Integrated Inference and Machine Learning (IIML), is presented to improve the predictive accuracy of physical models. In contrast to parameter calibration, this work seeks corrections to the structure of the model by a) inferring augmentation fields that are consistent with the underlying model, and b) transforming these fie…
▽ More
A data-driven model augmentation framework, referred to as Weakly-coupled Integrated Inference and Machine Learning (IIML), is presented to improve the predictive accuracy of physical models. In contrast to parameter calibration, this work seeks corrections to the structure of the model by a) inferring augmentation fields that are consistent with the underlying model, and b) transforming these fields into corrective model forms. The proposed approach couples the inference and learning steps in a weak sense via an alternating optimization approach. This coupling ensures that the augmentation fields remain learnable and maintain consistent functional relationships with local modeled quantities across the training dataset. An iterative solution procedure is presented in this paper, removing the need to embed the augmentation function during the inference process. This framework is used to infer an augmentation introduced within a Polymer electrolyte membrane fuel cell (PEMFC) model using a small amount of training data (from only 14 training cases.) These training cases belong to a dataset consisting of high-fidelity simulation data obtained from a high-fidelity model of a first generation Toyota Mirai. All cases in this dataset are characterized by different inflow and outflow conditions on the same geometry. When tested on 1224 different configurations, the inferred augmentation significantly improves the predictive accuracy for a wide range of physical conditions. Predictions and available data for the current density distribution are also compared to demonstrate the predictive capability of the model for quantities of interest which were not involved in the inference process. The results demonstrate that the weakly-coupled IIML framework offers sophisticated and robust model augmentation capabilities without requiring extensive changes to the numerical solver.
△ Less
Submitted 30 June, 2022;
originally announced July 2022.
-
Predicting the impact of formation protocols on battery lifetime immediately after manufacturing
Authors:
Andrew Weng,
Peyman Mohtat,
Peter M. Attia,
Valentin Sulzer,
Suhak Lee,
Greg Less,
Anna Stefanopoulou
Abstract:
Increasing the speed of battery formation can significantly lower lithium-ion battery manufacturing costs. However, adopting faster formation protocols in practical manufacturing settings is challenging due to a lack of inexpensive, rapid diagnostic signals that can inform possible impacts to long-term battery lifetime. This work identifies the cell resistance measured at low states of charge as a…
▽ More
Increasing the speed of battery formation can significantly lower lithium-ion battery manufacturing costs. However, adopting faster formation protocols in practical manufacturing settings is challenging due to a lack of inexpensive, rapid diagnostic signals that can inform possible impacts to long-term battery lifetime. This work identifies the cell resistance measured at low states of charge as an early-life diagnostic feature for screening new formation protocols. We show that this signal correlates to cycle life and improves the accuracy of data-driven battery lifetime prediction models. The signal is obtainable at the end of the manufacturing line, takes seconds to acquire, and does not require specialized test equipment. We explore a physical connection between this resistance signal and the quantity of lithium consumed during formation, suggesting that the signal may be broadly applicable for evaluating any manufacturing process change that could impact the total lithium consumed during formation.
△ Less
Submitted 26 March, 2022;
originally announced March 2022.
-
An Algorithmic Safety VEST For Li-ion Batteries During Fast Charging
Authors:
Peyman Mohtat,
Sravan Pannala,
Valentin Sulzer,
Jason B. Siegel,
Anna G. Stefanopoulou
Abstract:
Fast charging of lithium-ion batteries is crucial to increase desirability for consumers and hence accelerate the adoption of electric vehicles. A major barrier to shorter charge times is the accelerated aging of the battery at higher charging rates, which can be driven by lithium plating, increased solid electrolyte interphase growth due to elevated temperatures, and particle cracking due to mech…
▽ More
Fast charging of lithium-ion batteries is crucial to increase desirability for consumers and hence accelerate the adoption of electric vehicles. A major barrier to shorter charge times is the accelerated aging of the battery at higher charging rates, which can be driven by lithium plating, increased solid electrolyte interphase growth due to elevated temperatures, and particle cracking due to mechanical stress. Lithium plating depends on the overpotential of the negative electrode, and mechanical stress depends on the concentration gradient, both of which cannot be measured directly. Techniques based on physics-based models of the battery and optimal control algorithms have been developed to this end. While these methods show promise in reducing degradation, their optimization algorithms' complexity can limit their implementation. In this paper, we present a method based on the constant current constant voltage (CC-CV) charging scheme, called CC-CV$ησ$T (VEST). The new approach is simpler to implement and can be used with any model to impose varying levels of constraints on variables pertinent to degradation, such as plating potential and mechanical stress. We demonstrate the new CC-CV$ησ$T charging using an electrochemical model with mechanical and thermal effects included. Furthermore, we discuss how uncertainties can be accounted for by considering safety margins for the plating and stress constraints.
△ Less
Submitted 17 August, 2021;
originally announced August 2021.
-
Lite-Sparse Hierarchical Partial Power Processing for Second-Use Battery Energy Storage Systems
Authors:
Xiaofan Cui,
Alireza Ramyar,
Peyman Mohtat,
Veronica Contreras,
Jason Siegel,
Anna Stefanopoulou,
Al-Thaddeus Avestruz
Abstract:
The explosive growth of electric vehicles (EVs) is leading to a surge in retired EV batteries, which are typically recycled despite having nearly 80% available capacity. Repurposing automotive batteries for second-use battery energy storage systems (2-BESS) has both economical and environmental benefits. The challenge with second-use batteries is the heterogeneity in their state of health. This pa…
▽ More
The explosive growth of electric vehicles (EVs) is leading to a surge in retired EV batteries, which are typically recycled despite having nearly 80% available capacity. Repurposing automotive batteries for second-use battery energy storage systems (2-BESS) has both economical and environmental benefits. The challenge with second-use batteries is the heterogeneity in their state of health. This paper introduces a new strategy to optimize 2-BESS performance despite the heterogeneity of individual batteries while reducing the cost of power conversion. In this paper, the statistical distribution of the power heterogeneity in the supply of batteries is used to optimize the choice of power converters and design the power flow within the battery energy storage system (BESS) to optimize power capability. By leveraging a new lite-sparse hierarchical partial power processing (LS-HiPPP) approach, we study how a hierarchy in partial power processing (PPP) partitions power converters to significantly reduce converter ratings, process less power to achieve high system efficiency with lower cost (lower efficiency) converters, and take advantage of economies of scale by requiring only a minimal number of sets of identical converters. Our results demonstrate that LS-HiPPP architectures offer the best tradeoff between battery utilization and converter cost and have higher system efficiency than conventional partial power processing (C-PPP) in all cases.
△ Less
Submitted 9 September, 2022; v1 submitted 6 June, 2021;
originally announced June 2021.
-
Comparing Power Processing System Approaches in Second-Use Battery Energy Buffering for Electric Vehicle Charging
Authors:
Xiaofan Cui,
Alireza Ramyar,
Jason Siegel,
Peyman Mohtat,
Anna Stefanopoulou,
Al-Thaddeus Avestruz
Abstract:
The heterogeneity in pack voltages and capacity of aged packs limits the performance and economic viability of second-use battery energy storage systems (2-BESS) due to issues of reliability and available energy. Overcoming these limitations could enable extended use of batteries and improve the environmental impacts of electric vehicles by reducing the number of batteries produced. This paper com…
▽ More
The heterogeneity in pack voltages and capacity of aged packs limits the performance and economic viability of second-use battery energy storage systems (2-BESS) due to issues of reliability and available energy. Overcoming these limitations could enable extended use of batteries and improve the environmental impacts of electric vehicles by reducing the number of batteries produced. This paper compares Lite-Sparse Hierarchical Partial Power Processing (LS-HiPPP), a new method for power processing in 2-BESS, to conventional power processing architectures using a stochastic EV charging plaza model. This method for performance evaluation allows a fair comparison among power processing architectures for 2-BESS. Results show that LS-HiPPP increases the battery energy utilization to 94% as compared to 78% for conventional partial power processing (C-PPP) and 23% for full power processing. These results were obtained with 25% heterogeneity in individual battery capacities and 20% power processing within the 2-BESS. Derating and captured value are two derived performance metrics for comparing LS-HiPPP and C-PPP in this work. The derating for LS-HiPPP is 84.3% in comparison to 63.1% for C-PPP. The captured value for LS-HiPPP is 79.8% versus 51% for C-PPP.
△ Less
Submitted 24 February, 2022; v1 submitted 28 April, 2021;
originally announced April 2021.
-
Li-ion Battery Fault Detection in Large Packs Using Force and Gas Sensors
Authors:
Ting Cai,
Peyman Mohtat,
Anna G. Stefanopoulou,
Jason B. Siegel
Abstract:
Internal short circuits are a leading cause of battery thermal runaway, and hence a major safety issue for electric vehicles. An internal short circuit with low resistance is called a hard internal short, which causes a high internal current flow that leads to an extremely fast temperature rise, gas generation, cell swelling, and ultimately battery rupture and failure. Thus it is crucial to detect…
▽ More
Internal short circuits are a leading cause of battery thermal runaway, and hence a major safety issue for electric vehicles. An internal short circuit with low resistance is called a hard internal short, which causes a high internal current flow that leads to an extremely fast temperature rise, gas generation, cell swelling, and ultimately battery rupture and failure. Thus it is crucial to detect these faults immediately after they get triggered. In large battery packs with many cells in parallel, detecting an internal short circuit event using voltage is difficult due to suppression of the voltage signal from the faulty cell by the other healthy cells connected in parallel. In contrast, analyzing the gas composition in the pack enclosure can provide a robust single cell failure detection method. At elevated temperature, decomposition of the battery materials results in gas generation and cell swelling. The cell structure is designed to rupture at a critical gas pressure and vent the accumulated $CO_2$ gas, in order to prevent explosive forces. In this paper, we extend our previous work by combining the models of cell thermal dynamics, swelling, and $CO_2$ gas generation. In particular, we developed a fast and high confidence level detection method of hard internal short circuit events for a battery pack by measuring cell expansion force and monitoring $CO_2$ concentrations in a pack enclosure.
△ Less
Submitted 22 October, 2020;
originally announced October 2020.
-
Promise and Challenges of a Data-Driven Approach for Battery Lifetime Prognostics
Authors:
Valentin Sulzer,
Peyman Mohtat,
Suhak Lee,
Jason B. Siegel,
Anna G. Stefanopoulou
Abstract:
Recent data-driven approaches have shown great potential in early prediction of battery cycle life by utilizing features from the discharge voltage curve. However, these studies caution that data-driven approaches must be combined with specific design of experiments in order to limit the range of aging conditions, since the expected life of Li-ion batteries is a complex function of various aging f…
▽ More
Recent data-driven approaches have shown great potential in early prediction of battery cycle life by utilizing features from the discharge voltage curve. However, these studies caution that data-driven approaches must be combined with specific design of experiments in order to limit the range of aging conditions, since the expected life of Li-ion batteries is a complex function of various aging factors. In this work, we investigate the performance of the data-driven approach for battery lifetime prognostics with Li-ion batteries cycled under a variety of aging conditions, in order to determine when the data-driven approach can successfully be applied. Results show a correlation between the variance of the discharge capacity difference and the end-of-life for cells aged under a wide range of charge/discharge C-rates and operating temperatures. This holds despite the different conditions being used not only to cycle the batteries but also to obtain the features: the features are calculated directly from cycling data without separate slow characterization cycles at a controlled temperature. However, the correlation weakens considerably when the voltage data window for feature extraction is reduced, or when features from the charge voltage curve instead of discharge are used. As deep constant-current discharges rarely happen in practice, this imposes new challenges for applying this method in a real-world system.
△ Less
Submitted 14 October, 2020;
originally announced October 2020.
-
Improved Battery State Estimation Under Parameter Uncertainty Caused by Aging Using Expansion Measurements
Authors:
Sravan Pannala,
Puneet Valecha,
Peyman Mohtat,
Jason B. Siegel,
Anna G. Stefanopoulou
Abstract:
Accurate tracking of the internal electrochemical states of lithium-ion battery during cycling enables advanced battery management systems to operate the battery safely and maintain high performance while minimizing battery degradation. To this end, techniques based on voltage measurement have shown promise for estimating the lithium surface concentration of active material particles, which is an…
▽ More
Accurate tracking of the internal electrochemical states of lithium-ion battery during cycling enables advanced battery management systems to operate the battery safely and maintain high performance while minimizing battery degradation. To this end, techniques based on voltage measurement have shown promise for estimating the lithium surface concentration of active material particles, which is an important state for avoiding aging mechanisms such as lithium plating. However, methods relying on voltage often lead to large estimation errors when the model parameters change during aging. In this paper, we utilize the in-situ measurement of the battery expansion to augment the voltage and develop an observer to estimate the lithium surface concentration distribution in each electrode particle. We demonstrate that the addition of the expansion signal enables us to correct the negative electrode concentration states in addition to the positive electrode. As a result, compared to a voltage only observer, the proposed observer can successfully recover the surface concentration when the electrodes' stoichiometric window changes, which is a common occurrence under aging by loss of lithium inventory. With a 5% shift in the electrodes' stoichiometric window, the results indicate a reduction in state estimation error for the negative electrode surface concentration. Under this simulated aged condition, the voltage based observer had 9.3% error as compared to the proposed voltage and expansion observer which had 0.1% error in negative electrode surface concentration.
△ Less
Submitted 29 September, 2020;
originally announced September 2020.