Coulomb excitation of $^{68}$Ni at safe energies
Authors:
N. Bree,
I. Stefanescu,
P. A. Butler,
J. Cederkäll,
T. Davinson,
P. Delahaye,
J. Eberth,
D. Fedorov,
V. N. Fedosseev,
L. M. Fraile,
S. Franchoo,
G. Georgiev,
K. Gladnishki,
M. Huyse,
O. Ivanov,
J. Iwanicki,
J. Jolie,
U. Köster,
Th. Kröll,
R. Krücken,
B. A. Marsh,
O. Niedermaier,
P. Reiter,
H. Scheit,
D. Schwalm
, et al. (7 additional authors not shown)
Abstract:
The $B(E2;0^+\to2^+)$ value in $^{68}$Ni has been measured using Coulomb excitation at safe energies. The $^{68}$Ni radioactive beam was post-accelerated at the ISOLDE facility (CERN) to 2.9 MeV/u. The emitted $γ$ rays were detected by the MINIBALL detector array. A kinematic particle reconstruction was performed in order to increase the measured c.m. angular range of the excitation cross sectio…
▽ More
The $B(E2;0^+\to2^+)$ value in $^{68}$Ni has been measured using Coulomb excitation at safe energies. The $^{68}$Ni radioactive beam was post-accelerated at the ISOLDE facility (CERN) to 2.9 MeV/u. The emitted $γ$ rays were detected by the MINIBALL detector array. A kinematic particle reconstruction was performed in order to increase the measured c.m. angular range of the excitation cross section. The obtained value of 2.8$^{+1.2}_{-1.0}$ 10$^2$ e$^2$fm$^4$ is in good agreement with the value measured at intermediate energy Coulomb excitation, confirming the low $0^+\to2^+$ transition probability.
△ Less
Submitted 19 November, 2008; v1 submitted 5 March, 2008;
originally announced March 2008.
-
"Safe" Coulomb Excitation of 30Mg
Authors:
O. Niedermaier,
H. Scheit,
V. Bildstein,
H. Boie,
J. Fitting,
R. von Hahn,
F. K"ock,
M. Lauer,
U. K. Pal,
H. Podlech,
R. Repnow,
D. Schwalm
Abstract:
We report on the first radioactive beam experiment performed at the recently commissioned REX-ISOLDE facility at CERN in conjunction with the highly efficient gamma spectrometer MINIBALL. Using 30Mg ions accelerated to an energy of 2.25 MeV/u together with a thin nat-Ni target, Coulomb excitation of the first excited 2+ states of the projectile and target nuclei well below the Coulomb barrier wa…
▽ More
We report on the first radioactive beam experiment performed at the recently commissioned REX-ISOLDE facility at CERN in conjunction with the highly efficient gamma spectrometer MINIBALL. Using 30Mg ions accelerated to an energy of 2.25 MeV/u together with a thin nat-Ni target, Coulomb excitation of the first excited 2+ states of the projectile and target nuclei well below the Coulomb barrier was observed. From the measured relative de-excitation gamma ray yields the B(E2; 0+ -> 2+) value of 30Mg was determined to be 241(31) e2fm4. Our result is lower than values obtained at projectile fragmentation facilities using the intermediate-energy Coulomb excitation method, and confirms the theoretical conjecture that the neutron-rich magnesium isotope 30Mg lies still outside the ``island of inversion''.
△ Less
Submitted 17 December, 2004;
originally announced December 2004.
-
First Results on In-Beam gamma Spectroscopy of Neutron-Rich Na and Mg Isotopes at REX-ISOLDE
Authors:
H. Scheit,
O. Niedermaier,
M. Pantea,
F. Aksouh,
C. Alvarez,
F. Ames,
T. Behrens,
V. Bildstein,
H. Boie,
P. Butler,
J. Cederkall,
T. Davinson,
P. Delahaye,
P. Van Duppen,
J. Eberth,
S. Emhofer,
J. Fitting,
S. Franchoo,
R. Gernhaeuser,
G. Gersch,
D. Habs,
R. v. Hahn,
H. Hess,
A. Hurst,
M. Huyse
, et al. (24 additional authors not shown)
Abstract:
After the successful commissioning of the radioactive beam experiment at ISOLDE (REX-ISOLDE) - an accelerator for exotic nuclei produced by ISOLDE - first physics experiments using these beams were performed. Initial experiments focused on the region of deformation in the vicinity of the neutron-rich Na and Mg isotopes. Preliminary results show the high potential and physics opportunities offere…
▽ More
After the successful commissioning of the radioactive beam experiment at ISOLDE (REX-ISOLDE) - an accelerator for exotic nuclei produced by ISOLDE - first physics experiments using these beams were performed. Initial experiments focused on the region of deformation in the vicinity of the neutron-rich Na and Mg isotopes. Preliminary results show the high potential and physics opportunities offered by the exotic isotope accelerator REX in conjunction with the modern Germanium gamma spectrometer MINIBALL.
△ Less
Submitted 21 January, 2004;
originally announced January 2004.
-
The VLQ Calorimeter of H1 at HERA: A Highly Compact Device for Measurements of Electrons and Photons under Very Small Scattering Angles
Authors:
A. Stellberger,
K. Meier,
O. Niedermaier,
O. Nix,
K. Schmitt,
J. Stiewe,
M. Weber,
J. Ferencei,
F. Krivan,
J. Spalek
Abstract:
In 1998, the detector H1 at HERA has been equipped with a small backward spectrometer, the Very Low Q^2 (VLQ) spectrometer comprising a silicon tracker, a tungsten - scintillator sandwich calorimeter, and a Time-of-Flight system. The spectrometer was designed to measure electrons scattered under very low angles, equivalent to very low squared four - momentum transfers Q^2, and high energy photon…
▽ More
In 1998, the detector H1 at HERA has been equipped with a small backward spectrometer, the Very Low Q^2 (VLQ) spectrometer comprising a silicon tracker, a tungsten - scintillator sandwich calorimeter, and a Time-of-Flight system. The spectrometer was designed to measure electrons scattered under very low angles, equivalent to very low squared four - momentum transfers Q^2, and high energy photons with good energy and spatial resolution. The VLQ was in operation during the 1999 and 2000 run periods. This paper describes the design and construction of the VLQ calorimeter, a compact device with a fourfold projective energy read-out, and its performance during test runs and in the experiment.
△ Less
Submitted 16 May, 2003;
originally announced May 2003.