Quantized thermoelectric Hall plateau in the quantum limit of graphite as a nodal line semimetal
Authors:
Andhika Kiswandhi,
Tomotaka Ochi,
Toshihiro Taen,
Mitsuyuki Sato,
Kazuhito Uchida,
Toshihito Osada
Abstract:
We performed thermoelectric Hall conductivity $α_{xy}$ measurements on single-crystal graphite in the quantum limit up to 13 T. Both electrical and thermoelectric transport measurements were performed on the same crystal to extract pure $α_{xy}$, avoiding any sample quality dependence. The $α_{xy}$ converges to a plateau in the quantum limit with a linear dependence on temperature. This behavior i…
▽ More
We performed thermoelectric Hall conductivity $α_{xy}$ measurements on single-crystal graphite in the quantum limit up to 13 T. Both electrical and thermoelectric transport measurements were performed on the same crystal to extract pure $α_{xy}$, avoiding any sample quality dependence. The $α_{xy}$ converges to a plateau in the quantum limit with a linear dependence on temperature. This behavior is analogous to the quantized thermoelectric Hall effect (QTHE) observed in three-dimensional Dirac/Weyl nodal-point semimetals, and experimentally confirms a theoretical proposal on the QTHE in semimetals with nodal lines as in graphite.
△ Less
Submitted 5 May, 2023; v1 submitted 4 November, 2022;
originally announced November 2022.
-
Termination of Graphene Edges Created by Hydrogen and Deuterium Plasmas
Authors:
Taisuke Ochi,
Masahiro Kamada,
Takamoto Yokosawa,
Kozo Mukai,
Jun Yoshinobu,
Tomohiro Matsui
Abstract:
Edge engineering is important for both fundamental research and applications as the device size decreases to nanometer scale. This is especially the case for graphene because a graphene edge shows totally different electronic properties depending on the atomic structure and the termination. It has recently been shown that an atomically precise zigzag edge can be obtained by etching graphene and gr…
▽ More
Edge engineering is important for both fundamental research and applications as the device size decreases to nanometer scale. This is especially the case for graphene because a graphene edge shows totally different electronic properties depending on the atomic structure and the termination. It has recently been shown that an atomically precise zigzag edge can be obtained by etching graphene and graphite using hydrogen (H) plasma. However, edge termination had not been studied directly. In this study, termination of edges created by H-plasma is studied by high-resolution electron energy loss spectroscopy (HREELS) to show that the edge is $\mathrm{sp}^{2}$ bonded and the edge carbon atom is terminated by only one H atom. This suggests that an ideal zigzag edge, which is not only atomically precise but also $\mathrm{sp}^{2}$ bonding, can be obtained by H-plasma etching. Etching of the graphite surface with plasma of a different isotope, deuterium (D), is also studied by scanning tunneling microscopy (STM) to show that D-plasma anisotropically etches graphite less efficiently, although it can make defects more efficiently, than H-plasma.
△ Less
Submitted 12 December, 2022; v1 submitted 31 October, 2022;
originally announced October 2022.
-
Introducing Corrections to the Reflectance of Graphene by Light Emission
Authors:
Ken-ichi Sasaki,
Kenichi Hitachi,
Masahiro Kamada,
Takamoto Yokosawa,
Taisuke Ochi,
Tomohiro Matsui
Abstract:
Monolayer graphene absorbs 2.3 percent of the incident visible light. This 'small' absorption has been used to emphasize the visual transparency of graphene, but it in fact means that multilayer graphene absorbs a sizable fraction of incident light, which causes non-negligible fluorescence. In this paper, we formulate the light emission properties of multilayer graphene composed of tens to hundred…
▽ More
Monolayer graphene absorbs 2.3 percent of the incident visible light. This 'small' absorption has been used to emphasize the visual transparency of graphene, but it in fact means that multilayer graphene absorbs a sizable fraction of incident light, which causes non-negligible fluorescence. In this paper, we formulate the light emission properties of multilayer graphene composed of tens to hundreds of layers using a transfer matrix method and confirm the method's validity experimentally. We could quantitatively explain the measured contrasts of multilayer graphene on SiO$_2$/Si substrates and found sizable corrections, which cannot be classified as incoherent light emissions, to the reflectance of visible light. The new component originates from coherent emission caused by absorption at each graphene layer. Multilayer graphene thus functions as a partial coherent light source of various wavelengths, and it may have surface-emitting laser applications.
△ Less
Submitted 28 May, 2024; v1 submitted 2 August, 2022;
originally announced August 2022.
-
Nanoscale Fabrication of Graphene by Hydrogen-Plasma Etching
Authors:
Takamoto Yokosawa,
Masahiro Kamada,
Taisuke Ochi,
Yuki Koga,
Rin Takehara,
Masahiro Hara,
Tomohiro Matsui
Abstract:
Graphene is attracting vast interest due to its superior electronic and mechanical properties. However, structure and electronic properties of its edge are often neglected, although they are important for nanoscale devices because the edge ratio becomes larger by decreasing the device size. In this study, we suggest a way to fabricate a graphene with atomically aligned zigzag edges by applying hyd…
▽ More
Graphene is attracting vast interest due to its superior electronic and mechanical properties. However, structure and electronic properties of its edge are often neglected, although they are important for nanoscale devices because the edge ratio becomes larger by decreasing the device size. In this study, we suggest a way to fabricate a graphene with atomically aligned zigzag edges by applying hydrogen-plasma etching (HPE) technique. By patterning a graphene prior to HPE, it is succeeded to shape a graphene in desired structure. Both atomic force microscopy and Raman spectroscopy confirm that the graphene shaped by this technique preserves its honeycomb structure even on the edge, which is aligned with zigzag structure. Although the mechanism of the anisotropic etching by hydrogen-plasma have not been clarified yet, the sample position dependence of the etching rate suggests that the hydrogen-radicals are responsible for the anisotropic etching.
△ Less
Submitted 23 August, 2022; v1 submitted 9 March, 2022;
originally announced March 2022.
-
Thermoelectric Hall Effect at High-Magnetic-Field Quantum Limit in Graphite as a Nodal-Line Semimetal
Authors:
Toshihito Osada,
Tomotaka Ochi,
Toshihiro Taen
Abstract:
The high-magnetic-field thermoelectric effect in nodal-line semimetals with straight nodal lines was investigated. Three-dimensional (3D) Dirac/Weyl semimetals exhibit constant thermoelectric Hall conductivity at the high-magnetic-field quantum limit, resulting in a boundless linear increase of Seebeck coefficient. This is known as the quantized thermoelectric Hall effect (QTHE), and is expected t…
▽ More
The high-magnetic-field thermoelectric effect in nodal-line semimetals with straight nodal lines was investigated. Three-dimensional (3D) Dirac/Weyl semimetals exhibit constant thermoelectric Hall conductivity at the high-magnetic-field quantum limit, resulting in a boundless linear increase of Seebeck coefficient. This is known as the quantized thermoelectric Hall effect (QTHE), and is expected to lead to high-performance thermoelectricity at low temperatures. Here, in addition to Dirac/Weyl semimetals, we demonstrated that 3D semimetals with straight nodal lines can also exhibit the QTHE under high magnetic fields. As a candidate material for experimental validation, we discussed the thermoelectric properties of bulk graphite. Furthermore, we investigated the dimensional crossover of thermoelectricity to two-dimensional behavior in thin-film graphite.
△ Less
Submitted 22 February, 2022;
originally announced February 2022.
-
Cryogenic suspension design for a kilometer-scale gravitational-wave detector
Authors:
Takafumi Ushiba,
Tomotada Akutsu,
Yoichi Aso,
Sakae Araki,
Rishabh Bajpai,
Dan Chen,
Kieran Craig,
William Creus,
Yutaro Enomoto,
Yoshinori Fujii,
Masashi Fukunaga,
Ayako Hagiwara,
Sadakazu Haino,
Kunihiko Hasegawa,
Yuki Inoue,
Kiwamu Izumi,
Nobuhiro Kimura,
Keiko Kokeyama,
Rahul Kumar,
Ettore Majorana,
Yuta Michimura,
Takahiro Miyamoto,
Shinji Miyoki,
Iwao Murakami,
Yoshikazu Namai
, et al. (21 additional authors not shown)
Abstract:
We report the mirror suspension design for Large-scale Cryogenic Gravitational wave Telescope, KAGRA, during bKAGRA Phase 1. Mirror thermal noise is one of the fundamental noises for room-temperature gravitational-wave detectors such as Advanced LIGO and Advanced Virgo. Thus, reduction of thermal noise is required for further improvement of their sensitivity. One effective approach for reducing th…
▽ More
We report the mirror suspension design for Large-scale Cryogenic Gravitational wave Telescope, KAGRA, during bKAGRA Phase 1. Mirror thermal noise is one of the fundamental noises for room-temperature gravitational-wave detectors such as Advanced LIGO and Advanced Virgo. Thus, reduction of thermal noise is required for further improvement of their sensitivity. One effective approach for reducing thermal noise is to cool the mirrors. There are many technical challenges that must be overcome to cool the mirrors, such as cryocooler induced vibrations, thermal drift in suspensions, and reduction in duty cycling due to the increased number of potential failure mechanisms. Our mirror suspension has a black coating that makes radiative cooling more efficient. For conduction cooling, we developed ultra high purity aluminum heat links, which yield high thermal conductivity while keeping the spring constant sufficiently small. A unique inclination adjustment system, called moving mass, is used for aligning the mirror orientation in pitch. Photo-reflective displacement sensors, which have a large range, are installed for damping control on marionette recoil mass and intermediate recoil mass. Samarium cobalt magnets are used for coil-magnet actuators to prevent significant change of magnetism between room temperature and cryogenic temperature. In this paper, the design of our first cryogenic payload and its performance during bKAGRA Phase 1 are discussed.
△ Less
Submitted 25 January, 2021; v1 submitted 5 October, 2020;
originally announced October 2020.
-
Application of the independent component analysis to the iKAGRA data
Authors:
KAGRA Collaboration,
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
Y. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
E. Capocasa,
M. Chan,
C. Chen,
K. Chen,
Y. Chen,
H. Chu,
Y-K. Chu
, et al. (227 additional authors not shown)
Abstract:
We apply the independent component analysis (ICA) to the real data from a gravitational wave detector for the first time. Specifically we use the iKAGRA data taken in April 2016, and calculate the correlations between the gravitational wave strain channel and 35 physical environmental channels. Using a couple of seismic channels which are found to be strongly correlated with the strain, we perform…
▽ More
We apply the independent component analysis (ICA) to the real data from a gravitational wave detector for the first time. Specifically we use the iKAGRA data taken in April 2016, and calculate the correlations between the gravitational wave strain channel and 35 physical environmental channels. Using a couple of seismic channels which are found to be strongly correlated with the strain, we perform ICA. Injecting a sinusoidal continuous signal in the strain channel, we find that ICA recovers correct parameters with enhanced signal-to-noise ratio, which demonstrates usefulness of this method. Among the two implementations of ICA used here, we find the correlation method yields the optimal result for the case environmental noises act on the strain channel linearly.
△ Less
Submitted 1 June, 2020; v1 submitted 8 August, 2019;
originally announced August 2019.
-
First cryogenic test operation of underground km-scale gravitational-wave observatory KAGRA
Authors:
KAGRA Collaboration,
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
W. Creus,
K. Doi,
K. Eda
, et al. (179 additional authors not shown)
Abstract:
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic…
▽ More
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic motion at low frequencies and high stability of the detector. Another advantage is that it cools down the sapphire test mass mirrors to cryogenic temperatures to reduce thermal noise. In April-May 2018, we have operated a 3-km Michelson interferometer with a cryogenic test mass for 10 days, which was the first time that km-scale interferometer was operated at cryogenic temperatures. In this article, we report the results of this "bKAGRA Phase 1" operation. We have demonstrated the feasibility of 3-km interferometer alignment and control with cryogenic mirrors.
△ Less
Submitted 11 January, 2019;
originally announced January 2019.
-
KAGRA: 2.5 Generation Interferometric Gravitational Wave Detector
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
W. Creus,
K. Doi,
K. Eda,
Y. Enomoto
, et al. (169 additional authors not shown)
Abstract:
The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Tel…
▽ More
The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Telescope), a new GW detector with two 3-km baseline arms arranged in the shape of an "L", located inside the Mt. Ikenoyama, Kamioka, Gifu, Japan. KAGRA's design is similar to those of the second generations such as Advanced LIGO/Virgo, but it will be operating at the cryogenic temperature with sapphire mirrors. This low temperature feature is advantageous for improving the sensitivity around 100 Hz and is considered as an important feature for the third generation GW detector concept (e.g. Einstein Telescope of Europe or Cosmic Explorer of USA). Hence, KAGRA is often called as a 2.5 generation GW detector based on laser interferometry. The installation and commissioning of KAGRA is underway and its cryogenic systems have been successfully tested in May, 2018. KAGRA's first observation run is scheduled in late 2019, aiming to join the third observation run (O3) of the advanced LIGO/Virgo network. In this work, we describe a brief history of KAGRA and highlights of main feature. We also discuss the prospects of GW observation with KAGRA in the era of O3. When operating along with the existing GW detectors, KAGRA will be helpful to locate a GW source more accurately and to determine the source parameters with higher precision, providing information for follow-up observations of a GW trigger candidate.
△ Less
Submitted 20 November, 2018;
originally announced November 2018.
-
The status of KAGRA underground cryogenic gravitational wave telescope
Authors:
KAGRA Collaboration,
T. Akutsu,
M. Ando,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
M. A. Barton,
K. Cannon,
K. Craig,
W. Creus,
K. Doi,
K. Eda,
Y. Enomoto,
R. Flaminio,
Y. Fujii,
M. -K. Fujimoto,
T. Furuhata,
S. Haino,
K. Hasegawa,
K. Hashino,
K. Hayama,
S. Hirobayashi
, et al. (126 additional authors not shown)
Abstract:
KAGRA is a 3-km interferometric gravitational wave telescope located in the Kamioka mine in Japan. It is the first km-class gravitational wave telescope constructed underground to reduce seismic noise, and the first km-class telescope to use cryogenic cooling of test masses to reduce thermal noise. The construction of the infrastructure to house the interferometer in the tunnel, and the initial ph…
▽ More
KAGRA is a 3-km interferometric gravitational wave telescope located in the Kamioka mine in Japan. It is the first km-class gravitational wave telescope constructed underground to reduce seismic noise, and the first km-class telescope to use cryogenic cooling of test masses to reduce thermal noise. The construction of the infrastructure to house the interferometer in the tunnel, and the initial phase operation of the interferometer with a simple 3-km Michelson configuration have been completed. The first cryogenic operation is expected in 2018, and the observing runs with a full interferometer are expected in 2020s. The basic interferometer configuration and the current status of KAGRA are described.
△ Less
Submitted 13 October, 2017;
originally announced October 2017.
-
Maintenance-free Operation of WDM Quantum Key Distribution System through a Field Fiber over 30 Days
Authors:
Ken-ichiro Yoshino,
Takao Ochi,
Mikio Fujiwara,
Masahide Sasaki,
Akio Tajima
Abstract:
Maintenance-free wavelength-division-multiplexing quantum key distribution for 30 days was achieved through a 22-km field fiber. Using polarization-independent interferometers and stabilization techniques, we attained a quantum bit error rate as low as 1.70% and a key rate as high as 229.8 kbps, making the record of total secure key of 595.6 Gbits accumulated over an uninterrupted operation period…
▽ More
Maintenance-free wavelength-division-multiplexing quantum key distribution for 30 days was achieved through a 22-km field fiber. Using polarization-independent interferometers and stabilization techniques, we attained a quantum bit error rate as low as 1.70% and a key rate as high as 229.8 kbps, making the record of total secure key of 595.6 Gbits accumulated over an uninterrupted operation period.
△ Less
Submitted 5 August, 2013;
originally announced August 2013.