-
Non-negative solutions of a sublinear elliptic problem
Authors:
Julián López-Gómez,
Paul H. Rabinowitz,
Fabio Zanolin
Abstract:
In this paper the existence of solutions, $(λ,u)$, of the problem $$-Δu=λu -a(x)|u|^{p-1}u \quad \hbox{in }Ω, \qquad
u=0 \quad \hbox{on}\;\;\partialΩ,$$ is explored for $0 < p < 1$. When $p>1$, it is known that there is an unbounded component of such solutions bifurcating from $(σ_1, 0)$, where $σ_1$ is the smallest eigenvalue of $-Δ$ in $Ω$ under Dirichlet boundary conditions on $\partialΩ$. Th…
▽ More
In this paper the existence of solutions, $(λ,u)$, of the problem $$-Δu=λu -a(x)|u|^{p-1}u \quad \hbox{in }Ω, \qquad
u=0 \quad \hbox{on}\;\;\partialΩ,$$ is explored for $0 < p < 1$. When $p>1$, it is known that there is an unbounded component of such solutions bifurcating from $(σ_1, 0)$, where $σ_1$ is the smallest eigenvalue of $-Δ$ in $Ω$ under Dirichlet boundary conditions on $\partialΩ$. These solutions have $u \in P$, the interior of the positive cone. The continuation argument used when $p>1$ to keep $u \in P$ fails if $0 < p < 1$. Nevertheless when $0 < p < 1$, we are still able to show that there is a component of solutions bifurcating from $(σ_1, \infty)$, unbounded outside of a neighborhood of $(σ_1, \infty)$, and having $u \gneq 0$. This non-negativity for $u$ cannot be improved as is shown via a detailed analysis of the simplest autonomous one-dimensional version of the problem: its set of non-negative solutions possesses a countable set of components, each of them consisting of positive solutions with a fixed (arbitrary) number of bumps. Finally, the structure of these components is fully described.
△ Less
Submitted 7 March, 2024;
originally announced March 2024.
-
Detection of X-ray Polarization from the Blazar 1ES 1959+650 with the Imaging X-ray Polarimetry Explorer
Authors:
Manel Errando,
Ioannis Liodakis,
Alan P. Marscher,
Herman L. Marshall,
Riccardo Middei,
Michela Negro,
Abel Lawrence Peirson,
Matteo Perri,
Simonetta Puccetti,
Pazit L. Rabinowitz,
Iván Agudo,
Svetlana G. Jorstad,
Sergey S. Savchenko,
Dmitry Blinov,
Ioakeim G. Bourbah,
Sebastian Kiehlmann,
Evangelos Kontopodis,
Nikos Mandarakas,
Stylianos Romanopoulos,
Raphael Skalidis,
Anna Vervelaki,
Francisco José Aceituno,
Maria I. Bernardos,
Giacomo Bonnoli,
Víctor Casanova
, et al. (121 additional authors not shown)
Abstract:
Observations of linear polarization in the 2-8 keV energy range with the Imaging X-ray Polarimetry Explorer (IXPE) explore the magnetic field geometry and dynamics of the regions generating non-thermal radiation in relativistic jets of blazars. These jets, particularly in blazars whose spectral energy distribution peaks at X-ray energies, emit X-rays via synchrotron radiation from high-energy part…
▽ More
Observations of linear polarization in the 2-8 keV energy range with the Imaging X-ray Polarimetry Explorer (IXPE) explore the magnetic field geometry and dynamics of the regions generating non-thermal radiation in relativistic jets of blazars. These jets, particularly in blazars whose spectral energy distribution peaks at X-ray energies, emit X-rays via synchrotron radiation from high-energy particles within the jet. IXPE observations of the X-ray selected BL Lac-type blazar 1ES 1959+650 in 2022 May 3-4 showed a significant linear polarization degree of $Π_\mathrm{x} = 8.0\% \pm 2.3\%$ at an electric-vector position angle $ψ_\mathrm{x} = 123^\circ \pm 8^\circ$. However, in 2022 June 9-12, only an upper limit of $Π_\mathrm{x} \leq 5.1\%$ could be derived (at the 99% confidence level). The degree of optical polarization at that time $Π_\mathrm{O} \sim 5\%$ is comparable to the X-ray measurement. We investigate possible scenarios for these findings, including temporal and geometrical depolarization effects. Unlike some other X-ray selected BL Lac objects, there is no significant chromatic dependence of the measured polarization in 1ES 1959+650, and its low X-ray polarization may be attributed to turbulence in the jet flow with dynamical timescales shorter than 1 day.
△ Less
Submitted 9 January, 2024;
originally announced January 2024.
-
An Angular Diameter Measurement of $β$ UMa via Stellar Intensity Interferometry with the VERITAS Observatory
Authors:
A. Acharyya,
J. P. Aufdenberg,
P. Bangale,
J. T. Bartkoske,
P. Batista,
W. Benbow,
A. J. Chromey,
J. D. Davis,
Q. Feng,
G. M. Foote,
A. Furniss,
W. Hanlon,
C. E. Hinrichs,
J. Holder,
W. Jin,
P. Kaaret,
M. Kertzman,
D. Kieda,
T. K. Kleiner,
N. Korzoun,
T. LeBohec,
M. A. Lisa,
M. Lundy,
N. Matthews,
C. E McGrath
, et al. (22 additional authors not shown)
Abstract:
We use the VERITAS imaging air Cherenkov Telescope (IACT) array to obtain the first measured angular diameter of $β$ UMa at visual wavelengths using stellar intensity interferometry (SII) and independently constrain the limb-darkened angular diameter. The age of the Ursa Major moving group has been assessed from the ages of its members, including nuclear member Merak ($β$ UMa), an A1-type subgiant…
▽ More
We use the VERITAS imaging air Cherenkov Telescope (IACT) array to obtain the first measured angular diameter of $β$ UMa at visual wavelengths using stellar intensity interferometry (SII) and independently constrain the limb-darkened angular diameter. The age of the Ursa Major moving group has been assessed from the ages of its members, including nuclear member Merak ($β$ UMa), an A1-type subgiant, by comparing effective temperature and luminosity constraints to model stellar evolution tracks. Previous interferometric limb-darkened angular-diameter measurements of $β$ UMa in the near-infrared (CHARA Array, $1.149 \pm 0.014$ mas) and mid-infrared (Keck Nuller, $1.08 \pm 0.07$ mas), together with the measured parallax and bolometric flux, have constrained the effective temperature. This paper presents current VERITAS-SII observation and analysis procedures to derive squared visibilities from correlation functions. We fit the resulting squared visibilities to find a limb-darkened angular diameter of $1.07 \pm 0.04 {\rm (stat)} \pm 0.05$ (sys) mas, using synthetic visibilities from a stellar atmosphere model that provides a good match to the spectrum of $β$ UMa in the optical wave band. The VERITAS-SII limb-darkened angular diameter yields an effective temperature of $9700\pm200\pm 200$ K, consistent with ultraviolet spectrophotometry, and an age of $390\pm 29 \pm 32 $ Myr, using MESA Isochrones and Stellar Tracks (MIST). This age is consistent with $408 \pm 6$ Myr from the CHARA Array angular diameter.
△ Less
Submitted 3 January, 2024;
originally announced January 2024.
-
VERITAS contributions to the 38th International Cosmic Ray Conference
Authors:
A. Acharyya,
C. B. Adams,
A. Archer,
P. Bangale,
J. T. Bartkoske,
P. Batista,
W. Benbow,
J. L. Christiansen,
A. J. Chromey,
A. Duerr,
M. Errando,
Q. Feng,
G. M. Foote,
L. Fortson,
A. Furniss,
W. Hanlon,
O. Hervet,
C. E. Hinrichs,
J. Hoang,
J. Holder,
Z. Hughes,
T. B. Humensky,
W. Jin,
M. N. Johnson,
M. Kertzman
, et al. (39 additional authors not shown)
Abstract:
Compilation of papers presented by the VERITAS Collaboration at the 38th International Cosmic Ray Conference (ICRC), held July 26 through August 3, 2023 in Nagoya, Japan.
Compilation of papers presented by the VERITAS Collaboration at the 38th International Cosmic Ray Conference (ICRC), held July 26 through August 3, 2023 in Nagoya, Japan.
△ Less
Submitted 12 December, 2023;
originally announced December 2023.
-
The proton radius puzzle
Authors:
J. J. Krauth,
K. Schuhmann,
M. Abdou Ahmed,
F. D. Amaro,
P. Amaro,
F. Biraben,
J. M. R. Cardoso,
M. L. Carvalho,
D. S. Covita,
A. Dax,
S. Dhawan,
M. Diepold,
L. M. P. Fernandes,
B. Franke,
S. Galtier,
A. Giesen,
A. L. Gouvea,
J. Götzfried,
T. Graf,
M. Guerra,
J. Haack,
T. W. Hänsch,
M. Hildebrandt,
P. Indelicato,
L. Julien
, et al. (27 additional authors not shown)
Abstract:
High-precision measurements of the proton radius from laser spectroscopy of muonic hydrogen demonstrated up to six standard deviations smaller values than obtained from electron-proton scattering and hydrogen spectroscopy. The status of this discrepancy, which is known as the proton radius puzzle will be discussed in this paper, complemented with the new insights obtained from spectroscopy of muon…
▽ More
High-precision measurements of the proton radius from laser spectroscopy of muonic hydrogen demonstrated up to six standard deviations smaller values than obtained from electron-proton scattering and hydrogen spectroscopy. The status of this discrepancy, which is known as the proton radius puzzle will be discussed in this paper, complemented with the new insights obtained from spectroscopy of muonic deuterium.
△ Less
Submitted 19 August, 2017; v1 submitted 2 June, 2017;
originally announced June 2017.
-
Laser Spectroscopy of Muonic Atoms and Ions
Authors:
Randolf Pohl,
François Nez,
Luis M. P. Fernandes,
Marwan Abdou Ahmed,
Fernando D. Amaro,
Pedro Amaro,
François Biraben,
João M. R. Cardoso,
Daniel S. Covita,
Andreas Dax,
Satish Dhawan,
Marc Diepold,
Beatrice Franke,
Sandrine Galtier,
Adolf Giesen,
Andrea L. Gouvea,
Johannes Götzfried,
Thomas Graf,
Theodor W. Hänsch,
Malte Hildebrandt,
Paul Indelicato,
Lucile Julien,
Klaus Kirch,
Andreas Knecht,
Paul Knowles
, et al. (22 additional authors not shown)
Abstract:
Laser spectroscopy of the Lamb shift (2S-2P energy difference) in light muonic atoms or ions, in which one negative muon $μ^-$ is bound to a nucleus, has been performed. The measurements yield significantly improved values of the root-mean-square charge radii of the nuclei, owing to the large muon mass, which results in a vastly increased muon wave function overlap with the nucleus. The values of…
▽ More
Laser spectroscopy of the Lamb shift (2S-2P energy difference) in light muonic atoms or ions, in which one negative muon $μ^-$ is bound to a nucleus, has been performed. The measurements yield significantly improved values of the root-mean-square charge radii of the nuclei, owing to the large muon mass, which results in a vastly increased muon wave function overlap with the nucleus. The values of the proton and deuteron radii are 10 and 3 times more accurate than the respective CODATA values, but 7 standard deviations smaller. Data on muonic helium-3 and -4 ions is being analyzed and will give new insights. In future, the (magnetic) Zemach radii of the proton and the helium-3 nuclei will be determined from laser spectroscopy of the 1S hyperfine splittings, and the Lamb shifts of muonic Li, Be and B can be used to improve the respective charge radii.
△ Less
Submitted 12 September, 2016;
originally announced September 2016.
-
Lifetime and population of the 2S state in muonic protium and deuterium
Authors:
Marc Diepold,
Fernando D. Amaro,
Aldo Antognini,
François Biraben,
João M. R. Cardoso,
Daniel S. Covita,
Andreas Dax,
Satish Dhawan,
Luis M. P. Fernandes,
Adolf Giesen,
Andrea L. Gouvea,
Thomas Graf,
Theodor W. Hänsch,
Paul Indelicato,
Lucile Julien,
Cheng-Yang Kao,
Paul Knowles,
Franz Kottmann,
Eric-Olivier Le Bigot,
Yi-Wei Liu,
José A. M. Lopes,
Livia Ludhova,
Cristina M. B. Monteiro,
Françoise Mulhauser,
Tobias Nebel
, et al. (10 additional authors not shown)
Abstract:
Radiative deexcitation (RD) of the metastable 2S state of muonic protium and deuterium atoms has been observed. In muonic protium, we improve the precision on lifetime and population (formation probability) values for the short-lived μp(2S) component, and give an upper limit for RD of long-lived μp(2S) atoms. In muonic deuterium at 1 hPa, 3.1 +-0.3 % of all stopped muons form μd(2S) atoms. The sho…
▽ More
Radiative deexcitation (RD) of the metastable 2S state of muonic protium and deuterium atoms has been observed. In muonic protium, we improve the precision on lifetime and population (formation probability) values for the short-lived μp(2S) component, and give an upper limit for RD of long-lived μp(2S) atoms. In muonic deuterium at 1 hPa, 3.1 +-0.3 % of all stopped muons form μd(2S) atoms. The short-lived 2S component has a population of 1.35 +0.57 -0.33 % and a lifetime of τ_short(μd) = 138 +32 -34 ns. We see evidence for RD of long-lived μd(2S) with a lifetime of τ_long(μd) = 1.15 +0.75 -0.53 μs. This is interpreted as formation and decay of excited muonic molecules.
△ Less
Submitted 10 October, 2013; v1 submitted 25 July, 2013;
originally announced July 2013.
-
Muonic hydrogen cascade time and lifetime of the short-lived $2S$ state
Authors:
L. Ludhova,
F. D. Amaro,
A. Antognini,
F. Biraben,
J. M. R. Cardoso,
C. A. N. Conde,
A. Dax,
S. Dhawan,
L. M. P. Fernandes,
T. W. Haensch,
V. W. Hughes,
P. Indelicato,
L. Julien,
P. E. Knowles,
F. Kottmann,
Y. -W. Liu,
J. A. M. Lopes,
C. M. B. Monteiro,
F. Mulhauser,
F. Nez,
R. Pohl,
P. Rabinowitz,
J. M. F. dos Santos,
L. A. Schaller,
C. Schwob
, et al. (2 additional authors not shown)
Abstract:
Metastable ${2S}$ muonic-hydrogen atoms undergo collisional ${2S}$-quenching, with rates which depend strongly on whether the $μp$ kinetic energy is above or below the ${2S}\to {2P}$ energy threshold. Above threshold, collisional ${2S} \to {2P}$ excitation followed by fast radiative ${2P} \to {1S}$ deexcitation is allowed. The corresponding short-lived $μp ({2S})$ component was measured at 0.6 h…
▽ More
Metastable ${2S}$ muonic-hydrogen atoms undergo collisional ${2S}$-quenching, with rates which depend strongly on whether the $μp$ kinetic energy is above or below the ${2S}\to {2P}$ energy threshold. Above threshold, collisional ${2S} \to {2P}$ excitation followed by fast radiative ${2P} \to {1S}$ deexcitation is allowed. The corresponding short-lived $μp ({2S})$ component was measured at 0.6 hPa $\mathrm{H}_2$ room temperature gas pressure, with lifetime $τ_{2S}^\mathrm{short} = 165 ^{+38}_{-29}$ ns (i.e., $λ_{2S}^\mathrm{quench} = 7.9 ^{+1.8}_{-1.6} \times 10^{12} \mathrm{s}^{-1}$ at liquid-hydrogen density) and population $ε_{2S}^\mathrm{short} = 1.70^{+0.80}_{-0.56}$ % (per $μp$ atom). In addition, a value of the $μp$ cascade time, $T_\mathrm{cas}^{μp} = (37\pm5)$ ns, was found.
△ Less
Submitted 13 November, 2006;
originally announced November 2006.
-
Planar LAAPDs: Temperature Dependence, Performance, and Application in Low Energy X-ray Spectroscopy
Authors:
L. Ludhova,
F. D. Amaro,
A. Antognini,
F. Biraben,
J. M. R. Cardoso,
C. A. N. Conde,
D. S. Covita,
A. Dax,
S. Dhawan,
L. M. P. Fernandes,
T. W. Hansch,
V. W. Hughes,
O. Huot,
P. Indelicato,
L. Julien,
P. E. Knowles,
F. Kottmann,
J. A. M. Lopes,
Y. -W. Liu,
C. M. B. Monteiro,
F. Mulhauser,
F. Nez,
R. Pohl,
P. Rabinowitz,
J. M. F. dos Santos
, et al. (3 additional authors not shown)
Abstract:
An experiment measuring the 2S Lamb shift in muonic hydrogen mup is being performed at the Paul Scherrer Institute, Switzerland. It requires small and compact detectors for 1.9 keV x rays (2P-1S transition) with an energy resolution around 25% at 2 keV, a time resolution better than 100 ns, a large solid angle coverage, and insensitivity to a 5 T magnetic field. We have chosen Large Area Avalanc…
▽ More
An experiment measuring the 2S Lamb shift in muonic hydrogen mup is being performed at the Paul Scherrer Institute, Switzerland. It requires small and compact detectors for 1.9 keV x rays (2P-1S transition) with an energy resolution around 25% at 2 keV, a time resolution better than 100 ns, a large solid angle coverage, and insensitivity to a 5 T magnetic field. We have chosen Large Area Avalanche Photodiodes (LAAPDs) from Radiation Monitoring Devices as x-ray detectors, and they were used during the last data taking period in 2003. For x-ray spectroscopy applications, these LAAPDs have to be cooled in order to suppress the dark current noise, hence, a series of tests were performed to choose the optimal operation temperature. Specifically, the temperature dependence of gain, energy resolution, dark current, excess noise factor, and detector response linearity was studied. Finally, details of the LAAPDs application in the muonic hydrogen experiment as well as their response to alpha particles are presented.
△ Less
Submitted 15 October, 2004;
originally announced October 2004.