-
Physics of Laser-Wakefield Accelerators (LWFA)
Authors:
Johannes Wenz,
Stefan Karsch
Abstract:
Intense ultrashort laser pulses propagating through an underdense plasma are able to drive relativistic plasma waves, creating accelerating structures with extreme gradients. These structures represent a new type of compact sources for generating ultrarelativistic, ultrashort electron beams. This chapter covers the theoretical background behind the process of LWFA. Starting from the basic descript…
▽ More
Intense ultrashort laser pulses propagating through an underdense plasma are able to drive relativistic plasma waves, creating accelerating structures with extreme gradients. These structures represent a new type of compact sources for generating ultrarelativistic, ultrashort electron beams. This chapter covers the theoretical background behind the process of LWFA. Starting from the basic description of electromagnetic waves and their interaction with particles, the main aspects of the LWFA are presented. These include the excitation of plasma waves, description of the acceleration phase and injection mechanisms. These considerations are concluded by a discussion of the fundamental limits on the energy gain and scaling laws.
△ Less
Submitted 9 July, 2020;
originally announced July 2020.
-
Dual-energy electron beams from a compact laser-driven accelerator
Authors:
J. Wenz,
K. Khrennikov,
A. Döpp,
M. Gilljohann,
H. Ding,
J. Goetzfried,
S. Schindler,
A. Buck,
J. Xu,
M. Heigoldt,
W. Helml,
L. Veisz,
S. Karsch
Abstract:
Ultrafast pump-probe experiments open the possibility to track fundamental material behaviour like changes in its electronic configuration in real time. To date, most of these experiments are performed using an electron or a high-energy photon beam, which is synchronized to an infrared laser pulse. Entirely new opportunities can be explored if not only a single, but multiple synchronized, ultra-sh…
▽ More
Ultrafast pump-probe experiments open the possibility to track fundamental material behaviour like changes in its electronic configuration in real time. To date, most of these experiments are performed using an electron or a high-energy photon beam, which is synchronized to an infrared laser pulse. Entirely new opportunities can be explored if not only a single, but multiple synchronized, ultra-short, high-energy beams are used. However, this requires advanced radiation sources that are capable of producing dual-energy electron beams, for example. Here, we demonstrate simultaneous generation of twin-electron beams from a single compact laser wakefield accelerator. The energy of each beam can be individually adjusted over a wide range and our analysis shows that the bunch lengths and their delay inherently amount to femtoseconds. Our proof-of-concept results demonstrate an elegant way to perform multi-beam experiments in future on a laboratory scale.
△ Less
Submitted 4 March, 2020; v1 submitted 16 April, 2018;
originally announced April 2018.
-
Research towards high-repetition rate laser-driven X-ray sources for imaging applications
Authors:
J. Götzfried,
A. Döpp,
M. Gilljohann,
H. Ding,
S. Schindler,
J. Wenz,
L. Hehn,
F. Pfeiffer,
S. Karsch
Abstract:
Laser wakefield acceleration of electrons represents a basis for several types of novel X-ray sources based on Thomson scattering or betatron radiation. The latter provides a high photon flux and a small source size, both being prerequisites for high-quality X-ray imaging. Furthermore, proof-of-principle experiments have demonstrated its application for tomographic imaging. So far this required se…
▽ More
Laser wakefield acceleration of electrons represents a basis for several types of novel X-ray sources based on Thomson scattering or betatron radiation. The latter provides a high photon flux and a small source size, both being prerequisites for high-quality X-ray imaging. Furthermore, proof-of-principle experiments have demonstrated its application for tomographic imaging. So far this required several hours of acquisition time for a complete tomographic data set. Based on improvements to the laser system, detectors and reconstruction algorithms, we were able to reduce this time for a full tomographic scan to 3 minutes. In this paper, we discuss these results and give a prospect to future imaging systems.
△ Less
Submitted 14 March, 2018;
originally announced March 2018.
-
Quick X-ray microtomography using a laser-driven betatron source
Authors:
A. Döpp,
L. Hehn,
J. Goetzfried,
J. Wenz,
M. Gilljohann,
H. Ding,
S. Schindler,
F. Pfeiffer,
S. Karsch
Abstract:
Laser-driven X-ray sources are an emerging alternative to conventional X-ray tubes and synchrotron sources. We present results on microtomographic X-ray imaging of a cancellous human bone sample using synchrotron-like betatron radiation. The source is driven by a 100-TW-class titanium-sapphire laser system and delivers over $10^8$ X-ray photons per second. Compared to earlier studies, the acquisit…
▽ More
Laser-driven X-ray sources are an emerging alternative to conventional X-ray tubes and synchrotron sources. We present results on microtomographic X-ray imaging of a cancellous human bone sample using synchrotron-like betatron radiation. The source is driven by a 100-TW-class titanium-sapphire laser system and delivers over $10^8$ X-ray photons per second. Compared to earlier studies, the acquisition time for an entire tomographic dataset has been reduced by more than an order of magnitude. Additionally, the reconstruction quality benefits from the use of statistical iterative reconstruction techniques. Depending on the desired resolution, tomographies are thereby acquired within minutes, which is an important milestone towards real-life applications of laser-plasma X-ray sources.
△ Less
Submitted 23 December, 2017;
originally announced December 2017.
-
Quantitative X-Ray Phase-Contrast Microtomography from a Compact Laser Driven Betatron Source
Authors:
J. Wenz,
S. Schleede,
K. Khrennikov,
M. Bech,
P. Thibault,
M. Heigoldt,
F. Pfeiffer,
S. Karsch
Abstract:
X-ray phase-contrast imaging has recently led to a revolution in resolving power and tissue contrast in biomedical imaging, microscopy and materials science. The necessary high spatial coherence is currently provided by either large-scale synchrotron facilities with limited beamtime access or by microfocus X-ray tubes with rather limited flux. X-rays radiated by relativistic electrons driven by we…
▽ More
X-ray phase-contrast imaging has recently led to a revolution in resolving power and tissue contrast in biomedical imaging, microscopy and materials science. The necessary high spatial coherence is currently provided by either large-scale synchrotron facilities with limited beamtime access or by microfocus X-ray tubes with rather limited flux. X-rays radiated by relativistic electrons driven by well-controlled high-power lasers offer a promising route to a proliferation of this powerful imaging technology. A laser-driven plasma wave accelerates and wiggles electrons, giving rise to brilliant keV X-ray emission. This so-called Betatron radiation is emitted in a collimated beam with excellent spatial coherence and remarkable spectral stability. Here we present the first phase-contrast micro-tomogram revealing quantitative electron density values of a biological sample using betatron X-rays, and a comprehensive source characterization. Our results suggest that laser-based X-ray technology offers the potential for filling the large performance gap between synchrotron- and current X-ray tube-based sources.
△ Less
Submitted 19 December, 2014;
originally announced December 2014.
-
Tunable, all-optical quasi-monochromatic Thomson X-ray source
Authors:
K. Khrennikov,
J. Wenz,
A. Buck,
J. Xu,
M. Heigoldt,
L. Veisz,
S. Karsch
Abstract:
Brilliant X-ray sources are of great interest for many research fields from biology via medicine to material research. The quest for a cost-effective, brilliant source with unprecedented temporal resolution has led to the recent realization of various high-intensity-laser-driven X-ray beam sources. Here we demonstrate the first all-laser-driven, energy-tunable and quasi-monochromatic X-ray source…
▽ More
Brilliant X-ray sources are of great interest for many research fields from biology via medicine to material research. The quest for a cost-effective, brilliant source with unprecedented temporal resolution has led to the recent realization of various high-intensity-laser-driven X-ray beam sources. Here we demonstrate the first all-laser-driven, energy-tunable and quasi-monochromatic X-ray source based on Thomson backscattering. This is a decisive step beyond previous results, where the emitted radiation exhibited an uncontrolled broad energy distribution. In the experiment, one part of the laser beam was used to drive a few-fs bunch of quasi-monoenergetic electrons from a Laser-Wakefield Accelerator (LWFA), while the remainder was scattered off the bunch in a near-counter-propagating geometry. When the electron energy was tuned from 10-50 MeV, narrow-bandwidth X-ray spectra peaking at 5-35keV were directly measured, limited in photon energy by the sensitivity curve of our X-ray detector. Due to the ultrashort LWFA electron bunches, these beams exhibit few-fs pulse duration.
△ Less
Submitted 25 June, 2014;
originally announced June 2014.
-
Temporal evolution of longitudinal bunch profile in a laser wakefield accelerator
Authors:
M. Heigoldt,
S. I. Bajlekov,
A. Popp,
K. Khrennikov,
J. Wenz,
S. W. Chou,
B. Schmidt,
S. M. Hooker,
S. Karsch
Abstract:
Due to their ultra-short duration and peak currents in the kA range, laser-wakefield accelerated electron bunches are promising drivers for ultrafast X-ray generation in compact free-electron-lasers (FELs), Thomson-scattering or betatron sources. Here we present the first single-shot, high-resolution measurements of the longitudinal bunch profile obtained without prior assumptions about the bunch…
▽ More
Due to their ultra-short duration and peak currents in the kA range, laser-wakefield accelerated electron bunches are promising drivers for ultrafast X-ray generation in compact free-electron-lasers (FELs), Thomson-scattering or betatron sources. Here we present the first single-shot, high-resolution measurements of the longitudinal bunch profile obtained without prior assumptions about the bunch shape. Our method allows complex features, such as multi-bunch structures, to be detected. Varying the length of the gas target, and thus the acceleration length, enables an assessment of the bunch profile evolution during the acceleration process. We find a minimum bunch duration of 4.2 fs (full width at half maximum) with shot-to-shot fluctuation of 11% rms. Our results suggest that after depletion of the laser energy, a transition from a laser-driven to a particle-driven wakefield occurs, associated with the injection of a secondary bunch. The resulting double-bunch structure might act as an elegant approach for driver-witness type experiments, i.e. allowing a non-dephasing-limited acceleration of the secondary bunch in a plasma-afterburner stage.
△ Less
Submitted 25 June, 2014;
originally announced June 2014.
-
Resolution of complex fluorescence spectra of lipids and nicotinic acetylcholine receptor by multivariate analysis reveals protein-mediated effects on the receptor's immediate lipid microenvironment
Authors:
Jorge J Wenz,
Francisco J Barrantes
Abstract:
Analysis of fluorescent spectra from complex biological systems containing various fluorescent probes with overlapping emission bands is a challenging task. Valuable information can be extracted from the full spectra, however, by using multivariate analysis (MA) of measurements at different wavelengths. We applied MA to spectral data of purified Torpedo nicotinic acetylcholine receptor (AChR) pr…
▽ More
Analysis of fluorescent spectra from complex biological systems containing various fluorescent probes with overlapping emission bands is a challenging task. Valuable information can be extracted from the full spectra, however, by using multivariate analysis (MA) of measurements at different wavelengths. We applied MA to spectral data of purified Torpedo nicotinic acetylcholine receptor (AChR) protein reconstituted into liposomes made up of dioleoylphosphatidic acid (DOPA) and dioleoylphosphatidylcholine (DOPC) doped with two extrinsic fluorescent probes (NBD-cholesterol/pyrene-PC). Forster resonance energy transfer (FRET) was observed between the protein and pyrene-PC and between pyrene-PC and NBD-cholesterol, leading to overlapping emission bands. Partial least squares analysis was applied to ...
△ Less
Submitted 18 February, 2009;
originally announced February 2009.