-
Investigating User Perceptions of Collaborative Agenda Setting in Virtual Health Counseling Session
Authors:
Mina Fallah,
Farnaz Nouraei,
Hye Sun Yun,
Timothy Bickmore
Abstract:
Virtual health counselors offer the potential to provide users with information and counseling in complex areas such as disease management and health education. However, ensuring user engagement is challenging, particularly when the volume of information and length of counseling sessions increase. Agenda setting a clinical counseling technique where a patient and clinician collaboratively decide o…
▽ More
Virtual health counselors offer the potential to provide users with information and counseling in complex areas such as disease management and health education. However, ensuring user engagement is challenging, particularly when the volume of information and length of counseling sessions increase. Agenda setting a clinical counseling technique where a patient and clinician collaboratively decide on session topics is an effective approach to tailoring discussions for individual patient needs and sustaining engagement. We explore the effectiveness of agenda setting in a virtual counselor system designed to counsel women for breast cancer genetic testing. In a between subjects study, we assessed three versions of the system with varying levels of user control in the system's agenda setting approach. We found that participants' knowledge improved across all conditions. Although our results showed that any type of agenda setting was perceived as useful, regardless of user control, interviews revealed a preference for more collaboration and user involvement in the agenda setting process. Our study highlights the importance of using patient-centered approaches, such as tailored discussions, when using virtual counselors in healthcare.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Automatically Extracting Numerical Results from Randomized Controlled Trials with Large Language Models
Authors:
Hye Sun Yun,
David Pogrebitskiy,
Iain J. Marshall,
Byron C. Wallace
Abstract:
Meta-analyses statistically aggregate the findings of different randomized controlled trials (RCTs) to assess treatment effectiveness. Because this yields robust estimates of treatment effectiveness, results from meta-analyses are considered the strongest form of evidence. However, rigorous evidence syntheses are time-consuming and labor-intensive, requiring manual extraction of data from individu…
▽ More
Meta-analyses statistically aggregate the findings of different randomized controlled trials (RCTs) to assess treatment effectiveness. Because this yields robust estimates of treatment effectiveness, results from meta-analyses are considered the strongest form of evidence. However, rigorous evidence syntheses are time-consuming and labor-intensive, requiring manual extraction of data from individual trials to be synthesized. Ideally, language technologies would permit fully automatic meta-analysis, on demand. This requires accurately extracting numerical results from individual trials, which has been beyond the capabilities of natural language processing (NLP) models to date. In this work, we evaluate whether modern large language models (LLMs) can reliably perform this task. We annotate (and release) a modest but granular evaluation dataset of clinical trial reports with numerical findings attached to interventions, comparators, and outcomes. Using this dataset, we evaluate the performance of seven LLMs applied zero-shot for the task of conditionally extracting numerical findings from trial reports. We find that massive LLMs that can accommodate lengthy inputs are tantalizingly close to realizing fully automatic meta-analysis, especially for dichotomous (binary) outcomes (e.g., mortality). However, LLMs -- including ones trained on biomedical texts -- perform poorly when the outcome measures are complex and tallying the results requires inference. This work charts a path toward fully automatic meta-analysis of RCTs via LLMs, while also highlighting the limitations of existing models for this aim.
△ Less
Submitted 24 July, 2024; v1 submitted 2 May, 2024;
originally announced May 2024.
-
Electrically Programmable Pixelated Graphene-Integrated Plasmonic Metasurfaces for Coherent Mid-Infrared Emission
Authors:
Xiu Liu,
Yibai Zhong,
Zexiao Wang,
Tianyi Huang,
Sen Lin,
Jingyi Zou,
Haozhe Wang,
Zhien Wang,
Zhuo Li,
Xiao Luo,
Rui Cheng,
Jiayu Li,
Hyeong Seok Yun,
Han Wang,
Jing Kong,
Xu Zhang,
Sheng Shen
Abstract:
Active metasurfaces have recently emerged as compact, lightweight, and efficient platforms for dynamic control of electromagnetic fields and optical responses. However, the complexities associated with their post-fabrication tunability significantly hinder their widespread applications, especially for the mid-infrared range due to material scarcity and design intricacy. Here, we experimentally dem…
▽ More
Active metasurfaces have recently emerged as compact, lightweight, and efficient platforms for dynamic control of electromagnetic fields and optical responses. However, the complexities associated with their post-fabrication tunability significantly hinder their widespread applications, especially for the mid-infrared range due to material scarcity and design intricacy. Here, we experimentally demonstrate highly dynamic, pixelated modulations of coherent mid-infrared emission based on an electrically programmable plasmonic metasurface integrated with graphene field effect transistors (Gr-FETs). The ultrabroad infrared transparency of graphene allows for free-form control over plasmonic meta-atoms, thus achieving coherent mid-infrared states across a broad range of wavelengths and polarizations. The spatial temperature modulation generated by Gr-FETs is effectively synergized with the emissivity control by the localized surface plasmon polaritons from gold nanoantennas. This integrated temperature-emissivity modulation of metasurfaces is systematically extended to form a pixelated 2D array, envisioning new approaches toward scalable 2D electrical wiring for densely packed, independently controlled pixels.
△ Less
Submitted 6 May, 2024; v1 submitted 11 March, 2024;
originally announced March 2024.
-
Keeping Users Engaged During Repeated Administration of the Same Questionnaire: Using Large Language Models to Reliably Diversify Questions
Authors:
Hye Sun Yun,
Mehdi Arjmand,
Phillip Sherlock,
Michael K. Paasche-Orlow,
James W. Griffith,
Timothy Bickmore
Abstract:
Standardized, validated questionnaires are vital tools in research and healthcare, offering dependable self-report data. Prior work has revealed that virtual agent-administered questionnaires are almost equivalent to self-administered ones in an electronic form. Despite being an engaging method, repeated use of virtual agent-administered questionnaires in longitudinal or pre-post studies can induc…
▽ More
Standardized, validated questionnaires are vital tools in research and healthcare, offering dependable self-report data. Prior work has revealed that virtual agent-administered questionnaires are almost equivalent to self-administered ones in an electronic form. Despite being an engaging method, repeated use of virtual agent-administered questionnaires in longitudinal or pre-post studies can induce respondent fatigue, impacting data quality via response biases and decreased response rates. We propose using large language models (LLMs) to generate diverse questionnaire versions while retaining good psychometric properties. In a longitudinal study, participants interacted with our agent system and responded daily for two weeks to one of the following questionnaires: a standardized depression questionnaire, question variants generated by LLMs, or question variants accompanied by LLM-generated small talk. The responses were compared to a validated depression questionnaire. Psychometric testing revealed consistent covariation between the external criterion and focal measure administered across the three conditions, demonstrating the reliability and validity of the LLM-generated variants. Participants found that the variants were significantly less repetitive than repeated administrations of the same standardized questionnaire. Our findings highlight the potential of LLM-generated variants to invigorate agent-administered questionnaires and foster engagement and interest, without compromising their validity.
△ Less
Submitted 6 July, 2024; v1 submitted 21 November, 2023;
originally announced November 2023.
-
Brochosome-inspired binary metastructures for pixel-by-pixel thermal signature control
Authors:
Zhuo Li,
Lin Wang,
Xiu Liu,
Jiayu Li,
Hyeong Seok Yun,
Zexiao Wang,
Xu Zhang,
Tak-Sing Wong,
Sheng Shen
Abstract:
In nature, nano/micro-structured materials are adopted by various species to generate colors or achieve camouflage. Here, inspired by leafhopper-generated brochosomes, we design binary metastructures composed of pixel twins to achieve pixelated thermal signature control at the microscale. In the infrared range, the pixel twins exhibit distinct emissivities, creating thermal counterparts of '0-1' b…
▽ More
In nature, nano/micro-structured materials are adopted by various species to generate colors or achieve camouflage. Here, inspired by leafhopper-generated brochosomes, we design binary metastructures composed of pixel twins to achieve pixelated thermal signature control at the microscale. In the infrared range, the pixel twins exhibit distinct emissivities, creating thermal counterparts of '0-1' binary states for storing and displaying information. In the visible range, the engineered surface morphology of the pixel twins enables similar scattering behaviors, rendering the pixel twins visually indistinguishable, which achieves the camouflage of stored information. Compared to the previous work based on plasmonic holographic metasurfaces, the brochosome-like pixel twins are thermally driven, and their structure-enabled functions do not rely on permittivities of any specific material. The unique combination of visible camouflage and infrared display provides a systemic solution to the spatial control of thermal signatures, and has important implications for optical security, anticounterfeiting, and data encryption.
△ Less
Submitted 1 November, 2023; v1 submitted 27 October, 2023;
originally announced October 2023.
-
Appraising the Potential Uses and Harms of LLMs for Medical Systematic Reviews
Authors:
Hye Sun Yun,
Iain J. Marshall,
Thomas A. Trikalinos,
Byron C. Wallace
Abstract:
Medical systematic reviews play a vital role in healthcare decision making and policy. However, their production is time-consuming, limiting the availability of high-quality and up-to-date evidence summaries. Recent advancements in large language models (LLMs) offer the potential to automatically generate literature reviews on demand, addressing this issue. However, LLMs sometimes generate inaccur…
▽ More
Medical systematic reviews play a vital role in healthcare decision making and policy. However, their production is time-consuming, limiting the availability of high-quality and up-to-date evidence summaries. Recent advancements in large language models (LLMs) offer the potential to automatically generate literature reviews on demand, addressing this issue. However, LLMs sometimes generate inaccurate (and potentially misleading) texts by hallucination or omission. In healthcare, this can make LLMs unusable at best and dangerous at worst. We conducted 16 interviews with international systematic review experts to characterize the perceived utility and risks of LLMs in the specific context of medical evidence reviews. Experts indicated that LLMs can assist in the writing process by drafting summaries, generating templates, distilling information, and crosschecking information. They also raised concerns regarding confidently composed but inaccurate LLM outputs and other potential downstream harms, including decreased accountability and proliferation of low-quality reviews. Informed by this qualitative analysis, we identify criteria for rigorous evaluation of biomedical LLMs aligned with domain expert views.
△ Less
Submitted 18 October, 2023; v1 submitted 19 May, 2023;
originally announced May 2023.
-
Challenges in Designing Teacher Robots with Motivation Based Gestures
Authors:
Hae Seon Yun,
Volha Taliaronak,
Murat Kirtay,
Johann Chevelère,
Heiko Hübert,
Verena V. Hafner,
Niels Pinkwart,
Rebecca Lazarides
Abstract:
Humanoid robots are increasingly being integrated into learning contexts to assist teaching and learning. However, challenges remain how to design and incorporate such robots in an educational context. As an important part of teaching includes monitoring the motivational and emotional state of the learner and adapting the interaction style and learning content accordingly, in this paper, we discus…
▽ More
Humanoid robots are increasingly being integrated into learning contexts to assist teaching and learning. However, challenges remain how to design and incorporate such robots in an educational context. As an important part of teaching includes monitoring the motivational and emotional state of the learner and adapting the interaction style and learning content accordingly, in this paper, we discuss the role of gestures displayed by a humanoid robot (i.e., Pepper robot) in a learning and teaching context and present our ongoing research on designing and developing a teacher robot.
△ Less
Submitted 8 February, 2023;
originally announced February 2023.
-
Accurate Direct Measurements of Far-Field Thermal Infrared Emission and its Dynamics
Authors:
Xiu Liu,
Hakan Salihoglu,
Xiao Luo,
Hyeong Seok Yun,
Lin Jing,
Bowen Yu,
Sheng Shen
Abstract:
Accurate direct measurements of far-field thermal infrared emission become increasingly important because conventional methods, relying on indirect assessments, such as reflectance/transmittance, are inaccurate or even unfeasible to characterize state-of-art devices with novel spectra, directionalities, and polarizations. The direct collection of the far-field emission from these tiny devices is a…
▽ More
Accurate direct measurements of far-field thermal infrared emission become increasingly important because conventional methods, relying on indirect assessments, such as reflectance/transmittance, are inaccurate or even unfeasible to characterize state-of-art devices with novel spectra, directionalities, and polarizations. The direct collection of the far-field emission from these tiny devices is also challenging because of their shrinking footprints and uncontrollable radiation noises from their surroundings. Here, we demonstrate a microscopic lock-in FTIR system that realizes significant improvement in signal-to-noise ratio (SNR) by combining a microscope and a lock-in amplifier with an FTIR. The lock-in FTIR is ultrasensitive, with a specific detectivity 10^6 times higher than commercial ones, to overcome the optical loss and background noise during the emission light collection. Based on an analytical model of the signal detection process, we also explore the combination of modulated Joule heating and global heating to fulfill the potential of our system for noise reduction. Our findings show that, compared to previous studies, more than 3 times lower temperatures are sufficient to generate a measurable signal. Under a heating temperature of around 125 °C, we can achieve an SNR of about 23.7, which is far above the true-signal-threshold (SNR of about 3.0). Furthermore, the system can respond fast enough (up to 175kHz) to record spectral-resolved dynamics of microdevices in the frequency domain. The measurable frequency range can be extended up to MHz or even GHz level by a high-speed circuit model. We believe the system together with the analytical signal processing can be beneficial for next-generation thermal infrared material and device exploration, boosting the applications in lighting, sensing, imaging, and energy harvesting on a small scale.
△ Less
Submitted 22 September, 2022; v1 submitted 25 August, 2022;
originally announced September 2022.
-
Design and analysis of electrothermal metasurfaces
Authors:
Xiu Liu,
Zhuo Li,
Zexiao Wang,
Hyeong Seok Yun,
Sheng Shen
Abstract:
Electrothermal metasurfaces have attracted extensive attention due to their ability to dynamically control thermal infrared radiation. Although previous studies were mainly focused on the metasurfaces with infinite unit cells, the finite-size effect can be a critical design factor for developing thermal metasurfaces with fast response and broad temperature uniformity in practice. Here, we study th…
▽ More
Electrothermal metasurfaces have attracted extensive attention due to their ability to dynamically control thermal infrared radiation. Although previous studies were mainly focused on the metasurfaces with infinite unit cells, the finite-size effect can be a critical design factor for developing thermal metasurfaces with fast response and broad temperature uniformity in practice. Here, we study the thermal metasurfaces consisting of gold nanorods with a finite array size, which, with only several periods, can achieve a resonance close to that of the infinite case. More importantly, such a small footprint due to the finite array size results in the response time down to a nanosecond level. Furthermore, the number of the unit cells in the direction perpendicular to the axis of the nanorods is found to be insensitive to the resonance and response time, thus providing a tunability in aspect ratio that can boost the temperature uniformity in the sub-Kelvin level.
△ Less
Submitted 27 June, 2022;
originally announced June 2022.
-
Metal Artifact Reduction with Intra-Oral Scan Data for 3D Low Dose Maxillofacial CBCT Modeling
Authors:
Chang Min Hyun,
Taigyntuya Bayaraa,
Hye Sun Yun,
Tae Jun Jang,
Hyoung Suk Park,
Jin Keun Seo
Abstract:
Low-dose dental cone beam computed tomography (CBCT) has been increasingly used for maxillofacial modeling. However, the presence of metallic inserts, such as implants, crowns, and dental filling, causes severe streaking and shading artifacts in a CBCT image and loss of the morphological structures of the teeth, which consequently prevents accurate segmentation of bones. A two-stage metal artifact…
▽ More
Low-dose dental cone beam computed tomography (CBCT) has been increasingly used for maxillofacial modeling. However, the presence of metallic inserts, such as implants, crowns, and dental filling, causes severe streaking and shading artifacts in a CBCT image and loss of the morphological structures of the teeth, which consequently prevents accurate segmentation of bones. A two-stage metal artifact reduction method is proposed for accurate 3D low-dose maxillofacial CBCT modeling, where a key idea is to utilize explicit tooth shape prior information from intra-oral scan data whose acquisition does not require any extra radiation exposure. In the first stage, an image-to-image deep learning network is employed to mitigate metal-related artifacts. To improve the learning ability, the proposed network is designed to take advantage of the intra-oral scan data as side-inputs and perform multi-task learning of auxiliary tooth segmentation. In the second stage, a 3D maxillofacial model is constructed by segmenting the bones from the dental CBCT image corrected in the first stage. For accurate bone segmentation, weighted thresholding is applied, wherein the weighting region is determined depending on the geometry of the intra-oral scan data. Because acquiring a paired training dataset of metal-artifact-free and metal artifact-affected dental CBCT images is challenging in clinical practice, an automatic method of generating a realistic dataset according to the CBCT physics model is introduced. Numerical simulations and clinical experiments show the feasibility of the proposed method, which takes advantage of tooth surface information from intra-oral scan data in 3D low dose maxillofacial CBCT modeling.
△ Less
Submitted 7 February, 2022;
originally announced February 2022.
-
Fully automatic integration of dental CBCT images and full-arch intraoral impressions with stitching error correction via individual tooth segmentation and identification
Authors:
Tae Jun Jang,
Hye Sun Yun,
Chang Min Hyun,
Jong-Eun Kim,
Sang-Hwy Lee,
Jin Keun Seo
Abstract:
We present a fully automated method of integrating intraoral scan (IOS) and dental cone-beam computerized tomography (CBCT) images into one image by complementing each image's weaknesses. Dental CBCT alone may not be able to delineate precise details of the tooth surface due to limited image resolution and various CBCT artifacts, including metal-induced artifacts. IOS is very accurate for the scan…
▽ More
We present a fully automated method of integrating intraoral scan (IOS) and dental cone-beam computerized tomography (CBCT) images into one image by complementing each image's weaknesses. Dental CBCT alone may not be able to delineate precise details of the tooth surface due to limited image resolution and various CBCT artifacts, including metal-induced artifacts. IOS is very accurate for the scanning of narrow areas, but it produces cumulative stitching errors during full-arch scanning. The proposed method is intended not only to compensate the low-quality of CBCT-derived tooth surfaces with IOS, but also to correct the cumulative stitching errors of IOS across the entire dental arch. Moreover, the integration provide both gingival structure of IOS and tooth roots of CBCT in one image. The proposed fully automated method consists of four parts; (i) individual tooth segmentation and identification module for IOS data (TSIM-IOS); (ii) individual tooth segmentation and identification module for CBCT data (TSIM-CBCT); (iii) global-to-local tooth registration between IOS and CBCT; and (iv) stitching error correction of full-arch IOS. The experimental results show that the proposed method achieved landmark and surface distance errors of 112.4 $μ$m and 301.7 $μ$m, respectively.
△ Less
Submitted 2 March, 2023; v1 submitted 3 December, 2021;
originally announced December 2021.
-
Automated 3D cephalometric landmark identification using computerized tomography
Authors:
Hye Sun Yun,
Chang Min Hyun,
Seong Hyeon Baek,
Sang-Hwy Lee,
Jin Keun Seo
Abstract:
Identification of 3D cephalometric landmarks that serve as proxy to the shape of human skull is the fundamental step in cephalometric analysis. Since manual landmarking from 3D computed tomography (CT) images is a cumbersome task even for the trained experts, automatic 3D landmark detection system is in a great need. Recently, automatic landmarking of 2D cephalograms using deep learning (DL) has a…
▽ More
Identification of 3D cephalometric landmarks that serve as proxy to the shape of human skull is the fundamental step in cephalometric analysis. Since manual landmarking from 3D computed tomography (CT) images is a cumbersome task even for the trained experts, automatic 3D landmark detection system is in a great need. Recently, automatic landmarking of 2D cephalograms using deep learning (DL) has achieved great success, but 3D landmarking for more than 80 landmarks has not yet reached a satisfactory level, because of the factors hindering machine learning such as the high dimensionality of the input data and limited amount of training data due to ethical restrictions on the use of medical data. This paper presents a semi-supervised DL method for 3D landmarking that takes advantage of anonymized landmark dataset with paired CT data being removed. The proposed method first detects a small number of easy-to-find reference landmarks, then uses them to provide a rough estimation of the entire landmarks by utilizing the low dimensional representation learned by variational autoencoder (VAE). Anonymized landmark dataset is used for training the VAE. Finally, coarse-to-fine detection is applied to the small bounding box provided by rough estimation, using separate strategies suitable for mandible and cranium. For mandibular landmarks, patch-based 3D CNN is applied to the segmented image of the mandible (separated from the maxilla), in order to capture 3D morphological features of mandible associated with the landmarks. We detect 6 landmarks around the condyle all at once, instead of one by one, because they are closely related to each other. For cranial landmarks, we again use VAE-based latent representation for more accurate annotation. In our experiment, the proposed method achieved an averaged 3D point-to-point error of 2.91 mm for 90 landmarks only with 15 paired training data.
△ Less
Submitted 16 December, 2020;
originally announced January 2021.
-
Evolution of Magnetic Field in AR 5747 and Its Approximation as a Linear Force Free Field
Authors:
Y. -J. Moon,
H. S. Yun,
G. S. Choe,
Y. D. Park,
D. L. Mickey
Abstract:
The evolution of nonpotential characteristics of magnetic fields in AR 5747 is presented using Mees Solar Observatory magnetograms taken on Oct. 20, 1989 to Oct. 22, 1989. The active region showed such violent flaring activities during the observational span that strong X-ray flares took place including a 2B/X3 flare. The magnetogram data were obtained by the Haleakala Stokes Polarimeter which p…
▽ More
The evolution of nonpotential characteristics of magnetic fields in AR 5747 is presented using Mees Solar Observatory magnetograms taken on Oct. 20, 1989 to Oct. 22, 1989. The active region showed such violent flaring activities during the observational span that strong X-ray flares took place including a 2B/X3 flare. The magnetogram data were obtained by the Haleakala Stokes Polarimeter which provides simultaneous Stokes profiles of the Fe I doublet 6301.5 and 6302.5. A nonlinear least square method was adopted to derive the magnetic field vectors from the observed Stokes profiles and a multi-step ambiguity solution method was employed to resolve the 180 degree ambiguity.
From the ambiguity-resolved vector magnetograms, we have derived a set of physical quantities characterizing the field configuration, which are magnetic flux, vertical current density, magnetic shear angle, angular shear, magnetic free energy density and a measure of magnetic field discontinuity MAD (Maximum Angular Difference between two adjacent field vectors). In our results, all the physical parameters decreased with time, which implies that the active region was in a relaxation stage of its evolution. To examine the force-free characteristics of the field, we calculated the integrated Lorentz force and and also compared the longitudinal field component with the corresponding vertical current density. In this investigation, we found that the magnetic field in this active region was approximately linearly force-free throughout the observing period. The time variation of the linear force-free coefficient is consistent with the evolutionary trend of other nonpotentiality parameters. This suggests that the linear force-free coefficient could be a good indicator of the evolutionary status of active regions.
△ Less
Submitted 4 October, 1999;
originally announced October 1999.
-
Evolution of Magnetic Non-potentiality associated with an X-class Flare in AR 6919
Authors:
Y. -J. Moon,
H. S. Yun,
G. S. Choe,
Y. D. Park,
D. L. Mickey
Abstract:
We present the evolution of magnetic nonpotentiality associated with an X-class flare in AR 6919 using a set of MSO (Mees Solar Observatory) magnetograms. The magnetogram data were obtained before and after the flare, using the Haleakala Stokes Polarimeter which provides simultaneous Stokes profiles of the Fe I doublet 6301.5 and 6302.5. A nonlinear least square method was adopted to derive the…
▽ More
We present the evolution of magnetic nonpotentiality associated with an X-class flare in AR 6919 using a set of MSO (Mees Solar Observatory) magnetograms. The magnetogram data were obtained before and after the flare, using the Haleakala Stokes Polarimeter which provides simultaneous Stokes profiles of the Fe I doublet 6301.5 and 6302.5. A nonlinear least square method was adopted to derive the magnetic field configuration from the observed Stokes profiles and a multi-step ambiguity solution method was employed to resolve the 180 degree ambiguity. From the ambiguity-resolved vector magnetograms, we have derived a set of physical quantities characterizing the field configuration such as vertical current density, magnetic shear angle, angular shear and magnetic free energy density. We have examined their changes before and after the flare occurrence and obtained the following results. 1) There was a flux decrease in both polarities around a delta-type sunspot region, where an X-class flare occurred. 2) The vertical current near the delta sunspot region was strongly enhanced before the flare. 3) The magnetic shear near the delta sunspot region increased before the flare and then decreased after it. 4) The sum of magnetic energy density significantly decreased before the flare onset, implying that magnetic free energy was released through the flaring processes.
△ Less
Submitted 4 October, 1999;
originally announced October 1999.
-
Study of Solar Active Regions Based on BOAO Vector Magnetograms
Authors:
Y. -J. Moon,
Y. D. Park,
H. S. Yun,
E. -A. Cho
Abstract:
In this study we present the study of solar active regions based on BOAO vector magnetograms and $Hα$ filtergrams. With the new calibration method we analyzed BOAO vector magnetograms taken from the SOFT observational system to compare with those of other observing systems. In this study it has been demonstrated that (1) our longitudinal magnetogram matches very well the corresponding Mitaka's m…
▽ More
In this study we present the study of solar active regions based on BOAO vector magnetograms and $Hα$ filtergrams. With the new calibration method we analyzed BOAO vector magnetograms taken from the SOFT observational system to compare with those of other observing systems. In this study it has been demonstrated that (1) our longitudinal magnetogram matches very well the corresponding Mitaka's magnetogram to the extent that the maximum correlation yields r=0.962 between our re-scaled longitudinal magnetogram and the Mitaka's magnetogram; (2) according to a comparison of our magnetograms of AR 8422 with those taken at Mitaka solar observatory their longitudinal fields are very similar to each other while transverse fields are a little different possibly due to large noise level; (3) main features seen by our longitudinal magnetograms of AR 8422 and AR 8419 and the corresponding Kitt Peak magnetograms are very similar to each other; (4) time series of our vector magnetograms and H-alpha observations of AR 8419 during its flaring (M3.1/1B) activity show that the filament eruption followed the sheared inversion line of the quadrupolar configuration of sunspots, indicating that the flare should be associated with the quadrupolar field configuration and its interaction with new filament eruption. Finally, it may be concluded that the Solar Flare Telescope at BOAO works normally and it is ready to do numerous observational and theoretical works associated with solar activities such as flares.
△ Less
Submitted 4 October, 1999;
originally announced October 1999.