Data-driven imaging geometric recovery of ultrahigh resolution robotic micro-CT for in-vivo and other applications
Authors:
Mengzhou Li,
Guibin Zan,
Wenbin Yun,
Josef Uher,
John Wen,
Ge Wang
Abstract:
We introduce an ultrahigh-resolution (50μm\) robotic micro-CT design for localized imaging of carotid plaques using robotic arms, cutting-edge detector, and machine learning technologies. To combat geometric error-induced artifacts in interior CT scans, we propose a data-driven geometry estimation method that maximizes the consistency between projection data and the reprojection counterparts of a…
▽ More
We introduce an ultrahigh-resolution (50μm\) robotic micro-CT design for localized imaging of carotid plaques using robotic arms, cutting-edge detector, and machine learning technologies. To combat geometric error-induced artifacts in interior CT scans, we propose a data-driven geometry estimation method that maximizes the consistency between projection data and the reprojection counterparts of a reconstructed volume. Particularly, we use a normalized cross correlation metric to overcome the projection truncation effect. Our approach is validated on a robotic CT scan of a sacrificed mouse and a micro-CT phantom scan, both producing sharper images with finer details than that prior correction.
△ Less
Submitted 26 June, 2024;
originally announced June 2024.
-
Subspace modeling for fast and high-sensitivity X-ray chemical imaging
Authors:
Jizhou Li,
Bin Chen,
Guibin Zan,
Guannan Qian,
Piero Pianetta,
Yijin Liu
Abstract:
Resolving morphological chemical phase transformations at the nanoscale is of vital importance to many scientific and industrial applications across various disciplines. The TXM-XANES imaging technique, by combining full field transmission X-ray microscopy (TXM) and X-ray absorption near edge structure (XANES), has been an emerging tool which operates by acquiring a series of microscopy images wit…
▽ More
Resolving morphological chemical phase transformations at the nanoscale is of vital importance to many scientific and industrial applications across various disciplines. The TXM-XANES imaging technique, by combining full field transmission X-ray microscopy (TXM) and X-ray absorption near edge structure (XANES), has been an emerging tool which operates by acquiring a series of microscopy images with multi-energy X-rays and fitting to obtain the chemical map. Its capability, however, is limited by the poor signal-to-noise ratios due to the system errors and low exposure illuminations for fast acquisition. In this work, by exploiting the intrinsic properties and subspace modeling of the TXM-XANES imaging data, we introduce a simple and robust denoising approach to improve the image quality, which enables fast and high-sensitivity chemical imaging. Extensive experiments on both synthetic and real datasets demonstrate the superior performance of the proposed method.
△ Less
Submitted 1 January, 2022;
originally announced January 2022.
-
Preliminary demonstration of flexible dual-energy X-ray phase-contrast imaging
Authors:
Shenghao Wang,
Guibin Zan,
Qiuping Wang,
Shijie Liu
Abstract:
Currently, dual-energy X-ray phase contrast imaging is usually conducted with an X-ray Talbot-Lau interferometer. However, in this system, the two adopted energy spectra have to be chosen carefully in order to match well with the phase grating. For example, the accelerating voltages of the X-ray tube are supposed to be respectively set as 40 kV and 70 kV, with other energy spectra being practicall…
▽ More
Currently, dual-energy X-ray phase contrast imaging is usually conducted with an X-ray Talbot-Lau interferometer. However, in this system, the two adopted energy spectra have to be chosen carefully in order to match well with the phase grating. For example, the accelerating voltages of the X-ray tube are supposed to be respectively set as 40 kV and 70 kV, with other energy spectra being practically unusable for dual energy imaging. This system thus has low flexibility and maneuverability in practical applications. In this work, dual energy X-ray phase-contrast imaging is performed in a grating-based non-interferometric imaging system rather than in a Talbot-Lau interferometer. The advantage of this system is that, theoretically speaking, any two separated energy spectra can be utilized to perform dual energy X-ray phase-contrast imaging. The preliminary experimental results show that dual-energy X-ray phase contrast imaging is successfully performed when the accelerating voltages of the X-ray tube are successively set as 40 kV and 50 kV. Our work increases the flexibility and maneuverability when employing dual-energy X-ray phase-contrast imaging in medical diagnoses and nondestructive tests.
△ Less
Submitted 7 November, 2019;
originally announced November 2019.
-
Toward a fractal spectrum approach for neutron and gamma pulse shape discrimination
Authors:
Mingzhe Liu,
Bingqi Liu,
Zhuo Zuo,
Lei Wang,
Guibin Zan,
Xianguo Tuo
Abstract:
There is a key research issue to accurately select out neutron signals and discriminate gamma signals from a mixed radiation field in the neutron detection. This paper proposes a fractal spectrum discrimination approach by means of different spectrum characteristics of neutron and gamma. Figure of merit and average discriminant error ratio are adopted together to evaluate the discriminant effects.…
▽ More
There is a key research issue to accurately select out neutron signals and discriminate gamma signals from a mixed radiation field in the neutron detection. This paper proposes a fractal spectrum discrimination approach by means of different spectrum characteristics of neutron and gamma. Figure of merit and average discriminant error ratio are adopted together to evaluate the discriminant effects. Different neutron and gamma signals with various noises and pulse pile-ups are simulated according to real data in the literature. The proposed approach is compared with the digital charge integration and pulse gradient methods. It is found that the fractal approach exhibits the best discriminant performance among three methods. The fractal spectrum approach is not sensitive to the high frequency noises and pulse pile-ups. It means that the proposed approach takes the advantages of anti-noises and high discriminant ability, and can be used to better discriminate neutron and gamma in neutron detection.
△ Less
Submitted 22 January, 2016; v1 submitted 6 May, 2015;
originally announced May 2015.