Apercal -- The Apertif Calibration Pipeline
Authors:
B. Adebahr,
R. Schulz,
T. J. Dijkema,
V. A. Moss,
A. R. Offringa,
A. Kutkin,
J. M. van der Hulst,
B. S. Frank,
N. P. E. Vilchez,
J. Verstappen,
E. K. Adams,
W. J. G. de Blok,
H. Denes,
K. M. Hess,
D. Lucero,
R. Morganti,
T. Oosterloo,
D. -J. Pisano,
M. V. Ivashina,
W. A. van Cappellen,
L. D. Connor,
A. H. W. M. Coolen,
S. Damstra,
G. M. Loose,
Y. Maan
, et al. (11 additional authors not shown)
Abstract:
Apertif (APERture Tile In Focus) is one of the Square Kilometre Array (SKA) pathfinder facilities. The Apertif project is an upgrade to the 50-year-old Westerbork Synthesis Radio Telescope (WSRT) using phased-array feed technology. The new receivers create 40 individual beams on the sky, achieving an instantaneous sky coverage of 6.5 square degrees. The primary goal of the Apertif Imaging Survey i…
▽ More
Apertif (APERture Tile In Focus) is one of the Square Kilometre Array (SKA) pathfinder facilities. The Apertif project is an upgrade to the 50-year-old Westerbork Synthesis Radio Telescope (WSRT) using phased-array feed technology. The new receivers create 40 individual beams on the sky, achieving an instantaneous sky coverage of 6.5 square degrees. The primary goal of the Apertif Imaging Survey is to perform a wide survey of 3500 square degrees (AWES) and a medium deep survey of 350 square degrees (AMES) of neutral atomic hydrogen (up to a redshift of 0.26), radio continuum emission and polarisation. Each survey pointing yields 4.6 TB of correlated data. The goal of Apercal is to process this data and fully automatically generate science ready data products for the astronomical community while keeping up with the survey observations. We make use of common astronomical software packages in combination with Python based routines and parallelisation. We use an object oriented module-based approach to ensure easy adaptation of the pipeline. A Jupyter notebook based framework allows user interaction and execution of individual modules as well as a full automatic processing of a complete survey observation. If nothing interrupts processing, we are able to reduce a single pointing survey observation on our five node cluster with 24 physical cores and 256 GB of memory each within 24h keeping up with the speed of the surveys. The quality of the generated images is sufficient for scientific usage for 44 % of the recorded data products with single images reaching dynamic ranges of several thousands. Future improvements will increase this percentage to over 80 %. Our design allowed development of the pipeline in parallel to the commissioning of the Apertif system.
△ Less
Submitted 7 December, 2021;
originally announced December 2021.
Photoluminescence in amorphous MgSiO_3 silicate
Authors:
S. P. Thompson,
J. E. Parker,
S. J. Day,
L. D. Connor,
A. Evans
Abstract:
Samples of amorphous MgSiO_3 annealed at temperature steps leading up to their crystallisation temperature show a rise in photoluminescence activity, peaking at ~450C. The photoluminescence band has a main peak at 595nm and a weaker peak at 624nm. We present laboratory data to show that the maximum in photoluminescence activity is related to substantial structural reordering that occurs within a r…
▽ More
Samples of amorphous MgSiO_3 annealed at temperature steps leading up to their crystallisation temperature show a rise in photoluminescence activity, peaking at ~450C. The photoluminescence band has a main peak at 595nm and a weaker peak at 624nm. We present laboratory data to show that the maximum in photoluminescence activity is related to substantial structural reordering that occurs within a relatively narrow temperature range. We attribute the origin of the photoluminescence to non-bridging oxygen hole centre defects, which form around ordered nano-sized domain structures as a result of the breakup of tetrahedral connectivity in the disordered inter-domain network, aided by the loss of bonded OH. These defects are removed as crystallisation progresses, resulting in the decrease and eventual loss of photoluminescence. Thermally processed hydrogenated amorphous silicate grains could therefore represent a potential carrier of extended red emission.
△ Less
Submitted 2 July, 2013;
originally announced July 2013.