First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
Authors:
J. Aalbers,
D. S. Akerib,
C. W. Akerlof,
A. K. Al Musalhi,
F. Alder,
A. Alqahtani,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
S. Azadi,
A. J. Bailey,
A. Baker,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
M. J. Barry,
J. Barthel,
D. Bauer,
A. Baxter
, et al. (322 additional authors not shown)
Abstract:
The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis s…
▽ More
The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis shows the data to be consistent with a background-only hypothesis, setting new limits on spin-independent WIMP-nucleon, spin-dependent WIMP-neutron, and spin-dependent WIMP-proton cross sections for WIMP masses above 9 GeV/c$^2$. The most stringent limit is set for spin-independent scattering at 36 GeV/c$^2$, rejecting cross sections above 9.2$\times 10^{-48}$ cm$^2$ at the 90% confidence level.
△ Less
Submitted 2 August, 2023; v1 submitted 8 July, 2022;
originally announced July 2022.
-
Design and production of the high voltage electrode grids and electron extraction region for the LZ dual-phase xenon time projection chamber
Authors:
R. Linehan,
R. L. Mannino,
A. Fan,
C. M. Ignarra,
S. Luitz,
K. Skarpaas,
T. A. Shutt,
D. S. Akerib,
S. K. Alsum,
T. J. Anderson,
H. M. Araújo,
M. Arthurs,
H. Auyeung,
A. J. Bailey,
T. P. Biesiadzinski,
M. Breidenbach,
J. J. Cherwinka,
R. A. Conley,
J. Genovesi,
M. G. D. Gilchriese,
A. Glaenzer,
T. G. Gonda,
K. Hanzel,
M. D. Hoff,
W. Ji
, et al. (24 additional authors not shown)
Abstract:
The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of th…
▽ More
The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of the electrodes used to establish these fields is therefore required. We present the design and production of the LUX-ZEPLIN (LZ) experiment's high-voltage electrodes, a set of four woven mesh wire grids. Grid design drivers are discussed, with emphasis placed on design of the electron extraction region. We follow this with a description of the grid production process and a discussion of steps taken to validate the LZ grids prior to integration into the TPC.
△ Less
Submitted 11 June, 2021;
originally announced June 2021.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
Authors:
D. S. Akerib,
C. W. Akerlof,
S. K. Alsum,
H. M. Araújo,
M. Arthurs,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
D. Bauer,
J. Belle,
P. Beltrame,
T. Benson,
E. P. Bernard,
T. P. Biesiadzinski,
K. E. Boast,
B. Boxer,
P. Brás,
J. H. Buckley,
V. V. Bugaev,
S. Burdin,
J. K. Busenitz,
C. Carels,
D. L. Carlsmith,
B. Carlson
, et al. (153 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7~tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up…
▽ More
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7~tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector.
For a 1000~live day run using a 5.6~tonne fiducial mass, LZ is projected to exclude at 90\% confidence level spin-independent WIMP-nucleon cross sections above $1.4 \times 10^{-48}$~cm$^{2}$ for a 40~$\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5σ$ discovery potential is projected reaching cross sections below the exclusion limits of recent experiments. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.3 \times 10^{-43}$~cm$^{2}$ ($7.1 \times 10^{-42}$~cm$^{2}$) for a 40~$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020.
△ Less
Submitted 2 December, 2019; v1 submitted 16 February, 2018;
originally announced February 2018.
-
LUX-ZEPLIN (LZ) Technical Design Report
Authors:
B. J. Mount,
S. Hans,
R. Rosero,
M. Yeh,
C. Chan,
R. J. Gaitskell,
D. Q. Huang,
J. Makkinje,
D. C. Malling,
M. Pangilinan,
C. A. Rhyne,
W. C. Taylor,
J. R. Verbus,
Y. D. Kim,
H. S. Lee,
J. Lee,
D. S. Leonard,
J. Li,
J. Belle,
A. Cottle,
W. H. Lippincott,
D. J. Markley,
T. J. Martin,
M. Sarychev,
T. E. Tope
, et al. (237 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
△ Less
Submitted 27 March, 2017;
originally announced March 2017.