-
Track length measurement of $^{19}$F$^+$ ions with the MIMAC Dark Matter directional detector prototype
Authors:
Y. Tao,
C. Beaufort,
I. Moric,
C. Tao,
D. Santos,
N. Sauzet,
C. Couturier,
O. Guillaudin,
J. F. Muraz,
F. Naraghi,
N. Zhou,
J. Busto
Abstract:
Weakly Interacting Massive Particles (WIMPs) are one of the most preferred candidate for Dark Matter. WIMPs should interact with the nuclei of detectors. If a robust signal is eventually observed in direct detection experiments, the best signature to confirm its Galactic origin would be the nuclear recoil track direction. The MIMAC collaboration has developed a low pressure gas detector providing…
▽ More
Weakly Interacting Massive Particles (WIMPs) are one of the most preferred candidate for Dark Matter. WIMPs should interact with the nuclei of detectors. If a robust signal is eventually observed in direct detection experiments, the best signature to confirm its Galactic origin would be the nuclear recoil track direction. The MIMAC collaboration has developed a low pressure gas detector providing both the kinetic energy and three-dimensional track reconstruction of nuclear recoils. In this paper we report the first ever observations of $^{19}$F nuclei tracks in a $5$ cm drift prototype MIMAC detector, in the low kinetic energy range ($6$-$26$ keV), using specially developed ion beam facilities. We have measured the recoil track lengths and found significant differences between our measurements and standard simulations. In order to understand these differences, we have performed a series of complementary experiments and simulations to study the impact of the diffusion and eventual systematics. We show an unexpected dependence of the number of read-out corresponding to the track on the electric field applied to the $512\ \mathrm{μm}$ gap of the Micromegas detector. We have introduced, based on the flash-ADC observable, corrections in order to reconstruct the physical 3D track length of the primary electron clouds proposing the physics behind these corrections. We show that diffusion and space charge effects need to be taken into account to explain the differences between measurements and standard simulations. These measurements and simulations may shed a new light on the high-gain TPC ionization signals in general and particularly at low energy.
△ Less
Submitted 26 March, 2020; v1 submitted 5 March, 2019;
originally announced March 2019.
-
Cathode signal in a TPC directional detector: implementation and validation measuring the drift velocity
Authors:
C. Couturier,
Q. Riffard,
N. Sauzet,
O. Guillaudin,
F. Naraghi,
D. Santos
Abstract:
Low-pressure gaseous TPCs are well suited detectors to correlate the directions of nuclear recoils to the galactic Dark Matter (DM) halo. Indeed, in addition to providing a measure of the energy deposition due to the elastic scattering of a DM particle on a nucleus in the target gas, they allow for the reconstruction of the track of the recoiling nucleus. In order to exclude the background events…
▽ More
Low-pressure gaseous TPCs are well suited detectors to correlate the directions of nuclear recoils to the galactic Dark Matter (DM) halo. Indeed, in addition to providing a measure of the energy deposition due to the elastic scattering of a DM particle on a nucleus in the target gas, they allow for the reconstruction of the track of the recoiling nucleus. In order to exclude the background events originating from radioactive decays on the surfaces of the detector materials within the drift volume, efforts are ongoing to precisely localize the track nuclear recoil in the drift volume along the axis perpendicular to the cathode plane. We report here the implementation of the measure of the signal induced on the cathode by the motion of the primary electrons toward the anode in a MIMAC chamber. As a validation, we performed an independent measurement of the drift velocity of the electrons in the considered gas mixture, correlating in time the cathode signal with the measure of the arrival times of the electrons on the anode.
△ Less
Submitted 20 November, 2017;
originally announced November 2017.
-
Directional detection of Dark Matter with the MIcro-tpc MAtrix of Chambers
Authors:
C. Couturier,
O. Guillaudin,
F. Naraghi,
Q. Riffard,
D. Santos,
N. Sauzet,
P. Colas,
E. Ferrer Ribas,
I. Giomataris,
J. Busto,
D. Fouchez,
C. Tao,
N. Zhou
Abstract:
Particles weakly interacting with ordinary matter, with an associated mass of the order of an atomic nucleus (WIMPs), are plausible candidates for Dark Matter. The direct detection of an elastic collision of a target nuclei induced by one of these WIMPs has to be discriminated from the signal produced by the neutrons, which leaves the same signal in a detector. The MIMAC (MIcro-tpc MAtrix of Chamb…
▽ More
Particles weakly interacting with ordinary matter, with an associated mass of the order of an atomic nucleus (WIMPs), are plausible candidates for Dark Matter. The direct detection of an elastic collision of a target nuclei induced by one of these WIMPs has to be discriminated from the signal produced by the neutrons, which leaves the same signal in a detector. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed an original prototype detector which combines a large pixelated Micromegas coupled with a fast, self-triggering, electronics. Aspects of the two-chamber module in operation in the Modane Underground Laboratory are presented: calibration, characterization of the $^{222}$Rn progeny. A new test bench combining a MIMAC chamber with the COMIMAC portable quenching line has been set up to characterize the 3D tracks of low energy ions in the MIMAC gas mixture: the preliminary results thereof are presented. Future steps are briefly discussed.
△ Less
Submitted 29 July, 2016;
originally announced July 2016.
-
Dark Matter directional detection: comparison of the track direction determination
Authors:
C. Couturier,
J. P. Zopounidis,
N. Sauzet,
F. Naraghi,
D. Santos
Abstract:
Several directional techniques have been proposed for a directional detection of Dark matter, among others anisotropic crystal detectors, nuclear emulsion plates, and low-pressure gaseous TPCs. The key point is to get access to the initial direction of the nucleus recoiling due to the elastic scattering by a WIMP. In this article, we aim at estimating, for each method, how the information of the r…
▽ More
Several directional techniques have been proposed for a directional detection of Dark matter, among others anisotropic crystal detectors, nuclear emulsion plates, and low-pressure gaseous TPCs. The key point is to get access to the initial direction of the nucleus recoiling due to the elastic scattering by a WIMP. In this article, we aim at estimating, for each method, how the information of the recoil track initial direction is preserved in different detector materials. We use the SRIM simulation code to emulate the motion of the first recoiling nucleus in each material. We propose the use of a new observable, D, to quantify the preservation of the initial direction of the recoiling nucleus in the detector. We show that in an emulsion mix and an anisotropic crystal, the initial direction is lost very early, while in a typical TPC gas mix, the direction is well preserved.
△ Less
Submitted 16 January, 2017; v1 submitted 27 July, 2016;
originally announced July 2016.
-
Archeops In-flight Performance, Data Processing and Map Making
Authors:
J. F. Macias-Perez,
G. Lagache,
B. Maffei,
P. Ade,
A. Amblard,
R. Ansari,
E. Aubourg,
J. Aumont,
S. Bargot,
J. Bartlett,
A. Benoit,
J. Ph. Bernard,
R. Bhatia,
A. Blanchard,
J. J. Bock,
A. Boscaleri,
F. R. Bouchet,
A. Bourrachot,
P. Camus,
J. -F. Cardoso,
F. Couchot,
P. de Bernardis,
J. Delabrouille,
F. X. Desert,
O. Doré
, et al. (47 additional authors not shown)
Abstract:
Archeops is a balloon--borne experiment widely inspired by the Planck satellite and by its High Frequency Instrument (HFI). It is mainly dedicated to measure the Cosmic Microwave Background (CMB) temperature anisotropies at high angular resolution (about 12 arcminutes) over a large fraction of the sky (around 30 %) in the millimetre and submillimetre range at 143, 217, 353 and 545 GHz. Further,…
▽ More
Archeops is a balloon--borne experiment widely inspired by the Planck satellite and by its High Frequency Instrument (HFI). It is mainly dedicated to measure the Cosmic Microwave Background (CMB) temperature anisotropies at high angular resolution (about 12 arcminutes) over a large fraction of the sky (around 30 %) in the millimetre and submillimetre range at 143, 217, 353 and 545 GHz. Further, the Archeops 353 GHz channel consists of three pairs of polarized sensitive bolometers designed to detect the polarized diffuse emission of Galactic dust. We present in this paper the update of the instrumental setup as well as the inflight performance for the last Archeops flight campaign in February 2002 from Kiruna (Sweden). We also describe the processing and analysis of the Archeops time ordered data for that campaign which lead to the measurement of the CMB anisotropies power spectrum in the multipole range l=10-700 (Benoit et al. 2003a, Tristram et al. 2005) and to the first measurement of the dust polarized emission at large angular scales and its polarized. We present maps of 30 % of the sky of the Galactic emission, including the Galactic plane, in the four Archeops channels at 143, 217, 353 and 545 GHz and maps of the CMB anisotropies at 143 and 217 GHz. These are the firstever available sub--degree resolution maps in the millimetre and submillimetre range of the large angular-scales Galactic dust diffuse emission and CMB temperature anisotropies respectively.
△ Less
Submitted 24 March, 2006;
originally announced March 2006.
-
Project of a superfluid He3 detector for direct detection of non-baryonic dark matter : MACHe3
Authors:
E. Moulin,
F. Naraghi,
D. Santos,
E. Collin,
C. Winkelmann,
Y. Bunkov,
H. Godfrin
Abstract:
MACHe3 (MAtrix of Cells of superfluid Helium 3) is a project of non-baryonic Dark Matter search using superfluid He3 as sensitive medium. Simulations on a high granularity matrix show very good rejection against background events. First results on a prototype cell are very encouraging. Neutron detection has been highlighted as well as cosmic muon detection. A phenomenological study has been done…
▽ More
MACHe3 (MAtrix of Cells of superfluid Helium 3) is a project of non-baryonic Dark Matter search using superfluid He3 as sensitive medium. Simulations on a high granularity matrix show very good rejection against background events. First results on a prototype cell are very encouraging. Neutron detection has been highlighted as well as cosmic muon detection. A phenomenological study has been done with the DarkSUSY code to investigate complementarity of MACHe3 with existing Dark Matter detectors.
△ Less
Submitted 11 September, 2003;
originally announced September 2003.
-
First Detection of Polarization of the Submillimetre Diffuse Galactic Dust Emission by Archeops
Authors:
A. Benoit,
P. Ade,
A. Amblard,
R. Ansari,
E. Aubourg,
S. Bargot,
J. G. Bartlett,
J. -Ph. Bernard,
R. S. Bhatia,
A. Blanchard,
J. J. Bock,
A. Boscaleri,
F. R. Bouchet,
A. Bourrachot,
P. Camus,
F. Couchot,
P. de Bernardis,
J. Delabrouille,
F. -X. Desert,
O. Doré,
M. Douspis,
L. Dumoulin,
X. Dupac,
P. Filliatre,
P. Fosalba
, et al. (43 additional authors not shown)
Abstract:
We present the first determination of the Galactic polarized emission at 353 GHz by Archeops. The data were taken during the Arctic night of February 7, 2002 after the balloon--borne instrument was launched by CNES from the Swedish Esrange base near Kiruna. In addition to the 143 GHz and 217 GHz frequency bands dedicated to CMB studies, Archeops had one 545 GHz and six 353 GHz bolometers mounted…
▽ More
We present the first determination of the Galactic polarized emission at 353 GHz by Archeops. The data were taken during the Arctic night of February 7, 2002 after the balloon--borne instrument was launched by CNES from the Swedish Esrange base near Kiruna. In addition to the 143 GHz and 217 GHz frequency bands dedicated to CMB studies, Archeops had one 545 GHz and six 353 GHz bolometers mounted in three polarization sensitive pairs that were used for Galactic foreground studies. We present maps of the I, Q, U Stokes parameters over 17% of the sky and with a 13 arcmin resolution at 353 GHz (850 microns). They show a significant Galactic large scale polarized emission coherent on the longitude ranges [100, 120] and [180, 200] deg. with a degree of polarization at the level of 4-5%, in agreement with expectations from starlight polarization measurements. Some regions in the Galactic plane (Gem OB1, Cassiopeia) show an even stronger degree of polarization in the range 10-20%. Those findings provide strong evidence for a powerful grain alignment mechanism throughout the interstellar medium and a coherent magnetic field coplanar to the Galactic plane. This magnetic field pervades even some dense clouds. Extrapolated to high Galactic latitude, these results indicate that interstellar dust polarized emission is the major foreground for PLANCK-HFI CMB polarization measurement.
△ Less
Submitted 11 June, 2003;
originally announced June 2003.
-
Cosmological constraints from Archeops
Authors:
A. Benoit,
P. Ade,
A. Amblard,
R. Ansari,
E. Aubourg,
S. Bargot,
J. G. Bartlett,
J. -Ph. Bernard,
R. S. Bhatia,
A. Blanchard,
J. J. Bock,
A. Boscaleri,
F. R. Bouchet,
A. Bourrachot,
P. Camus,
F. Couchot,
P. de Bernardis,
J. Delabrouille,
F. -X. Desert,
O. Doré,
M. Douspis,
L. Dumoulin,
X. Dupac,
P. Filliatre,
P. Fosalba
, et al. (43 additional authors not shown)
Abstract:
We analyze the cosmological constraints that Archeops places on adiabatic cold dark matter models with passive power-law initial fluctuations. Because its angular power spectrum has small bins in l and large l coverage down to COBE scales, Archeops provides a precise determination of the first acoustic peak in terms of position at multipole l_peak=220 +- 6, height and width. An analysis of Arche…
▽ More
We analyze the cosmological constraints that Archeops places on adiabatic cold dark matter models with passive power-law initial fluctuations. Because its angular power spectrum has small bins in l and large l coverage down to COBE scales, Archeops provides a precise determination of the first acoustic peak in terms of position at multipole l_peak=220 +- 6, height and width. An analysis of Archeops data in combination with other CMB datasets constrains the baryon content of the Universe, Omega(b)h^2 = 0.022 (+0.003,-0.004), compatible with Big-Bang nucleosynthesis and with a similar accuracy. Using cosmological priors obtainedfrom recent non-CMB data leads to yet tighter constraints on the total density, e.g. Omega(tot)=1.00 (+0.03,-0.02) using the HST determination of the Hubble constant. An excellent absolute calibration consistency is found between Archeops and other CMB experiments, as well as with the previously quoted best fit model.The spectral index n is measured to be 1.04 (+0.10,-0.12) when the optical depth to reionization, tau, is allowed to vary as a free parameter, and 0.96 (+0.03,-0.04) when tau is fixed to zero, both in good agreement with inflation.
△ Less
Submitted 22 January, 2003; v1 submitted 14 October, 2002;
originally announced October 2002.
-
The Cosmic Microwave Background Anisotropy Power Spectrum measured by Archeops
Authors:
A. Benoit,
P. Ade,
A. Amblard,
R. Ansari,
E. Aubourg,
S. Bargot,
J. G. Bartlett,
J. -Ph. Bernard,
R. S. Bhatia,
A. Blanchard,
J. J. Bock,
A. Boscaleri,
F. R. Bouchet,
A. Bourrachot,
P. Camus,
F. Couchot,
P. de Bernardis,
J. Delabrouille,
F. -X. Desert,
O. Doré,
M. Douspis,
L. Dumoulin,
X. Dupac,
P. Filliatre,
P. Fosalba
, et al. (43 additional authors not shown)
Abstract:
We present a determination by the Archeops experiment of the angular power spectrum of the cosmic microwave background anisotropy in 16 bins over the multipole range l=15-350. Archeops was conceived as a precursor of the Planck HFI instrument by using the same optical design and the same technology for the detectors and their cooling. Archeops is a balloon-borne instrument consisting of a 1.5 m…
▽ More
We present a determination by the Archeops experiment of the angular power spectrum of the cosmic microwave background anisotropy in 16 bins over the multipole range l=15-350. Archeops was conceived as a precursor of the Planck HFI instrument by using the same optical design and the same technology for the detectors and their cooling. Archeops is a balloon-borne instrument consisting of a 1.5 m aperture diameter telescope and an array of 21 photometers maintained at ~100 mK that are operating in 4 frequency bands centered at 143, 217, 353 and 545 GHz. The data were taken during the Arctic night of February 7, 2002 after the instrument was launched by CNES from Esrange base (Sweden). The entire data cover ~ 30% of the sky.This first analysis was obtained with a small subset of the dataset using the most sensitive photometer in each CMB band (143 and 217 GHz) and 12.6% of the sky at galactic latitudes above 30 degrees where the foreground contamination is measured to be negligible. The large sky coverage and medium resolution (better than 15 arcminutes) provide for the first time a high signal-to-noise ratio determination of the power spectrum over angular scales that include both the first acoustic peak and scales probed by COBE/DMR. With a binning of Delta(l)=7 to 25 the error bars are dominated by sample variance for l below 200. A companion paper details the cosmological implications.
△ Less
Submitted 22 January, 2003; v1 submitted 14 October, 2002;
originally announced October 2002.
-
A superfluid He3 detector for direct dark matter search
Authors:
F. Mayet,
D. Santos,
Yu. M. Bunkov,
G. Duhamel,
H. Godfrin,
F. Naraghi,
G. Perrin
Abstract:
MACHe3 (MAtrix of Cells of superfluid He3) is a project of a new detector for direct Dark Matter Search. The idea is to use superfluid He3 as a sensitive medium. The existing device, the superfluid He3 cell, will be briefly introduced. Then a description of the MACHe3 project will be presented, in particular the background rejection and the neutralino event rate that may be achieved with such a…
▽ More
MACHe3 (MAtrix of Cells of superfluid He3) is a project of a new detector for direct Dark Matter Search. The idea is to use superfluid He3 as a sensitive medium. The existing device, the superfluid He3 cell, will be briefly introduced. Then a description of the MACHe3 project will be presented, in particular the background rejection and the neutralino event rate that may be achieved with such a device.
△ Less
Submitted 15 November, 2000;
originally announced November 2000.
-
A project of a new detector for direct Dark Matter search: MACHe3
Authors:
D. Santos,
F. Mayet,
Yu. M. Bunkov,
A. Drezet,
G. Duhamel,
H. Godfrin,
F. Naraghi,
G. Perrin
Abstract:
MACHe3 (MAtrix of Cells of superfluid He3) is a project of a new detector for direct Dark Matter (DM) search. A cell of superfluid He3 has been developed and the idea of using a large number of such cells in a high granularity detector is proposed.This contribution presents, after a brief description of the superfluid He3 cell, the simulation of the response of different matrix configurations al…
▽ More
MACHe3 (MAtrix of Cells of superfluid He3) is a project of a new detector for direct Dark Matter (DM) search. A cell of superfluid He3 has been developed and the idea of using a large number of such cells in a high granularity detector is proposed.This contribution presents, after a brief description of the superfluid He3 cell, the simulation of the response of different matrix configurations allowing to define an optimum design as a function of the number of cells and the volume of each cell. The exclusion plot and the predicted interaction cross-section for the neutralino as a photino are presented.
△ Less
Submitted 16 May, 2000;
originally announced May 2000.