-
Impact of particles on the Planck HFI detectors: Ground-based measurements and physical interpretation
Authors:
A. Catalano,
P. Ade,
Y. Atik,
A. Benoit,
E. Bréele,
J. J. Bock,
P. Camus,
M. Chabot,
M. Charra,
B. P. Crill,
N. Coron,
A. Coulais,
F. -X. Désert,
L. Fauvet,
Y. Giraud-Héraud,
O. Guillaudin,
W. Holmes,
W. C. Jones,
J. -M. Lamarre,
J. Macías-Pérez,
M. Martinez,
A. Miniussi,
A. Monfardini,
F. Pajot,
G. Patanchon
, et al. (9 additional authors not shown)
Abstract:
The Planck High Frequency Instrument (HFI) surveyed the sky continuously from August 2009 to January 2012. Its noise and sensitivity performance were excellent, but the rate of cosmic ray impacts on the HFI detectors was unexpectedly high. Furthermore, collisions of cosmic rays with the focal plane produced transient signals in the data (glitches) with a wide range of characteristics. A study of c…
▽ More
The Planck High Frequency Instrument (HFI) surveyed the sky continuously from August 2009 to January 2012. Its noise and sensitivity performance were excellent, but the rate of cosmic ray impacts on the HFI detectors was unexpectedly high. Furthermore, collisions of cosmic rays with the focal plane produced transient signals in the data (glitches) with a wide range of characteristics. A study of cosmic ray impacts on the HFI detector modules has been undertaken to categorize and characterize the glitches, to correct the HFI time-ordered data, and understand the residual effects on Planck maps and data products. This paper presents an evaluation of the physical origins of glitches observed by the HFI detectors. In order to better understand the glitches observed by HFI in flight, several ground-based experiments were conducted with flight-spare HFI bolometer modules. The experiments were conducted between 2010 and 2013 with HFI test bolometers in different configurations using varying particles and impact energies. The bolometer modules were exposed to 23 MeV protons from the Orsay IPN TANDEM accelerator, and to $^{241}$Am and $^{244}$Cm $α$-particle and $^{55}$Fe radioactive X-ray sources. The calibration data from the HFI ground-based preflight tests were used to further characterize the glitches and compare glitch rates with statistical expectations under laboratory conditions. Test results provide strong evidence that the dominant family of glitches observed in flight are due to cosmic ray absorption by the silicon die substrate on which the HFI detectors reside. Glitch energy is propagated to the thermistor by ballistic phonons, while there is also a thermal diffusion contribution. The implications of these results for future satellite missions, especially those in the far-infrared to sub-millimetre and millimetre regions of the electromagnetic spectrum, are discussed.
△ Less
Submitted 2 September, 2014; v1 submitted 26 March, 2014;
originally announced March 2014.
-
Characterization and Physical Explanation of Energetic Particles on Planck HFI Instrument
Authors:
A. Catalano,
P. Ade,
Y. Atik,
A. Benoit,
E. Bréele,
J. J. Bock,
P. Camus,
M. Charra,
B. P. Crill,
N. Coron,
A. Coulais,
F. -X. Désert,
L. Fauvet,
Y. Giraud-Héraud,
O. Guillaudin,
W. Holmes,
W. C. Jones,
J. -M. Lamarre,
J. Macías-Pérez,
M. Martinez,
A. Miniussi,
A. Monfardini,
F. Pajot,
G. Patanchon,
A. Pelissier
, et al. (8 additional authors not shown)
Abstract:
The Planck High Frequency Instrument (HFI) has been surveying the sky continuously from the second Lagrangian point (L2) between August 2009 and January 2012. It operates with 52 high impedance bolometers cooled at 100mK in a range of frequency between 100 GHz and 1THz with unprecedented sensivity, but strong coupling with cosmic radiation. At L2, the particle flux is about 5 $cm^{-2} s^{-1}$ and…
▽ More
The Planck High Frequency Instrument (HFI) has been surveying the sky continuously from the second Lagrangian point (L2) between August 2009 and January 2012. It operates with 52 high impedance bolometers cooled at 100mK in a range of frequency between 100 GHz and 1THz with unprecedented sensivity, but strong coupling with cosmic radiation. At L2, the particle flux is about 5 $cm^{-2} s^{-1}$ and is dominated by protons incident on the spacecraft. Protons with an energy above 40MeV can penetrate the focal plane unit box causing two different effects: glitches in the raw data from direct interaction of cosmic rays with detectors (producing a data loss of about 15% at the end of the mission) and thermal drifts in the bolometer plate at 100mK adding non-gaussian noise at frequencies below 0.1Hz. The HFI consortium has made strong efforts in order to correct for this effect on the time ordered data and final Planck maps. This work intends to give a view of the physical explanation of the glitches observed in the HFI instrument in-flight. To reach this goal, we performed several ground-based experiments using protons and $α$ particles to test the impact of particles on the HFI spare bolometers with a better control of the environmental conditions with respect to the in-flight data. We have shown that the dominant part of glitches observed in the data comes from the impact of cosmic rays in the silicon die frame supporting the micro-machinced bolometric detectors propagating energy mainly by ballistic phonons and by thermal diffusion. The implications of these results for future satellite missions will be discussed.
△ Less
Submitted 22 March, 2014;
originally announced March 2014.
-
Design and construction of a Cherenkov imager for charge measurement of nuclear cosmic rays
Authors:
O. Bourrion,
Ch. Bernard,
D. Bondoux,
J. L. Bouly,
J. Bouvier,
B. Boyer,
M. Brinet,
M. Buenerd,
G. Damieux,
L. Derome,
L. Eraud,
R. Foglio,
D. Fombaron,
D. Grondin,
M. H. Lee,
L. Lutz,
M. Marton,
A. Menchaca-Rocha,
A. Pelissier,
J. N. Périé,
A. Putze,
S. Roudier,
Y. Sallaz-Damaz,
E. S. Seo,
J. P. Scordilis
, et al. (1 additional authors not shown)
Abstract:
A proximity focusing Cherenkov imager called CHERCAM, has been built for the charge measurement of nuclear cosmic rays with the CREAM instrument. It consists of a silica aerogel radiator plane across from a detector plane equipped with 1,600 1" diameter photomultipliers. The two planes are separated by a ring expansion gap. The Cherenkov light yield is proportional to the charge squared of the inc…
▽ More
A proximity focusing Cherenkov imager called CHERCAM, has been built for the charge measurement of nuclear cosmic rays with the CREAM instrument. It consists of a silica aerogel radiator plane across from a detector plane equipped with 1,600 1" diameter photomultipliers. The two planes are separated by a ring expansion gap. The Cherenkov light yield is proportional to the charge squared of the incident particle. The expected relative light collection accuracy is in the few percents range. It leads to an expected single element separation over the range of nuclear charge Z of main interest 1 < Z < 26. CHERCAM is designed to fly with the CREAM balloon experiment. The design of the instrument and the implemented technical solutions allowing its safe operation in high altitude conditions (radiations, low pressure, cold) are presented.
△ Less
Submitted 18 May, 2011; v1 submitted 7 March, 2011;
originally announced March 2011.