Skipper-in-CMOS: Non-Destructive Readout with Sub-Electron Noise Performance for Pixel Detectors
Authors:
Agustin J. Lapi,
Miguel Sofo-Haro,
Benjamin C. Parpillon,
Adi Birman,
Guillermo Fernandez-Moroni,
Lorenzo Rota,
Fabricio Alcalde Bessia,
Aseem Gupta,
Claudio Chavez Blanco,
Fernando Chierchie,
Julie Segal,
Christopher J. Kenney,
Angelo Dragone,
Shaorui Li,
Davide Braga,
Amos Fenigstein,
Juan Estrada,
Farah Fahim
Abstract:
The Skipper-in-CMOS image sensor integrates the non-destructive readout capability of Skipper Charge Coupled Devices (Skipper-CCDs) with the high conversion gain of a pinned photodiode in a CMOS imaging process, while taking advantage of in-pixel signal processing. This allows both single photon counting as well as high frame rate readout through highly parallel processing. The first results obtai…
▽ More
The Skipper-in-CMOS image sensor integrates the non-destructive readout capability of Skipper Charge Coupled Devices (Skipper-CCDs) with the high conversion gain of a pinned photodiode in a CMOS imaging process, while taking advantage of in-pixel signal processing. This allows both single photon counting as well as high frame rate readout through highly parallel processing. The first results obtained from a 15 x 15 um^2 pixel cell of a Skipper-in-CMOS sensor fabricated in Tower Semiconductor's commercial 180 nm CMOS Image Sensor process are presented. Measurements confirm the expected reduction of the readout noise with the number of samples down to deep sub-electron noise of 0.15rms e-, demonstrating the charge transfer operation from the pinned photodiode and the single photon counting operation when the sensor is exposed to light. The article also discusses new testing strategies employed for its operation and characterization.
△ Less
Submitted 19 February, 2024;
originally announced February 2024.
-
SENSEI: First Direct-Detection Results on sub-GeV Dark Matter from SENSEI at SNOLAB
Authors:
SENSEI Collaboration,
Prakruth Adari,
Itay M. Bloch,
Ana M. Botti,
Mariano Cababie,
Gustavo Cancelo,
Brenda A. Cervantes-Vergara,
Michael Crisler,
Miguel Daal,
Ansh Desai,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Erez Etzion,
Guillermo Fernandez Moroni,
Stephen E. Holland,
Yonatan Kehat,
Yaron Korn,
Ian Lawson,
Steffon Luoma,
Aviv Orly,
Santiago E. Perez,
Dario Rodrigues,
Nathan A. Saffold,
Silvia Scorza
, et al. (12 additional authors not shown)
Abstract:
We present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. With an exposure of 534.9 gram-days from well-performing sensors, we select events containing 2 to 10 electron-hole pairs. After aggressively masking images to remove backgrounds, we observe 55 two-electron events, 4 three-electron events, and no events containing 4 to 10 elect…
▽ More
We present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. With an exposure of 534.9 gram-days from well-performing sensors, we select events containing 2 to 10 electron-hole pairs. After aggressively masking images to remove backgrounds, we observe 55 two-electron events, 4 three-electron events, and no events containing 4 to 10 electrons. The two-electron events are consistent with pileup from one-electron events. Among the 4 three-electron events, 2 appear in pixels that are likely impacted by detector defects, although not strongly enough to trigger our "hot-pixel" mask. We use these data to set world-leading constraints on sub-GeV dark matter interacting with electrons and nuclei.
△ Less
Submitted 20 December, 2023;
originally announced December 2023.
-
Achieving Single-Electron Sensitivity at Enhanced Speed in Fully-Depleted CCDs with Double-Gate MOSFETs
Authors:
Miguel Sofo-Haro,
Kevan Donlon,
Juan Estrada,
Steve Holland,
Farah Fahim,
Chris Leitz
Abstract:
We introduce a new output amplifier for fully-depleted thick p-channel CCDs based on double-gate MOSFETs. The charge amplifier is an n-type MOSFET specifically designed and operated to couple the fully-depleted CCD with high charge-transfer efficiency. The junction coupling between the CCD and MOSFET channels has enabled high sensitivity, demonstrating sub-electron readout noise in one pixel charg…
▽ More
We introduce a new output amplifier for fully-depleted thick p-channel CCDs based on double-gate MOSFETs. The charge amplifier is an n-type MOSFET specifically designed and operated to couple the fully-depleted CCD with high charge-transfer efficiency. The junction coupling between the CCD and MOSFET channels has enabled high sensitivity, demonstrating sub-electron readout noise in one pixel charge measurement. We have also demonstrated the non-destructive readout capability of the device. Achieving single-electron and single-photon per pixel counting in the entire CCD pixel array has been made possible through the averaging of a small number of samples. We have demonstrated fully-depleted CCD readout with better performance than the floating diffusion and floating gate amplifiers available today, in both single and multisampling regimes, boasting at least six times the speed of floating gate amplifiers.
△ Less
Submitted 20 October, 2023;
originally announced October 2023.
-
Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs
Authors:
A. Aguilar-Arevalo,
I. Arnquist,
N. Avalos,
L. Barak,
D. Baxter,
X. Bertou,
I. M. Bloch,
A. M. Botti,
M. Cababie,
G. Cancelo,
N. Castelló-Mor,
B. A. Cervantes-Vergara,
A. E. Chavarria,
J. Cortabitarte-Gutiérrez,
M. Crisler,
J. Cuevas-Zepeda,
A. Dastgheibi-Fard,
C. De Dominicis,
O. Deligny,
A. Drlica-Wagner,
J. Duarte-Campderros,
J. C. D'Olivo,
R. Essig,
E. Estrada,
J. Estrada
, et al. (47 additional authors not shown)
Abstract:
We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. W…
▽ More
We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ${\sim}7$ events per kg-day and electron-equivalent energies of ${\sim}80~$eV, whose origin remains unknown.
△ Less
Submitted 26 March, 2024; v1 submitted 2 June, 2023;
originally announced June 2023.
-
Skipper-CCDs: current applications and future
Authors:
B. A. Cervantes-Vergara,
S. Perez,
J. C. D'Olivo,
J. Estrada,
D. J. Grimm,
S. Holland,
M. Sofo-Haro,
W. Wong
Abstract:
This work briefly discusses the potential applications of the Skipper-CCD technology in astronomy and reviews its current use in dark matter and neutrino experiments. An overview of the ongoing efforts to build multi-kilogram experiments with these sensors is given, in the context of the Oscura experiment. First results from the characterization of Oscura sensors from the first 200 mm wafer-fabric…
▽ More
This work briefly discusses the potential applications of the Skipper-CCD technology in astronomy and reviews its current use in dark matter and neutrino experiments. An overview of the ongoing efforts to build multi-kilogram experiments with these sensors is given, in the context of the Oscura experiment. First results from the characterization of Oscura sensors from the first 200 mm wafer-fabrication run with a new vendor are presented. The overall yield of the electron counting capability of these sensors is 71%. A noise of 0.087 e$^-$ RMS, with 1225 samples/pix, and a dark current of (0.031$\pm$0.013) e$^-$/pix/day at 140 K were measured.
△ Less
Submitted 10 August, 2022;
originally announced August 2022.
-
The Oscura Experiment
Authors:
Alexis Aguilar-Arevalo,
Fabricio Alcalde Bessia,
Nicolas Avalos,
Daniel Baxter,
Xavier Bertou,
Carla Bonifazi,
Ana Botti,
Mariano Cababie,
Gustavo Cancelo,
Brenda Aurea Cervantes-Vergara,
Nuria Castello-Mor,
Alvaro Chavarria,
Claudio R. Chavez,
Fernando Chierchie,
Juan Manuel De Egea,
Juan Carlos D`Olivo,
Cyrus E. Dreyer,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Ezequiel Estrada,
Erez Etzion,
Guillermo Fernandez-Moroni,
Marivi Fernandez-Serra,
Steve Holland
, et al. (19 additional authors not shown)
Abstract:
The Oscura experiment will lead the search for low-mass dark matter particles using a very large array of novel silicon Charge Coupled Devices (CCDs) with a threshold of two electrons and with a total exposure of 30 kg-yr. The R&D effort, which began in FY20, is currently entering the design phase with the goal of being ready to start construction in late 2024. Oscura will have unprecedented sensi…
▽ More
The Oscura experiment will lead the search for low-mass dark matter particles using a very large array of novel silicon Charge Coupled Devices (CCDs) with a threshold of two electrons and with a total exposure of 30 kg-yr. The R&D effort, which began in FY20, is currently entering the design phase with the goal of being ready to start construction in late 2024. Oscura will have unprecedented sensitivity to sub-GeV dark matter particles that interact with electrons, probing dark matter-electron scattering for masses down to 500 keV and dark matter being absorbed by electrons for masses down to 1 eV. The Oscura R&D effort has made some significant progress on the main technical challenges of the experiment, of which the most significant are engaging new foundries for the fabrication of the CCD sensors, developing a cold readout solution, and understanding the experimental backgrounds.
△ Less
Submitted 23 February, 2022; v1 submitted 21 February, 2022;
originally announced February 2022.
-
Single-electron and single-photon sensitivity with a silicon Skipper CCD
Authors:
Javier Tiffenberg,
Miguel Sofo-Haro,
Alex Drlica-Wagner,
Rouven Essig,
Yann Guardincerri,
Steve Holland,
Tomer Volansky,
Tien-Tien Yu
Abstract:
We have developed a non-destructive readout system that uses a floating-gate amplifier on a thick, fully depleted charge coupled device (CCD) to achieve ultra-low readout noise of 0.068 e- rms/pix. This is the first time that discrete sub-electron readout noise has been achieved reproducibly over millions of pixels on a stable, large-area detector. This allows the precise counting of the number of…
▽ More
We have developed a non-destructive readout system that uses a floating-gate amplifier on a thick, fully depleted charge coupled device (CCD) to achieve ultra-low readout noise of 0.068 e- rms/pix. This is the first time that discrete sub-electron readout noise has been achieved reproducibly over millions of pixels on a stable, large-area detector. This allows the precise counting of the number of electrons in each pixel, ranging from pixels with 0 electrons to more than 1500 electrons. The resulting CCD detector is thus an ultra-sensitive calorimeter. It is also capable of counting single photons in the optical and near-infrared regime. Implementing this innovative non-destructive readout system has a negligible impact on CCD design and fabrication, and there are nearly immediate scientific applications. As a particle detector, this CCD will have unprecedented sensitivity to low-mass dark matter particles and coherent neutrino-nucleus scattering, while astronomical applications include future direct imaging and spectroscopy of exoplanets.
△ Less
Submitted 31 May, 2017;
originally announced June 2017.