-
Single Aperture Large Telescope for Universe Studies (SALTUS): Science Overview
Authors:
Gordon Chin,
Carrie M. Anderson,
Jennifer Bergner,
Nicolas Biver,
Gordon L. Bjoraker,
Thibault Cavalie,
Michael DiSanti,
Jian-Rong Gao,
Paul Hartogh,
Leon K. Harding,
Qing Hu,
Daewook Kim,
Craig Kulesa,
Gert de Lange,
David T. Leisawitz,
Rebecca C. Levy,
Arthur Lichtenberger,
Daniel P. Marronh,
Joan Najita,
Trent Newswander,
George H. Rieke,
Dimitra Rigopoulou,
Peter Roefsema,
Nathan X. Roth,
Kamber Schwarz
, et al. (11 additional authors not shown)
Abstract:
The SALTUS Probe mission will provide a powerful far-infrared (far-IR) pointed space observatory to explore our cosmic origins and the possibility of life elsewhere. The observatory employs an innovative deployable 14-m aperture, with a sunshield that will radiatively cool the off-axis primary to <45K. This cooled primary reflector works in tandem with cryogenic coherent and incoherent instruments…
▽ More
The SALTUS Probe mission will provide a powerful far-infrared (far-IR) pointed space observatory to explore our cosmic origins and the possibility of life elsewhere. The observatory employs an innovative deployable 14-m aperture, with a sunshield that will radiatively cool the off-axis primary to <45K. This cooled primary reflector works in tandem with cryogenic coherent and incoherent instruments that span the 34 to 660 micron far-IR range at both high and moderate spectral resolutions.
△ Less
Submitted 21 May, 2024;
originally announced May 2024.
-
Optimisation-based alignment of wideband integrated superconducting spectrometers for sub-mm astronomy
Authors:
A. Moerman,
K. Karatsu,
S. J. C. Yates,
R. Huiting,
F. Steenvoorde,
S. O. Dabironezare,
T. Takekoshi,
J. J. A. Baselmans,
B. R. Brandl,
A. Endo
Abstract:
Integrated superconducting spectrometers (ISSs) for wideband sub-mm astronomy utilise quasi-optical systems for coupling radiation from the telescope to the instrument. Misalignment in these systems is detrimental to the system performance. The common method of using an optical laser to align the quasi-optical components requires accurate alignment of the laser to the sub-mm beam coming from the i…
▽ More
Integrated superconducting spectrometers (ISSs) for wideband sub-mm astronomy utilise quasi-optical systems for coupling radiation from the telescope to the instrument. Misalignment in these systems is detrimental to the system performance. The common method of using an optical laser to align the quasi-optical components requires accurate alignment of the laser to the sub-mm beam coming from the instrument, which is not always guaranteed to a sufficient accuracy. We develop an alignment strategy for wideband ISSs directly utilising the sub-mm beam of the wideband ISS. The strategy should be applicable in both telescope and laboratory environments. Moreover, the strategy should deliver similar quality of the alignment across the spectral range of the wideband ISS. We measure misalignment in a quasi-optical system operating at sub-mm wavelengths using a novel phase and amplitude measurement scheme, capable of simultaneously measuring the complex beam patterns of a direct-detecting ISS across a harmonic range of frequencies. The direct detection nature of the MKID detectors in our device-under-test, DESHIMA 2.0, necessitates the use of this measurement scheme. Using geometrical optics, the measured misalignment, a mechanical hexapod, and an optimisation algorithm, we follow a numerical approach to optimise the positioning of corrective optics with respect to a given cost function. Laboratory measurements of the complex beam patterns are taken across a harmonic range between 205 and 391 GHz and simulated through a model of the ASTE telescope in order to assess the performance of the optimisation at the ASTE telescope. Laboratory measurements show that the optimised optical setup corrects for tilts and offsets of the sub-mm beam. Moreover, we find that the simulated telescope aperture efficiency is increased across the frequency range of the ISS after the optimisation.
△ Less
Submitted 23 February, 2024;
originally announced February 2024.
-
A MKID-readout based on a heterogeneous, closely coupled architecture
Authors:
Gerrit Grutzeck,
Ingo Krämer,
Miroslaw Ciechanowicz,
Nicolas Reyes,
Carsten König,
Andrey Baryshev,
Stephen Yates,
Bernd Klein
Abstract:
Within this proceeding, we introduce the U-Board platform, a versatile platform for signal generation, acquisition and processing, based on a heterogenous processing architecture. Based on this platform we present a readout for Microwave Kinetic Inductance Detectors (MKIDs) for the A-MKID camera for APEX. In addition to the implementation of the readout on this heterogenous architecture, we also p…
▽ More
Within this proceeding, we introduce the U-Board platform, a versatile platform for signal generation, acquisition and processing, based on a heterogenous processing architecture. Based on this platform we present a readout for Microwave Kinetic Inductance Detectors (MKIDs) for the A-MKID camera for APEX. In addition to the implementation of the readout on this heterogenous architecture, we also present a first comparison of the performance of the readout compared to the currently used readout of the A-MKID camera. Last but not least, we discuss how we plan to miniaturize the current prototype, which is based on commercial off the shelf components.
△ Less
Submitted 9 October, 2023;
originally announced October 2023.
-
Applying Energy Absorption Interferometry to THz direct detectors using photomixers
Authors:
Ian Veenendaal,
Edgar Castillo-Dominguez,
Stephen J. C. Yates,
Bram Lap,
Willem Jellema
Abstract:
Detector requirements for far infrared astronomy generally result in devices which exhibit a few-moded response to incident radiation. The sensitivity and spatial form of the individual modes to which such a detector is sensitive can be determined with knowledge of the complex valued cross-spectral density of the system, which we label the detector response function (DRF). A matrix representing th…
▽ More
Detector requirements for far infrared astronomy generally result in devices which exhibit a few-moded response to incident radiation. The sensitivity and spatial form of the individual modes to which such a detector is sensitive can be determined with knowledge of the complex valued cross-spectral density of the system, which we label the detector response function (DRF). A matrix representing the discretized cross-spectral density can be measured from the complex amplitudes of interference fringes generated by two identical sources as they are independently scanned through the field of view. We provide experimental verification of this technique using monochromatic THz beams generated by photomixers in which the relative phase is varied with fiber stretchers. We use this system to characterize the modal response of a single pixel from an array of microwave kinetic inductance detectors (MKIDs).
△ Less
Submitted 26 September, 2023;
originally announced September 2023.
-
DESHIMA 2.0: development of an integrated superconducting spectrometer for science-grade astronomical observations
Authors:
Akio Taniguchi,
Tom J. L. C. Bakx,
Jochem J. A. Baselmans,
Robert Huiting,
Kenichi Karatsu,
Nuria Llombart,
Matus Rybak,
Tatsuya Takekoshi,
Yoichi Tamura,
Hiroki Akamatsu,
Stefanie Brackenhoff,
Juan Bueno,
Bruno T. Buijtendorp,
Shahab Dabironezare,
Anne-Kee Doing,
Yasunori Fujii,
Kazuyuki Fujita,
Matthijs Gouwerok,
Sebastian Hähnle,
Tsuyoshi Ishida,
Shun Ishii,
Ryohei Kawabe,
Tetsu Kitayama,
Kotaro Kohno,
Akira Kouchi
, et al. (10 additional authors not shown)
Abstract:
Integrated superconducting spectrometer (ISS) technology will enable ultra-wideband, integral-field spectroscopy for (sub)millimeter-wave astronomy, in particular, for uncovering the dust-obscured cosmic star formation and galaxy evolution over cosmic time. Here we present the development of DESHIMA 2.0, an ISS for ultra-wideband spectroscopy toward high-redshift galaxies. DESHIMA 2.0 is designed…
▽ More
Integrated superconducting spectrometer (ISS) technology will enable ultra-wideband, integral-field spectroscopy for (sub)millimeter-wave astronomy, in particular, for uncovering the dust-obscured cosmic star formation and galaxy evolution over cosmic time. Here we present the development of DESHIMA 2.0, an ISS for ultra-wideband spectroscopy toward high-redshift galaxies. DESHIMA 2.0 is designed to observe the 220-440 GHz band in a single shot, corresponding to a redshift range of $z$=3.3-7.6 for the ionized carbon emission ([C II] 158 $μ$m). The first-light experiment of DESHIMA 1.0, using the 332-377 GHz band, has shown an excellent agreement among the on-sky measurements, the lab measurements, and the design. As a successor to DESHIMA 1.0, we plan the commissioning and the scientific observation campaign of DESHIMA 2.0 on the ASTE 10-m telescope in 2023. Ongoing upgrades for the full octave-bandwidth system include the wideband 347-channel chip design and the wideband quasi-optical system. For efficient measurements, we also develop the observation strategy using the mechanical fast sky-position chopper and the sky-noise removal technique based on a novel data-scientific approach. In the paper, we show the recent status of the upgrades and the plans for the scientific observation campaign.
△ Less
Submitted 4 October, 2022; v1 submitted 27 October, 2021;
originally announced October 2021.
-
TiEMPO: Open-source time-dependent end-to-end model for simulating ground-based submillimeter astronomical observations
Authors:
Esmee Huijten,
Yannick Roelvink,
Stefanie A. Brackenhoff,
Akio Taniguchi,
Tom J. L. C. Bakx,
Kaushal B. Marthi,
Stan Zaalberg,
Jochem J. A. Baselmans,
Kah Wuy Chin,
Robert Huiting,
Kenichi Karatsu,
Alejandro Pascual Laguna,
Yoichi Tamura,
Tatsuya Takekoshi,
Stephen Yates,
Maarten van Hoven,
Akira Endo
Abstract:
The next technological breakthrough in millimeter-submillimeter astronomy is 3D imaging spectrometry with wide instantaneous spectral bandwidths and wide fields of view. The total optimization of the focal-plane instrument, the telescope, the observing strategy, and the signal-processing software must enable efficient removal of foreground emission from the Earth's atmosphere, which is time-depend…
▽ More
The next technological breakthrough in millimeter-submillimeter astronomy is 3D imaging spectrometry with wide instantaneous spectral bandwidths and wide fields of view. The total optimization of the focal-plane instrument, the telescope, the observing strategy, and the signal-processing software must enable efficient removal of foreground emission from the Earth's atmosphere, which is time-dependent and highly nonlinear in frequency. Here we present TiEMPO: Time-Dependent End-to-End Model for Post-process Optimization of the DESHIMA Spectrometer. TiEMPO utilizes a dynamical model of the atmosphere and parametrized models of the astronomical source, the telescope, the instrument, and the detector. The output of TiEMPO is a time-stream of sky brightness temperature and detected power, which can be analyzed by standard signal-processing software. We first compare TiEMPO simulations with an on-sky measurement by the wideband DESHIMA spectrometer and find good agreement in the noise power spectral density and sensitivity. We then use TiEMPO to simulate the detection of a line emission spectrum of a high-redshift galaxy using the DESHIMA 2.0 spectrometer in development. The TiEMPO model is open source. Its modular and parametrized design enables users to adapt it to design and optimize the end-to-end performance of spectroscopic and photometric instruments on existing and future telescopes.
△ Less
Submitted 8 January, 2021;
originally announced January 2021.
-
Complex beam mapping and Fourier optics analysis of a wide field Microwave Kinetic Inductance Detector camera
Authors:
S. J. C. Yates,
K. K. Davis,
W. Jellema,
J. J. A. Baselmans,
A. M. Baryshev
Abstract:
For astronomical instruments, accurate knowledge of the optical pointing and coupling are essential to characterize the alignment and performance of (sub-)systems prior to integration and deployment. Ideally, this requires the phase response of the optical system, which for direct (phase insensitive) detectors was not previously accessible. Here we show development of the phase sensitive complex b…
▽ More
For astronomical instruments, accurate knowledge of the optical pointing and coupling are essential to characterize the alignment and performance of (sub-)systems prior to integration and deployment. Ideally, this requires the phase response of the optical system, which for direct (phase insensitive) detectors was not previously accessible. Here we show development of the phase sensitive complex beam pattern technique using a dual optical source heterodyne technique for a large field of view Microwave Kinetic Inductance Detector camera at 350 GHz. We show here how you can analyze the measured data with Fourier optics, which allows integration into a telescope model to calculate the on sky beam pattern and telescope aperture efficiency prior to deployment at a telescope.
△ Less
Submitted 10 February, 2020;
originally announced February 2020.
-
DESHIMA on ASTE: On-sky Responsivity Calibration of the Integrated Superconducting Spectrometer
Authors:
Tatsuya Takekoshi,
Kenichi Karatsu,
Junya Suzuki,
Yoichi Tamura,
Tai Oshima,
Akio Taniguchi,
Shin'ichiro Asayama,
Tom J. L. C. Bakx,
Jochem J. A. Baselmans,
Sjoerd Bosma,
Juan Bueno,
Kah Wuy Chin,
Yasunori Fujii,
Kazuyuki Fujita,
Robert Huiting,
Soh Ikarashi,
Tsuyoshi Ishida,
Shun Ishii,
Ryohei Kawabe,
Teun M. Klapwijk,
Kotaro Kohno,
Akira Kouchi,
Nuria Llombart,
Jun Maekawa,
Vignesh Murugesan
, et al. (14 additional authors not shown)
Abstract:
We are developing an ultra-wideband spectroscopic instrument, DESHIMA (DEep Spectroscopic HIgh-redshift MApper), based on the technologies of an on-chip filter-bank and Microwave Kinetic Inductance Detector (MKID) to investigate dusty star-burst galaxies in the distant universe at millimeter and submillimeter wavelength. An on-site experiment of DESHIMA was performed using the ASTE 10-m telescope.…
▽ More
We are developing an ultra-wideband spectroscopic instrument, DESHIMA (DEep Spectroscopic HIgh-redshift MApper), based on the technologies of an on-chip filter-bank and Microwave Kinetic Inductance Detector (MKID) to investigate dusty star-burst galaxies in the distant universe at millimeter and submillimeter wavelength. An on-site experiment of DESHIMA was performed using the ASTE 10-m telescope. We established a responsivity model that converts frequency responses of the MKIDs to line-of-sight brightness temperature. We estimated two parameters of the responsivity model using a set of skydip data taken under various precipitable water vapor (PWV, 0.4-3.0 mm) conditions for each MKID. The line-of-sight brightness temperature of sky is estimated using an atmospheric transmission model and the PWVs. As a result, we obtain an average temperature calibration uncertainty of $1σ=4$%, which is smaller than other photometric biases. In addition, the average forward efficiency of 0.88 in our responsivity model is consistent with the value expected from the geometrical support structure of the telescope. We also estimate line-of-sight PWVs of each skydip observation using the frequency response of MKIDs, and confirm the consistency with PWVs reported by the Atacama Large Millimeter/submillimeter Array.
△ Less
Submitted 15 January, 2020;
originally announced January 2020.
-
Ozone chemistry on tidally locked M dwarf planets
Authors:
Jack S. Yates,
Paul I. Palmer,
James Manners,
Ian Boutle,
Krisztian Kohary,
Nathan Mayne,
Luke Abraham
Abstract:
We use the Met Office Unified Model to explore the potential of a tidally locked M dwarf planet, nominally Proxima Centauri b irradiated by a quiescent version of its host star, to sustain an atmospheric ozone layer. We assume a slab ocean surface layer, and an Earth-like atmosphere of nitrogen and oxygen with trace amounts of ozone and water vapour. We describe ozone chemistry using the Chapman m…
▽ More
We use the Met Office Unified Model to explore the potential of a tidally locked M dwarf planet, nominally Proxima Centauri b irradiated by a quiescent version of its host star, to sustain an atmospheric ozone layer. We assume a slab ocean surface layer, and an Earth-like atmosphere of nitrogen and oxygen with trace amounts of ozone and water vapour. We describe ozone chemistry using the Chapman mechanism and the hydrogen oxide (HO$_x$, describing the sum of OH and HO$_2$) catalytic cycle. We find that Proxima Centauri radiates with sufficient UV energy to initialize the Chapman mechanism. The result is a thin but stable ozone layer that peaks at 0.75 parts per million at 25 km. The quasi-stationary distribution of atmospheric ozone is determined by photolysis driven by incoming stellar radiation and by atmospheric transport. Ozone mole fractions are smallest in the lowest 15 km of the atmosphere at the sub-stellar point and largest in the nightside gyres. Above 15 km the ozone distribution is dominated by an equatorial jet stream that circumnavigates the planet. The nightside ozone distribution is dominated by two cyclonic Rossby gyres that result in localized ozone hotspots. On the dayside the atmospheric lifetime is determined by the HO$_x$ catalytic cycle and deposition to the surface, with nightside lifetimes due to chemistry much longer than timescales associated with atmospheric transport. Surface UV values peak at the substellar point with values of 0.01 W/m$^2$, shielded by the overlying atmospheric ozone layer but more importantly by water vapour clouds.
△ Less
Submitted 18 December, 2019;
originally announced December 2019.
-
First light demonstration of the integrated superconducting spectrometer
Authors:
Akira Endo,
Kenichi Karatsu,
Yoichi Tamura,
Tai Oshima,
Akio Taniguchi,
Tatsuya Takekoshi,
Shin'ichiro Asayama,
Tom J. L. C. Bakx,
Sjoerd Bosma,
Juan Bueno,
Kah Wuy Chin,
Yasunori Fujii,
Kazuyuki Fujita,
Robert Huiting,
Soh Ikarashi,
Tsuyoshi Ishida,
Shun Ishii,
Ryohei Kawabe,
Teun M. Klapwijk,
Kotaro Kohno,
Akira Kouchi,
Nuria Llombart,
Jun Maekawa,
Vignesh Murugesan,
Shunichi Nakatsubo
, et al. (14 additional authors not shown)
Abstract:
Ultra-wideband 3D imaging spectrometry in the millimeter-submillimeter (mm-submm) band is an essential tool for uncovering the dust-enshrouded portion of the cosmic history of star formation and galaxy evolution. However, it is challenging to scale up conventional coherent heterodyne receivers or free-space diffraction techniques to sufficient bandwidths ($\geq$1 octave) and numbers of spatial pix…
▽ More
Ultra-wideband 3D imaging spectrometry in the millimeter-submillimeter (mm-submm) band is an essential tool for uncovering the dust-enshrouded portion of the cosmic history of star formation and galaxy evolution. However, it is challenging to scale up conventional coherent heterodyne receivers or free-space diffraction techniques to sufficient bandwidths ($\geq$1 octave) and numbers of spatial pixels (>$10^2$). Here we present the design and first astronomical spectra of an intrinsically scalable, integrated superconducting spectrometer, which covers 332-377 GHz with a spectral resolution of $F/ΔF \sim 380$. It combines the multiplexing advantage of microwave kinetic inductance detectors (MKIDs) with planar superconducting filters for dispersing the signal in a single, small superconducting integrated circuit. We demonstrate the two key applications for an instrument of this type: as an efficient redshift machine, and as a fast multi-line spectral mapper of extended areas. The line detection sensitivity is in excellent agreement with the instrument design and laboratory performance, reaching the atmospheric foreground photon noise limit on sky. The design can be scaled to bandwidths in excess of an octave, spectral resolution up to a few thousand and frequencies up to $\sim$1.1 THz. The miniature chip footprint of a few $\mathrm{cm^2}$ allows for compact multi-pixel spectral imagers, which would enable spectroscopic direct imaging and large volume spectroscopic surveys that are several orders of magnitude faster than what is currently possible.
△ Less
Submitted 18 September, 2019; v1 submitted 24 June, 2019;
originally announced June 2019.
-
Wideband on-chip terahertz spectrometer based on a superconducting filterbank
Authors:
Akira Endo,
Kenichi Karatsu,
Alejandro Pascual Laguna,
Behnam Mirzaei,
Robert Huiting,
David J. Thoen,
Vignesh Murugesan,
Stephen J. C. Yates,
Juan Bueno,
Nuri van Marrewijk,
Sjoerd Bosma,
Ozan Yurduseven,
Nuria Llombart,
Junya Suzuki,
Masato Naruse,
Pieter J. de Visser,
Paul P. van der Werf,
Teun M. Klapwijk,
Jochem J. A. Baselmans
Abstract:
Terahertz spectrometers with a wide instantaneous frequency coverage for passive remote sensing are enormously attractive for many terahertz applications, such as astronomy, atmospheric science and security. Here we demonstrate a wide-band terahertz spectrometer based on a single superconducting chip. The chip consists of an antenna coupled to a transmission line filterbank, with a microwave kinet…
▽ More
Terahertz spectrometers with a wide instantaneous frequency coverage for passive remote sensing are enormously attractive for many terahertz applications, such as astronomy, atmospheric science and security. Here we demonstrate a wide-band terahertz spectrometer based on a single superconducting chip. The chip consists of an antenna coupled to a transmission line filterbank, with a microwave kinetic inductance detector behind each filter. Using frequency division multiplexing, all detectors are read-out simultaneously creating a wide-band spectrometer with an instantaneous bandwidth of 45 GHz centered around 350 GHz. The spectrometer has a spectral resolution of $F/ΔF=380$ and reaches photon-noise limited sensitivity. We discuss the chip design and fabrication, as well as the system integration and testing. We confirm full system operation by the detection of an emission line spectrum of methanol gas. The proposed concept allows for spectroscopic radiation detection over large bandwidths and resolutions up to $F/ΔF\sim1000$, all using a chip area of a few $\mathrm{cm^2}$. This will allow the construction of medium resolution imaging spectrometers with unprecedented speed and sensitivity.
△ Less
Submitted 21 June, 2019; v1 submitted 21 January, 2019;
originally announced January 2019.
-
Analysis techniques for complex-field radiation pattern measurements
Authors:
Kristina K. Davis,
Willem Jellema,
Stephen J. C. Yates,
Christopher E. Groppi,
Jochem J. A. Baselmans,
Andrey M. Baryshev
Abstract:
Complex field measurements are increasingly becoming the standard for state-of-the-art astronomical instrumentation. Complex field measurements have been used to characterize a suite of ground, airborne, and space-based heterodyne receiver missions [1], [2], [3], [4], [5], [6], and a description of how to acquire coherent field maps for direct detector arrays was demonstrated in Davis et. al. 2017…
▽ More
Complex field measurements are increasingly becoming the standard for state-of-the-art astronomical instrumentation. Complex field measurements have been used to characterize a suite of ground, airborne, and space-based heterodyne receiver missions [1], [2], [3], [4], [5], [6], and a description of how to acquire coherent field maps for direct detector arrays was demonstrated in Davis et. al. 2017. This technique has the ability to determine both amplitude and phase radiation patterns from individual pixels on an array. Phase information helps to better characterize the optical performance of the array (as compared to total power radiation patterns) by constraining the fit in an additional plane [4].
Here we discuss the mathematical framework used in an analysis pipeline developed to process complex field radiation pattern measurements. This routine determines and compensates misalignments of the instrument and scanning system. We begin with an overview of Gaussian beam formalism and how it relates to complex field pattern measurements. Next we discuss a scan strategy using an offset in z along the optical axis that allows first-order optical standing waves between the scanned source and optical system to be removed in post-processing. Also discussed is a method by which the co- and cross-polarization fields can be extracted individually for each pixel by rotating the two orthogonal measurement planes until the signal is the co-polarization map is maximized (and the signal in the cross-polarization field is minimized). We detail a minimization function that can fit measurement data to an arbitrary beam shape model. We conclude by discussing the angular plane wave spectral (APWS) method for beam propagation, including the near-field to far-field transformation.
△ Less
Submitted 21 September, 2018;
originally announced September 2018.
-
Eliminating stray radiation inside large area imaging arrays
Authors:
Stephen J. C. Yates,
Simon Doyle,
Peter Barry,
Andrey M. Baryshev,
Juan Bueno,
Lorenza Ferrari,
Nuria Llombart,
Vignesh Murugesan,
David J. Thoen,
Ozan Yurduseven,
Jochem J. A. Baselmans
Abstract:
With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves. We demonstrate this effect with focal plane arrays of absorber coupled Lumped Element microwave Kinetic Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the response from a poin…
▽ More
With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves. We demonstrate this effect with focal plane arrays of absorber coupled Lumped Element microwave Kinetic Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the response from a point source at the pixel position is at a similar level to the stray response integrated over the entire chip area. For the antenna coupled arrays, we show that this effect can be suppressed by incorporating an on-chip stray light absorber. A similar method should be possible with the LEKID array, especially when they are lens coupled.
△ Less
Submitted 11 September, 2018;
originally announced September 2018.
-
Surface wave control for large arrays of microwave kinetic inductance detectors
Authors:
Stephen J. C. Yates,
Andrey M. Baryshev,
Ozan Yurduseven,
Juan Bueno,
Kristina K. Davis,
Lorenza Ferrari,
Willem Jellema,
Nuria Llombart,
Vignesh Murugesan,
David J. Thoen,
Jochem J. A. Baselmans
Abstract:
Large ultra-sensitive detector arrays are needed for present and future observatories for far infra-red, submillimeter wave (THz), and millimeter wave astronomy. With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves, the surface wave. We demonstrate this effect with focal plane arrays of 880 lens-antenna coupled Microwave Kinetic I…
▽ More
Large ultra-sensitive detector arrays are needed for present and future observatories for far infra-red, submillimeter wave (THz), and millimeter wave astronomy. With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves, the surface wave. We demonstrate this effect with focal plane arrays of 880 lens-antenna coupled Microwave Kinetic Inductance Detectors (MKIDs). Presented here are near field measurements of the MKID optical response versus the position on the array of a reimaged optical source. We demonstrate that the optical response of a detector in these arrays saturates off-pixel at the $\sim-30$ dB level compared to the peak pixel response. The result is that the power detected from a point source at the pixel position is almost identical to the stray response integrated over the chip area. With such a contribution, it would be impossible to measure extended sources, while the point source sensitivity is degraded due to an increase of the stray loading. However, we show that by incorporating an on-chip stray light absorber, the surface wave contribution is reduced by a factor $>$10. With the on-chip stray light absorber the point source response is close to simulations down to the $\sim-35$ dB level, the simulation based on an ideal Gaussian illumination of the optics. In addition, as a crosscheck we show that the extended source response of a single pixel in the array with the absorbing grid is in agreement with the integral of the point source measurements.
△ Less
Submitted 7 July, 2017;
originally announced July 2017.
-
Atmospheric Habitable Zones in Cool Y Dwarf Atmospheres
Authors:
Jack S. Yates,
Paul I. Palmer,
Beth Biller,
Charles S. Cockell
Abstract:
We use a simple organism lifecycle model to explore the viability of an atmospheric habitable zone (AHZ), with temperatures that could support Earth-centric life, which sits above an environment that does not support life. To illustrate our model we use a cool Y dwarf atmosphere, such as $\mathrm{WISE~J}085510.83-0714442.5$ whose $4.5-5.2$ micron spectrum shows absorption features consistent with…
▽ More
We use a simple organism lifecycle model to explore the viability of an atmospheric habitable zone (AHZ), with temperatures that could support Earth-centric life, which sits above an environment that does not support life. To illustrate our model we use a cool Y dwarf atmosphere, such as $\mathrm{WISE~J}085510.83-0714442.5$ whose $4.5-5.2$ micron spectrum shows absorption features consistent with water vapour and clouds. We allow organisms to adapt to their atmospheric environment (described by temperature, convection, and gravity) by adopting different growth strategies that maximize their chance of survival and proliferation. We assume a constant upward vertical velocity through the AHZ. We found that the organism growth strategy is most sensitive to the magnitude of the atmospheric convection. Stronger convection supports the evolution of more massive organisms. For a purely radiative environment we find that evolved organisms have a mass that is an order of magnitude smaller than terrestrial microbes, thereby defining a dynamical constraint on the dimensions of life that an AHZ can support. Based on a previously defined statistical approach we infer that there are of order $10^9$ cool Y brown dwarfs in the Milky Way, and likely a few tens of these objects are within ten parsecs from Earth. Our work also has implications for exploring life in the atmospheres of temperate gas giants. Consideration of the habitable volumes in planetary atmospheres significantly increases the volume of habitable space in the galaxy.
△ Less
Submitted 20 December, 2016; v1 submitted 28 November, 2016;
originally announced November 2016.
-
A kilo-pixel imaging system for future space based far-infrared observatories using microwave kinetic inductance detectors
Authors:
J. J. A. Baselmans,
J. Bueno,
S. J. C. Yates,
O. Yurduseven,
N. Llombart,
K. Karatsu,
A. M. Baryshev,
L. Ferrari,
A. Endo,
D. J. Thoen,
P. J. de Visser,
R. M. J. Janssen,
V. Murugesan,
E. F. C. Driessen,
G. Coiffard,
J. Martin-Pintado,
P. Hargrave,
M. Griffin
Abstract:
Future astrophysics and cosmic microwave background space missions operating in the far-infrared to millimetre part of the spectrum will require very large arrays of ultra-sensitive detectors in combination with high multiplexing factors and efficient low-noise and low-power readout systems. We have developed a demonstrator system suitable for such applications. The system combines a 961 pixel ima…
▽ More
Future astrophysics and cosmic microwave background space missions operating in the far-infrared to millimetre part of the spectrum will require very large arrays of ultra-sensitive detectors in combination with high multiplexing factors and efficient low-noise and low-power readout systems. We have developed a demonstrator system suitable for such applications. The system combines a 961 pixel imaging array based upon Microwave Kinetic Inductance Detectors (MKIDs) with a readout system capable of reading out all pixels simultaneously with only one readout cable pair and a single cryogenic amplifier. We evaluate, in a representative environment, the system performance in terms of sensitivity, dynamic range, optical efficiency, cosmic ray rejection, pixel-pixel crosstalk and overall yield at at an observation centre frequency of 850 GHz and 20% fractional bandwidth. The overall system has an excellent sensitivity, with an average detector sensitivity NEPdet=3x10^-19 W/rt(Hz) measured using a thermal calibration source. At a loading power per pixel of 50fW we demonstrate white, photon noise limited detector noise down to 300 mHz. The dynamic range would allow the detection of 1 Jy bright sources within the field of view without tuning the readout of the detectors. The expected dead time due to cosmic ray interactions, when operated in an L2 or a similar far-Earth orbit, is found to be <4%. Additionally, the achieved pixel yield is 83% and the crosstalk between the pixels is <-30dB. This demonstrates that MKID technology can provide multiplexing ratios on the order of a 1000 with state-of-the-art single pixel performance, and that the technology is now mature enough to be considered for future space based observatories and experiments.
△ Less
Submitted 1 March, 2017; v1 submitted 7 September, 2016;
originally announced September 2016.
-
Measurements and analysis of optical crosstalk in a microwave kinetic inductance detector array
Authors:
L. Bisigello,
S. J. C. Yates,
L. Ferrari,
J. J. A. Baselmans,
A. M. Baryshev
Abstract:
The main advantage of Microwave Kinetic Inductance Detector arrays (MKID) is their multiplexing capability, which allows for building cameras with a large number of pixels and good sensitivity, particularly suitable to perform large blank galaxy surveys. However, to have as many pixels as possible it is necessary to arrange detectors close in readout frequency. Consequently KIDs overlap in frequen…
▽ More
The main advantage of Microwave Kinetic Inductance Detector arrays (MKID) is their multiplexing capability, which allows for building cameras with a large number of pixels and good sensitivity, particularly suitable to perform large blank galaxy surveys. However, to have as many pixels as possible it is necessary to arrange detectors close in readout frequency. Consequently KIDs overlap in frequency and are coupled to each other producing crosstalk. Because crosstalk can be only minimised by improving the array design, in this work we aim to correct for this effect a posteriori. We analysed a MKID array consisting of 880 KIDs with readout frequencies at 4-8 GHz. We measured the beam patterns for every detector in the array and described the response of each detector by using a two-dimensional Gaussian fit. Then, we identified detectors affected by crosstalk above -30 dB level from the maximum and removed the signal of the crosstalking detectors. Moreover, we modelled the crosstalk level for each KID as a function of the readout frequency separation starting from the assumption that the transmission of a KID is a Lorenztian function in power. We were able to describe the general crosstalk level of the array and the crosstalk of each KID within 5 dB, so enabling the design of future arrays with the crosstalk as a design criterion. In this work, we demonstrate that it is possible to process MKID images a posteriori to decrease the crosstalk effect, subtracting the response of each coupled KID from the original map.
△ Less
Submitted 1 September, 2016;
originally announced September 2016.
-
Calibration scheme for large Kinetic Inductance Detector Arrays based on Readout Frequency Response
Authors:
L. Bisigello,
S. J. C. Yates,
V. Murugesan,
J. J. A. Baselmans,
A. M. Baryshev
Abstract:
Microwave kinetic inductance detector (MKID) provides a way to build large ground based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good linearity and calibration over wide dynamic range. We propose to use the MKID readout frequency response to determine the MKID responsivity to an input optical…
▽ More
Microwave kinetic inductance detector (MKID) provides a way to build large ground based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good linearity and calibration over wide dynamic range. We propose to use the MKID readout frequency response to determine the MKID responsivity to an input optical source power. A signal can be measured in a KID as a change in the phase of the readout signal with respect to the KID resonant circle. Fundamentally, this phase change is due to a shift in the KID resonance frequency, in turn due to a radiation induced change in the quasiparticle number in the superconducting resonator. We show that shift in resonant frequency can be determined from the phase shift by using KID phase versus frequency dependence using a previously measured resonant frequency. Working in this calculated resonant frequency, we gain near linearity and constant calibration to a constant optical signal applied in a wide range of operating points on the resonance and readout powers. This calibration method has three particular advantages: first, it is fast enough to be used to calibrate large arrays, with pixel counts in the thousand of pixels; second, it is based on data that are already necessary to determine KID positions; third, it can be done without applying any optical source in front of the array.
△ Less
Submitted 1 February, 2016;
originally announced February 2016.
-
Multiplexed Readout for 1000-pixel Arrays of Microwave Kinetic Inductance Detectors
Authors:
Joris van Rantwijk,
Martin Grim,
Dennis van Loon,
Stephen Yates,
Andrey Baryshev,
Jochem Baselmans
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) are the most attractive radiation detectors for far-infrared and sub-mm astronomy: They combine ultimate sensitivity with the possibility to create very large detector arrays, in excess of 10 000 pixels. This is possible by reading-out the arrays using RF frequency division multiplexing, which allows multiplexing ratios in excess of 1000 pixels per re…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) are the most attractive radiation detectors for far-infrared and sub-mm astronomy: They combine ultimate sensitivity with the possibility to create very large detector arrays, in excess of 10 000 pixels. This is possible by reading-out the arrays using RF frequency division multiplexing, which allows multiplexing ratios in excess of 1000 pixels per readout line. We describe a novel readout system for large arrays of MKIDs, operating in a 2 GHz band in the 4-8 GHz range. The readout, which is a combination of a digital front- and back-end and an analog up- and down-converter system, can read out up to 4000 detectors simultaneously with 1 kHz datarate. The system achieves a readout noise power spectral density of -98 dBc/Hz while reading 1000 carriers simultaneously, which scales linear with the number of carriers. We demonstrate that 4000 state-of-the-art Aluminium-NbTiN MKIDs can be read out without deteriorating their intrinsic performance.
△ Less
Submitted 1 April, 2016; v1 submitted 15 July, 2015;
originally announced July 2015.
-
The non-equilibrium response of a superconductor to pair-breaking radiation measured over a broad frequency band
Authors:
P. J. de Visser,
S. J. C. Yates,
T. Guruswamy,
D. J. Goldie,
S. Withington,
A. Neto,
N. Llombart,
A. M. Baryshev,
T. M. Klapwijk,
J. J. A. Baselmans
Abstract:
We have measured the absorption of terahertz radiation in a BCS superconductor over a broad range of frequencies from 200 GHz to 1.1 THz, using a broadband antenna-lens system and a tantalum microwave resonator. From low frequencies, the response of the resonator rises rapidly to a maximum at the gap edge of the superconductor. From there on the response drops to half the maximum response at twice…
▽ More
We have measured the absorption of terahertz radiation in a BCS superconductor over a broad range of frequencies from 200 GHz to 1.1 THz, using a broadband antenna-lens system and a tantalum microwave resonator. From low frequencies, the response of the resonator rises rapidly to a maximum at the gap edge of the superconductor. From there on the response drops to half the maximum response at twice the pair-breaking energy. At higher frequencies, the response rises again due to trapping of pair-breaking phonons in the superconductor. In practice this is the first measurement of the frequency dependence of the quasiparticle creation efficiency due to pair-breaking in a superconductor. The efficiency, calculated from the different non-equilibrium quasiparticle distribution functions at each frequency, is in agreement with the measurements.
△ Less
Submitted 22 May, 2015;
originally announced May 2015.
-
Performance of Hybrid NbTiN-Al Microwave Kinetic Inductance Detectors as Direct Detectors for Sub-millimeter Astronomy
Authors:
R. M. J. Janssen,
J. J. A. Baselmans,
A. Endo,
L. Ferrari,
S. J. C. Yates,
A. M. Baryshev,
T. M. Klapwijk
Abstract:
In the next decades millimeter and sub-mm astronomy requires large format imaging arrays and broad-band spectrometers to complement the high spatial and spectral resolution of the Atacama Large Millimeter/sub-millimeter Array. The desired sensors for these instruments should have a background limited sensitivity and a high optical efficiency and enable arrays thousands of pixels in size. Hybrid mi…
▽ More
In the next decades millimeter and sub-mm astronomy requires large format imaging arrays and broad-band spectrometers to complement the high spatial and spectral resolution of the Atacama Large Millimeter/sub-millimeter Array. The desired sensors for these instruments should have a background limited sensitivity and a high optical efficiency and enable arrays thousands of pixels in size. Hybrid microwave kinetic inductance detectors consisting of NbTiN and Al have shown to satisfy these requirements. We present the second generation hybrid NbTiN-Al MKIDs, which are photon noise limited in both phase and amplitude readout for loading levels $P_{850GHz} \geq 10$ fW. Thanks to the increased responsivity, the photon noise level achieved in phase allows us to simultaneously read out approximately 8000 pixels using state-of-the-art electronics. In addition, the choice of superconducting materials and the use of a Si lens in combination with a planar antenna gives these resonators the flexibility to operate within the frequency range $0.09 < ν< 1.1$ THz. Given these specifications, hybrid NbTiN-Al MKIDs will enable astronomically usable kilopixel arrays for sub-mm imaging and moderate resolution spectroscopy.
△ Less
Submitted 14 August, 2014;
originally announced August 2014.
-
High optical efficiency and photon noise limited sensitivity of microwave kinetic inductance detectors using phase readout
Authors:
R. M. J. Janssen,
J. J. A. Baselmans,
A. Endo,
L. Ferrari,
S. J. C. Yates,
A. M. Baryshev,
T. M. Klapwijk
Abstract:
We demonstrate photon noise limited performance in both phase and amplitude readout in microwave kinetic inductance detectors (MKIDs) consisting of NbTiN and Al, down to 100 fW of optical power. We simulate the far field beam pattern of the lens-antenna system used to couple radiation into the MKID and derive an aperture efficiency of 75%. This is close to the theoretical maximum of 80% for a sing…
▽ More
We demonstrate photon noise limited performance in both phase and amplitude readout in microwave kinetic inductance detectors (MKIDs) consisting of NbTiN and Al, down to 100 fW of optical power. We simulate the far field beam pattern of the lens-antenna system used to couple radiation into the MKID and derive an aperture efficiency of 75%. This is close to the theoretical maximum of 80% for a single-moded detector. The beam patterns are verified by a detailed analysis of the optical coupling within our measurement setup.
△ Less
Submitted 11 November, 2013;
originally announced November 2013.
-
Design and Testing of Kinetic Inductance Detectors Made of Titanium Nitride
Authors:
P. Diener,
H. G. Leduc,
S. J. C. Yates,
Y. J. Y. Lankwarden,
J. J. A. Baselmans
Abstract:
To use highly resistive material for Kinetic Inductance Detectors (KID), new designs have to be done, in part due to the impedance match needed between the KID chip and the whole 50 ohms readout circuit. Chips from two new hybrid designs, with an aluminum throughline coupled to titanium nitride microresonators, have been measured and compared to a TiN only chip. In the hybrid chips, parasitic temp…
▽ More
To use highly resistive material for Kinetic Inductance Detectors (KID), new designs have to be done, in part due to the impedance match needed between the KID chip and the whole 50 ohms readout circuit. Chips from two new hybrid designs, with an aluminum throughline coupled to titanium nitride microresonators, have been measured and compared to a TiN only chip. In the hybrid chips, parasitic temperature dependent box resonances are absent. The dark KID properties have been measured in a large set of resonators. A surprisingly long lifetime, up to 5.6 ms is observed in a few KIDs. For the other more reproducible devices, the mean electrical Noise Equivalent Power is 5.4 10-19 W.Hz1/2.
△ Less
Submitted 17 September, 2013;
originally announced September 2013.
-
On-chip filter bank spectroscopy at 600-700 GHz using NbTiN superconducting resonators
Authors:
A. Endo,
C. Sfiligoj,
S. J. C. Yates,
J. J. A. Baselmans,
D. J. Thoen,
S. M. H. Javadzadeh,
P. P. van der Werf,
A. M. Baryshev,
T. M. Klapwijk
Abstract:
We experimentally demonstrate the principle of an on-chip submillimeter wave filter bank spectrometer, using superconducting microresonators as narrow band-separation filters. The filters are made of NbTiN/SiNx/NbTiN microstrip line resonators, which have a resonance frequency in the range of 614-685 GHz---two orders of magnitude higher in frequency than what is currently studied for use in circui…
▽ More
We experimentally demonstrate the principle of an on-chip submillimeter wave filter bank spectrometer, using superconducting microresonators as narrow band-separation filters. The filters are made of NbTiN/SiNx/NbTiN microstrip line resonators, which have a resonance frequency in the range of 614-685 GHz---two orders of magnitude higher in frequency than what is currently studied for use in circuit quantum electrodynamics and photodetectors. The frequency resolution of the filters decreases from 350 to 140 with increasing frequency, most likely limited by dissipation of the resonators.
△ Less
Submitted 21 June, 2013; v1 submitted 28 March, 2013;
originally announced March 2013.
-
Photon noise limited radiation detection with lens-antenna coupled Microwave Kinetic Inductance Detectors
Authors:
S. J. C. Yates,
J. J. A. Baselmans,
A. Endo,
R. M. J. Janssen,
L. Ferrari,
P. Diener,
A. M. Baryshev
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) have shown great potential for sub-mm instrumentation because of the high scalability of the technology. Here we demonstrate for the first time in the sub-mm band (0.1...2 mm) a photon noise limited performance of a small antenna coupled MKID detector array and we describe the relation between photon noise and MKID intrinsic generation-recombination n…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) have shown great potential for sub-mm instrumentation because of the high scalability of the technology. Here we demonstrate for the first time in the sub-mm band (0.1...2 mm) a photon noise limited performance of a small antenna coupled MKID detector array and we describe the relation between photon noise and MKID intrinsic generation-recombination noise. Additionally we use the observed photon noise to measure the optical efficiency of detectors to be 0.8+-0.2.
△ Less
Submitted 21 July, 2011;
originally announced July 2011.
-
Integrated Filterbank for DESHIMA: A Submillimeter Imaging Spectrograph Based on Superconducting Resonators
Authors:
A. Endo,
P. van der Werf,
R. M. J. Janssen,
P. J. de Visser,
T. M. Klapwijk,
J. J. A. Baselmans,
L. Ferrari,
A. M. Baryshev,
S. J. C. Yates
Abstract:
An integrated filterbank (IFB) in combination with microwave kinetic inductance detectors (MKIDs), both based on superconducting resonators, could be used to make broadband submillimeter imaging spectrographs that are compact and flexible. In order to investigate the possibility of adopting an IFB configuration for DESHIMA (Delft SRON High-redshift Mapper), we study the basic properties of a copla…
▽ More
An integrated filterbank (IFB) in combination with microwave kinetic inductance detectors (MKIDs), both based on superconducting resonators, could be used to make broadband submillimeter imaging spectrographs that are compact and flexible. In order to investigate the possibility of adopting an IFB configuration for DESHIMA (Delft SRON High-redshift Mapper), we study the basic properties of a coplanar-waveguide-based IFB using electromagnetic simulation. We show that a coupling efficiency greater than 1/2 can be achieved if transmission losses are negligible. We arrive at a practical design for a 9 pixel x 920 color 3 dimensional imaging device that fits on a 4 inch wafer, which instantaneously covers multiple submillimeter telluric windows with a dispersion of f/df = 1000.
△ Less
Submitted 17 July, 2011;
originally announced July 2011.
-
Number fluctuations of sparse quasiparticles in a superconductor
Authors:
P. J. de Visser,
J. J. A. Baselmans,
P. Diener,
S. J. C. Yates,
A. Endo,
T. M. Klapwijk
Abstract:
We have directly measured quasiparticle number fluctuations in a thin film superconducting Al resonator in thermal equilibrium. The spectrum of these fluctuations provides a measure of both the density and the lifetime of the quasiparticles. We observe that the quasiparticle density decreases exponentially with decreasing temperature, as theoretically predicted, but saturates below 160 mK to 25-55…
▽ More
We have directly measured quasiparticle number fluctuations in a thin film superconducting Al resonator in thermal equilibrium. The spectrum of these fluctuations provides a measure of both the density and the lifetime of the quasiparticles. We observe that the quasiparticle density decreases exponentially with decreasing temperature, as theoretically predicted, but saturates below 160 mK to 25-55 per cubic micron. We show that this saturation is consistent with the measured saturation in the quasiparticle lifetime, which also explains similar observations in qubit decoherence times.
△ Less
Submitted 25 March, 2011; v1 submitted 3 March, 2011;
originally announced March 2011.
-
A dual-band millimeter-wave kinetic inductance camera for the IRAM 30-meter telescope
Authors:
A. Monfardini,
A. Benoit,
A. Bideaud,
L. J. Swenson,
M. Roesch,
F. X. Desert,
S. Doyle,
A. Endo,
A. Cruciani,
P. Ade,
A. M. Baryshev,
J. J. A. Baselmans,
O. Bourrion,
M. Calvo,
P. Camus,
L. Ferrari,
C. Giordano,
C. Hoffmann,
S. Leclercq,
J. F. Macias-Perez,
P. Mauskopf,
K. F. Schuster,
C. Tucker,
C. Vescovi,
S. J. C. Yates
Abstract:
Context. The Neel IRAM KIDs Array (NIKA) is a fully-integrated measurement system based on kinetic inductance detectors (KIDs) currently being developed for millimeter wave astronomy. In a first technical run, NIKA was successfully tested in 2009 at the Institute for Millimetric Radio Astronomy (IRAM) 30-meter telescope at Pico Veleta, Spain. This prototype consisted of a 27-42 pixel camera imagin…
▽ More
Context. The Neel IRAM KIDs Array (NIKA) is a fully-integrated measurement system based on kinetic inductance detectors (KIDs) currently being developed for millimeter wave astronomy. In a first technical run, NIKA was successfully tested in 2009 at the Institute for Millimetric Radio Astronomy (IRAM) 30-meter telescope at Pico Veleta, Spain. This prototype consisted of a 27-42 pixel camera imaging at 150 GHz. Subsequently, an improved system has been developed and tested in October 2010 at the Pico Veleta telescope. The instrument upgrades included dual-band optics allowing simultaneous imaging at 150 GHz and 220 GHz, faster sampling electronics enabling synchronous measurement of up to 112 pixels per measurement band, improved single-pixel sensitivity, and the fabrication of a sky simulator to replicate conditions present at the telescope. Results. The new dual-band NIKA was successfully tested in October 2010, performing in-line with sky simulator predictions. Initially the sources targeted during the 2009 run were re-imaged, verifying the improved system performance. An optical NEP was then calculated to be around 2 \dot 10-16 W/Hz1/2. This improvement in comparison with the 2009 run verifies that NIKA is approaching the target sensitivity for photon-noise limited ground-based detectors. Taking advantage of the larger arrays and increased sensitivity, a number of scientifically-relevant faint and extended objects were then imaged including the Galactic Center SgrB2(FIR1), the radio galaxy Cygnus A and the NGC1068 Seyfert galaxy. These targets were all observed simultaneously in the 150 GHz and 220 GHz atmospheric windows.
△ Less
Submitted 8 February, 2011; v1 submitted 4 February, 2011;
originally announced February 2011.
-
NIKA: A millimeter-wave kinetic inductance camera
Authors:
A. Monfardini,
L. J. Swenson,
A. Bideaud,
F. X. Désert,
S. J. C. Yates,
A. Benoit,
A. M. Baryshev,
J. J. A. Baselmans,
S. Doyle,
B. Klein,
M. Roesch,
C. Tucker,
P. Ade,
M. Calvo,
P. Camus,
C. Giordano,
R. Guesten,
C. Hoffmann,
S. Leclercq,
P. Mauskopf,
K. F. Schuster
Abstract:
Current generation millimeter wavelength detectors suffer from scaling limits imposed by complex cryogenic readout electronics. To circumvent this it is imperative to investigate technologies that intrinsically incorporate strong multiplexing. One possible solution is the kinetic inductance detector (KID). In order to assess the potential of this nascent technology, a prototype instrument optimize…
▽ More
Current generation millimeter wavelength detectors suffer from scaling limits imposed by complex cryogenic readout electronics. To circumvent this it is imperative to investigate technologies that intrinsically incorporate strong multiplexing. One possible solution is the kinetic inductance detector (KID). In order to assess the potential of this nascent technology, a prototype instrument optimized for the 2 mm atmospheric window was constructed. Known as the Néel IRAM KIDs Array (NIKA), it was recently tested at the Institute for Millimetric Radio Astronomy (IRAM) 30-meter telescope at Pico Veleta, Spain. The measurement resulted in the imaging of a number of sources, including planets, quasars, and galaxies. The images for Mars, radio star MWC349, quasar 3C345, and galaxy M87 are presented. From these results, the optical NEP was calculated to be around $1 \times 10^{-15}$ W$ / $Hz$^{1/2}$. A factor of 10 improvement is expected to be readily feasible by improvements in the detector materials and reduction of performance-degrading spurious radiation.
△ Less
Submitted 20 June, 2010; v1 submitted 13 April, 2010;
originally announced April 2010.
-
FFTS readout for large arrays of Microwave Kinetic Inductance Detectors
Authors:
S. J. C. Yates,
A. M. Baryshev,
J. J. A. Baselmans,
B. Klein,
R. Güsten
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) have great potential for large very sensitive detector arrays for use in, for example, sub-mm imaging. Being intrinsically readout in the frequency domain, they are particularly suited for frequency domain multiplexing allowing $\sim$1000s of devices to be readout with one pair of coaxial cables. However, this moves the complexity of the detector fr…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) have great potential for large very sensitive detector arrays for use in, for example, sub-mm imaging. Being intrinsically readout in the frequency domain, they are particularly suited for frequency domain multiplexing allowing $\sim$1000s of devices to be readout with one pair of coaxial cables. However, this moves the complexity of the detector from the cryogenics to the warm electronics. We present here the concept and experimental demonstration of the use of Fast Fourier Transform Spectrometer (FFTS) readout, showing no deterioration of the noise performance compared to low noise analog mixing while allowing high multiplexing ratios.
△ Less
Submitted 13 March, 2009;
originally announced March 2009.