Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–15 of 15 results for author: Lustig, M

Searching in archive cs. Search in all archives.
.
  1. arXiv:2405.02208  [pdf, other

    eess.IV cs.CV

    Reference-Free Image Quality Metric for Degradation and Reconstruction Artifacts

    Authors: Han Cui, Alfredo De Goyeneche, Efrat Shimron, Boyuan Ma, Michael Lustig

    Abstract: Image Quality Assessment (IQA) is essential in various Computer Vision tasks such as image deblurring and super-resolution. However, most IQA methods require reference images, which are not always available. While there are some reference-free IQA metrics, they have limitations in simulating human perception and discerning subtle image quality variations. We hypothesize that the JPEG quality facto… ▽ More

    Submitted 1 May, 2024; originally announced May 2024.

  2. arXiv:2308.02958  [pdf, other

    eess.IV cs.CV cs.LG eess.SP physics.med-ph

    K-band: Self-supervised MRI Reconstruction via Stochastic Gradient Descent over K-space Subsets

    Authors: Frederic Wang, Han Qi, Alfredo De Goyeneche, Reinhard Heckel, Michael Lustig, Efrat Shimron

    Abstract: Although deep learning (DL) methods are powerful for solving inverse problems, their reliance on high-quality training data is a major hurdle. This is significant in high-dimensional (dynamic/volumetric) magnetic resonance imaging (MRI), where acquisition of high-resolution fully sampled k-space data is impractical. We introduce a novel mathematical framework, dubbed k-band, that enables training… ▽ More

    Submitted 23 May, 2024; v1 submitted 5 August, 2023; originally announced August 2023.

  3. arXiv:2212.10817  [pdf, other

    eess.IV cs.CV

    High-fidelity Direct Contrast Synthesis from Magnetic Resonance Fingerprinting

    Authors: Ke Wang, Mariya Doneva, Jakob Meineke, Thomas Amthor, Ekin Karasan, Fei Tan, Jonathan I. Tamir, Stella X. Yu, Michael Lustig

    Abstract: Magnetic Resonance Fingerprinting (MRF) is an efficient quantitative MRI technique that can extract important tissue and system parameters such as T1, T2, B0, and B1 from a single scan. This property also makes it attractive for retrospectively synthesizing contrast-weighted images. In general, contrast-weighted images like T1-weighted, T2-weighted, etc., can be synthesized directly from parameter… ▽ More

    Submitted 21 December, 2022; originally announced December 2022.

    Comments: 19 pages, 8 figures

  4. arXiv:2109.08237  [pdf, other

    cs.LG

    Subtle Data Crimes: Naively training machine learning algorithms could lead to overly-optimistic results

    Authors: Efrat Shimron, Jonathan I. Tamir, Ke Wang, Michael Lustig

    Abstract: While open databases are an important resource in the Deep Learning (DL) era, they are sometimes used "off-label": data published for one task are used for training algorithms for a different one. This work aims to highlight that in some cases, this common practice may lead to biased, overly-optimistic results. We demonstrate this phenomenon for inverse problem solvers and show how their biased pe… ▽ More

    Submitted 14 December, 2021; v1 submitted 16 September, 2021; originally announced September 2021.

    Comments: 16 pages, 7 figures, two tables. Submitted to a journal

  5. arXiv:2108.12460  [pdf, other

    eess.IV cs.CV eess.SP

    High Fidelity Deep Learning-based MRI Reconstruction with Instance-wise Discriminative Feature Matching Loss

    Authors: Ke Wang, Jonathan I Tamir, Alfredo De Goyeneche, Uri Wollner, Rafi Brada, Stella Yu, Michael Lustig

    Abstract: Purpose: To improve reconstruction fidelity of fine structures and textures in deep learning (DL) based reconstructions. Methods: A novel patch-based Unsupervised Feature Loss (UFLoss) is proposed and incorporated into the training of DL-based reconstruction frameworks in order to preserve perceptual similarity and high-order statistics. The UFLoss provides instance-level discrimination by mappi… ▽ More

    Submitted 27 August, 2021; originally announced August 2021.

    Comments: 35 pages, 13 figures

  6. arXiv:2103.04003  [pdf, other

    eess.IV cs.CV

    Memory-efficient Learning for High-Dimensional MRI Reconstruction

    Authors: Ke Wang, Michael Kellman, Christopher M. Sandino, Kevin Zhang, Shreyas S. Vasanawala, Jonathan I. Tamir, Stella X. Yu, Michael Lustig

    Abstract: Deep learning (DL) based unrolled reconstructions have shown state-of-the-art performance for under-sampled magnetic resonance imaging (MRI). Similar to compressed sensing, DL can leverage high-dimensional data (e.g. 3D, 2D+time, 3D+time) to further improve performance. However, network size and depth are currently limited by the GPU memory required for backpropagation. Here we use a memory-effici… ▽ More

    Submitted 5 March, 2021; originally announced March 2021.

    Comments: 14 pages, 8 figures

  7. arXiv:2005.13531  [pdf, other

    eess.IV cs.CV eess.SP

    How to do Physics-based Learning

    Authors: Michael Kellman, Michael Lustig, Laura Waller

    Abstract: The goal of this tutorial is to explain step-by-step how to implement physics-based learning for the rapid prototyping of a computational imaging system. We provide a basic overview of physics-based learning, the construction of a physics-based network, and its reduction to practice. Specifically, we advocate exploiting the auto-differentiation functionality twice, once to build a physics-based ne… ▽ More

    Submitted 28 May, 2020; v1 submitted 27 May, 2020; originally announced May 2020.

    Comments: 3 pages, 2 figures, linked repository https://github.com/kellman/physics_based_learning

  8. arXiv:2003.05551  [pdf, other

    cs.CV cs.LG eess.IV eess.SP stat.ML

    Memory-efficient Learning for Large-scale Computational Imaging

    Authors: Michael Kellman, Kevin Zhang, Jon Tamir, Emrah Bostan, Michael Lustig, Laura Waller

    Abstract: Critical aspects of computational imaging systems, such as experimental design and image priors, can be optimized through deep networks formed by the unrolled iterations of classical model-based reconstructions (termed physics-based networks). However, for real-world large-scale inverse problems, computing gradients via backpropagation is infeasible due to memory limitations of graphics processing… ▽ More

    Submitted 11 March, 2020; originally announced March 2020.

    Comments: 9 pages, 8 figures. See also relate NeurIPS 2019 presentation arXiv:1912.05098

  9. arXiv:1912.05098  [pdf, other

    eess.IV cs.LG eess.SP

    Memory-efficient Learning for Large-scale Computational Imaging -- NeurIPS deep inverse workshop

    Authors: Michael Kellman, Jon Tamir, Emrah Boston, Michael Lustig, Laura Waller

    Abstract: Computational imaging systems jointly design computation and hardware to retrieve information which is not traditionally accessible with standard imaging systems. Recently, critical aspects such as experimental design and image priors are optimized through deep neural networks formed by the unrolled iterations of classical physics-based reconstructions (termed physics-based networks). However, for… ▽ More

    Submitted 11 March, 2020; v1 submitted 10 December, 2019; originally announced December 2019.

    Comments: 5 pages, 2 figures, presented at NeurIPS 2019 Deep Inverse workshop

  10. arXiv:1809.04195  [pdf, other

    physics.med-ph cs.CV cs.DC

    Clinically Deployed Distributed Magnetic Resonance Imaging Reconstruction: Application to Pediatric Knee Imaging

    Authors: Michael J. Anderson, Jonathan I. Tamir, Javier S. Turek, Marcus T. Alley, Theodore L. Willke, Shreyas S. Vasanawala, Michael Lustig

    Abstract: Magnetic resonance imaging is capable of producing volumetric images without ionizing radiation. Nonetheless, long acquisitions lead to prohibitively long exams. Compressed sensing (CS) can enable faster scanning via sub-sampling with reduced artifacts. However, CS requires significantly higher reconstruction computation, limiting current clinical applications to 2D/3D or limited-resolution dynami… ▽ More

    Submitted 11 September, 2018; originally announced September 2018.

    MSC Class: 68W15; 68U10

  11. arXiv:1709.05374  [pdf, other

    cs.CV physics.med-ph

    General Phase Regularized Reconstruction using Phase Cycling

    Authors: Frank Ong, Joseph Cheng, Michael Lustig

    Abstract: Purpose: To develop a general phase regularized image reconstruction method, with applications to partial Fourier imaging, water-fat imaging and flow imaging. Theory and Methods: The problem of enforcing phase constraints in reconstruction was studied under a regularized inverse problem framework. A general phase regularized reconstruction algorithm was proposed to enable various joint reconstru… ▽ More

    Submitted 15 September, 2017; originally announced September 2017.

  12. arXiv:1707.00070  [pdf, other

    cs.CV

    Better than Real: Complex-valued Neural Nets for MRI Fingerprinting

    Authors: Patrick Virtue, Stella X. Yu, Michael Lustig

    Abstract: The task of MRI fingerprinting is to identify tissue parameters from complex-valued MRI signals. The prevalent approach is dictionary based, where a test MRI signal is compared to stored MRI signals with known tissue parameters and the most similar signals and tissue parameters retrieved. Such an approach does not scale with the number of parameters and is rather slow when the tissue parameter spa… ▽ More

    Submitted 30 June, 2017; originally announced July 2017.

    Comments: Accepted in Proc. IEEE International Conference on Image Processing (ICIP), 2017

  13. arXiv:1610.00410  [pdf, other

    cs.CV cs.IT physics.med-ph

    On the Empirical Effect of Gaussian Noise in Under-sampled MRI Reconstruction

    Authors: Patrick Virtue, Michael Lustig

    Abstract: In Fourier-based medical imaging, sampling below the Nyquist rate results in an underdetermined system, in which linear reconstructions will exhibit artifacts. Another consequence of under-sampling is lower signal to noise ratio (SNR) due to fewer acquired measurements. Even if an oracle provided the information to perfectly disambiguate the underdetermined system, the reconstructed image could st… ▽ More

    Submitted 3 October, 2016; originally announced October 2016.

    Comments: 24 pages, 7 figures

  14. arXiv:1509.03557  [pdf, other

    cs.CV cs.CE physics.med-ph

    Estimating Absolute-Phase Maps Using ESPIRiT and Virtual Conjugate Coils

    Authors: Martin Uecker, Michael Lustig

    Abstract: Purpose: To develop an ESPIRiT-based method to estimate coil sensitivities with image phase as a building block for efficient and robust image reconstruction with phase constraints. Theory and Methods: ESPIRiT is a new framework for calibration of the coil sensitivities and reconstruction in parallel Magnetic Resonance Imaging (MRI). Applying ESPIRiT to a combined set of physical and virtual conju… ▽ More

    Submitted 5 January, 2016; v1 submitted 17 July, 2015; originally announced September 2015.

    Comments: 15 pages, 5 figures

    Journal ref: Magnetic Resonance in Medicine 77 (2017) 1201-1207

  15. arXiv:1507.08751  [pdf, other

    eess.SY cs.IT math.NA math.OC

    Beyond Low Rank + Sparse: Multi-scale Low Rank Matrix Decomposition

    Authors: Frank Ong, Michael Lustig

    Abstract: We present a natural generalization of the recent low rank + sparse matrix decomposition and consider the decomposition of matrices into components of multiple scales. Such decomposition is well motivated in practice as data matrices often exhibit local correlations in multiple scales. Concretely, we propose a multi-scale low rank modeling that represents a data matrix as a sum of block-wise low r… ▽ More

    Submitted 3 August, 2016; v1 submitted 31 July, 2015; originally announced July 2015.