-
Advancing Multimodal Medical Capabilities of Gemini
Authors:
Lin Yang,
Shawn Xu,
Andrew Sellergren,
Timo Kohlberger,
Yuchen Zhou,
Ira Ktena,
Atilla Kiraly,
Faruk Ahmed,
Farhad Hormozdiari,
Tiam Jaroensri,
Eric Wang,
Ellery Wulczyn,
Fayaz Jamil,
Theo Guidroz,
Chuck Lau,
Siyuan Qiao,
Yun Liu,
Akshay Goel,
Kendall Park,
Arnav Agharwal,
Nick George,
Yang Wang,
Ryutaro Tanno,
David G. T. Barrett,
Wei-Hung Weng
, et al. (22 additional authors not shown)
Abstract:
Many clinical tasks require an understanding of specialized data, such as medical images and genomics, which is not typically found in general-purpose large multimodal models. Building upon Gemini's multimodal models, we develop several models within the new Med-Gemini family that inherit core capabilities of Gemini and are optimized for medical use via fine-tuning with 2D and 3D radiology, histop…
▽ More
Many clinical tasks require an understanding of specialized data, such as medical images and genomics, which is not typically found in general-purpose large multimodal models. Building upon Gemini's multimodal models, we develop several models within the new Med-Gemini family that inherit core capabilities of Gemini and are optimized for medical use via fine-tuning with 2D and 3D radiology, histopathology, ophthalmology, dermatology and genomic data. Med-Gemini-2D sets a new standard for AI-based chest X-ray (CXR) report generation based on expert evaluation, exceeding previous best results across two separate datasets by an absolute margin of 1% and 12%, where 57% and 96% of AI reports on normal cases, and 43% and 65% on abnormal cases, are evaluated as "equivalent or better" than the original radiologists' reports. We demonstrate the first ever large multimodal model-based report generation for 3D computed tomography (CT) volumes using Med-Gemini-3D, with 53% of AI reports considered clinically acceptable, although additional research is needed to meet expert radiologist reporting quality. Beyond report generation, Med-Gemini-2D surpasses the previous best performance in CXR visual question answering (VQA) and performs well in CXR classification and radiology VQA, exceeding SoTA or baselines on 17 of 20 tasks. In histopathology, ophthalmology, and dermatology image classification, Med-Gemini-2D surpasses baselines across 18 out of 20 tasks and approaches task-specific model performance. Beyond imaging, Med-Gemini-Polygenic outperforms the standard linear polygenic risk score-based approach for disease risk prediction and generalizes to genetically correlated diseases for which it has never been trained. Although further development and evaluation are necessary in the safety-critical medical domain, our results highlight the potential of Med-Gemini across a wide range of medical tasks.
△ Less
Submitted 6 May, 2024;
originally announced May 2024.
-
Consensus, dissensus and synergy between clinicians and specialist foundation models in radiology report generation
Authors:
Ryutaro Tanno,
David G. T. Barrett,
Andrew Sellergren,
Sumedh Ghaisas,
Sumanth Dathathri,
Abigail See,
Johannes Welbl,
Karan Singhal,
Shekoofeh Azizi,
Tao Tu,
Mike Schaekermann,
Rhys May,
Roy Lee,
SiWai Man,
Zahra Ahmed,
Sara Mahdavi,
Yossi Matias,
Joelle Barral,
Ali Eslami,
Danielle Belgrave,
Vivek Natarajan,
Shravya Shetty,
Pushmeet Kohli,
Po-Sen Huang,
Alan Karthikesalingam
, et al. (1 additional authors not shown)
Abstract:
Radiology reports are an instrumental part of modern medicine, informing key clinical decisions such as diagnosis and treatment. The worldwide shortage of radiologists, however, restricts access to expert care and imposes heavy workloads, contributing to avoidable errors and delays in report delivery. While recent progress in automated report generation with vision-language models offer clear pote…
▽ More
Radiology reports are an instrumental part of modern medicine, informing key clinical decisions such as diagnosis and treatment. The worldwide shortage of radiologists, however, restricts access to expert care and imposes heavy workloads, contributing to avoidable errors and delays in report delivery. While recent progress in automated report generation with vision-language models offer clear potential in ameliorating the situation, the path to real-world adoption has been stymied by the challenge of evaluating the clinical quality of AI-generated reports. In this study, we build a state-of-the-art report generation system for chest radiographs, $\textit{Flamingo-CXR}$, by fine-tuning a well-known vision-language foundation model on radiology data. To evaluate the quality of the AI-generated reports, a group of 16 certified radiologists provide detailed evaluations of AI-generated and human written reports for chest X-rays from an intensive care setting in the United States and an inpatient setting in India. At least one radiologist (out of two per case) preferred the AI report to the ground truth report in over 60$\%$ of cases for both datasets. Amongst the subset of AI-generated reports that contain errors, the most frequently cited reasons were related to the location and finding, whereas for human written reports, most mistakes were related to severity and finding. This disparity suggested potential complementarity between our AI system and human experts, prompting us to develop an assistive scenario in which Flamingo-CXR generates a first-draft report, which is subsequently revised by a clinician. This is the first demonstration of clinician-AI collaboration for report writing, and the resultant reports are assessed to be equivalent or preferred by at least one radiologist to reports written by experts alone in 80$\%$ of in-patient cases and 60$\%$ of intensive care cases.
△ Less
Submitted 20 December, 2023; v1 submitted 30 November, 2023;
originally announced November 2023.
-
Synthetically Enhanced: Unveiling Synthetic Data's Potential in Medical Imaging Research
Authors:
Bardia Khosravi,
Frank Li,
Theo Dapamede,
Pouria Rouzrokh,
Cooper U. Gamble,
Hari M. Trivedi,
Cody C. Wyles,
Andrew B. Sellergren,
Saptarshi Purkayastha,
Bradley J. Erickson,
Judy W. Gichoya
Abstract:
Chest X-rays (CXR) are the most common medical imaging study and are used to diagnose multiple medical conditions. This study examines the impact of synthetic data supplementation, using diffusion models, on the performance of deep learning (DL) classifiers for CXR analysis. We employed three datasets: CheXpert, MIMIC-CXR, and Emory Chest X-ray, training conditional denoising diffusion probabilist…
▽ More
Chest X-rays (CXR) are the most common medical imaging study and are used to diagnose multiple medical conditions. This study examines the impact of synthetic data supplementation, using diffusion models, on the performance of deep learning (DL) classifiers for CXR analysis. We employed three datasets: CheXpert, MIMIC-CXR, and Emory Chest X-ray, training conditional denoising diffusion probabilistic models (DDPMs) to generate synthetic frontal radiographs. Our approach ensured that synthetic images mirrored the demographic and pathological traits of the original data. Evaluating the classifiers' performance on internal and external datasets revealed that synthetic data supplementation enhances model accuracy, particularly in detecting less prevalent pathologies. Furthermore, models trained on synthetic data alone approached the performance of those trained on real data. This suggests that synthetic data can potentially compensate for real data shortages in training robust DL models. However, despite promising outcomes, the superiority of real data persists.
△ Less
Submitted 15 November, 2023;
originally announced November 2023.
-
ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Authors:
Shawn Xu,
Lin Yang,
Christopher Kelly,
Marcin Sieniek,
Timo Kohlberger,
Martin Ma,
Wei-Hung Weng,
Atilla Kiraly,
Sahar Kazemzadeh,
Zakkai Melamed,
Jungyeon Park,
Patricia Strachan,
Yun Liu,
Chuck Lau,
Preeti Singh,
Christina Chen,
Mozziyar Etemadi,
Sreenivasa Raju Kalidindi,
Yossi Matias,
Katherine Chou,
Greg S. Corrado,
Shravya Shetty,
Daniel Tse,
Shruthi Prabhakara,
Daniel Golden
, et al. (3 additional authors not shown)
Abstract:
In this work, we present an approach, which we call Embeddings for Language/Image-aligned X-Rays, or ELIXR, that leverages a language-aligned image encoder combined or grafted onto a fixed LLM, PaLM 2, to perform a broad range of chest X-ray tasks. We train this lightweight adapter architecture using images paired with corresponding free-text radiology reports from the MIMIC-CXR dataset. ELIXR ach…
▽ More
In this work, we present an approach, which we call Embeddings for Language/Image-aligned X-Rays, or ELIXR, that leverages a language-aligned image encoder combined or grafted onto a fixed LLM, PaLM 2, to perform a broad range of chest X-ray tasks. We train this lightweight adapter architecture using images paired with corresponding free-text radiology reports from the MIMIC-CXR dataset. ELIXR achieved state-of-the-art performance on zero-shot chest X-ray (CXR) classification (mean AUC of 0.850 across 13 findings), data-efficient CXR classification (mean AUCs of 0.893 and 0.898 across five findings (atelectasis, cardiomegaly, consolidation, pleural effusion, and pulmonary edema) for 1% (~2,200 images) and 10% (~22,000 images) training data), and semantic search (0.76 normalized discounted cumulative gain (NDCG) across nineteen queries, including perfect retrieval on twelve of them). Compared to existing data-efficient methods including supervised contrastive learning (SupCon), ELIXR required two orders of magnitude less data to reach similar performance. ELIXR also showed promise on CXR vision-language tasks, demonstrating overall accuracies of 58.7% and 62.5% on visual question answering and report quality assurance tasks, respectively. These results suggest that ELIXR is a robust and versatile approach to CXR AI.
△ Less
Submitted 7 September, 2023; v1 submitted 2 August, 2023;
originally announced August 2023.
-
Deep Learning for Distinguishing Normal versus Abnormal Chest Radiographs and Generalization to Unseen Diseases
Authors:
Zaid Nabulsi,
Andrew Sellergren,
Shahar Jamshy,
Charles Lau,
Edward Santos,
Atilla P. Kiraly,
Wenxing Ye,
Jie Yang,
Rory Pilgrim,
Sahar Kazemzadeh,
Jin Yu,
Sreenivasa Raju Kalidindi,
Mozziyar Etemadi,
Florencia Garcia-Vicente,
David Melnick,
Greg S. Corrado,
Lily Peng,
Krish Eswaran,
Daniel Tse,
Neeral Beladia,
Yun Liu,
Po-Hsuan Cameron Chen,
Shravya Shetty
Abstract:
Chest radiography (CXR) is the most widely-used thoracic clinical imaging modality and is crucial for guiding the management of cardiothoracic conditions. The detection of specific CXR findings has been the main focus of several artificial intelligence (AI) systems. However, the wide range of possible CXR abnormalities makes it impractical to build specific systems to detect every possible conditi…
▽ More
Chest radiography (CXR) is the most widely-used thoracic clinical imaging modality and is crucial for guiding the management of cardiothoracic conditions. The detection of specific CXR findings has been the main focus of several artificial intelligence (AI) systems. However, the wide range of possible CXR abnormalities makes it impractical to build specific systems to detect every possible condition. In this work, we developed and evaluated an AI system to classify CXRs as normal or abnormal. For development, we used a de-identified dataset of 248,445 patients from a multi-city hospital network in India. To assess generalizability, we evaluated our system using 6 international datasets from India, China, and the United States. Of these datasets, 4 focused on diseases that the AI was not trained to detect: 2 datasets with tuberculosis and 2 datasets with coronavirus disease 2019. Our results suggest that the AI system generalizes to new patient populations and abnormalities. In a simulated workflow where the AI system prioritized abnormal cases, the turnaround time for abnormal cases reduced by 7-28%. These results represent an important step towards evaluating whether AI can be safely used to flag cases in a general setting where previously unseen abnormalities exist.
△ Less
Submitted 29 October, 2021; v1 submitted 21 October, 2020;
originally announced October 2020.