Solid State Detectors and Tracking for Snowmass
Authors:
A. Affolder,
A. Apresyan,
S. Worm,
M. Albrow,
D. Ally,
D. Ambrose,
E. Anderssen,
N. Apadula,
P. Asenov,
W. Armstrong,
M. Artuso,
A. Barbier,
P. Barletta,
L. Bauerdick,
D. Berry,
M. Bomben,
M. Boscardin,
J. Brau,
W. Brooks,
M. Breidenbach,
J. Buckley,
V. Cairo,
R. Caputo,
L. Carpenter,
M. Centis-Vignali
, et al. (110 additional authors not shown)
Abstract:
Tracking detectors are of vital importance for collider-based high energy physics (HEP) experiments. The primary purpose of tracking detectors is the precise reconstruction of charged particle trajectories and the reconstruction of secondary vertices. The performance requirements from the community posed by the future collider experiments require an evolution of tracking systems, necessitating the…
▽ More
Tracking detectors are of vital importance for collider-based high energy physics (HEP) experiments. The primary purpose of tracking detectors is the precise reconstruction of charged particle trajectories and the reconstruction of secondary vertices. The performance requirements from the community posed by the future collider experiments require an evolution of tracking systems, necessitating the development of new techniques, materials and technologies in order to fully exploit their physics potential. In this article we summarize the discussions and conclusions of the 2022 Snowmass Instrumentation Frontier subgroup on Solid State and Tracking Detectors (Snowmass IF03).
△ Less
Submitted 19 October, 2022; v1 submitted 8 September, 2022;
originally announced September 2022.
-
Novel Sensors for Particle Tracking: a Contribution to the Snowmass Community Planning Exercise of 2021
Authors:
M. R. Hoeferkamp,
S. Seidel,
S. Kim,
J. Metcalfe,
A. Sumant,
H. Kagan,
W. Trischuk,
M. Boscardin,
G. -F. Dalla Betta,
D. M. S. Sultan,
N. T. Fourches,
C. Renard,
A. Barbier,
T. Mahajan,
A. Minns,
V. Tokranov,
M. Yakimov,
S. Oktyabrsky,
C. Gingu,
P. Murat,
M. T. Hedges
Abstract:
Five contemporary technologies are discussed in the context of their potential roles in particle tracking for future high energy physics applications. These include sensors of the 3D configuration, in both diamond and silicon, submicron-dimension pixels, thin film detectors, and scintillating quantum dots in gallium arsenide. Drivers of the technologies include radiation hardness, excellent positi…
▽ More
Five contemporary technologies are discussed in the context of their potential roles in particle tracking for future high energy physics applications. These include sensors of the 3D configuration, in both diamond and silicon, submicron-dimension pixels, thin film detectors, and scintillating quantum dots in gallium arsenide. Drivers of the technologies include radiation hardness, excellent position, vertex, and timing resolution, simplified integration, and optimized power, cost, and material.
△ Less
Submitted 23 February, 2022;
originally announced February 2022.
-
Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
F. Alam Khan,
M. Alhusseini,
J. Alison,
A. Alpana,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Bannerjee,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (364 additional authors not shown)
Abstract:
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glu…
▽ More
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1 cm$^2$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.
△ Less
Submitted 31 March, 2022; v1 submitted 12 November, 2021;
originally announced November 2021.
-
A reconfigurable neural network ASIC for detector front-end data compression at the HL-LHC
Authors:
Giuseppe Di Guglielmo,
Farah Fahim,
Christian Herwig,
Manuel Blanco Valentin,
Javier Duarte,
Cristian Gingu,
Philip Harris,
James Hirschauer,
Martin Kwok,
Vladimir Loncar,
Yingyi Luo,
Llovizna Miranda,
Jennifer Ngadiuba,
Daniel Noonan,
Seda Ogrenci-Memik,
Maurizio Pierini,
Sioni Summers,
Nhan Tran
Abstract:
Despite advances in the programmable logic capabilities of modern trigger systems, a significant bottleneck remains in the amount of data to be transported from the detector to off-detector logic where trigger decisions are made. We demonstrate that a neural network autoencoder model can be implemented in a radiation tolerant ASIC to perform lossy data compression alleviating the data transmission…
▽ More
Despite advances in the programmable logic capabilities of modern trigger systems, a significant bottleneck remains in the amount of data to be transported from the detector to off-detector logic where trigger decisions are made. We demonstrate that a neural network autoencoder model can be implemented in a radiation tolerant ASIC to perform lossy data compression alleviating the data transmission problem while preserving critical information of the detector energy profile. For our application, we consider the high-granularity calorimeter from the CMS experiment at the CERN Large Hadron Collider. The advantage of the machine learning approach is in the flexibility and configurability of the algorithm. By changing the neural network weights, a unique data compression algorithm can be deployed for each sensor in different detector regions, and changing detector or collider conditions. To meet area, performance, and power constraints, we perform a quantization-aware training to create an optimized neural network hardware implementation. The design is achieved through the use of high-level synthesis tools and the hls4ml framework, and was processed through synthesis and physical layout flows based on a LP CMOS 65 nm technology node. The flow anticipates 200 Mrad of ionizing radiation to select gates, and reports a total area of 3.6 mm^2 and consumes 95 mW of power. The simulated energy consumption per inference is 2.4 nJ. This is the first radiation tolerant on-detector ASIC implementation of a neural network that has been designed for particle physics applications.
△ Less
Submitted 4 May, 2021;
originally announced May 2021.
-
Construction and commissioning of CMS CE prototype silicon modules
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
As part of its HL-LHC upgrade program, the CMS Collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modul…
▽ More
As part of its HL-LHC upgrade program, the CMS Collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modules have been constructed with 6-inch hexagonal silicon sensors with cell areas of 1.1~$cm^2$, and the SKIROC2-CMS readout ASIC. Beam tests of different sampling configurations were conducted with the prototype modules at DESY and CERN in 2017 and 2018. This paper describes the construction and commissioning of the CE calorimeter prototype, the silicon modules used in the construction, their basic performance, and the methods used for their calibration.
△ Less
Submitted 10 December, 2020;
originally announced December 2020.
-
The DAQ system of the 12,000 Channel CMS High Granularity Calorimeter Prototype
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endca…
▽ More
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ${\approx}12,000\rm{~channels}$ of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry PI computers.
△ Less
Submitted 8 December, 2020; v1 submitted 7 December, 2020;
originally announced December 2020.
-
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
Authors:
M. Dragicevic,
M. Friedl,
J. Hrubec,
H. Steininger,
A. Gädda,
J. Härkönen,
T. Lampén,
P. Luukka,
T. Peltola,
E. Tuominen,
E. Tuovinen,
A. Winkler,
P. Eerola,
T. Tuuva,
G. Baulieu,
G. Boudoul,
L. Caponetto,
C. Combaret,
D. Contardo,
T. Dupasquier,
G. Gallbit,
N. Lumb,
L. Mirabito,
S. Perries,
M. Vander Donckt
, et al. (462 additional authors not shown)
Abstract:
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator…
▽ More
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,μ\mathrm{m}$ and $7.99\pm0.21\,μ\mathrm{m}$ along the $100\,μ\mathrm{m}$ and $150\,μ\mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.
△ Less
Submitted 1 June, 2017;
originally announced June 2017.
-
MINERvA neutrino detector response measured with test beam data
Authors:
MINERvA Collaboration,
L. Aliaga,
O. Altinok,
C. Araujo Del Castillo,
L. Bagby,
L. Bellantoni,
W. F. Bergan,
A. Bodek,
R. Bradford,
A. Bravar,
H. Budd,
A. Butkevich,
D. A. Martinez Caicedo,
M. F. Carneiro,
M. E. Christy,
J. Chvojka,
H. da Motta,
J. Devan,
G. A. Diaz,
S. A. Dytman,
B. Eberly,
J. Felix,
L. Fields,
R. Fine,
R. Flight
, et al. (63 additional authors not shown)
Abstract:
The MINERvA collaboration operated a scaled-down replica of the solid scintillator tracking and sampling calorimeter regions of the MINERvA detector in a hadron test beam at the Fermilab Test Beam Facility. This article reports measurements with samples of protons, pions, and electrons from 0.35 to 2.0 GeV/c momentum. The calorimetric response to protons, pions, and electrons are obtained from the…
▽ More
The MINERvA collaboration operated a scaled-down replica of the solid scintillator tracking and sampling calorimeter regions of the MINERvA detector in a hadron test beam at the Fermilab Test Beam Facility. This article reports measurements with samples of protons, pions, and electrons from 0.35 to 2.0 GeV/c momentum. The calorimetric response to protons, pions, and electrons are obtained from these data. A measurement of the parameter in Birks' law and an estimate of the tracking efficiency are extracted from the proton sample. Overall the data are well described by a Geant4-based Monte Carlo simulation of the detector and particle interactions with agreements better than 4%, though some features of the data are not precisely modeled. These measurements are used to tune the MINERvA detector simulation and evaluate systematic uncertainties in support of the MINERvA neutrino cross section measurement program.
△ Less
Submitted 7 April, 2015; v1 submitted 26 January, 2015;
originally announced January 2015.
-
The PHENIX Forward Silicon Vertex Detector
Authors:
C. Aidala,
L. Anaya,
E. Anderssen,
A. Bambaugh,
A. Barron,
J. G. Boissevain,
J. Bok,
S. Boose,
M. L. Brooks,
S. Butsyk,
M. Cepeda,
P. Chacon,
S. Chacon,
L. Chavez,
T. Cote,
C. D'Agostino,
A. Datta,
K. DeBlasio,
L. DelMonte,
E. J. Desmond,
J. M. Durham,
D. Fields,
M. Finger,
C. Gingu,
B. Gonzales
, et al. (60 additional authors not shown)
Abstract:
A new silicon detector has been developed to provide the PHENIX experiment with precise charged particle tracking at forward and backward rapidity. The Forward Silicon Vertex Tracker (FVTX) was installed in PHENIX prior to the 2012 run period of the Relativistic Heavy Ion Collider (RHIC). The FVTX is composed of two annular endcaps, each with four stations of silicon mini-strip sensors, covering a…
▽ More
A new silicon detector has been developed to provide the PHENIX experiment with precise charged particle tracking at forward and backward rapidity. The Forward Silicon Vertex Tracker (FVTX) was installed in PHENIX prior to the 2012 run period of the Relativistic Heavy Ion Collider (RHIC). The FVTX is composed of two annular endcaps, each with four stations of silicon mini-strip sensors, covering a rapidity range of $1.2<|η|<2.2$ that closely matches the two existing PHENIX muon arms. Each station consists of 48 individual silicon sensors, each of which contains two columns of mini-strips with 75 $μ$m pitch in the radial direction and lengths in the $φ$ direction varying from 3.4 mm at the inner radius to 11.5 mm at the outer radius. The FVTX has approximately 0.54 million strips in each endcap. These are read out with FPHX chips, developed in collaboration with Fermilab, which are wire bonded directly to the mini-strips. The maximum strip occupancy reached in central Au-Au collisions is approximately 2.8%. The precision tracking provided by this device makes the identification of muons from secondary vertices away from the primary event vertex possible. The expected distance of closest approach (DCA) resolution of 200 $μ$m or better for particles with a transverse momentum of 5 GeV/$c$ will allow identification of muons from relatively long-lived particles, such as $D$ and $B$ mesons, through their broader DCA distributions.
△ Less
Submitted 14 February, 2014; v1 submitted 14 November, 2013;
originally announced November 2013.
-
Design, Calibration, and Performance of the MINERvA Detector
Authors:
L. Aliaga,
L. Bagby,
B. Baldin,
A. Baumbaugh,
A. Bodek,
R. Bradford,
W. K. Brooks,
D. Boehnlein,
S. Boyd,
H. Budd,
A. Butkevich,
D. A. Martinez Caicedo,
C. M. Castromonte,
M. E. Christy,
J. Chvojka,
H. da Motta,
D. S. Damiani,
I. Danko,
M. Datta,
R. DeMaat,
J. Devan,
E. Draeger,
S. A. Dytman,
G. A. Diaz,
B. Eberly
, et al. (80 additional authors not shown)
Abstract:
The MINERvA experiment is designed to perform precision studies of neutrino-nucleus scattering using $ν_μ$ and ${\barν}_μ$ neutrinos incident at 1-20 GeV in the NuMI beam at Fermilab. This article presents a detailed description of the \minerva detector and describes the {\em ex situ} and {\em in situ} techniques employed to characterize the detector and monitor its performance. The detector is co…
▽ More
The MINERvA experiment is designed to perform precision studies of neutrino-nucleus scattering using $ν_μ$ and ${\barν}_μ$ neutrinos incident at 1-20 GeV in the NuMI beam at Fermilab. This article presents a detailed description of the \minerva detector and describes the {\em ex situ} and {\em in situ} techniques employed to characterize the detector and monitor its performance. The detector is comprised of a finely-segmented scintillator-based inner tracking region surrounded by electromagnetic and hadronic sampling calorimetry. The upstream portion of the detector includes planes of graphite, iron and lead interleaved between tracking planes to facilitate the study of nuclear effects in neutrino interactions. Observations concerning the detector response over sustained periods of running are reported. The detector design and methods of operation have relevance to future neutrino experiments in which segmented scintillator tracking is utilized.
△ Less
Submitted 22 May, 2013;
originally announced May 2013.
-
Measurement of Muon Neutrino Quasi-Elastic Scattering on a Hydrocarbon Target at E_ν ~ 3.5 GeV
Authors:
The MINERvA collaboration,
G. A. Fiorentini,
D. W. Schmitz,
P. A. Rodrigues,
L. Aliaga,
O. Altinok,
B. Baldin,
A. Baumbaugh,
A. Bodek,
D. Boehnlein,
S. Boyd,
R. Bradford,
W. K. Brooks,
H. Budd,
A. Butkevich,
D. A. Martinez Caicedo,
C. M. Castromonte,
M. E. Christy,
H. Chung,
J. Chvojka,
M. Clark,
H. da Motta,
D. S. Damiani,
I. Danko,
M. Datta
, et al. (93 additional authors not shown)
Abstract:
We report a study of muon neutrino charged-current quasi-elastic events in the segmented scintillator inner tracker of the MINERvA experiment running in the NuMI neutrino beam at Fermilab. The events were selected by requiring a μ^- and low calorimetric recoil energy separated from the interaction vertex. We measure the flux-averaged differential cross-section, dσ/dQ^2, and study the low energy pa…
▽ More
We report a study of muon neutrino charged-current quasi-elastic events in the segmented scintillator inner tracker of the MINERvA experiment running in the NuMI neutrino beam at Fermilab. The events were selected by requiring a μ^- and low calorimetric recoil energy separated from the interaction vertex. We measure the flux-averaged differential cross-section, dσ/dQ^2, and study the low energy particle content of the final state. Deviations are found between the measured dσ/dQ^2 and the expectations of a model of independent nucleons in a relativistic Fermi gas. We also observe an excess of energy near the vertex consistent with multiple protons in the final state.
△ Less
Submitted 30 March, 2014; v1 submitted 9 May, 2013;
originally announced May 2013.
-
Measurement of Muon Antineutrino Quasi-Elastic Scattering on a Hydrocarbon Target at E_ν ~ 3.5 GeV
Authors:
The MINERvA collaboration,
L. Fields,
J. Chvojka,
L. Aliaga,
O. Altinok,
B. Baldin,
A. Baumbaugh,
A. Bodek,
D. Boehnlein,
S. Boyd,
R. Bradford,
W. K. Brooks,
H. Budd,
A. Butkevich,
D. A. Martinez Caicedo,
C. M. Castromonte,
M. E. Christy,
H. Chung,
M. Clark,
H. da Motta,
D. S. Damiani,
I. Danko,
M. Datta,
M. Day,
R. DeMaat
, et al. (93 additional authors not shown)
Abstract:
We have isolated muon anti-neutrino charged-current quasi-elastic interactions occurring in the segmented scintillator tracking region of the MINERvA detector running in the NuMI neutrino beam at Fermilab. We measure the flux-averaged differential cross-section, dσ/dQ^2, and compare to several theoretical models of quasi-elastic scattering. Good agreement is obtained with a model where the nucleon…
▽ More
We have isolated muon anti-neutrino charged-current quasi-elastic interactions occurring in the segmented scintillator tracking region of the MINERvA detector running in the NuMI neutrino beam at Fermilab. We measure the flux-averaged differential cross-section, dσ/dQ^2, and compare to several theoretical models of quasi-elastic scattering. Good agreement is obtained with a model where the nucleon axial mass, M_A, is set to 0.99 GeV/c^2 but the nucleon vector form factors are modified to account for the observed enhancement, relative to the free nucleon case, of the cross-section for the exchange of transversely polarized photons in electron-nucleus scattering. Our data at higher Q^2 favor this interpretation over an alternative in which the axial mass is increased.
△ Less
Submitted 30 March, 2014; v1 submitted 9 May, 2013;
originally announced May 2013.
-
The MINER$ν$A Data Acquisition System and Infrastructure
Authors:
G. N. Perdue,
L. Bagby,
B. Baldin,
C. Gingu,
J. Olsen,
P. Rubinov,
E. C. Schulte,
R. Bradford,
W. K. Brooks,
D. A. M. Caicedo,
C. M. Castromonte,
J. Chvojka,
H. da Motta,
I. Danko,
J. Devan,
B. Eberly,
J. Felix,
L. Fields,
G. A. Fiorentini,
A. M. Gago,
R. Gran,
D. A. Harris,
K. Hurtado,
H. Lee,
E. Maher
, et al. (18 additional authors not shown)
Abstract:
MINER$ν$A (Main INjector ExpeRiment $ν$-A) is a new few-GeV neutrino cross section experiment that began taking data in the FNAL NuMI (Fermi National Accelerator Laboratory Neutrinos at the Main Injector) beam-line in March of 2010. MINER$ν$A employs a fine-grained scintillator detector capable of complete kinematic characterization of neutrino interactions. This paper describes the MINER$ν$A data…
▽ More
MINER$ν$A (Main INjector ExpeRiment $ν$-A) is a new few-GeV neutrino cross section experiment that began taking data in the FNAL NuMI (Fermi National Accelerator Laboratory Neutrinos at the Main Injector) beam-line in March of 2010. MINER$ν$A employs a fine-grained scintillator detector capable of complete kinematic characterization of neutrino interactions. This paper describes the MINER$ν$A data acquisition system (DAQ) including the read-out electronics, software, and computing architecture.
△ Less
Submitted 5 September, 2012;
originally announced September 2012.