-
First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
Authors:
J. Aalbers,
D. S. Akerib,
C. W. Akerlof,
A. K. Al Musalhi,
F. Alder,
A. Alqahtani,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
S. Azadi,
A. J. Bailey,
A. Baker,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
M. J. Barry,
J. Barthel,
D. Bauer,
A. Baxter
, et al. (322 additional authors not shown)
Abstract:
The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis s…
▽ More
The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis shows the data to be consistent with a background-only hypothesis, setting new limits on spin-independent WIMP-nucleon, spin-dependent WIMP-neutron, and spin-dependent WIMP-proton cross sections for WIMP masses above 9 GeV/c$^2$. The most stringent limit is set for spin-independent scattering at 36 GeV/c$^2$, rejecting cross sections above 9.2$\times 10^{-48}$ cm$^2$ at the 90% confidence level.
△ Less
Submitted 2 August, 2023; v1 submitted 8 July, 2022;
originally announced July 2022.
-
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
S. Aviles,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame,
J. Bensinger
, et al. (365 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent…
▽ More
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.
△ Less
Submitted 28 February, 2022; v1 submitted 3 June, 2020;
originally announced June 2020.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
Extending light WIMP searches to single scintillation photons in LUX
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
L. de Viveiros,
A. Dobi
, et al. (100 additional authors not shown)
Abstract:
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its…
▽ More
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.
△ Less
Submitted 27 December, 2019; v1 submitted 14 July, 2019;
originally announced July 2019.
-
Search for annual and diurnal rate modulations in the LUX experiment
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
T. J. R. Davison,
E. Druszkiewicz,
S. R. Fallon,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
J. Genovesi,
C. Ghag
, et al. (71 additional authors not shown)
Abstract:
Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calen…
▽ More
Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and developing robust cuts and corrections, we obtained a stable event rate of 2.3$\pm$0.2~cpd/keV$_{\text{ee}}$/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26~keV$_{\text{ee}}$. Between 2 and 6~keV$_{\text{ee}}$, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2$σ$ tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2~cpd/keV$_{\text{ee}}$/tonne amplitude between 2 and 6~keV$_{\text{ee}}$.
△ Less
Submitted 27 September, 2018; v1 submitted 18 July, 2018;
originally announced July 2018.
-
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
Authors:
D. S. Akerib,
C. W. Akerlof,
S. K. Alsum,
H. M. Araújo,
M. Arthurs,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
D. Bauer,
J. Belle,
P. Beltrame,
T. Benson,
E. P. Bernard,
T. P. Biesiadzinski,
K. E. Boast,
B. Boxer,
P. Brás,
J. H. Buckley,
V. V. Bugaev,
S. Burdin,
J. K. Busenitz,
C. Carels,
D. L. Carlsmith,
B. Carlson
, et al. (153 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7~tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up…
▽ More
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7~tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector.
For a 1000~live day run using a 5.6~tonne fiducial mass, LZ is projected to exclude at 90\% confidence level spin-independent WIMP-nucleon cross sections above $1.4 \times 10^{-48}$~cm$^{2}$ for a 40~$\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5σ$ discovery potential is projected reaching cross sections below the exclusion limits of recent experiments. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.3 \times 10^{-43}$~cm$^{2}$ ($7.1 \times 10^{-42}$~cm$^{2}$) for a 40~$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020.
△ Less
Submitted 2 December, 2019; v1 submitted 16 February, 2018;
originally announced February 2018.
-
Position Reconstruction in LUX
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
E. Druszkiewicz,
B. N. Edwards,
S. R. Fallon,
A. Fan
, et al. (69 additional authors not shown)
Abstract:
The $(x, y)$ position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional fo…
▽ More
The $(x, y)$ position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional form to account for the photons reflected on the inner walls of the detector. To increase the resolution for small pulses, a photon counting technique was employed to describe the response of the PMTs. The reconstruction was assessed with calibration data including ${}^{\mathrm{83m}}$Kr (releasing a total energy of 41.5 keV) and ${}^{3}$H ($β^-$ with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron beam (2.45 MeV). In the horizontal plane, the reconstruction has achieved an $(x, y)$ position uncertainty of $σ$= 0.82 cm for events of only 200 electroluminescence photons and $σ$ = 0.17 cm for 4,000 electroluminescence photons. Such signals are associated with electron recoils of energies $\sim$0.25 keV and $\sim$10 keV, respectively. The reconstructed position of the smallest events with a single electron emitted from the liquid surface has a horizontal $(x, y)$ uncertainty of 2.13 cm.
△ Less
Submitted 12 March, 2018; v1 submitted 7 October, 2017;
originally announced October 2017.
-
Ultra-Low Energy Calibration of LUX Detector using $^{127}$Xe Electron Capture
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
E. Druszkiewicz,
B. N. Edwards,
S. R. Fallon,
A. Fan
, et al. (69 additional authors not shown)
Abstract:
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in sea…
▽ More
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The sequence of gamma-ray and X-ray cascades associated with $^{127}$I de-excitations produces clearly identified 2-vertex events in the LUX detector. We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and N- (186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. The N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil $\textit{in situ}$ measurements that have been explored in liquid xenon.
△ Less
Submitted 3 September, 2017;
originally announced September 2017.
-
3D Modeling of Electric Fields in the LUX Detector
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
E. Druszkiewicz,
B. N. Edwards,
S. R. Fallon,
A. Fan
, et al. (69 additional authors not shown)
Abstract:
This work details the development of a three-dimensional (3D) electric field model for the LUX detector. The detector took data during two periods of searching for weakly interacting massive particle (WIMP) searches. After the first period completed, a time-varying non-uniform negative charge developed in the polytetrafluoroethylene (PTFE) panels that define the radial boundary of the detector's a…
▽ More
This work details the development of a three-dimensional (3D) electric field model for the LUX detector. The detector took data during two periods of searching for weakly interacting massive particle (WIMP) searches. After the first period completed, a time-varying non-uniform negative charge developed in the polytetrafluoroethylene (PTFE) panels that define the radial boundary of the detector's active volume. This caused electric field variations in the detector in time, depth and azimuth, generating an electrostatic radially-inward force on electrons on their way upward to the liquid surface. To map this behavior, 3D electric field maps of the detector's active volume were built on a monthly basis. This was done by fitting a model built in COMSOL Multiphysics to the uniformly distributed calibration data that were collected on a regular basis. The modeled average PTFE charge density increased over the course of the exposure from -3.6 to $-5.5~μ$C/m$^2$. From our studies, we deduce that the electric field magnitude varied while the mean value of the field of $\sim200$~V/cm remained constant throughout the exposure. As a result of this work the varying electric fields and their impact on event reconstruction and discrimination were successfully modeled.
△ Less
Submitted 27 November, 2017; v1 submitted 31 August, 2017;
originally announced September 2017.
-
LUX-ZEPLIN (LZ) Technical Design Report
Authors:
B. J. Mount,
S. Hans,
R. Rosero,
M. Yeh,
C. Chan,
R. J. Gaitskell,
D. Q. Huang,
J. Makkinje,
D. C. Malling,
M. Pangilinan,
C. A. Rhyne,
W. C. Taylor,
J. R. Verbus,
Y. D. Kim,
H. S. Lee,
J. Lee,
D. S. Leonard,
J. Li,
J. Belle,
A. Cottle,
W. H. Lippincott,
D. J. Markley,
T. J. Martin,
M. Sarychev,
T. E. Tope
, et al. (237 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
△ Less
Submitted 27 March, 2017;
originally announced March 2017.
-
Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
I. J. Arnquist,
M. Arthurs,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
J. Belle,
P. Beltrame,
T. Benson,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. Bolozdynya,
B. Boxer,
R. Bramante,
P. Brás,
J. H. Buckley,
V. V. Bugaev
, et al. (180 additional authors not shown)
Abstract:
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals,…
▽ More
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals, the determination of factors limiting radiopure production, and the selection of titanium for construction of the LZ cryostat and other detector components. This titanium has been measured with activities of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg, $^{232}$Th$_{e}$~$=0.28\pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25\pm 0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68\% CL). Such low intrinsic activities, which are some of the lowest ever reported for titanium, enable its use for future dark matter and other rare event searches. Monte Carlo simulations have been performed to assess the expected background contribution from the LZ cryostat with this radioactivity. In 1,000 days of WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute only a mean background of $0.160\pm0.001$(stat)$\pm0.030$(sys) counts.
△ Less
Submitted 26 September, 2017; v1 submitted 8 February, 2017;
originally announced February 2017.
-
Signal yields, energy resolution, and recombination fluctuations in liquid xenon
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
R. Bramante,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
J. E. Y. Dobson,
E. Druszkiewicz
, et al. (76 additional authors not shown)
Abstract:
This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light yields for electronic recoil energies between 5.2 and 661.7 keV are measured, as well as the energy resolution for the LUX detector at those same energies. Additiona…
▽ More
This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light yields for electronic recoil energies between 5.2 and 661.7 keV are measured, as well as the energy resolution for the LUX detector at those same energies. Additionally, there is an interpretation of existing measurements and descriptions of electron-ion recombination fluctuations in liquid xenon as limiting cases of a more general liquid xenon re- combination fluctuation model. Measurements of the standard deviation of these fluctuations at monoenergetic electronic recoil peaks exhibit a linear dependence on the number of ions for energy deposits up to 661.7 keV, consistent with previous LUX measurements between 2-16 keV with $^3$H. We highlight similarities in liquid xenon recombination for electronic and nuclear recoils with a comparison of recombination fluctuations measured with low-energy calibration data.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.
-
Results from a search for dark matter in the complete LUX exposure
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
R. Bramante,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
J. E. Y. Dobson,
E. Druszkiewicz
, et al. (76 additional authors not shown)
Abstract:
We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high…
▽ More
We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high WIMP masses relative to our previous results, this search yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV/c^2, WIMP-nucleon spin-independent cross sections above 2.2e-46 cm^2 are excluded at the 90% confidence level. When combined with the previously reported LUX exposure, this exclusion strengthens to 1.1e-46 cm^2 at 50 GeV/c^2.
△ Less
Submitted 13 January, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison
, et al. (82 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. T…
▽ More
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. The nuclear recoil energy from the first neutron scatter in the TPC was reconstructed using the measured scattering angle defined by double-scatter neutron events within the active xenon volume. We measured the absolute charge ($Q_{y}$) and light ($L_{y}$) yields at an average electric field of 180 V/cm for nuclear recoil energies spanning 0.7 to 74 keV and 1.1 to 74 keV, respectively. This calibration of the nuclear recoil signal yields will permit the further refinement of liquid xenon nuclear recoil signal models and, importantly for dark matter searches, clearly demonstrates measured ionization and scintillation signals in this medium at recoil energies down to $\mathcal{O}$(1 keV).
△ Less
Submitted 26 October, 2016; v1 submitted 18 August, 2016;
originally announced August 2016.
-
Proposed low-energy absolute calibration of nuclear recoils in a dual-phase noble element TPC using D-D neutron scattering kinematics
Authors:
J. R. Verbus,
C. A. Rhyne,
D. C. Malling,
M. Genecov,
S. Ghosh,
A. G. Moskowitz,
S. Chan,
J. J. Chapman,
L. de Viveiros,
C. H. Faham,
S. Fiorucci,
D. Q. Huang,
M. Pangilinan,
W. C. Taylor,
R. J. Gaitskell
Abstract:
We propose a new technique for the calibration of nuclear recoils in large noble element dual-phase time projection chambers used to search for WIMP dark matter in the local galactic halo. This technique provides an $\textit{in situ}$ measurement of the low-energy nuclear recoil response of the target media using the measured scattering angle between multiple neutron interactions within the detect…
▽ More
We propose a new technique for the calibration of nuclear recoils in large noble element dual-phase time projection chambers used to search for WIMP dark matter in the local galactic halo. This technique provides an $\textit{in situ}$ measurement of the low-energy nuclear recoil response of the target media using the measured scattering angle between multiple neutron interactions within the detector volume. The low-energy reach and reduced systematics of this calibration have particular significance for the low-mass WIMP sensitivity of several leading dark matter experiments. Multiple strategies for improving this calibration technique are discussed, including the creation of a new type of quasi-monoenergetic 272 keV neutron source. We report results from a time-of-flight based measurement of the neutron energy spectrum produced by an Adelphi Technology, Inc. DD108 neutron generator, confirming its suitability for the proposed nuclear recoil calibration.
△ Less
Submitted 18 August, 2016;
originally announced August 2016.
-
Results on the Spin-Dependent Scattering of Weakly Interacting Massive Particles on Nucleons from the Run 3 Data of the LUX Experiment
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
L. de Viveiros,
A. Dobi,
J. E. Y. Dobson
, et al. (77 additional authors not shown)
Abstract:
We present the first experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), which is designed to observe the recoil signature of galactic WIMPs scattering from xenon nuclei. A profile likelihood ratio analysis of…
▽ More
We present the first experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), which is designed to observe the recoil signature of galactic WIMPs scattering from xenon nuclei. A profile likelihood ratio analysis of $1.4~\times~10^{4}~\text{kg}\cdot~\text{days}$ of fiducial exposure allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of $σ_n~=~9.4~\times~10^{-41}~\text{cm}^2$ ($σ_p~=~2.9~\times~10^{-39}~\text{cm}^2$) at 33 GeV/c$^2$. The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
△ Less
Submitted 16 May, 2016; v1 submitted 10 February, 2016;
originally announced February 2016.
-
Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
L. de Viveiros,
A. Dobi,
J. E. Y. Dobson
, et al. (77 additional authors not shown)
Abstract:
We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background…
▽ More
We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background model including events originating on the detector walls in an enlarged fiducial volume, and new calibrations from decays of an injected tritium $β$ source and from kinematically constrained nuclear recoils down to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to our previous results which modeled the signal only above a 3 keV minimum energy. Under standard dark matter halo assumptions and in the mass range above 4 $\mathrm{GeV}\,c^{-2}$, these new results give the most stringent direct limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper limit has a minimum of 0.6 zb at 33 $\mathrm{GeV}\,c^{-2}$ WIMP mass.
△ Less
Submitted 16 May, 2016; v1 submitted 10 December, 2015;
originally announced December 2015.
-
Tritium calibration of the LUX dark matter experiment
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
L. de Viveiros,
A. Dobi,
J. E. Y. Dobson
, et al. (76 additional authors not shown)
Abstract:
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and compare the resu…
▽ More
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and compare the results to the NEST model. We also measure the mean charge recombination fraction and its fluctuations, and we investigate the location and width of the LUX ER band. These results provide input to a re-analysis of the LUX Run3 WIMP search.
△ Less
Submitted 5 May, 2016; v1 submitted 9 December, 2015;
originally announced December 2015.
-
LUX-ZEPLIN (LZ) Conceptual Design Report
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
P. Bauer,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. I. Bolozdynya,
E. M. Boulton,
R. Bramante,
J. H. Buckley,
V. V. Bugaev,
R. Bunker,
S. Burdin,
J. K. Busenitz
, et al. (170 additional authors not shown)
Abstract:
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp…
▽ More
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.
△ Less
Submitted 23 September, 2015; v1 submitted 9 September, 2015;
originally announced September 2015.
-
A Detailed Look at the First Results from the Large Underground Xenon (LUX) Dark Matter Experiment
Authors:
M. Szydagis,
D. S. Akerib,
H. M. Araujo,
X. Bai,
A. J. Bailey,
J. Balajthy,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
T. Coffey,
A. Currie,
L. de Viveiros,
A. Dobi,
J. Dobson,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci
, et al. (55 additional authors not shown)
Abstract:
LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive direct dark matter search experiment. The initial null-result limit on the spin-independent WIMP-nucleon scattering cross-section was released in October 2013, with a primary scintillation threshold of 2 phe, roughly 3 keV…
▽ More
LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive direct dark matter search experiment. The initial null-result limit on the spin-independent WIMP-nucleon scattering cross-section was released in October 2013, with a primary scintillation threshold of 2 phe, roughly 3 keVnr for LUX. The detector has been deployed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, and is the first experiment to achieve a limit on the WIMP cross-section lower than $10^{-45}$ cm$^{2}$. Here we present a more in-depth discussion of the novel energy scale employed to better understand the nuclear recoil light and charge yields, and of the calibration sources, including the new internal tritium source. We found the LUX data to be in conflict with low-mass WIMP signal interpretations of other results.
△ Less
Submitted 25 February, 2014; v1 submitted 15 February, 2014;
originally announced February 2014.
-
First results from the LUX dark matter experiment at the Sanford Underground Research Facility
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araujo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bolozdynya,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
K. Clark,
T. Coffey,
A. Currie,
A. Curioni,
S. Dazeley,
L. de Viveiros,
A. Dobi
, et al. (78 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-li…
▽ More
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-likelihood analysis technique shows our data to be consistent with the background-only hypothesis, allowing 90% confidence limits to be set on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33 GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass WIMP signal interpretations of the results from several recent direct detection experiments.
△ Less
Submitted 5 February, 2014; v1 submitted 30 October, 2013;
originally announced October 2013.
-
The Large Underground Xenon (LUX) Experiment
Authors:
D. S. Akerib,
X. Bai,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bolozdynya,
A. Bradley,
D. Byram,
S. B. Cahn,
C. Camp,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
A. Chiller,
C. Chiller,
K. Clark,
T. Classen,
T. Coffey,
A. Curioni,
E. Dahl,
S. Dazeley,
L. de Viveiros,
A. Dobi,
E. Dragowsky,
E. Druszkiewicz
, et al. (69 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMPs), a leading dark matter candidate. The goal of the LUX detector is to clearly detect (or exclude) WIMPS with a spin independent cross section per nucleon of $2\times 10^{-46}$ cm$^{2}$, equivalent to $\sim$1 event/100…
▽ More
The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMPs), a leading dark matter candidate. The goal of the LUX detector is to clearly detect (or exclude) WIMPS with a spin independent cross section per nucleon of $2\times 10^{-46}$ cm$^{2}$, equivalent to $\sim$1 event/100 kg/month in the inner 100-kg fiducial volume (FV) of the 370-kg detector. The overall background goals are set to have $<$1 background events characterized as possible WIMPs in the FV in 300 days of running.
This paper describes the design and construction of the LUX detector.
△ Less
Submitted 21 November, 2012; v1 submitted 15 November, 2012;
originally announced November 2012.
-
Technical Results from the Surface Run of the LUX Dark Matter Experiment
Authors:
LUX Collaboration,
D. S. Akerib,
X. Bai,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
J. J. Chapman,
T. Coffey,
A. Dobi,
E. Dragowsky,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
M. Gilchriese,
C. Hall,
M. Hanhardt,
M. Ihm,
R. G. Jacobsen,
L. Kastens
, et al. (42 additional authors not shown)
Abstract:
We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed i…
▽ More
We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed in a water tank, validated the integration of the various sub-systems in preparation of the underground deployment. Using the data collected, we report excellent light collection properties, achieving 8.4 photoelectrons per keV for 662 keV electron recoils without an applied electric field, measured in the center of the WIMP target. We also find good energy and position resolution in relatively high-energy interactions from a variety of internal and external sources. Finally, we have used the commissioning data to tune the optical properties of our simulation and report updated sensitivity projections for spin-independent WIMP-nucleon scattering.
△ Less
Submitted 22 February, 2013; v1 submitted 16 October, 2012;
originally announced October 2012.
-
An Ultra-Low Background PMT for Liquid Xenon Detectors
Authors:
D. S. Akerib,
X. Bai,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
Y-D. Chan,
K. Clark,
T. Coffey,
L. deViveiros,
M. Dragowsky,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
C. Hall,
M. Hanhardt,
B. Holbrook,
M. Ihm
, et al. (42 additional authors not shown)
Abstract:
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other det…
▽ More
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th / <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of \times1/25 after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.
△ Less
Submitted 24 June, 2013; v1 submitted 10 May, 2012;
originally announced May 2012.
-
Radio-assay of Titanium samples for the LUX Experiment
Authors:
D. S. Akerib,
X. Bai,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bradley,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
Y-D. Chan,
K. Clark,
T. Classen,
T. Coffey,
S. Dazeley,
L. deViveiros,
M. Dragowsky,
E. Druszkiewicz,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
C. Hall,
M. Hanhardt,
B. Holbrook
, et al. (41 additional authors not shown)
Abstract:
We report on the screening of samples of titanium metal for their radio-purity. The screening process described in this work led to the selection of materials used in the construction of the cryostats for the Large Underground Xenon (LUX) dark matter experiment. Our measurements establish titanium as a highly desirable material for low background experiments searching for rare events. The sample w…
▽ More
We report on the screening of samples of titanium metal for their radio-purity. The screening process described in this work led to the selection of materials used in the construction of the cryostats for the Large Underground Xenon (LUX) dark matter experiment. Our measurements establish titanium as a highly desirable material for low background experiments searching for rare events. The sample with the lowest total long-lived activity was measured to contain <0.25 mBq/kg of U-238, <0.2 mBq/kg of Th-232, and <1.2 mBq/kg of K-40. Measurements of several samples also indicated the presence of short-lived (84 day half life) Sc-46, likely produced cosmogenically via muon initiated (n,p) reactions.
△ Less
Submitted 12 February, 2012; v1 submitted 6 December, 2011;
originally announced December 2011.
-
LUXSim: A Component-Centric Approach to Low-Background Simulations
Authors:
D. S. Akerib,
X. Bai,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bradley,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
K. Clark,
T. Classen,
T. Coffey,
S. Dazeley,
L. de Viveiros,
M. Dragowsky,
E. Druszkiewicz,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
C. Hall,
M. Hanhardt,
B. Holbrook,
M. Ihm
, et al. (38 additional authors not shown)
Abstract:
Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpo…
▽ More
Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpoint, there is no single source or beam, but rather a collection of sources with potentially complicated spatial extent. LUXSim is a simulation framework used by the LUX collaboration that takes a component-centric approach to event generation and recording. A new set of classes allows for multiple radioactive sources to be set within any number of components at run time, with the entire collection of sources handled within a single simulation run. Various levels of information can also be recorded from the individual components, with these record levels also being set at runtime. This flexibility in both source generation and information recording is possible without the need to recompile, reducing the complexity of code management and the proliferation of versions. Within the code itself, casting geometry objects within this new set of classes rather than as the default Geant4 classes automatically extends this flexibility to every individual component. No additional work is required on the part of the developer, reducing development time and increasing confidence in the results. We describe the guiding principles behind LUXSim, detail some of its unique classes and methods, and give examples of usage.
* Corresponding author, kareem@llnl.gov
△ Less
Submitted 8 November, 2011;
originally announced November 2011.