Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–5 of 5 results for author: Bhaskar, P

Searching in archive physics. Search in all archives.
.
  1. arXiv:2405.20187  [pdf, other

    physics.ins-det cond-mat.mes-hall cond-mat.mtrl-sci cond-mat.other cond-mat.supr-con

    An Ultra-High Vacuum Scanning Tunneling Microscope with Pulse Tube and Joule-Thomson cooling operating at sub-pm z-noise

    Authors: Marcus Eßer, Marco Pratzer, Marc Frömming, Jonas Duffhauß, Priyamvada Bhaskar, Michael A. Krzyzowski, Markus Morgenstern

    Abstract: We describe a compact ultra-high vacuum (UHV) scanning tunneling microscope (STM) system that does not need any external supply of cooling liquids. It achieves temperatures down to 1.5 K and a z-noise down to 300 fmRMS for the frequency range of 0.1 Hz - 5 kHz (feedback loop off). It employs a pulse tube cryocooler (PTC) and a Joule-Thomson (JT) stage inducing only small temperature oscillations a… ▽ More

    Submitted 30 May, 2024; originally announced May 2024.

    Comments: 12 pages, 8 figures

  2. arXiv:2012.10386  [pdf

    physics.ao-ph physics.geo-ph

    Future Climate Change Projections over the Indian Region

    Authors: J. Sanjay, R. Krishnan, M. V. S. Ramarao, R. Mahesh, Bhupendra Bahadur Singh, Jayashri Patel, Sandip Ingle, Preethi Bhaskar, J. V. Revadekar, T. P. Sabin, M. Mujumdar

    Abstract: Assessments of impacts of climate change and future projections over the Indian region, have so far relied on a single regional climate model (RCM) - eg., the PRECIS RCM of the Hadley Centre, UK. While these assessments have provided inputs to various reports (e.g., INCCA 2010; NATCOMM2 2012), it is important to have an ensemble of climate projections drawn from multiple RCMs due to large uncertai… ▽ More

    Submitted 2 December, 2020; originally announced December 2020.

    Comments: "17 pages, chapter in Climate Change over INDIA: An Interim Report (2017), pp 11-27; see http://cccr.tropmet.res.in/home/docs/cccr/climate-change-report-2017.pdf"

    Journal ref: Climate Change over INDIA: An Interim Report (2017), pp 11-27

  3. arXiv:2012.10385  [pdf

    physics.ao-ph

    Large Scale Features of Southwest Monsoon During 2015

    Authors: Hamza Varikoden, Bhupendra Bahadur Singh, K. P. Sooraj, Manish K. Joshi, Preethi Bhaskar, Milind Mujumdar, M. Rajeevan

    Abstract: During 2015, the southwest monsoon (SWM) rainfall over the country remained deficient with seasonal rainfall of about 86% of the long period average (Table 1.1). Last year, the seasonal rainfall deficiency over the country as a whole was 12% (www.imd.gov.in). Thus, this is a fourth episode of two consecutive years, with deficient monsoon, similar to 1904-05, 1965-66 and 1986-87 (www.imd.gov.in).

    Submitted 2 December, 2020; originally announced December 2020.

    Comments: "12 pages, chapter in A Research Report on the 2015 Southwest Monsoon (2015), pp 2-13; see https://www.tropmet.res.in/~lip/Publication/RR-pdf/RR-185.pdf"

    Journal ref: ESSO/IITM/SERP/SR/02(2015)/185, pp 2-13

  4. arXiv:2012.03484  [pdf, ps, other

    physics.ins-det nucl-ex

    Detailed investigation on the possibility of using EJ-299-33A plastic scintillator for fast neutron spectroscopy in large scale experiments

    Authors: Pratap Roy, K. Banerjee, A. K. Saha, C. Bhattacharya, J. K. Meenaa, P. Bhaskar, S. Mukhopadhyay, S. Bhattacharya

    Abstract: Detailed characterization of the newly available plastic scintillator (EJ-299-33A) having the pulse shape discrimination (PSD) property has been carried out in case of a large-sized detector (5 in.$\times$5 in.). The pulse height response of the scintillator for nearly mono-energetic neutrons has been reported in case of neutron energies E$_n$ =3, 6 and 9 MeV. Important properties (figure-of-merit… ▽ More

    Submitted 7 December, 2020; originally announced December 2020.

    Journal ref: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 901 (2018), Pages 198-202, ISSN 0168-9002

  5. arXiv:1801.02540  [pdf, other

    physics.app-ph cond-mat.mes-hall

    Mask aligner for ultrahigh vacuum with capacitive distance control

    Authors: Priyamvada Bhaskar, Simon Mathioudakis, Tim Olschewski, Florian Muckel, Jan Raphael Bindel, Marco Pratzer, Marcus Liebmann, Markus Morgenstern

    Abstract: We present a mask aligner driven by three piezo motors which guides and aligns a SiN shadow mask under capacitive control towards a sample surface. The three capacitors for read out are located at the backside of the thin mask such that the mask can be placed in $μ$m distance from the sample surface, while keeping it parallel to the surface. Samples and masks can be exchanged in-situ and the mask… ▽ More

    Submitted 8 January, 2018; originally announced January 2018.

    Comments: 5 pages, 3 figures