-
COHERENT Collaboration data release from the measurements of CsI[Na] response to nuclear recoils
Authors:
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri,
M. P. Green
, et al. (53 additional authors not shown)
Abstract:
Description of the data release 10.13139/OLCF/1969085 (https://doi.ccs.ornl.gov/ui/doi/426) from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHERENT collaboration. The release corresponds to the results published in "D. Akimov et al 2022 JINST 17 P10034". We share the data in the form of raw ADC waveforms, provide benchmark values, and share plots to enhance the…
▽ More
Description of the data release 10.13139/OLCF/1969085 (https://doi.ccs.ornl.gov/ui/doi/426) from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHERENT collaboration. The release corresponds to the results published in "D. Akimov et al 2022 JINST 17 P10034". We share the data in the form of raw ADC waveforms, provide benchmark values, and share plots to enhance the transparency and reproducibility of our results. This document describes the contents of the data release as well as guidance on the use of the data.
△ Less
Submitted 14 July, 2023;
originally announced July 2023.
-
The COHERENT Experimental Program
Authors:
D. Akimov,
S. Alawabdeh,
P. An,
A. Arteaga,
C. Awe,
P. S. Barbeau,
C. Barry,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
L. Blokland,
C. Bock,
B. Bodur,
A. Bolozdynya,
R. Bouabid,
A. Bracho,
J. Browning,
B. Cabrera-Palmer,
N. Chen,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Daughtry,
E. Day
, et al. (106 additional authors not shown)
Abstract:
The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies o…
▽ More
The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies of inelastic neutrino-nucleus interactions, searches for accelerator-produced dark matter (DM) and physics beyond the Standard Model, using the uniquely high-quality and high-intensity neutrino source available at the SNS. This white paper describes primarily COHERENT's ongoing and near-future program at the SNS First Target Station (FTS). Opportunities enabled by the SNS Second Target Station (STS) for the study of neutrino physics and development of novel detector technologies are elaborated in a separate white paper.
△ Less
Submitted 9 April, 2022;
originally announced April 2022.
-
Monitoring the SNS basement neutron background with the MARS detector
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri
, et al. (53 additional authors not shown)
Abstract:
We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the…
▽ More
We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. These data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be $1.20~\pm~0.56~\text{neutrons}/\text{m}^2/\text{MWh}$ for neutron energies above $\sim3.5$ MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.
△ Less
Submitted 14 April, 2022; v1 submitted 5 December, 2021;
originally announced December 2021.
-
Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT
Authors:
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri,
M. P. Green
, et al. (52 additional authors not shown)
Abstract:
We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at t…
▽ More
We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.
△ Less
Submitted 6 October, 2022; v1 submitted 3 November, 2021;
originally announced November 2021.
-
A D$_{2}$O detector for flux normalization of a pion decay-at-rest neutrino source
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
L. Blokland,
A. Bolozdynya,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
E. Day,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri
, et al. (54 additional authors not shown)
Abstract:
We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncerta…
▽ More
We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncertainty in 2 years. This heavy-water detector will serve as the first module of a two-module detector system to ultimately measure the neutrino flux to 2-3% at both the First Target Station and the planned Second Target Station of the SNS. This detector will significantly reduce a dominant systematic uncertainty for neutrino cross-section measurements at the SNS, increasing the sensitivity of searches for new physics.
△ Less
Submitted 25 August, 2021; v1 submitted 19 April, 2021;
originally announced April 2021.
-
Development of a $^{83\mathrm{m}}$Kr source for the calibration of the CENNS-10 Liquid Argon Detector
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
L. Blokland,
A. Bolozdynya,
B. Cabrera-Palmer,
N. Chen,
D. Chernyak,
E. Conley,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox,
A. Galindo-Uribarri
, et al. (55 additional authors not shown)
Abstract:
We report on the preparation of and calibration measurements with a $^{83\mathrm{m}}$Kr source for the CENNS-10 liquid argon detector. $^{83\mathrm{m}}$Kr atoms generated in the decay of a $^{83}$Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of $^{83\mathrm{m}}$Kr i…
▽ More
We report on the preparation of and calibration measurements with a $^{83\mathrm{m}}$Kr source for the CENNS-10 liquid argon detector. $^{83\mathrm{m}}$Kr atoms generated in the decay of a $^{83}$Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of $^{83\mathrm{m}}$Kr in the detector volume were then observed. This calibration source allows the characterization of the low-energy response of the CENNS-10 detector and is applicable to other low-energy-threshold detectors. The energy resolution of the detector was measured to be 9$\%$ at the total $^{83\mathrm{m}}$Kr decay energy of 41.5 keV. We performed an analysis to separately calibrate the detector using the two conversion electrons at 9.4 keV and 32.1 keV
△ Less
Submitted 27 January, 2021; v1 submitted 21 October, 2020;
originally announced October 2020.
-
Sensitivity of the COHERENT Experiment to Accelerator-Produced Dark Matter
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
A. Bolozdynya,
B. Cabrera-Palmer,
N. Chen,
E. Conley,
R. L. Cooper,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox,
A. Galindo-Uribarri,
M. P. Green,
K. S. Hansen
, et al. (53 additional authors not shown)
Abstract:
The COHERENT experiment is well poised to test sub-GeV dark matter models using low-energy recoil detectors sensitive to coherent elastic neutrino-nucleus scattering (CEvNS) in the $π$-DAR neutrino beam produced by the Spallation Neutron Source. We show how a planned 750-kg liquid argon scintillation detector would place leading limits on scalar light dark matter models, over two orders of magnitu…
▽ More
The COHERENT experiment is well poised to test sub-GeV dark matter models using low-energy recoil detectors sensitive to coherent elastic neutrino-nucleus scattering (CEvNS) in the $π$-DAR neutrino beam produced by the Spallation Neutron Source. We show how a planned 750-kg liquid argon scintillation detector would place leading limits on scalar light dark matter models, over two orders of magnitude of dark matter mass, for dark matter particles produced through vector and leptophobic portals in the absence of other effects beyond the standard model. The characteristic timing structure of a $π$-DAR beam allows a unique opportunity for constraining systematic uncertainties on the standard model background in a time window where signal is not expected, enhancing expected sensitivity. Additionally, we discuss future prospects, further increasing the discovery potential of CEvNS detectors. Such methods would test the calculated thermal dark matter abundance for all couplings $α'\leq1$ within the vector portal model over an order of magnitude of dark matter masses.
△ Less
Submitted 14 November, 2019;
originally announced November 2019.
-
COHERENT 2018 at the Spallation Neutron Source
Authors:
D. Akimov,
J. B. Albert,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
A. Bolozdynya,
A. Brown,
A. Burenkov,
B. Cabrera-Palmer,
M. Cervantes,
J. I. Collar,
R. J. Cooper,
R. L. Cooper,
J. Daughhetee,
D. J. Dean,
M. del Valle Coello,
J. A. Detwiler,
M. D'Onofrio,
Y. Efremenko,
S. R. Elliott,
E. Erkela,
A. Etenko
, et al. (54 additional authors not shown)
Abstract:
The primary goal of the COHERENT collaboration is to measure and study coherent elastic neutrino-nucleus scattering (CEvNS) using the high-power, few-tens-of-MeV, pulsed source of neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The COHERENT collaboration reported the first detection of CEvNS [Akimov:2017ade] using a CsI[Na] detector. At present th…
▽ More
The primary goal of the COHERENT collaboration is to measure and study coherent elastic neutrino-nucleus scattering (CEvNS) using the high-power, few-tens-of-MeV, pulsed source of neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The COHERENT collaboration reported the first detection of CEvNS [Akimov:2017ade] using a CsI[Na] detector. At present the collaboration is deploying four detector technologies: a CsI[Na] scintillating crystal, p-type point-contact germanium detectors, single-phase liquid argon, and NaI[Tl] crystals. All detectors are located in the neutron-quiet basement of the SNS target building at distances 20-30 m from the SNS neutrino source. The simultaneous measurement in all four COHERENT detector subsystems will test the $N^2$ dependence of the cross section and search for new physics. In addition, COHERENT is measuring neutrino-induced neutrons from charged- and neutral-current neutrino interactions on nuclei in shielding materials, which represent a non-negligible background for CEvNS as well as being of intrinsic interest. The Collaboration is planning as well to look for charged-current interactions of relevance to supernova and weak-interaction physics. This document describes concisely the COHERENT physics motivations, sensitivity, and next plans for measurements at the SNS to be accomplished on a few-year timescale.
△ Less
Submitted 2 April, 2018; v1 submitted 24 March, 2018;
originally announced March 2018.
-
In Beam Tests of Implanted Helium Targets
Authors:
J. E. McDonald,
R. H. France III,
R. A. Jarvis,
M. W. Ahmed,
M. A. Blackston,
Th. Delbar,
M. Gai,
T. J. Kading,
Y. Parpottas,
B. A. Perdue,
R. M. Prior,
D. A. Rubin,
M. C. Spraker,
J. D. Yeomans,
L. Weissman,
H. R. Weller,
E. L. Wilds Jr,
;,
UHartford,
GCSU,
LNS/UConn,
TUNL/Duke,
UCL/LLN,
Yale,
NGCSU
Abstract:
Targets consisting of 3,4He implanted into thin aluminum foils (approximately 100, 200 or 600 ug/cm^2) were prepared using intense (a few uA) helium beams at low energy (approximately 20, 40 or 100 keV). Uniformity of the implantation was achieved by a beam raster across a 12 mm diameter tantalum collimator at the rates of 0.1 Hz in the vertical direction and 1 Hz in the horizontal direction. He…
▽ More
Targets consisting of 3,4He implanted into thin aluminum foils (approximately 100, 200 or 600 ug/cm^2) were prepared using intense (a few uA) helium beams at low energy (approximately 20, 40 or 100 keV). Uniformity of the implantation was achieved by a beam raster across a 12 mm diameter tantalum collimator at the rates of 0.1 Hz in the vertical direction and 1 Hz in the horizontal direction. Helium implantation into the very thin (approximately 80-100 ug/cm^2) aluminum foils failed to produce useful targets (with only approximately 10% of the helium retained) due to an under estimation of the range by the code SRIM. The range of low energy helium in aluminum predicted by Northcliffe and Shilling and the NIST online tabulation are observed on the other hand to over estimate the range of low energy helium ions in aluminum. An attempt to increase the amount of helium by implanting a second deeper layer was also carried out, but it did not significantly increase the helium content beyond the blistering limit (approximately 6 x 10^17 helium/cm^2). The implanted targets were bombarded with moderately intense 4He and 16O beams of 50-100 particle nA . Rutherford Back Scattering of 1.0 and 2.5 MeV proton beams and recoil helium from 15.0 MeV oxygen beams were used to study the helium content and profile before, during and after bombardments. We observed the helium content and profile to be very stable even after a prolonged bombardment (up to two days) with moderately intense beams of 16O or 4He. Helium implanted into thin (aluminum) foils is a good choice for thin helium targets needed, for example, for a measurement of the 3he(a,g)7Be reaction and the associated S34 astrophysical cross section factor (S-factor).
△ Less
Submitted 16 August, 2006;
originally announced August 2006.