-
Three-sided pyramid wavefront sensor. II. Preliminary demonstration on the new CACTI testbed
Authors:
Lauren Schatz,
Johanan Codona,
Joseph D. Long,
Jared R. Males,
Weslin Pullen,
Jennifer Lumbres,
Kyle Van Gorkom,
Vincent Chambouleyron,
Laird M. Close,
Carlos Correia,
Olivier Fauvarque,
Thierry Fusco,
Olivier Guyon,
Michael Hart,
Pierre Janin-Potiron,
Robert Johnson,
Nemanja Jovanovic,
Mala Mateen,
Jean-Francois Sauvage,
Benoit Neichel
Abstract:
The next generation of giant ground and space telescopes will have the light-collecting power to detect and characterize potentially habitable terrestrial exoplanets using high-contrast imaging for the first time. This will only be achievable if the performance of Giant Segmented Mirror Telescopes (GSMTs) extreme adaptive optics (ExAO) systems are optimized to their full potential. A key component…
▽ More
The next generation of giant ground and space telescopes will have the light-collecting power to detect and characterize potentially habitable terrestrial exoplanets using high-contrast imaging for the first time. This will only be achievable if the performance of Giant Segmented Mirror Telescopes (GSMTs) extreme adaptive optics (ExAO) systems are optimized to their full potential. A key component of an ExAO system is the wavefront sensor (WFS), which measures aberrations from atmospheric turbulence. A common choice in current and next-generation instruments is the pyramid wavefront sensor (PWFS). ExAO systems require high spatial and temporal sampling of wavefronts to optimize performance, and as a result, require large detectors for the WFS. We present a closed-loop testbed demonstration of a three-sided pyramid wavefront sensor (3PWFS) as an alternative to the conventional four-sided pyramid wavefront (4PWFS) sensor for GSMT-ExAO applications on the new Comprehensive Adaptive Optics and Coronagraph Test Instrument (CACTI). The 3PWFS is less sensitive to read noise than the 4PWFS because it uses fewer detector pixels. The 3PWFS has further benefits: a high-quality three-sided pyramid optic is easier to manufacture than a four-sided pyramid. We detail the design of the two components of the CACTI system, the adaptive optics simulator and the PWFS testbed that includes both a 3PWFS and 4PWFS. A preliminary experiment was performed on CACTI to study the performance of the 3PWFS to the 4PWFS in varying strengths of turbulence using both the Raw Intensity and Slopes Map signal processing methods. This experiment was repeated for a modulation radius of 1.6 lambda/D and 3.25 lambda/D. We found that the performance of the two wavefront sensors is comparable if modal loop gains are tuned.
△ Less
Submitted 7 October, 2022;
originally announced October 2022.
-
Calibrating a high-resolution wavefront corrector with a static focal-plane camera
Authors:
Visa Korkiakoski,
Niek Doelman,
Johanan Codona,
Matthew Kenworthy,
Gilles Otten,
Christoph U. Keller
Abstract:
We present a method to calibrate a high-resolution wavefront-correcting device with a single, static camera, located in the focal plane; no moving of any component is needed. The method is based on a localized diversity and differential optical transfer functions (dOTF) to compute both the phase and amplitude in the pupil plane located upstream of the last imaging optics. An experiment with a spat…
▽ More
We present a method to calibrate a high-resolution wavefront-correcting device with a single, static camera, located in the focal plane; no moving of any component is needed. The method is based on a localized diversity and differential optical transfer functions (dOTF) to compute both the phase and amplitude in the pupil plane located upstream of the last imaging optics. An experiment with a spatial light modulator shows that the calibration is sufficient to robustly operate a focal-plane wavefront sensing algorithm controlling a wavefront corrector with ~40 000 degrees of freedom. We estimate that the locations of identical wavefront corrector elements are determined with a spatial resolution of 0.3% compared to the pupil diameter.
△ Less
Submitted 3 October, 2013;
originally announced October 2013.
-
Differential OTF Wavefront Sensing
Authors:
Johanan L. Codona
Abstract:
An image-based technique for measuring the complex field in the pupil of an imaging system is presented. Two point source images, one with a small modification introduced in the pupil, are combined using a simple and non-iterative algorithm. The non-interferometric method is based on the change in the optical transfer function (OTF), giving a differential OTF (dOTF). The dOTF includes two images o…
▽ More
An image-based technique for measuring the complex field in the pupil of an imaging system is presented. Two point source images, one with a small modification introduced in the pupil, are combined using a simple and non-iterative algorithm. The non-interferometric method is based on the change in the optical transfer function (OTF), giving a differential OTF (dOTF). The dOTF includes two images of the complex pupil field, conjugated and reflected about the position of the pupil modification, leaving an overlap that obscures some the the pupil. The overlap can be minimized by introducing the modification near the edge of the pupil. The overlap region can be eliminated altogether by using a second modification and a third point source image. The pupil field is convolved by the change in the pupil field, so smaller modification areas are preferred. The non-monochromatic light, but the result incurs a proportional radial blurring determined by the fractional bandwidth. We include some simple demonstration experiments, including using a pupil blockage and moving a single deformable mirror actuator as the pupil modification. In each case the complex wavefront is easily recovered, even when the pupil mask is unknown and the wavefront aberrations are large.
△ Less
Submitted 26 September, 2013;
originally announced September 2013.