Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–5 of 5 results for author: Delgado, D

Searching in archive physics. Search in all archives.
.
  1. arXiv:2405.16316  [pdf, other

    hep-ex physics.ins-det

    Search for reactor-produced millicharged particles with Skipper-CCDs at the CONNIE and Atucha-II experiments

    Authors: Alexis A. Aguilar-Arevalo, Nicolas Avalos, Pablo Bellino, Xavier Bertou, Carla Bonifazi, Ana Botti, Mariano Cababié, Gustavo Cancelo, Brenda A. Cervantes-Vergara, Claudio Chavez, Fernando Chierchie, David Delgado, Eliana Depaoli, Juan Carlos D'Olivo, João dos Anjos, Juan Estrada, Guillermo Fernandez Moroni, Aldo R. Fernandes Neto, Richard Ford, Ben Kilminster, Kevin Kuk, Andrew Lathrop, Patrick Lemos, Herman P. Lima Jr., Martin Makler , et al. (15 additional authors not shown)

    Abstract: Millicharged particles, proposed by various extensions of the standard model, can be created in pairs by high-energy photons within nuclear reactors and can interact electromagnetically with electrons in matter. Recently, the existence of a plasmon peak in the interaction cross-section with silicon in the eV range was highlighted as a promising approach to enhance low-energy sensitivities. The CON… ▽ More

    Submitted 25 May, 2024; originally announced May 2024.

    Comments: 9 pages, 3 figures

  2. arXiv:2404.19589  [pdf, other

    astro-ph.IM hep-ex physics.ins-det

    Acceptance Tests of more than 10 000 Photomultiplier Tubes for the multi-PMT Digital Optical Modules of the IceCube Upgrade

    Authors: R. Abbasi, M. Ackermann, J. Adams, S. K. Agarwalla, J. A. Aguilar, M. Ahlers, J. M. Alameddine, N. M. Amin, K. Andeen, C. Argüelles, Y. Ashida, S. Athanasiadou, L. Ausborm, S. N. Axani, X. Bai, A. Balagopal V., M. Baricevic, S. W. Barwick, S. Bash, V. Basu, R. Bay, J. J. Beatty, J. Becker Tjus, J. Beise, C. Bellenghi , et al. (399 additional authors not shown)

    Abstract: More than 10,000 photomultiplier tubes (PMTs) with a diameter of 80 mm will be installed in multi-PMT Digital Optical Modules (mDOMs) of the IceCube Upgrade. These have been tested and pre-calibrated at two sites. A throughput of more than 1000 PMTs per week with both sites was achieved with a modular design of the testing facilities and highly automated testing procedures. The testing facilities… ▽ More

    Submitted 20 June, 2024; v1 submitted 30 April, 2024; originally announced April 2024.

    Comments: 24 pages, 19 figures, 2 tables, submitted to JINST

  3. arXiv:2403.02470  [pdf, other

    astro-ph.HE astro-ph.IM physics.data-an

    Improved modeling of in-ice particle showers for IceCube event reconstruction

    Authors: R. Abbasi, M. Ackermann, J. Adams, S. K. Agarwalla, J. A. Aguilar, M. Ahlers, J. M. Alameddine, N. M. Amin, K. Andeen, G. Anton, C. Argüelles, Y. Ashida, S. Athanasiadou, L. Ausborm, S. N. Axani, X. Bai, A. Balagopal V., M. Baricevic, S. W. Barwick, S. Bash, V. Basu, R. Bay, J. J. Beatty, J. Becker Tjus, J. Beise , et al. (394 additional authors not shown)

    Abstract: The IceCube Neutrino Observatory relies on an array of photomultiplier tubes to detect Cherenkov light produced by charged particles in the South Pole ice. IceCube data analyses depend on an in-depth characterization of the glacial ice, and on novel approaches in event reconstruction that utilize fast approximations of photoelectron yields. Here, a more accurate model is derived for event reconstr… ▽ More

    Submitted 22 April, 2024; v1 submitted 4 March, 2024; originally announced March 2024.

    Comments: 28 pages, 18 figures, 1 table, submitted to JINST, updated to account for comments received

    Journal ref: 2024 JINST 19 P06026

  4. arXiv:2401.07885  [pdf, other

    hep-ex astro-ph.IM physics.ins-det

    Deployment and performance of a Low-Energy-Threshold Skipper-CCD inside a nuclear reactor

    Authors: E. Depaoli, D. Rodrigues, I. Sidelnik, P. Bellino, A. Botti, D. Delgado, M. Cababie, F. Chierchie, J. Estrada, G. Fernandez Moroni, S. Perez, J. Tiffenberg

    Abstract: Charge Coupled Devices (CCD) are used for reactor neutrino experiments and already shown their potential in constraining new physics models. The prospect of a Skipper-CCD experiment looking for standard and beyond standard model physics (BSM) in a nuclear reactor has been recently evaluated for different benchmark scenarios. Here we report the installation of the first 2 g Skipper-CCD inside the c… ▽ More

    Submitted 7 March, 2024; v1 submitted 15 January, 2024; originally announced January 2024.

    Comments: 12 pages, 7 figures, 1 table

  5. arXiv:2304.12236  [pdf, other

    hep-ex physics.ins-det

    Measurement of Atmospheric Neutrino Mixing with Improved IceCube DeepCore Calibration and Data Processing

    Authors: IceCube Collaboration, R. Abbasi, M. Ackermann, J. Adams, S. K. Agarwalla, J. A. Aguilar, M. Ahlers, J. M. Alameddine, N. M. Amin, K. Andeen, G. Anton, C. Argüelles, Y. Ashida, S. Athanasiadou, S. N. Axani, X. Bai, A. Balagopal V., M. Baricevic, S. W. Barwick, V. Basu, R. Bay, J. J. Beatty, K. -H. Becker, J. Becker Tjus, J. Beise , et al. (383 additional authors not shown)

    Abstract: We describe a new data sample of IceCube DeepCore and report on the latest measurement of atmospheric neutrino oscillations obtained with data recorded between 2011-2019. The sample includes significant improvements in data calibration, detector simulation, and data processing, and the analysis benefits from a detailed treatment of systematic uncertainties, with significantly higher level of detai… ▽ More

    Submitted 8 August, 2023; v1 submitted 24 April, 2023; originally announced April 2023.