-
Measurement of the intrinsic hadronic contamination in the NA64$-e$ high-purity $e^+/e^-$ beam at CERN
Authors:
Yu. M. Andreev,
D. Banerjee,
B. Banto Oberhauser,
J. Bernhard,
P. Bisio,
M. Bondi,
A. Celentano,
N. Charitonidis,
A. G. Chumakov,
D. Cooke,
P. Crivelli,
E. Depero,
A. V. Dermenev,
S. V. Donskov,
R. R. Dusaev,
T. Enik,
V. N. Frolov,
A. Gardikiotis,
S. G. Gerassimov,
S. N. Gninenko,
M. H"osgen,
M. Jeckel,
V. A. Kachanov,
Y. Kambar,
A. E. Karneyeu
, et al. (43 additional authors not shown)
Abstract:
In this study, we present the measurement of the intrinsic hadronic contamination at the CERN SPS H4 beamline configured to transport electrons and positrons at 100 GeV/c momentum. The analysis was performed using data collected by the NA64-$e$ experiment in 2022. Our study is based on calorimetric measurements, exploiting the different interaction mechanisms of electrons and hadrons in the NA64-E…
▽ More
In this study, we present the measurement of the intrinsic hadronic contamination at the CERN SPS H4 beamline configured to transport electrons and positrons at 100 GeV/c momentum. The analysis was performed using data collected by the NA64-$e$ experiment in 2022. Our study is based on calorimetric measurements, exploiting the different interaction mechanisms of electrons and hadrons in the NA64-ECAL and NA64-HCAL detectors. We determined the intrinsic hadronic contamination by comparing the results obtained using the nominal electron/positron beamline configuration with those obtained in a dedicated setup, in which only hadrons impinged on the detector. The significant differences in the experimental signatures of electrons and hadrons motivated our approach, resulting in a small and well-controlled systematic uncertainty for the measurement. Our study allowed us to precisely determine the intrinsic hadronic contamination, which represents a crucial parameter for the NA64 experiment in which the hadron contaminants may result in non-trivial backgrounds. Moreover, we performed dedicated Monte Carlo simulations for the hadron production induced by the primary T2 target. We found a good agreement between measurements and simulation results, confirming the validity of the applied methodology and our evaluation of the intrinsic hadronic contamination.
△ Less
Submitted 11 October, 2023; v1 submitted 30 May, 2023;
originally announced May 2023.
-
Letter of Intent: A New QCD facility at the M2 beam line of the CERN SPS (COMPASS++/AMBER)
Authors:
B. Adams,
C. A. Aidala,
R. Akhunzyanov,
G. D. Alexeev,
M. G. Alexeev,
A. Amoroso,
V. Andrieux,
N. V. Anfimov,
V. Anosov,
A. Antoshkin,
K. Augsten,
W. Augustyniak,
C. D. R. Azevedo,
A. Azhibekov,
B. Badelek,
F. Balestra,
M. Ball,
J. Barth,
R. Beck,
Y. Bedfer,
J. Berenguer Antequera,
J. C. Bernauer,
J. Bernhard,
M. Bodlak,
P. Bordalo
, et al. (242 additional authors not shown)
Abstract:
A New QCD facility at the M2 beam line of the CERN SPS
COMPASS++/AMBER
A New QCD facility at the M2 beam line of the CERN SPS
COMPASS++/AMBER
△ Less
Submitted 25 January, 2019; v1 submitted 2 August, 2018;
originally announced August 2018.
-
Performance of Multiplexed XY Resistive Micromegas detectors in a high intensity beam
Authors:
D. Banerjee,
V. Burtsev,
A. Chumakov,
D. Cooke,
E. Depero,
A. V. Dermenev,
S. V. Donskov,
F. Dubinin,
R. R. Dusaev,
S. Emmenegger,
A. Fabich,
V. N. Frolov,
A. Gardikiotis,
S. N. Gninenko,
M. Hösgen,
A. E. Karneyeu,
B. Ketzer,
M. M. Kirsanov,
I. V. Konorov,
V. A. Kramarenko,
S. V. Kuleshov,
E. Levchenko,
V. E. Lyubovitskij,
V. Lysan,
S. Mamon
, et al. (16 additional authors not shown)
Abstract:
We present the performance of multiplexed XY resistive Micromegas detectors tested in the CERN SPS 100 GeV/c electron beam at intensities up to 3.3 $\times$ 10$^5$ e$^- $/(s$\cdot$cm$^2$). So far, all studies with multiplexed Micromegas have only been reported for tests with radioactive sources and cosmic rays. The use of multiplexed modules in high intensity environments was not explored due to t…
▽ More
We present the performance of multiplexed XY resistive Micromegas detectors tested in the CERN SPS 100 GeV/c electron beam at intensities up to 3.3 $\times$ 10$^5$ e$^- $/(s$\cdot$cm$^2$). So far, all studies with multiplexed Micromegas have only been reported for tests with radioactive sources and cosmic rays. The use of multiplexed modules in high intensity environments was not explored due to the effect of ambiguities in the reconstruction of the hit point caused by the multiplexing feature. At the beam intensities analysed in this work and with a multiplexing factor of 5, more than 50% level of ambiguity is introduced. Our results prove that by using the additional information of cluster size and integrated charge from the signal clusters induced on the XY strips, the ambiguities can be reduced to a level below 2%. The tested detectors are used in the CERN NA64 experiment for tracking the incoming particles bending in a magnetic field in order to reconstruct their momentum. The average hit detection efficiency of each module was found to be $\sim$ 96% at the highest beam intensities. By using four modules a tracking resolution of 1.1% was obtained with $\sim$ 85% combined tracking efficiency.
△ Less
Submitted 14 August, 2017;
originally announced August 2017.
-
High purity 100 GeV electron identification with synchrotron radiation
Authors:
E. Depero,
D. Banerjee,
V. Burtsev,
A. Chumakov,
D. Cooke,
A. V. Dermenev,
S. V. Donskov,
F. Dubinin,
R. R. Dusaev,
S. Emmenegger,
A. Fabich,
V. N. Frolov,
A. Gardikiotis,
S. N. Gninenko,
M. Hösgen,
A. E. Karneyeu,
B. Ketzer,
M. M. Kirsanov,
I. V. Konorov,
V. A. Kramarenko,
S. V. Kuleshov,
V. E. Lyubovitskij,
V. Lysan,
V. A. Matveev,
Yu. V. Mikhailov
, et al. (14 additional authors not shown)
Abstract:
In high energy experiments such as active beam dump searches for rare decays and missing energy events, the beam purity is a crucial parameter. In this paper we present a technique to reject heavy charged particle contamination in the 100 GeV electron beam of the H4 beam line at CERN SPS. The method is based on the detection with BGO scintillators of the synchrotron radiation emitted by the electr…
▽ More
In high energy experiments such as active beam dump searches for rare decays and missing energy events, the beam purity is a crucial parameter. In this paper we present a technique to reject heavy charged particle contamination in the 100 GeV electron beam of the H4 beam line at CERN SPS. The method is based on the detection with BGO scintillators of the synchrotron radiation emitted by the electrons passing through a bending dipole magnet. A 100 GeV $π^-$ beam is used to test the method in the NA64 experiment resulting in a suppression factor of $10^{-5}$ while the efficiency for electron detection is $\sim$95%. The spectra and the rejection factors are in very good agreement with the Monte Carlo simulation. The reported suppression factors are significantly better than previously achieved.
△ Less
Submitted 17 March, 2017;
originally announced March 2017.