-
Magnetic field tunable spectral response of kinetic inductance detectors
Authors:
F. Levy-Bertrand,
M. Calvo,
U. Chowdhury,
A. Gomez,
J. Goupy,
A. Monfardini
Abstract:
We tune the onset of optical response in aluminium kinetic inductance detectors from a natural cutoff frequency of 90 GHz to 60 GHz by applying an external magnetic field. The change in spectral response is due to the decrease of the superconducting gap, from 90 GHz at zero magnetic field to 60 GHz at a magnetic field of around 3 mT. We characterize the variation of the superconducting gap, the de…
▽ More
We tune the onset of optical response in aluminium kinetic inductance detectors from a natural cutoff frequency of 90 GHz to 60 GHz by applying an external magnetic field. The change in spectral response is due to the decrease of the superconducting gap, from 90 GHz at zero magnetic field to 60 GHz at a magnetic field of around 3 mT. We characterize the variation of the superconducting gap, the detector frequency shift and the internal quality factor as a function of the applied field. In principle, the magnetic field tunable response could be used to make spectroscopic measurements. In practice, the internal quality factor behaves hysteretically with the magnetic field due to the presence of vortices in the thin superconducting film. We conclude by discussing possible solutions to achieve spectroscopy measurements using kinetic inductance detectors and magnetic field.
△ Less
Submitted 5 September, 2024;
originally announced September 2024.
-
Aluminum nuclear demagnetization refrigerator for powerful continuous cooling
Authors:
Matthias Raba,
Sébastien Triqueneaux,
James Butterworth,
David Schmoranzer,
Emilio Barria,
Jérôme Debray,
Guillaume Donnier-Valentin,
Thibaut Gandit,
Anne Gerardin,
Johannes Goupy,
Olivier Tissot,
Eddy Collin,
Andrew Fefferman
Abstract:
Many laboratories routinely cool samples to 10 mK, but relatively few can cool condensed matter below 1 mK. Easy access to the microkelvin range would propel fields such as quantum sensors and quantum materials. Such temperatures are achieved with adiabatic nuclear demagnetization. Existing nuclear demagnetization refrigerators (NDR) are ``single-shot'', and the recycling time is incompatible with…
▽ More
Many laboratories routinely cool samples to 10 mK, but relatively few can cool condensed matter below 1 mK. Easy access to the microkelvin range would propel fields such as quantum sensors and quantum materials. Such temperatures are achieved with adiabatic nuclear demagnetization. Existing nuclear demagnetization refrigerators (NDR) are ``single-shot'', and the recycling time is incompatible with some sub-mK experiments. Furthermore, a high cooling power is required to overcome the excess heat load of order nW on NDR pre-cooled by cryogen-free dilution refrigerators. We report the performance of an aluminum NDR designed for powerful cooling when part of a dual stage continuous NDR (CNDR). Its thermal resistance is minimized to maximize the cycling rate of the CNDR and consequently its cooling power. At the same time, its susceptibility to eddy current heating is minimized. A CNDR based on two of the aluminum NDR presented here would achieve a cooling power of approximately 40 nW at 560 $μ$K less than six days after cooling from room temperature, with a small offset in electronic temperature that decreases as the time-dependent heat load decays.
△ Less
Submitted 25 July, 2024; v1 submitted 30 April, 2024;
originally announced April 2024.
-
Results from a Prototype TES Detector for the Ricochet Experiment
Authors:
Ricochet Collaboration,
C. Augier,
G. Baulieu,
V. Belov,
L. Bergé,
J. Billard,
G. Bres,
J-. L. Bret,
A. Broniatowski,
M. Calvo,
A. Cazes,
D. Chaize,
M. Chala,
C. L. Chang,
M. Chapellier,
L. Chaplinsky,
G. Chemin,
R. Chen,
J. Colas,
E. Cudmore,
M. De Jesus,
P. de Marcillac,
L. Dumoulin,
O. Exshaw,
S. Ferriol
, et al. (66 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers valuable sensitivity to physics beyond the Standard Model. The Ricochet experiment will use cryogenic solid-state detectors to perform a precision measurement of the CE$ν$NS spectrum induced by the high neutrino flux from the Institut Laue-Langevin nuclear reactor. The experiment will employ an array of detectors, each with a mass of…
▽ More
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers valuable sensitivity to physics beyond the Standard Model. The Ricochet experiment will use cryogenic solid-state detectors to perform a precision measurement of the CE$ν$NS spectrum induced by the high neutrino flux from the Institut Laue-Langevin nuclear reactor. The experiment will employ an array of detectors, each with a mass of $\sim$30 g and a targeted energy threshold of 50 eV. Nine of these detectors (the "Q-Array") will be based on a novel Transition-Edge Sensor (TES) readout style, in which the TES devices are thermally coupled to the absorber using a gold wire bond. We present initial characterization of a Q-Array-style detector using a 1 gram silicon absorber, obtaining a baseline root-mean-square resolution of less than 40 eV.
△ Less
Submitted 12 January, 2024; v1 submitted 28 April, 2023;
originally announced April 2023.
-
A millimetre-wave superconducting hyper-spectral device
Authors:
Usasi Chowdhury,
Florence Levy-Bertrand,
Martino Calvo,
Johannes Goupy,
Alessandro Monfardini
Abstract:
Millimetre-wave observations represent an important tool for Cosmology studies. The Line Intensity Mapping (LIM) technique has been proposed to map in three dimensions the specific intensity due to line (e.g. [CII], CO) emission, for example from the primordial galaxies, as a function of redshift. Hyper-spectral integrated devices have the potential to replace the current Fourier transform, or the…
▽ More
Millimetre-wave observations represent an important tool for Cosmology studies. The Line Intensity Mapping (LIM) technique has been proposed to map in three dimensions the specific intensity due to line (e.g. [CII], CO) emission, for example from the primordial galaxies, as a function of redshift. Hyper-spectral integrated devices have the potential to replace the current Fourier transform, or the planned Fabry-Perot-based instruments operating at millimetre and sub-millimetre wavelengths. The aim is to perform hyper-spectral mapping, with a spectral resolution R= 100-1000, over large, i.e. thousands of beams, instantaneous patches of the Sky. The innovative integrated device that we have developed allows avoiding moving parts, complicated and/or dispersive optics or tunable filters to be operated at cryogenic temperatures. The prototype hyper-spectral focal plane is sensitive in the 75-90GHz range and contains nineteen horns for sixteen spectral-imaging channels, each selecting a frequency band of about 0.1GHz. For each channel a conical horn antenna, coupled to a planar superconducting resonant absorber made of thin aluminium, collects the radiation. A capacitively coupled titanium-aluminium bilayer Lumped Element Kinetic Inductance Detector (LEKID) is then in charge of dissipating and sensing the super-current established in the resonant absorber. The prototype is fabricated with only two photo-lithography steps over a commercial mono-crystalline sapphire substrate. It exhibits a spectral resolution of about 800. The optical noise equivalent power of the best channels is in the observational relevant 4E-17W/sqrt(Hz) range. The average sensitivity of all the channels is around 1E-16W/sqrt(Hz). The device, as expected from 3-D simulations, is polarisation-sensitive, paving the way to spectro-polarimetry measurements over very large instantaneous field-of-views.
△ Less
Submitted 27 August, 2023; v1 submitted 9 November, 2022;
originally announced November 2022.
-
BULLKID: Monolithic array of particle absorbers sensed by Kinetic Inductance Detectors
Authors:
A. Cruciani,
L. Bandiera,
M. Calvo,
N. Casali,
I. Colantoni,
G. Del Castello,
M. del Gallo Roccagiovine,
D. Delicato,
M. Giammei,
V. Guidi,
J. Goupy,
V. Pettinacci,
G. Pettinari,
M. Romagnoni,
M. Tamisari,
A. Mazzolari,
A. Monfardini,
M. Vignati
Abstract:
We introduce BULLKID, an innovative phonon detector consisting of an array of dices acting as particle absorbers sensed by multiplexed Kinetic Inductance Detectors (KIDs). The dices are carved in a thick crystalline wafer and form a monolithic structure. The carvings leave a thin common disk intact in the wafer, acting both as holder for the dices and as substrate for the KID lithography. The prot…
▽ More
We introduce BULLKID, an innovative phonon detector consisting of an array of dices acting as particle absorbers sensed by multiplexed Kinetic Inductance Detectors (KIDs). The dices are carved in a thick crystalline wafer and form a monolithic structure. The carvings leave a thin common disk intact in the wafer, acting both as holder for the dices and as substrate for the KID lithography. The prototype presented consists of an array of 64 dices of 5.4x5.4x5 mm$^3$ carved in a 3" diameter, 5 mm thick silicon wafer, with a common disk 0.5 mm thick hosting a 60 nm patterned aluminum layer. The resulting array is highly segmented but avoids the use of dedicated holding structures for each unit. Despite the fact that the uniformity of the KID electrical response across the array needs optimization, the operation of 8 units with similar features shows, on average, a baseline energy resolution of $26\pm7$ eV. This makes it a suitable detector for low-energy processes such as direct interactions of dark matter and coherent elastic neutrino-nucleus scattering.
△ Less
Submitted 29 September, 2022;
originally announced September 2022.
-
A horn-coupled millimeter-wave on-chip spectrometer based on Lumped Element Kinetic Inductance Detectors
Authors:
Usasi Chowdhury,
Florence Levy-Bertrand,
Martino Calvo,
Johannes Goupy,
Alessandro Monfardini
Abstract:
Context. Millimetre-wave astronomy is an important tool for both general astrophysics studies and cosmology. A large number of unidentified sources are being detected by the large field-of-view continuum instruments operating on large telescopes.
Aims. New smart focal planes are needed to bridge the gap between large bandwidth continuum instruments operating on single dish telescopes and the hig…
▽ More
Context. Millimetre-wave astronomy is an important tool for both general astrophysics studies and cosmology. A large number of unidentified sources are being detected by the large field-of-view continuum instruments operating on large telescopes.
Aims. New smart focal planes are needed to bridge the gap between large bandwidth continuum instruments operating on single dish telescopes and the high spectral and angular resolution interferometers (e.g. ALMA in Chile, NOEMA in France). The aim is to perform low-medium spectral resolution observations and select a lower number of potentially interesting sources, i.e. high-redshift galaxies, for further follow-up.
Methods. We have designed, fabricated and tested an innovative on-chip spectrometer sensitive in the 85-110~GHz range. It contains sixteen channels selecting a frequency band of about 0.2 GHz each. A conical horn antenna coupled to a slot in the ground plane collects the radiation and guides it to a mm-wave microstrip transmission line placed on the other side of the mono-crystalline substrate. The mm-wave line is coupled to a filter-bank. Each filter is capacitively coupled to a Lumped Element Kinetic Inductance Detector (LEKID). The microstrip configuration allows to benefit from the high quality, i.e. low losses, mono-crystalline substrate, and at the same time prevents direct, i.e. un-filtered, LEKID illumination.
Results. The prototype spectrometer exhibit a spectral resolution R = lambda / Delta_lambda = 300. The optical noise equivalent power is in the low 1E-16W/sqrt(Hz) range for an incoming power of about 0.2pW per channel. The device is polarisation-sensitive, with a cross-polarisation lower than 1% for the best channels.
△ Less
Submitted 6 September, 2022;
originally announced September 2022.
-
CONCERTO: Readout and control electronics
Authors:
O. Bourrion,
C. Hoarau,
J. Bounmy,
D. Tourres,
C. Vescovi J. -L. Bouly,
N. Ponchant,
A. Beelen,
M. Calvo,
A. Catalano,
J. Goupy,
G. Lagache,
J. -F. Macías-Pérez,
J. Marpaud,
A. Monfardini
Abstract:
The CONCERTO spectral-imaging instrument was installed at the Atacama Pathfinder EXperiment (APEX) 12-meter telescope in April 2021. It has been designed to look at radiation emitted by ionised carbon atoms, [CII], and use the "intensity Mapping" technique to set the first constraints on the power spectrum of dusty star-forming galaxies. The instrument features two arrays of 2152 pixels constitute…
▽ More
The CONCERTO spectral-imaging instrument was installed at the Atacama Pathfinder EXperiment (APEX) 12-meter telescope in April 2021. It has been designed to look at radiation emitted by ionised carbon atoms, [CII], and use the "intensity Mapping" technique to set the first constraints on the power spectrum of dusty star-forming galaxies. The instrument features two arrays of 2152 pixels constituted of Lumped Element Kinectic Inductance Detectors (LEKID) operated at cryogenic temperatures, cold optics and a fast Fourier Transform Spectrometer (FTS). To readout and operate the instrument, a newly designed electronic system hosted in five microTCA crates and composed of twelve readout boards and two control boards was designed and commissioned. The architecture and the performances are presented in this paper.
△ Less
Submitted 21 October, 2022; v1 submitted 16 August, 2022;
originally announced August 2022.
-
Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor
Authors:
C. Augier,
G. Baulieu,
V. Belov,
L. Berge,
J. Billard,
G. Bres,
J. -L. Bret,
A. Broniatowski,
M. Calvo,
A. Cazes,
D. Chaize,
M. Chapellier,
L. Chaplinsky,
G. Chemin,
R. Chen,
J. Colas,
M. De Jesus,
P. de Marcillac,
L. Dumoulin,
O. Exshaw,
S. Ferriol,
E. Figueroa-Feliciano,
J. -B. Filippini,
J. A. Formaggio,
S. Fuard
, et al. (58 additional authors not shown)
Abstract:
The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 meters away from the 58 MW resear…
▽ More
The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 meters away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment's shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $^3$He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance.
△ Less
Submitted 2 August, 2022;
originally announced August 2022.
-
CONCERTO : Digital processing for finding and tuning LEKIDs
Authors:
Julien Bounmy,
Christophe Hoarau,
Juan-Francisco Macías-Pérez,
Alexandre Beelen,
Alain Benoît,
Olivier Bourrion,
Martino Calvo,
Andrea Catalano,
Alessandro Fasano,
Johannes Goupy,
Guilaine Lagache,
Julien Marpaud,
Alessandro Monfardini
Abstract:
We describe the on-line algorithms developed to probe Lumped Element Kinetic Inductance Detectors (LEKID) in this paper. LEKIDs are millimeter wavelength detectors for astronomy. LEKID arrays are currently operated in different instruments as: NIKA2 at the IRAM telescope in Spain, KISS at the Teide Observatory telescope in Tenerife, and CONCERTO at the APEX 12-meter telescope in Chile. LEKIDs are…
▽ More
We describe the on-line algorithms developed to probe Lumped Element Kinetic Inductance Detectors (LEKID) in this paper. LEKIDs are millimeter wavelength detectors for astronomy. LEKID arrays are currently operated in different instruments as: NIKA2 at the IRAM telescope in Spain, KISS at the Teide Observatory telescope in Tenerife, and CONCERTO at the APEX 12-meter telescope in Chile. LEKIDs are superconducting microwave resonators able to detect the incoming light at millimeter wavelengths and they are well adapted for frequency multiplexing (currently up to 360 pixels on a single microwave guide). Nevertheless, their use for astronomical observations requires specific readout and acquisition systems both to deal with the instrumental and multiplexing complexity, and to adapt to the observational requirements (e.g. fast sampling rate, background variations, on-line calibration, photometric accuracy, etc). This paper presents the different steps of treatment from identifying the resonance frequency of each LEKID to the continuous automatic control of drifting LEKID resonance frequencies induced by background variations.
△ Less
Submitted 7 September, 2022; v1 submitted 23 June, 2022;
originally announced June 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
Improvement of contact-less KID design using multilayered Al/Ti material for resonator
Authors:
J. Colas,
M. Calvo,
J. Goupy,
A. Monfardini,
M. De Jesus,
J. Billard,
A. Juillard,
L. Vagneron
Abstract:
The necessity to increase exposure in rare event searches experiments by maintaining a low energy threshold and a good energy resolution leads to segmented detectors as in EDELWEISS (Dark Matter), CUORE (0ν\b{eta}\b{eta}) or RICOCHET (CEνNS) for example. However, the large number of sub-elements can dramatically increase the complexity of such detector arrays. In this work we report on our progres…
▽ More
The necessity to increase exposure in rare event searches experiments by maintaining a low energy threshold and a good energy resolution leads to segmented detectors as in EDELWEISS (Dark Matter), CUORE (0ν\b{eta}\b{eta}) or RICOCHET (CEνNS) for example. However, the large number of sub-elements can dramatically increase the complexity of such detector arrays. In this work we report on our progress towards designing a flexible detector technology based on KID resonators evaporated on massive target crystals readout by a contact-less feed-line. Providing that we achieve O(100) eV energy threshold, such approach could easily be scaled to tens of kilogram detector arrays thanks to the intrinsic multiplexing capability of mKIDs. Using a 30 g silicon target absorber with Al/Ti multilayers for the KID resonator, we report a significant improvement of our detector response exhibiting a keV-scale energy resolution combined with the absence of position dependence on the event location. Indeed, compared to our previous work, we are now able to properly identify calibration lines from surface (20 keV X-rays) and bulk events (60 keV gamma rays). This significant improvement is an important step toward a better understanding of phonons and quasiparticles dynamics which is pivotal in optimizing this technology.
△ Less
Submitted 24 November, 2021;
originally announced November 2021.
-
Superconducting aluminum heat switch with 3 n$Ω$ equivalent resistance
Authors:
James Butterworth,
Sébastien Triqueneaux,
Šimon Midlik,
Ilya Golokolenov,
Anne Gerardin,
Thibaut Gandit,
Guillaume Donnier-Valentin,
Johannes Goupy,
M. Keith Phuthi,
David Schmoranzer,
Eddy Collin,
Andrew Fefferman
Abstract:
Superconducting heat switches with extremely low normal state resistances are needed for constructing continuous nuclear demagnetization refrigerators with high cooling power. Aluminum is a suitable superconductor for the heat switch because of its high Debye temperature and its commercial availability in high purity. We have constructed a high quality Al heat switch whose design is significantly…
▽ More
Superconducting heat switches with extremely low normal state resistances are needed for constructing continuous nuclear demagnetization refrigerators with high cooling power. Aluminum is a suitable superconductor for the heat switch because of its high Debye temperature and its commercial availability in high purity. We have constructed a high quality Al heat switch whose design is significantly different than that of previous heat switches. In order to join the Al to Cu with low contact resistance, we plasma etched the Al to remove its oxide layer then immediately deposited Au without breaking the vacuum of the e-beam evaporator. In the normal state of the heat switch, we measured a thermal conductance of $8 T$ W/K$^2$ which is equivalent to an electrical resistance of 3 n$Ω$ according to the Wiedemann-Franz law. In the superconducting state we measured a thermal conductance that is $2\times10^6$ times lower than that of the normal state at 50 mK.
△ Less
Submitted 23 April, 2022; v1 submitted 23 November, 2021;
originally announced November 2021.
-
Ricochet Progress and Status
Authors:
Ricochet Collaboration,
G. Beaulieu,
V. Belov,
L. Berge,
J. Billard,
G. Bres,
J-. L. Bret,
A. Broniatowski,
M. Calvo,
A. Cazes,
D. Chaize,
M. Chapellier,
L. Chaplinsky,
G. Chemin,
R. Chen,
J. Colas,
M. De Jesus,
P. de Marcillac,
L. Dumoulin,
O. Exshaw,
S. Ferriol,
E. Figueroa-Feliciano,
J. B. Filippini,
J. A. Formaggio,
S. Fuard
, et al. (55 additional authors not shown)
Abstract:
We present an overview of recent progress towards the Ricochet coherent elastic neutrino nucleus scattering CE$ν$NS experiment. The ILL research reactor in Grenoble, France has been selected as the experiment site, after in situ studies of vibration and particle backgrounds. We present background rate estimates specific to that site, along with descriptions of the planned CryoCube and Q-Array dete…
▽ More
We present an overview of recent progress towards the Ricochet coherent elastic neutrino nucleus scattering CE$ν$NS experiment. The ILL research reactor in Grenoble, France has been selected as the experiment site, after in situ studies of vibration and particle backgrounds. We present background rate estimates specific to that site, along with descriptions of the planned CryoCube and Q-Array detector payloads.
△ Less
Submitted 12 November, 2021;
originally announced November 2021.
-
CONCERTO at APEX: installation and technical commissioning
Authors:
A. Monfardini,
A. Beelen,
A. Benoit,
J. Bounmy,
M. Calvo,
A. Catalano,
J. Goupy,
G. Lagache,
P. Ade,
E. Barria,
M. Bethermin,
O. Bourrion,
G. Bres,
C. De Breuck,
F. -X. Desert,
G. Duvauchelle,
A. Fasano,
T. Fenouillet,
J. Garcia,
G. Garde,
C. Hoarau,
W. Hu,
J. -C. Lambert,
F. Levy-Bertrand,
A. Lundgren
, et al. (19 additional authors not shown)
Abstract:
We describe the deployment and first tests on Sky of CONCERTO, a large field-of-view (18.6arc-min) spectral-imaging instrument. The instrument operates in the range 130-310GHz from the APEX 12-meters telescope located at 5100m a.s.l. on the Chajnantor plateau. Spectra with R=1-300 are obtained using a fast (2.5Hz mechanical frequency) Fourier Transform Spectrometer (FTS), coupled to a continuous d…
▽ More
We describe the deployment and first tests on Sky of CONCERTO, a large field-of-view (18.6arc-min) spectral-imaging instrument. The instrument operates in the range 130-310GHz from the APEX 12-meters telescope located at 5100m a.s.l. on the Chajnantor plateau. Spectra with R=1-300 are obtained using a fast (2.5Hz mechanical frequency) Fourier Transform Spectrometer (FTS), coupled to a continuous dilution cryostat with a base temperature of 60mK. Two 2152-pixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) are installed in the cryostat that also contains the cold optics and the front-end electronics. CONCERTO, installed in April 2021, generates more than 20k spectra per second during observations. We describe the final development phases, the installation and the first results obtained on Sky.
△ Less
Submitted 26 June, 2021;
originally announced June 2021.
-
Understanding and minimizing resonance frequency deviations on a 4-inch kilo-pixel kinetic inductance detector array
Authors:
S. Shu,
M. Calvo,
J. Goupy,
S. Leclercq,
A. Catalano,
A. Bideaud,
A. Monfardini,
E. F. C. Driessen
Abstract:
One of the advantages of kinetic inductance detectors is their intrinsic frequency domain multiplexing capability. However, fabrication imperfections usually give rise to resonance frequency deviations, which create frequency collision and limit the array yield. Here we study the resonance frequency deviation of a 4-inch kilo-pixel lumped-element kinetic inductance detector (LEKID) array using opt…
▽ More
One of the advantages of kinetic inductance detectors is their intrinsic frequency domain multiplexing capability. However, fabrication imperfections usually give rise to resonance frequency deviations, which create frequency collision and limit the array yield. Here we study the resonance frequency deviation of a 4-inch kilo-pixel lumped-element kinetic inductance detector (LEKID) array using optical mapping. Using the measured resonator dimensions and film thickness, the fractional deviation can be explained within $\pm 25\times 10^{-3}$, whereas the residual deviation is due to variation of electric film properties. Using the capacitor trimming technique, the fractional deviation is decreased by a factor of 14. The yield of the trimming process is found to be 97%. The mapping yield, measured under a 110~K background, is improved from 69% to 76%, which can be further improved to 81% after updating our readout system. With the improvement in yield, the capacitor trimming technique may benefit future large-format LEKID arrays.
△ Less
Submitted 30 August, 2021; v1 submitted 28 May, 2021;
originally announced May 2021.
-
Subgap kinetic inductance detector sensitive to 85-GHz radiation
Authors:
F. Levy-Bertrand,
A. Benoît,
O. Bourrion,
M. Calvo,
A. Catalano,
J. Goupy,
F. Valenti,
N. Maleeva,
L. Grünhaupt,
I. M. Pop,
A. Monfardini
Abstract:
We have fabricated an array of subgap kinetic inductance detectors (SKIDs) made of granular aluminum ($T_c\sim$2~K) sensitive in the 80-90 GHz frequency band and operating at 300~mK. We measure a noise equivalent power of $1.3\times10^{-16}$~W/Hz$^{0.5}$ on average and $2.6\times10^{-17}$~W/Hz$^{0.5}$ at best, for an illuminating power of 50~fW per pixel. Even though the circuit design of SKIDs is…
▽ More
We have fabricated an array of subgap kinetic inductance detectors (SKIDs) made of granular aluminum ($T_c\sim$2~K) sensitive in the 80-90 GHz frequency band and operating at 300~mK. We measure a noise equivalent power of $1.3\times10^{-16}$~W/Hz$^{0.5}$ on average and $2.6\times10^{-17}$~W/Hz$^{0.5}$ at best, for an illuminating power of 50~fW per pixel. Even though the circuit design of SKIDs is identical to that of the kinetic inductance detectors (KIDs), the SKIDs operating principle is based on their sensitivity to subgap excitations. This detection scheme is advantageous because it avoids having to lower the operating temperature proportionally to the lowest detectable frequency. The SKIDs presented here are intrinsically selecting the 80-90 GHz frequency band, well below the superconducting spectral gap of the film, at approximately 180 GHz.
△ Less
Submitted 6 April, 2021; v1 submitted 8 October, 2020;
originally announced October 2020.
-
Very low resistance Al/Cu joints for use at cryogenic temperatures
Authors:
Sébastien Triqueneaux,
James Butterworth,
Johannes Goupy,
Clément Ribas,
David Schmoranzer,
Eddy Collin,
Andrew Fefferman
Abstract:
We present two different techniques for achieving low resistance ($<$20 n$\rm Ω$) contacts between copper and aluminium at cryogenic temperatures. The best method is based on gold plating of the surfaces in an e-beam evaporator immediately after Ar plasma etching in the same apparatus, yielding resistances as low as 3 n$\rm Ω$ that are stable over time. The second approach involves inserting indiu…
▽ More
We present two different techniques for achieving low resistance ($<$20 n$\rm Ω$) contacts between copper and aluminium at cryogenic temperatures. The best method is based on gold plating of the surfaces in an e-beam evaporator immediately after Ar plasma etching in the same apparatus, yielding resistances as low as 3 n$\rm Ω$ that are stable over time. The second approach involves inserting indium in the Al/Cu joint. For both methods, we believe key elements are surface polishing, total removal of the aluminum oxide surface layer, and temporary application of large (typ. 11 kN) compression forces. We believe the values for gold plated contacts are the lowest ever reported for a Cu/Al joint of a few $\rm cm^{2}$. This technology could simplify the construction of thermal links for advanced cryogenics applications, in particular that of extremely low resistance heat switches for nuclear demagnetization refrigerators.
△ Less
Submitted 31 March, 2021; v1 submitted 4 September, 2020;
originally announced September 2020.
-
Development and application of metamaterial-based Half-Wave Plates for the NIKA and NIKA2 polarimeters
Authors:
G. Pisano,
A. Ritacco,
A. Monfardini,
C. Tucker,
P. A. R. Ade,
A. Shitvov,
A. Benoit,
M. Calvo,
A. Catalano,
J. Goupy,
S. Leclercq,
J. Macias-Perez,
A. Andrianasolo,
N. Ponthieu
Abstract:
CONTEXT.Large field-of-view imaging/polarimetry instruments operating at millimeter and submm wavelengths are fundamental tools to understand the role of magnetic fields (MF) in channeling filament material into prestellar cores providing a unique insight in the physics of galactic star-forming regions. Among other topics, at extra-galactic scales, polarization observations of AGNs will allow us t…
▽ More
CONTEXT.Large field-of-view imaging/polarimetry instruments operating at millimeter and submm wavelengths are fundamental tools to understand the role of magnetic fields (MF) in channeling filament material into prestellar cores providing a unique insight in the physics of galactic star-forming regions. Among other topics, at extra-galactic scales, polarization observations of AGNs will allow us to constrain the possible physical conditions of the emitting plasma from the jets and/or exploring the physics of dust inside supernova remnants. The kilo-pixel NIKA2 camera, installed at the IRAM 30-m telescope, represents today one of the best tools available to the astronomers to produce simultaneous intensity/polarimetry maps over large fields at 260 GHz (1.15 mm). AIMS.The polarization measurement, in NIKA and NIKA2, is achieved by rapidly modulating the total incoming polarization. This allows in the end to safely isolate the small science signal from the large, un-polarized and strongly variable, atmospheric background. METHODS.The polarization modulation is achieved by inserting a fast rotating Half-Wave Plate (HWP) in the optical beam. In order to allow wide field-of-view observations, the plate has to be large, with a diameter exceeding 250 mm. The modulation of the polarized signal, at 12 Hz, requires also the waveplate to be sufficiently light. In addition, this key optical element has to exhibit optimal electromagnetic characteristics in terms of transmission and differential phase-shift. For this purpose, three metamaterial HWPs have been developed using the mesh-filter technology. The knowledge acquired in developing the first two single-band HWPs was used to achieve the more challenging performance requirements of the last dual-band HWP. The first and the third waveplates met the requirements for both the NIKA and NIKA2 instruments. RESULTS.(abridged)
△ Less
Submitted 22 June, 2020;
originally announced June 2020.
-
Observing with NIKA2Pol from the IRAM 30m telescope. Early results on the commissioning phase
Authors:
A. Ritacco,
R. Adam,
P. Ade,
H. Ajeddig,
P. André,
A. Andrianasolo,
H. Aussel,
A. Beelen,
A. Benoît,
A. Bideaud,
O. Bourrion,
M. Calvo,
A. Catalano,
B. Comis,
M. De Petris,
F. -X. Désert,
S. Doyle,
E. F. C. Driessen,
A. Gomez,
J. Goupy,
F. Kéruzoré,
C. Kramer,
B. Ladjelate,
G. Lagache,
S. Leclercq
, et al. (19 additional authors not shown)
Abstract:
The NIKA2 polarization channel at 260 GHz (1.15 mm) has been proposed primarily to observe galactic star-forming regions and probe the critical scales between 0.01-0.05 pc at which magnetic field lines may channel the matter of interstellar filaments into growing dense cores. The NIKA2 polarimeter consists of a room temperature continuously rotating multi-mesh HWP and a cold polarizer that separat…
▽ More
The NIKA2 polarization channel at 260 GHz (1.15 mm) has been proposed primarily to observe galactic star-forming regions and probe the critical scales between 0.01-0.05 pc at which magnetic field lines may channel the matter of interstellar filaments into growing dense cores. The NIKA2 polarimeter consists of a room temperature continuously rotating multi-mesh HWP and a cold polarizer that separates the two orthogonal polarizations onto two 260 GHz KIDs arrays. We describe in this paper the preliminary results obtained during the most recent commissioning campaign performed in December 2018. We concentrate here on the analysis of the extended sources, while the observation of compact sources is presented in a companion paper [12]. We present preliminary NIKA2 polarization maps of the Crab nebula. We find that the integrated polarization intensity flux measured by NIKA2 is consistent with expectations.In terms of polarization angle, we are still limited by systematic uncertainties that will be further investigated in the forthcoming commissioning campaigns.
△ Less
Submitted 17 December, 2019;
originally announced December 2019.
-
Calibration and Performance of the NIKA2 camera at the IRAM 30-meter Telescope
Authors:
L. Perotto,
N. Ponthieu,
J. -F. Macías-Pérez,
R. Adam,
P. Ade,
P. André,
A. Andrianasolo,
H. Aussel,
A. Beelen,
A. Benoît,
S. Berta,
A. Bideaud,
O. Bourrion,
M. Calvo,
A. Catalano,
B. Comis,
M. De Petris,
F. -X. Désert,
S. Doyle,
E. F. C. Driessen,
P. García,
A. Gomez,
J. Goupy,
D. John,
F. Kéruzoré
, et al. (23 additional authors not shown)
Abstract:
NIKA2 is a dual-band millimetric continuum camera of 2900 Kinetic Inductance Detectors (KID), operating at $150$ and $260\,\rm{GHz}$, installed at the IRAM 30-meter telescope. We present the performance assessment of NIKA2 after one year of observation using a dedicated point-source calibration method, referred to as the \emph{baseline} method. Using a large data set acquired between January 2017…
▽ More
NIKA2 is a dual-band millimetric continuum camera of 2900 Kinetic Inductance Detectors (KID), operating at $150$ and $260\,\rm{GHz}$, installed at the IRAM 30-meter telescope. We present the performance assessment of NIKA2 after one year of observation using a dedicated point-source calibration method, referred to as the \emph{baseline} method. Using a large data set acquired between January 2017 and February 2018 that span the whole range of observing elevations and atmospheric conditions encountered at the IRAM 30-m telescope, we test the stability of the performance parameters. We report an instantaneous field of view (FOV) of 6.5' in diameter, filled with an average fraction of $84\%$ and $90\%$ of valid detectors at $150$ and $260\,\rm{GHz}$, respectively. The beam pattern is characterized by a FWHM of $17.6'' \pm 0.1''$ and $11.1''\pm 0.2''$, and a beam efficiency of $77\% \pm 2\%$ and $55\% \pm 3\%$ at $150$ and $260\,\rm{GHz}$, respectively. The rms calibration uncertainties are about $3\%$ at $150\,\rm{GHz}$ and $6\%$ at $260\,\rm{GHz}$. The absolute calibration uncertainties are of $5\%$ and the systematic calibration uncertainties evaluated at the IRAM 30-m reference Winter observing conditions are below $1\%$ in both channels. The noise equivalent flux density (NEFD) at $150$ and $260\,\rm{GHz}$ are of $9 \pm 1\, \rm{mJy}\cdot s^{1/2}$ and $30 \pm 3\, \rm{mJy}\cdot s^{1/2}$. This state-of-the-art performance confers NIKA2 with mapping speeds of $1388 \pm 174$ and $111 \pm 11 \,\rm{arcmin}^2\cdot \rm{mJy}^{-2}\cdot \rm{h}^{-1}$ at $150$ and $260\,\rm{GHz}$. With these unique capabilities of fast dual-band mapping at high (better that 18'') angular resolution, NIKA2 is providing an unprecedented view of the millimetre Universe.
△ Less
Submitted 21 January, 2020; v1 submitted 4 October, 2019;
originally announced October 2019.
-
Contact-less phonon detection with massive cryogenic absorbers
Authors:
Johannes Goupy,
Jules Colas,
Martino Calvo,
Julien Billard,
Philippe Camus,
Richard Germond,
Alexandre Juillard,
Lionel Vagneron,
Maryvonne De Jesus,
Florence Levy-Bertrand,
Alessandro Monfardini
Abstract:
We have developed a contact-less technique for the real time measurement of a-thermal (Cooper-pair breaking) phonons in an absorber held at sub-Kelvin temperatures. In particular, a thin-film aluminum superconducting resonator was realized on a 30-grams high-resistivity silicon crystal. The lumped-element resonator is inductively excited/read-out by a radio-frequency microstrip feed-line deposited…
▽ More
We have developed a contact-less technique for the real time measurement of a-thermal (Cooper-pair breaking) phonons in an absorber held at sub-Kelvin temperatures. In particular, a thin-film aluminum superconducting resonator was realized on a 30-grams high-resistivity silicon crystal. The lumped-element resonator is inductively excited/read-out by a radio-frequency microstrip feed-line deposited on another wafer; the sensor, a Kinetic Inductance Detector (KID), is read-out without any physical contact or wiring to the absorber. The resonator demonstrates excellent electrical properties, particularly in terms of its internal quality factor. The detection of alphas and gammas in the massive absorber is achieved, with an RMS energy resolution of about 1.4 keV, which is already interesting for particle physics applications. The resolution of this prototype detector is mainly limited by the low (about 0.3%) conversion efficiency of deposited energy to superconducting excitations (quasi-particles). The demonstrated technique can be further optimized, and used to produce large arrays of a-thermal phonon detectors, for use in rare events searches such as: dark matter direct detection,neutrino-less double beta decay, or coherent elastic neutrino-nucleus scattering.
△ Less
Submitted 19 November, 2019; v1 submitted 25 June, 2019;
originally announced June 2019.
-
Increased multiplexing of superconducting microresonator arrays by post-characterization adaptation of the on-chip capacitors
Authors:
Shibo Shu,
Martino Calvo,
Johannes Goupy,
Samuel Leclercq,
Andrea Catalano,
Aurelien Bideaud,
Alessandro Monfardini,
Eduard F. C. Driessen
Abstract:
We present an interdigitated capacitor trimming technique for fine-tuning the resonance frequency of superconducting microresonators and increasing the multiplexing factor. We first measure the optical response of the array with a beam mapping system to link all resonances to their physical resonators. Then a new set of resonance frequencies with uniform spacing and higher multiplexing factor is d…
▽ More
We present an interdigitated capacitor trimming technique for fine-tuning the resonance frequency of superconducting microresonators and increasing the multiplexing factor. We first measure the optical response of the array with a beam mapping system to link all resonances to their physical resonators. Then a new set of resonance frequencies with uniform spacing and higher multiplexing factor is designed. We use simulations to deduce the lengths that we should trim from the capacitor fingers in order to shift the resonances to the desired frequencies. The sample is then modified using contact lithography and re-measured using the same setup. We demonstrate this technique on a 112-pixel aluminum lumped-element kinetic-inductance detector array. Before trimming, the resonance frequency deviation of this array is investigated. The variation of the inductor width plays the main role for the deviation. After trimming, the mean fractional frequency error for identified resonators is -6.4e-4, with a standard deviation of 1.8e-4. The final optical yield is increased from 70.5% to 96.7% with no observable crosstalk beyond -15 dB during mapping. This technique could be applied to other photon-sensitive superconducting microresonator arrays for increasing the yield and multiplexing factor.
△ Less
Submitted 13 August, 2018; v1 submitted 11 August, 2018;
originally announced August 2018.
-
Tunable sub-gap radiation detection with superconducting resonators
Authors:
O. Dupré,
A. Benoît M. Calvo,
A. Catalano,
J. Goupy,
C. Hoarau,
T. Klein,
K. Le Calvez,
B. Sacépé,
A. Monfardini,
F. Levy-Bertrand
Abstract:
We have fabricated planar amorphous Indium Oxide superconducting resonators ($T_c\sim2.8$ K) that are sensitive to frequency-selective radiation in the range of 7 to 10 GHz. Those values lay far below twice the superconducting gap that worths about 200 GHz. The photons detection consists in a shift of the fundamental resonance frequency. We show that the detected frequency can be adjusted by modul…
▽ More
We have fabricated planar amorphous Indium Oxide superconducting resonators ($T_c\sim2.8$ K) that are sensitive to frequency-selective radiation in the range of 7 to 10 GHz. Those values lay far below twice the superconducting gap that worths about 200 GHz. The photons detection consists in a shift of the fundamental resonance frequency. We show that the detected frequency can be adjusted by modulating the total length of the superconducting resonator. We attribute those observations to the excitation of higher-order resonance modes. The coupling between the fundamental lumped and the higher order distributed resonance is due to the kinetic inductance non-linearity with current. These devices, that we have called Sub-gap Kinetic Inductance Detectors (SKIDs), are to be distinguished from the standard Kinetic Inductance Detectors (KIDs) in which quasi-particles are generated when incident light breaks down Cooper pairs.
△ Less
Submitted 28 February, 2018;
originally announced February 2018.
-
Al/Ti/Al phonon-mediated KIDs for UV-VIS light detection over large areas
Authors:
L. Cardani,
N. Casali,
A. Cruciani,
H. le Sueur,
M. Martinez,
F. Bellini,
M. Calvo,
M. G. Castellano,
I. Colantoni,
C. Cosmelli,
A. D'Addabbo,
S. Di Domizio,
J. Goupy,
L. Minutolo,
A. Monfardini,
M. Vignati
Abstract:
The development of wide-area cryogenic light detectors with baseline energy resolution lower than 20 eV RMS is essential for next generation bolometric experiments searching for rare interactions. Indeed the simultaneous readout of the light and heat signals will enable background suppression through particle identification. Because of their excellent intrinsic energy resolution, as well as their…
▽ More
The development of wide-area cryogenic light detectors with baseline energy resolution lower than 20 eV RMS is essential for next generation bolometric experiments searching for rare interactions. Indeed the simultaneous readout of the light and heat signals will enable background suppression through particle identification. Because of their excellent intrinsic energy resolution, as well as their well-established reproducibility, Kinetic Inductance Detectors (KIDs) are good candidates for the development of next generation light detectors. The CALDER project is investigating the potential of phonon-mediated KIDs. The first phase of the project allowed to reach a baseline resolution of 80 eV using a single KID made of aluminium on a 2x2 cm\tmrsup{$2$} silicon substrate acting as photon absorber. In this paper we present a new prototype detector implementing a trilayer aluminium-titanium-aluminium KID. Taking advantage of the superconducting proximity effect the baseline resolution improves down to 26 eV.
△ Less
Submitted 27 April, 2018; v1 submitted 25 January, 2018;
originally announced January 2018.
-
Exploring Cosmic Origins with CORE: The Instrument
Authors:
P. de Bernardis,
P. A. R. Ade,
J. J. A. Baselmans,
E. S. Battistelli,
A. Benoit,
M. Bersanelli,
A. Bideaud,
M. Calvo,
F. J. Casas,
G. Castellano,
A. Catalano,
I. Charles,
I. Colantoni,
F. Columbro,
A. Coppolecchia,
M. Crook,
G. D'Alessandro,
M. De Petris,
J. Delabrouille,
S. Doyle,
C. Franceschet,
A. Gomez,
J. Goupy,
S. Hanany,
M. Hills
, et al. (104 additional authors not shown)
Abstract:
We describe a space-borne, multi-band, multi-beam polarimeter aiming at a precise and accurate measurement of the polarization of the Cosmic Microwave Background. The instrument is optimized to be compatible with the strict budget requirements of a medium-size space mission within the Cosmic Vision Programme of the European Space Agency. The instrument has no moving parts, and uses arrays of diffr…
▽ More
We describe a space-borne, multi-band, multi-beam polarimeter aiming at a precise and accurate measurement of the polarization of the Cosmic Microwave Background. The instrument is optimized to be compatible with the strict budget requirements of a medium-size space mission within the Cosmic Vision Programme of the European Space Agency. The instrument has no moving parts, and uses arrays of diffraction-limited Kinetic Inductance Detectors to cover the frequency range from 60 GHz to 600 GHz in 19 wide bands, in the focal plane of a 1.2 m aperture telescope cooled at 40 K, allowing for an accurate extraction of the CMB signal from polarized foreground emission. The projected CMB polarization survey sensitivity of this instrument, after foregrounds removal, is 1.7 μK$\cdot$arcmin. The design is robust enough to allow, if needed, a downscoped version of the instrument covering the 100 GHz to 600 GHz range with a 0.8 m aperture telescope cooled at 85 K, with a projected CMB polarization survey sensitivity of 3.2 μK$\cdot$arcmin.
△ Less
Submitted 22 May, 2017; v1 submitted 5 May, 2017;
originally announced May 2017.
-
Polarimetry at millimeter wavelengths with the NIKA camera: calibration and performance
Authors:
A. Ritacco,
N. Ponthieu,
A. Catalano,
R. Adam,
P. Ade,
P. André,
A. Beelen,
A. Benoît,
A. Bideaud,
N. Billot,
O. Bourrion,
M. Calvo,
G. Coiffard,
B. Comis,
F. -X. Désert,
S. Doyle,
J. Goupy,
C. Kramer,
S. Leclercq,
J. F. Macías-Pérez,
P. Mauskopf,
A. Maury,
F. Mayet,
A. Monfardini,
F. Pajot
, et al. (15 additional authors not shown)
Abstract:
Magnetic fields, which play a major role in a large number of astrophysical processes from galactic to cosmological scales, can be traced via observations of dust polarization as demonstrated by the Planck satellite results. In particular, low-resolution observations of dust polarization have demonstrated that Galactic filamentary structures, where star formation takes place, are associated to wel…
▽ More
Magnetic fields, which play a major role in a large number of astrophysical processes from galactic to cosmological scales, can be traced via observations of dust polarization as demonstrated by the Planck satellite results. In particular, low-resolution observations of dust polarization have demonstrated that Galactic filamentary structures, where star formation takes place, are associated to well organized magnetic fields. A better understanding of this process requires detailed observations of galactic dust polarization on scales of 0.01 to 0.1 pc. Such high-resolution polarization observations can be carried out at the IRAM 30 m telescope using the recently installed NIKA2 camera, which features two frequency bands at 260 and 150 GHz (respectively 1.15 and 2.05 mm), the 260 GHz band being polarization sensitive. NIKA2 so far in commissioning phase, has its focal plane filled with ~3300 detectors to cover a Field of View (FoV) of 6.5 arcminutes diameter. The NIKA camera, which consisted of two arrays of 132 and 224 Lumped Element Kinetic Inductance Detectors (LEKIDs) and a FWHM (Full-Width-Half-Maximum) of 12 and 18.2 arcsecond at 1.15 and 2.05 mm respectively, has been operated at the IRAM 30 m telescope from 2012 to 2015 as a test-bench for NIKA2. NIKA was equipped of a room temperature polarization system (a half wave plate (HWP) and a grid polarizer facing the NIKA cryostat window). The fast and continuous rotation of the HWP permits the quasi simultaneous reconstruction of the three Stokes parameters, I, Q and U at 150 and 260 GHz. This paper presents the first polarization measurements with KIDs and reports the polarization performance of the NIKA camera and the pertinence of the choice of the polarization setup in the perspective of NIKA2. (abridged)
△ Less
Submitted 24 February, 2017; v1 submitted 7 September, 2016;
originally announced September 2016.
-
The NIKA2 commissioning campaign: performance and first results
Authors:
A. Catalano,
R. Adam,
P. Ade,
P. André,
H. Aussel,
A. Beelen,
A. Benoît,
A. Bideaud,
N. Billot,
O. Bourrion,
M. Calvo,
G. Coiffard,
B. Comis,
F. -X. Désert,
S. Doyle,
J. Goupy,
C. F. Kramer,
G. Lagache,
S. Leclercq,
J. F. Lestrade,
J. F. Macías-Pérez,
A. Maury,
P. Mauskopf,
F. Mayet,
A. Monfardini
, et al. (17 additional authors not shown)
Abstract:
The New IRAM KID Array 2 (NIKA 2) is a dual-band camera operating with three frequency-multiplexed kilopixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK. NIKA 2 is designed to observe the intensity and polarisation of the sky at 1.15 and 2.0 mm wavelength from the IRAM 30 m telescope. The NIKA 2 instrument represents a huge step in performance as compared to the…
▽ More
The New IRAM KID Array 2 (NIKA 2) is a dual-band camera operating with three frequency-multiplexed kilopixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK. NIKA 2 is designed to observe the intensity and polarisation of the sky at 1.15 and 2.0 mm wavelength from the IRAM 30 m telescope. The NIKA 2 instrument represents a huge step in performance as compared to the NIKA pathfinder instrument, which has already shown state-of-the-art detector and photometric performance. After the commissioning planned to be accomplished at the end of 2016, NIKA 2 will be an IRAM resident instrument for the next ten years or more. NIKA 2 should allow the astrophysical community to tackle a large number of open questions reaching from the role of the Galactic magnetic field in star formation to the discrepancy between cluster-based and CMB-based cosmology possibly induced by the unknown cluster physics. We present an overview of the commissioning phase together with some first results.
△ Less
Submitted 31 May, 2016; v1 submitted 27 May, 2016;
originally announced May 2016.
-
NIKEL_AMC: Readout electronics for the NIKA2 experiment
Authors:
O. Bourrion,
A. Benoit,
J. L. Bouly,
J. Bouvier,
G. Bosson,
M. Calvo,
A. Catalano,
J. Goupy,
C. Li,
J. F. Macías-Pérez,
A. Monfardini,
D. Tourres,
N. Ponchant,
C. Vescovi
Abstract:
The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays installed in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically de…
▽ More
The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays installed in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically designed electronics, composed of 20 readout boards and hosted in three microTCA crates, has been developed. The implemented solution and the achieved performances are presented in this paper. We find that multiplexing factors of up to 400 detectors per board can be achieved with homogeneous performance across boards in real observing conditions, and a factor of more than 3 decrease in volume with respect to previous generations.
△ Less
Submitted 25 October, 2016; v1 submitted 3 February, 2016;
originally announced February 2016.
-
Uniform non-stoichiometric titanium nitride thin films for improved kinetic inductance detector array
Authors:
G. Coiffard,
K-F. Schuster,
E. F. C. Driessen,
S. Pignard,
M. Calvo,
A. Catalano,
J. Goupy,
A. Monfardini
Abstract:
We describe the fabrication of homogeneous sub-stoichiometric titanium nitride films for microwave kinetic inductance detector (mKID) arrays. Using a 6 inch sputtering target and a homogeneous nitrogen inlet, the variation of the critical temperature over a 2 inch wafer was reduced to <25 %. Measurements of a 132-pixel mKID array from these films reveal a sensitivity of 16 kHz/pW in the 100 GHz ba…
▽ More
We describe the fabrication of homogeneous sub-stoichiometric titanium nitride films for microwave kinetic inductance detector (mKID) arrays. Using a 6 inch sputtering target and a homogeneous nitrogen inlet, the variation of the critical temperature over a 2 inch wafer was reduced to <25 %. Measurements of a 132-pixel mKID array from these films reveal a sensitivity of 16 kHz/pW in the 100 GHz band, comparable to the best aluminium mKIDs. We measured a noise equivalent power of NEP = 3.6e-15 W/Hz^(1/2). Finally, we describe possible routes to further improve the performance of these TiN mKID arrays.
△ Less
Submitted 7 January, 2016; v1 submitted 7 October, 2015;
originally announced October 2015.
-
High-energy interactions in Kinetic Inductance Detectors arrays
Authors:
A. D'Addabbo,
M. Calvo,
J. Goupy,
A. Benoit,
O. Bourrion,
A. Catalano,
J. F. Macias-Perez,
A. Monfardini
Abstract:
The impacts of Cosmic Rays on the detectors are a key problem for space-based missions. We are studying the effects of such interactions on arrays of Kinetic Inductance Detectors (KID), in order to adapt this technology for use on board of satellites. Before proposing a new technology such as the Kinetic Inductance Detectors for a space-based mission, the problem of the Cosmic Rays that hit the de…
▽ More
The impacts of Cosmic Rays on the detectors are a key problem for space-based missions. We are studying the effects of such interactions on arrays of Kinetic Inductance Detectors (KID), in order to adapt this technology for use on board of satellites. Before proposing a new technology such as the Kinetic Inductance Detectors for a space-based mission, the problem of the Cosmic Rays that hit the detectors during in-flight operation has to be studied in detail. We present here several tests carried out with KID exposed to radioactive sources, which we use to reproduce the physical interactions induced by primary Cosmic Rays, and we report the results obtained adopting different solutions in terms of substrate materials and array geometries. We conclude by outlining the main guidelines to follow for fabricating KID for space-based applications.
△ Less
Submitted 7 May, 2015;
originally announced May 2015.