Brain PET-MR attenuation correction with deep learning: method validation in adult and clinical paediatric data
Authors:
Siti N. Yaakub,
Colm J. McGinnity,
Eric Kerfoot,
Ines Mérida,
Katherine Beck,
Eric Dunston,
Marica Muffoletto,
Suryava Bhattacharya,
Ahmed Qureshi,
Joel Dunn,
Jane MacKewn,
Alexander Hammers
Abstract:
Current methods for magnetic resonance-based positron emission tomography attenuation correction (PET-MR AC) are time consuming, and less able than computed tomography (CT)-based AC methods to capture inter-individual variability and skull abnormalities. Deep learning methods have been proposed to produce pseudo-CT from MR images, but these methods have not yet been evaluated in large clinical coh…
▽ More
Current methods for magnetic resonance-based positron emission tomography attenuation correction (PET-MR AC) are time consuming, and less able than computed tomography (CT)-based AC methods to capture inter-individual variability and skull abnormalities. Deep learning methods have been proposed to produce pseudo-CT from MR images, but these methods have not yet been evaluated in large clinical cohorts. Methods trained on healthy adult data may not work in clinical cohorts where skull morphometry may be abnormal, or in paediatric data where skulls tend to be thinner and smaller. Here, we train a convolutional neural network based on the U-Net to produce pseudo-CT for PET-MR AC. We trained our network on a mixed cohort of healthy adults and patients undergoing clinical PET scans for neurology investigations. We show that our method was able to produce pseudo-CT with mean absolute errors (MAE) of 100.4 $\pm$ 21.3 HU compared to reference CT, with a Jaccard overlap coefficient of 0.73 $\pm$ 0.07 in the skull masks. Linear attenuation maps based on our pseudo-CT (relative MAE = 8.4 $\pm$ 2.1\%) were more accurate than those based on a well-performing multi-atlas-based AC method (relative MAE = 13.1 $\pm$ 1.5\%) when compared with CT-based linear attenuation maps. We refined the trained network in a clinical paediatric cohort. MAE improved from 174.7 $\pm$ 33.6 HU when using the existing network to 127.3 $\pm$ 39.9 HU after transfer learning in the paediatric dataset, thus showing that transfer learning can improve pseudo-CT accuracy in paediatric data.
△ Less
Submitted 2 December, 2022;
originally announced December 2022.
-
Pseudo-CTs from T1-weighted MRI for planning of low-intensity transcranial focused ultrasound neuromodulation: an open-source tool
Authors:
Siti Nurbaya Yaakub,
Tristan A. White,
Eric Kerfoot,
Lennart Verhagen,
Alexander Hammers,
Elsa F. Fouragnan
Abstract:
Background: Individual skull models of bone density and geometry are important when planning the expected transcranial ultrasound acoustic field and estimating mechanical and thermal safety in low-intensity transcranial ultrasound stimulation (TUS) studies. Computed tomography (CT) images have typically been used to estimate skull acoustic properties. However, obtaining CT images in research parti…
▽ More
Background: Individual skull models of bone density and geometry are important when planning the expected transcranial ultrasound acoustic field and estimating mechanical and thermal safety in low-intensity transcranial ultrasound stimulation (TUS) studies. Computed tomography (CT) images have typically been used to estimate skull acoustic properties. However, obtaining CT images in research participants may be prohibitive due to exposure to ionising radiation and limited access to CT scanners within research groups.
Objective: We present a validated open-source tool for researchers to obtain individual skull estimates from T1-weighted MR images, for use in acoustic simulations.
Methods: We refined a previously trained and validated 3D convolutional neural network (CNN) to generate 100 keV pseudo-CTs. The network was pretrained on 110 individuals and refined and tested on a database of 37 healthy control individuals. We compared simulations based on reference CTs to simulations based on our pseudo-CTs and binary skull masks, a common alternative in the absence of CT.
Results: Compared with reference CTs, our CNN produced pseudo-CTs with a mean absolute error of 109.8 +/- 13.0 HU across the whole head and 319.3 +/- 31.9 HU in the skull. In acoustic simulations, the focal pressure was statistically equivalent for simulations based on reference CT and pseudo-CT (0.48 +/- 0.04 MPa and 0.50 +/- 0.04 MPa respectively) but not for binary skull masks (0.28 +/- 0.05 MPa).
Conclusions: We show that our network can produce pseudo-CT comparable to reference CTs in healthy individuals, and that these can be used in acoustic simulations.
△ Less
Submitted 24 September, 2022;
originally announced September 2022.
-
Motion-corrected and high-resolution anatomically-assisted (MOCHA) reconstruction of arterial spin labelling MRI
Authors:
Abolfazl Mehranian,
Colm J. McGinnity,
Radhouene Neji,
Claudia Prieto,
Alexander Hammers,
Enrico De Vita,
Andrew J. Reader
Abstract:
A model-based reconstruction framework is proposed for MOtion-Corrected and High-resolution anatomically-Assisted (MOCHA) reconstruction of ASL data. In this framework, all low-resolution ASL control-label pairs are used to reconstruct a single high-resolution cerebral blood flow (CBF) map, corrected for rigid motion, point-spread-function (PSF) blurring and partial-volume effect (PVE).Six volunte…
▽ More
A model-based reconstruction framework is proposed for MOtion-Corrected and High-resolution anatomically-Assisted (MOCHA) reconstruction of ASL data. In this framework, all low-resolution ASL control-label pairs are used to reconstruct a single high-resolution cerebral blood flow (CBF) map, corrected for rigid motion, point-spread-function (PSF) blurring and partial-volume effect (PVE).Six volunteers were recruited for CBF imaging using PCASL labelling, 2-shot 3D-GRASE sequences and high-resolution T1-weighted MRI. For two volunteers, high-resolution scans with double and triple resolution in the partition direction were additionally collected. Simulations were designed for evaluations against a high-resolution ground-truth CBF map, including a simulated hyper-perfused lesion and hyper/hypo-perfusion abnormalities. MOCHA was compared to standard reconstruction and a 3D linear regression (3DLR) PVE correction method and was further evaluated for acquisitions with reduced control-label pairs and k-space undersampling. MOCHA reconstructions of low-resolution ASL data showed enhanced image quality particularly in the partition direction. In simulations, both MOCHA and 3DLR provided more accurate CBF maps than the standard reconstruction, however MOCHA resulted in the lowest errors and well delineated the abnormalities. MOCHA reconstruction of standard-resolution in-vivo data showed good agreement with higher-resolution scans requiring 4x and 9x longer acquisitions. MOCHA was found to be robust for 4x-accelerated ASL acquisitions, achieved by reduced control-label pairs or k-space undersampling. Conclusion: MOCHA reconstruction reduces PVE by direct reconstruction of CBF maps in the high-resolution space of the corresponding anatomical image, incorporating motion correction and PSF modelling. Following further evaluation, MOCHA should promote the clinical application of ASL.
△ Less
Submitted 28 September, 2019;
originally announced September 2019.