-
Reactor Antineutrino Directionality Measurement with the PROSPECT-I Detector
Authors:
M. Andriamirado,
B. Balantekin,
C. D. Bass,
O. Benevides Rodrigues,
E. P. Bernard,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
G. Deichert,
M. J. Dolinski,
A. Erickson,
A. Galindo-Uribarri,
S. Gokhale,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron,
D. E. Jaffe,
S. Jayakumar,
D. C. Jones,
J. R. Koblanski,
P. Kunkle
, et al. (24 additional authors not shown)
Abstract:
The PROSPECT-I detector has several features that enable measurement of the direction of a compact neutrino source. In this paper, a detailed report on the directional measurements made on electron antineutrinos emitted from the High Flux Isotope Reactor is presented. With an estimated true neutrino (reactor to detector) direction of $φ= 40.8\unicode{xB0} \pm 0.7\unicode{xB0}$ and…
▽ More
The PROSPECT-I detector has several features that enable measurement of the direction of a compact neutrino source. In this paper, a detailed report on the directional measurements made on electron antineutrinos emitted from the High Flux Isotope Reactor is presented. With an estimated true neutrino (reactor to detector) direction of $φ= 40.8\unicode{xB0} \pm 0.7\unicode{xB0}$ and $θ= 98.6\unicode{xB0} \pm 0.4\unicode{xB0}$, the PROSPECT-I detector is able to reconstruct an average neutrino direction of $φ= 39.4\unicode{xB0} \pm 2.9\unicode{xB0}$ and $θ= 97.6\unicode{xB0} \pm 1.6\unicode{xB0}$. This measurement is made with approximately 48000 Inverse Beta Decay signal events and is the most precise directional reconstruction of reactor antineutrinos to date.
△ Less
Submitted 11 July, 2024; v1 submitted 12 June, 2024;
originally announced June 2024.
-
Calibration strategy of the PROSPECT-II detector with external and intrinsic sources
Authors:
M. Andriamirado,
A. B. Balantekin,
C. D. Bass,
D. E. Bergeron,
E. P. Bernard,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
A. Delgado,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribarri,
C. E. Gilbert,
S. Gokhale,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron,
D. E. Jaffe
, et al. (36 additional authors not shown)
Abstract:
This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear se…
▽ More
This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. The expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.
△ Less
Submitted 10 April, 2023; v1 submitted 17 November, 2022;
originally announced November 2022.
-
Theory of Nonlinear Acoustic Forces Acting on Inhomogeneous Fluids
Authors:
Varun Kumar Rajendran,
Sujith Jayakumar,
Mohammed Azharudeen,
Karthick Subramani
Abstract:
Recently, the phenomena of streaming suppression and relocation of inhomogeneous miscible fluids under acoustic fields were explained using the hypothesis on mean Eulerian pressure. In this letter, we show that this hypothesis is unsound and any assumption on mean Eulerian pressure is needless. We present a theory of non-linear acoustics for inhomogeneous fluids from the first principles, which ex…
▽ More
Recently, the phenomena of streaming suppression and relocation of inhomogeneous miscible fluids under acoustic fields were explained using the hypothesis on mean Eulerian pressure. In this letter, we show that this hypothesis is unsound and any assumption on mean Eulerian pressure is needless. We present a theory of non-linear acoustics for inhomogeneous fluids from the first principles, which explains streaming suppression and acoustic relocation in both miscible and immiscible inhomogeneous fluids inside a microchannel. This theory predicts the relocation of higher impedance fluids to pressure nodes of the standing wave, which agrees with the recent experiments.
△ Less
Submitted 26 August, 2021;
originally announced August 2021.
-
PROSPECT-II Physics Opportunities
Authors:
M. Andriamirado,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
G. Deichert,
A. Delgado,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribari,
C. E. Gilbert,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron,
D. E. Jaffe
, et al. (37 additional authors not shown)
Abstract:
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, has made world-leading measurements of reactor antineutrinos at short baselines. In its first phase, conducted at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, PROSPECT produced some of the strongest limits on eV-scale sterile neutrinos, made a precision measurement of the reactor antineutrino spectrum fr…
▽ More
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, has made world-leading measurements of reactor antineutrinos at short baselines. In its first phase, conducted at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, PROSPECT produced some of the strongest limits on eV-scale sterile neutrinos, made a precision measurement of the reactor antineutrino spectrum from $^{235}$U, and demonstrated the observation of reactor antineutrinos in an aboveground detector with good energy resolution and well-controlled backgrounds. The PROSPECT collaboration is now preparing an upgraded detector, PROSPECT-II, to probe yet unexplored parameter space for sterile neutrinos and contribute to a full resolution of the Reactor Antineutrino Anomaly, a longstanding puzzle in neutrino physics. By pressing forward on the world's most precise measurement of the $^{235}$U antineutrino spectrum and measuring the absolute flux of antineutrinos from $^{235}$U, PROSPECT-II will sharpen a tool with potential value for basic neutrino science, nuclear data validation, and nuclear security applications. Following a two-year deployment at HFIR, an additional PROSPECT-II deployment at a low enriched uranium reactor could make complementary measurements of the neutrino yield from other fission isotopes. PROSPECT-II provides a unique opportunity to continue the study of reactor antineutrinos at short baselines, taking advantage of demonstrated elements of the original PROSPECT design and close access to a highly enriched uranium reactor core.
△ Less
Submitted 3 September, 2022; v1 submitted 8 July, 2021;
originally announced July 2021.
-
Vector mode decay in atmospheric turbulence: a quantum inspired analysis
Authors:
Isaac Nape,
Nikiwe Mashaba,
Nokwazi Mphuthi,
Sruthy Jayakumar,
Shanti Bhattacharya,
Andrew Forbes
Abstract:
Vector beams are inhomogeneously polarized optical fields with nonseparable, quantum-like correlations between their polarisation and spatial components, and hold tremendous promise for classical and quantum communication across various channels, e.g. the atmosphere, underwater, and in optical fibre. Here we show that by exploiting their quantum-like features by virtue of the nonseparability of th…
▽ More
Vector beams are inhomogeneously polarized optical fields with nonseparable, quantum-like correlations between their polarisation and spatial components, and hold tremendous promise for classical and quantum communication across various channels, e.g. the atmosphere, underwater, and in optical fibre. Here we show that by exploiting their quantum-like features by virtue of the nonseparability of the field, the decay of both the polarisation and spatial components can be studied in tandem. In particular, we invoke the principle of channel state duality to show that the degree of nonseparability of any vector mode is purely determined by that of a maximally nonseparable one, which we confirm using orbital angular momentum (OAM) as an example for topological charges of l = 1 and l = 10 in a turbulent atmosphere. A consequence is that the well-known cylindrical vector vortex beams are sufficient to predict the behaviour of all vector OAM states through the channel, and find that the rate of decay in vector quality decreases with increasing OAM value, even though the spread in OAM is opposite, increasing with OAM. Our approach offers a fast and easy probe of noisy channels, while at the same time revealing the power of quantum tools applied to classical light.
△ Less
Submitted 30 November, 2020;
originally announced November 2020.
-
Performance evaluation of organic emulsion liquid membrane on phenol removal
Authors:
Y. S. Ng,
N. S. Jayakumar,
M. A. Hashim
Abstract:
The percentage removal of phenol from aqueous solution by emulsion liquid membrane and emulsion leakage was investigated experimentally for various parameters such as membrane:internal phase ratio, membrane:external phase ratio, emulsification speed, emulsification time, carrier concentration, surfactant concentration and internal agent concentration. These parameters strongly influence the percen…
▽ More
The percentage removal of phenol from aqueous solution by emulsion liquid membrane and emulsion leakage was investigated experimentally for various parameters such as membrane:internal phase ratio, membrane:external phase ratio, emulsification speed, emulsification time, carrier concentration, surfactant concentration and internal agent concentration. These parameters strongly influence the percentage removal of phenol and emulsion leakage. Under optimum membrane properties, the percentage removal of phenol was as high as 98.33%, with emulsion leakage of 1.25%. It was also found that the necessity of carrier for enhancing phenol removal was strongly dependent on the internal agent concentration.
△ Less
Submitted 30 November, 2014;
originally announced December 2014.
-
Behavior of hydrophobic ionic liquids as liquid membranes on phenol removal: Experimental study and optimization
Authors:
Y. S. Ng,
N. S. Jayakumar,
M. A. Hashim
Abstract:
Room temperature ionic liquids show potential as an alternative to conventional organic membrane solvents mainly due to their properties of low vapor pressure, low volatility and they are often stable. In the present work, the technical feasibilities of room temperature ionic liquids as bulk liquid membranes for phenol removal were investigated experimentally. Three ionic liquids with high hydroph…
▽ More
Room temperature ionic liquids show potential as an alternative to conventional organic membrane solvents mainly due to their properties of low vapor pressure, low volatility and they are often stable. In the present work, the technical feasibilities of room temperature ionic liquids as bulk liquid membranes for phenol removal were investigated experimentally. Three ionic liquids with high hydrophobicity were used and their phenol removal efficiency, membrane stability and membrane loss were studied. Besides that, the effects of several parameters, namely feed phase pH, feed concentration, NaOH concentration and stirring speeds on the performance of best ionic liquid membrane were also evaluated. Lastly, an optimization study on bulk ionic liquid membrane was conducted and the maximum phenol removal efficiency was compared with the organic liquid membranes. The preliminary study shows that high phenol extraction and stripping efficiencies of 96.21% and 98.10%, respectively can be achieved by ionic liquid membrane with a low membrane loss which offers a better choice to organic membrane solvents.
△ Less
Submitted 30 November, 2014;
originally announced December 2014.