Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–9 of 9 results for author: Kamon, T

Searching in archive physics. Search in all archives.
.
  1. arXiv:2203.12037  [pdf, other

    physics.ins-det hep-ex

    Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade

    Authors: M. Abbas, M. Abbrescia, H. Abdalla, A. Abdelalim, S. AbuZeid, A. Agapitos, A. Ahmad, A. Ahmed, W. Ahmed, C. Aimè, C. Aruta, I. Asghar, P. Aspell, C. Avila, J. Babbar, Y. Ban, R. Band, S. Bansal, L. Benussi, T. Beyrouthy, V. Bhatnagar, M. Bianco, S. Bianco, K. Black, L. Borgonovi , et al. (157 additional authors not shown)

    Abstract: The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton co… ▽ More

    Submitted 22 March, 2022; originally announced March 2022.

    Comments: 45 pages, 39 figures, submitted to Nuclear Instruments and Methods in Physics Research Section A

  2. arXiv:2112.00118  [pdf, other

    physics.ins-det hep-ex

    Impact of the hole orientation of asymmetric GEM foils on the performance of single and triple GEM detectors

    Authors: Othmane Bouhali, Kerstin Hoepfner, Francesco Ivone, Teruki Kamon, Henning Keller, Shivali Malhotra, Badriya Al Rashdi

    Abstract: The Gas Electron Multiplier (GEM) foil is an amplification stage that has been introduced to overcome the problem of discharges observed in gaseous detectors. There are two major production techniques of GEM foils: double-mask and single-mask etching. Despite being an effective method, an asymmetry is observed between the top and bottom diameters of GEM holes in single mask compared to double mask… ▽ More

    Submitted 30 November, 2021; originally announced December 2021.

    Journal ref: JINST 16 (2021) P10032

  3. arXiv:2107.09364  [pdf, other

    physics.ins-det hep-ex

    Performance of a Triple-GEM Demonstrator in $pp$ Collisions at the CMS Detector

    Authors: M. Abbas, M. Abbrescia, H. Abdalla, A. Abdelalim, S. AbuZeid, A. Agapitos, A. Ahmad, A. Ahmed, W. Ahmed, C. Aimè, C. Aruta, I. Asghar, P. Aspell, C. Avila, J. Babbar, Y. Ban, R. Band, S. Bansal, L. Benussi, V. Bhatnagar, M. Bianco, S. Bianco, K. Black, L. Borgonovi, O. Bouhali , et al. (156 additional authors not shown)

    Abstract: After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstr… ▽ More

    Submitted 22 September, 2021; v1 submitted 20 July, 2021; originally announced July 2021.

    Comments: 10 pages, 5 figures

  4. arXiv:2107.03621  [pdf, other

    physics.ins-det hep-ex

    Modeling the triple-GEM detector response to background particles for the CMS Experiment

    Authors: M. Abbas, M. Abbrescia, H. Abdalla, A. Abdelalim, S. AbuZeid, A. Agapitos, A. Ahmad, A. Ahmed, W. Ahmed, C. Aimè, C. Aruta, I. Asghar, P. Aspell, C. Avila, I. Azhgirey, J. Babbar, Y. Ban, R. Band, S. Bansal, L. Benussi, V. Bhatnagar, M. Bianco, S. Bianco, K. Black, L. Borgonovi , et al. (164 additional authors not shown)

    Abstract: An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The… ▽ More

    Submitted 8 July, 2021; originally announced July 2021.

    Comments: 16 pages, 9 figures, 6 tables

  5. arXiv:2009.09505  [pdf, other

    physics.ins-det hep-ex

    Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade

    Authors: M. Abbas, M. Abbrescia, H. Abdalla, A. Abdelalim, S. AbuZeid, A. Agapitos, A. Ahmad, A. Ahmed, W. Ahmed, C. Aimè, C. Aruta, I. Asghar, P. Aspell, C. Avila, J. Babbar, Y. Ban, R. Band, S. Bansal, L. Benussi, V. Bhatnagar, M. Bianco, S. Bianco, K. Black, L. Borgonovi, O. Bouhali , et al. (156 additional authors not shown)

    Abstract: We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequent… ▽ More

    Submitted 20 September, 2020; originally announced September 2020.

    Comments: 22 pages, 14 figures

    Journal ref: 2020 JINST 15 P12019

  6. arXiv:1512.08529  [pdf, ps, other

    physics.ins-det

    A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

    Authors: D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Akl, O. Aboamer, D. Acosta, A. Ahmad, W. Ahmed, W. Ahmed, A. Aleksandrov, R. Aly, P. Altieri, C. Asawatangtrakuldee, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, V. Barashko, P. Barria, G. Bencze, N. Beni, L. Benussi , et al. (133 additional authors not shown)

    Abstract: We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active are… ▽ More

    Submitted 28 December, 2015; originally announced December 2015.

    Comments: 4 pages, 4 figures, presented by Luigi Benussi at MPGD 2015 (Trieste, Italy). arXiv admin note: text overlap with arXiv:1512.08481

    Report number: INFN-15-10/LNF

  7. Fiber Bragg Grating (FBG) sensors as flatness and mechanical stretching sensors

    Authors: D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Akl, O. Aboamer, D. Acosta, A. Ahmad, W. Ahmed, W. Ahmed, A. Aleksandrov, R. Aly, P. Altieri, C. Asawatangtrakuldee, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, V. Barashko, P. Barria, G. Bencze, N. Beni, L. Benussi , et al. (133 additional authors not shown)

    Abstract: A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and preliminary results are presented.

    Submitted 28 December, 2015; originally announced December 2015.

    Comments: Two pages, one figure. Presented by Luigi Benussi (corresponding author) to Elba 2015 conference

    Report number: Frascati Preprint INFN-15-09/LNF

  8. arXiv:1412.0228  [pdf, other

    physics.ins-det

    Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

    Authors: D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Akl, W. Ahmed, W. Ahmed, P. Altieri, R. Aly, C. Asawatangtrakuldee, A. Ashfaq, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, P. Barria, L. Benussi, V. Bhopatkar, S. Bianco, J. Bos, O. Bouhali, S. Braibant, S. Buontempo , et al. (113 additional authors not shown)

    Abstract: Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips wi… ▽ More

    Submitted 8 December, 2014; v1 submitted 30 November, 2014; originally announced December 2014.

    Comments: 8 pages, 32 figures, submitted to Proc. 2014 IEEE Nucl. Sci. Symposium, Seattle, WA, reference added

  9. The Timing System for the CDF Electromagnetic Calorimeters

    Authors: M. Goncharov, T. Kamon, V. Khotilovich, V. Krutelyov, S. W. Lee, D. Toback, P. Wagner, H. Frisch, H. Sanders, M. Cordelli, F. Happacher, S. Miscetti, R. Wagner

    Abstract: We report on the design and performance of the electromagnetic calorimeter timing readout system (EMTiming) for the Collider Detector at Fermilab (CDF). The system will be used in searches for rare events with high energy photons to verify that the photon is in time with the event collision, to reject cosmic ray and beam halo backgrounds, and to allow direct searches for new heavy long-lived par… ▽ More

    Submitted 19 December, 2005; originally announced December 2005.

    Comments: 9 pages, 7 figures. Submitted to Nuclear Instruments and Methods. Cross listed on hep-ex

    Report number: FERMILAB-PUB-05-543-E

    Journal ref: Nucl.Instrum.Meth.A565:543-550,2006