A historical perspective on Modified Newtonian Dynamics
Authors:
R. H. Sanders
Abstract:
I review the history and development of Modified Newtonian Dynamics (MOND) beginning with the phenomenological basis as it existed in the early 1980s. I consider Milgrom's papers of 1983 introducing the idea and its consequences for galaxies and galaxy groups, as well as the initial reactions, both negative and positive. The early criticisms were primarily on matters of principle, such as the abse…
▽ More
I review the history and development of Modified Newtonian Dynamics (MOND) beginning with the phenomenological basis as it existed in the early 1980s. I consider Milgrom's papers of 1983 introducing the idea and its consequences for galaxies and galaxy groups, as well as the initial reactions, both negative and positive. The early criticisms were primarily on matters of principle, such as the absence of conservation laws and perceived cosmological problems; an important step in addressing these issues was the development of the Lagrangian-based non-relativistic theory of Bekenstein and Milgrom. This theory led to the development of a tentative relativistic theory that formed the basis for later multi-field theories of gravity. On an empirical level the predictive success of the idea with respect to the phenomenology of galaxies presents considerable challenges for cold dark matter. For MOND the essential challenge remains the absence of a generally accepted theoretical underpinning of the idea and, thus, cosmological predictions. I briefly review recent progress in this direction. Finally I discuss the role and sociology of unconventional ideas in astronomy in the presence of a strongly entrenched standard paradigm.
△ Less
Submitted 29 July, 2014; v1 submitted 1 April, 2014;
originally announced April 2014.
-
Reflections on the direct detection of particle dark matter
Authors:
R. H. Sanders
Abstract:
The LUX experimental group has just announced the most stringent upper limits so far obtained on the cross section of WIMP-nucleon elastic scattering [1]. This result is a factor of two to five below the previous best upper limit [2] and effectively rules out earlier suggestions of low mass WIMP detection signals. The experimental expertise exhibited by this group is extremely impressive, but the…
▽ More
The LUX experimental group has just announced the most stringent upper limits so far obtained on the cross section of WIMP-nucleon elastic scattering [1]. This result is a factor of two to five below the previous best upper limit [2] and effectively rules out earlier suggestions of low mass WIMP detection signals. The experimental expertise exhibited by this group is extremely impressive, but the fact of continued negative results raises the more basic question of whether or not this is the right approach to solving the dark matter problem. Here I comment upon this question, using as a basis the final chapter of my book on dark matter [3], somewhat revised and extended. I muse on dark matter and its alternative, modified Newtonian dynamics, or MOND.
△ Less
Submitted 7 November, 2013;
originally announced November 2013.
-
The Timing System for the CDF Electromagnetic Calorimeters
Authors:
M. Goncharov,
T. Kamon,
V. Khotilovich,
V. Krutelyov,
S. W. Lee,
D. Toback,
P. Wagner,
H. Frisch,
H. Sanders,
M. Cordelli,
F. Happacher,
S. Miscetti,
R. Wagner
Abstract:
We report on the design and performance of the electromagnetic calorimeter timing readout system (EMTiming) for the Collider Detector at Fermilab (CDF). The system will be used in searches for rare events with high energy photons to verify that the photon is in time with the event collision, to reject cosmic ray and beam halo backgrounds, and to allow direct searches for new heavy long-lived par…
▽ More
We report on the design and performance of the electromagnetic calorimeter timing readout system (EMTiming) for the Collider Detector at Fermilab (CDF). The system will be used in searches for rare events with high energy photons to verify that the photon is in time with the event collision, to reject cosmic ray and beam halo backgrounds, and to allow direct searches for new heavy long-lived particles that decay to photons. The installation and commissioning of all 862 channels was completed in Fall 2004 as part of an upgrade to the Run II version of the detector. Using in-situ data, including electrons from W=>e nu and Z => ee decays, we measure the energy threshold for a time to be recorded to be 3.8 \pm 0.3GeV in the central portion of the detector and 1.9 \pm 0.1 GeV in the plug portion. Similarly, we measure a timing resolution of 600 \pm 10 ps and 610 \pm 10 ps for electrons above 10 GeV and 6 GeV respectively. There are very few system pathologies such as recording a time when no energy is deposited, or recording a second, fake time for a single energy deposit.
△ Less
Submitted 19 December, 2005;
originally announced December 2005.
-
A 96-Channel FPGA-based Time-to-Digital Converter
Authors:
Mircea Bogdan,
Henry Frisch,
Mary Heintz,
Alexander Paramonov,
Harold Sanders,
Steve Chappa,
Robert DeMaat,
Rod Klein,
Ting Miao,
Peter Wilson,
Thomas J. Phillips
Abstract:
We describe an FPGA-based, 96-channel, time-to-digital converter (TDC) intended for use with the Central Outer Tracker (COT) in the CDF Experiment at the Fermilab Tevatron. The COT system is digitized and read out by 315 TDC cards, each serving 96 wires of the chamber. The TDC is physically configured as a 9U VME card. The functionality is almost entirely programmed in firmware in two Altera Str…
▽ More
We describe an FPGA-based, 96-channel, time-to-digital converter (TDC) intended for use with the Central Outer Tracker (COT) in the CDF Experiment at the Fermilab Tevatron. The COT system is digitized and read out by 315 TDC cards, each serving 96 wires of the chamber. The TDC is physically configured as a 9U VME card. The functionality is almost entirely programmed in firmware in two Altera Stratix FPGA's. The special capabilities of this device are the availability of 840 MHz LVDS inputs, multiple phase-locked clock modules, and abundant memory. The TDC system operates with an input resolution of 1.2 ns. Each input can accept up to 7 hits per collision. The time-to-digital conversion is done by first sampling each of the 96 inputs in 1.2-ns bins and filling a circular memory; the memory addresses of logical transitions (edges) in the input data are then translated into the time of arrival and width of the COT pulses. Memory pipelines with a depth of 5.5 $μ$s allow deadtime-less operation in the first-level trigger. The TDC VME interface allows a 64-bit Chain Block Transfer of multiple boards in a crate with transfer-rates up to 47 Mbytes/sec. The TDC also contains a separately-programmed data path that produces prompt trigger data every Tevatron crossing. The full TDC design and multi-card test results are described. The physical simplicity ensures low-maintenance; the functionality being in firmware allows reprogramming for other applications.
△ Less
Submitted 11 February, 2005;
originally announced February 2005.