-
Sterile neutrino search at NEOS Experiment
Authors:
Y. J. Ko,
B. R. Kim,
J. Y. Kim,
B. Y. Han,
C. H. Jang,
E. J. Jeon,
K. K. Joo,
H. J. Kim,
H. S. Kim,
Y. D. Kim,
Jaison Lee,
J. Y. Lee,
M. H. Lee,
Y. M. Oh,
H. K. Park,
H. S. Park,
K. S. Park,
K. M. Seo,
Kim Siyeon,
G. M. Sun
Abstract:
An experiment to search for light sterile neutrinos was conducted at a reactor with a thermal power of 2.8 GW located at the Hanbit nuclear power complex. The search was done with a detector consisting of a ton of Gd-loaded liquid scintillator in a tendon gallery approximately 24 m from the reactor core. The measured antineutrino event rate is 1976 per day with a signal to background ratio of abou…
▽ More
An experiment to search for light sterile neutrinos was conducted at a reactor with a thermal power of 2.8 GW located at the Hanbit nuclear power complex. The search was done with a detector consisting of a ton of Gd-loaded liquid scintillator in a tendon gallery approximately 24 m from the reactor core. The measured antineutrino event rate is 1976 per day with a signal to background ratio of about 22. The shape of the antineutrino energy spectrum obtained from eight-month data-taking period is compared with a hypothesis of oscillations due to active-sterile antineutrino mixing. It is found to be consistent with no oscillation. An excess around 5 MeV prompt energy range is observed as seen in existing longer baseline experiments. The parameter space of $\sin^{2}2θ_{14}$ down below 0.1 for $Δm^{2}_{41}$ ranging from 0.2 eV$^{2}$ to 2.3 eV$^{2}$ and the optimum point for the previously reported reactor antineutrino anomaly are excluded with a confidence level higher than 90%.
△ Less
Submitted 21 March, 2017; v1 submitted 17 October, 2016;
originally announced October 2016.
-
Measurement of Fast Neutron Rate for NEOS Experiment
Authors:
Y. J. Ko,
J. Y. Kim,
B. Y. Han,
C. H. Jang,
E. J. Jeon,
K. K. Joo,
B. R. Kim,
H. J. Kim,
H. S. Kim,
Y. D. Kim,
Jaison Lee,
J. Y. Lee,
M. H. Lee,
Y. M. Oh,
H. K. Park,
H. S. Park,
K. S. Park,
K. M. Seo,
Kim Siyeon,
G. M. Sun
Abstract:
The fast neutron rate is measured at the site of NEOS experiment, a short baseline neutrino experiment located in a tendon gallery of a commercial nuclear power plant, using a 0.78-liter liquid scintillator detector. A pulse shape discrimination technique is used to identify neutron signals. The measurements are performed during the nuclear reactor-on and off periods and found to be ~20 per day fo…
▽ More
The fast neutron rate is measured at the site of NEOS experiment, a short baseline neutrino experiment located in a tendon gallery of a commercial nuclear power plant, using a 0.78-liter liquid scintillator detector. A pulse shape discrimination technique is used to identify neutron signals. The measurements are performed during the nuclear reactor-on and off periods and found to be ~20 per day for both periods. The fast neutron rate is also measured at an overground site with a negligible overburden and is found to be ~100 times higher than that at the NEOS experiment site.
△ Less
Submitted 17 October, 2016;
originally announced October 2016.
-
Spectral Measurement of the Electron Antineutrino Oscillation Amplitude and Frequency using 500 Live Days of RENO Data
Authors:
S. H. Seo,
W. Q. Choi,
H. Seo,
J. H. Choi,
Y. Choi,
H. I. Jang,
J. S. Jang,
K. K. Joo,
B. R. Kim,
H. S. Kim,
J. Y. Kim,
S. B. Kim,
S. Y. Kim,
W. Kim,
E. Kwon,
D. H. Lee,
Y. C. Lee,
I. T. Lim,
M. Y. Pac,
I. G. Park,
J. S. Park,
R. G. Park,
Y. G. Seon,
C. D. Shin,
J. H. Yang
, et al. (3 additional authors not shown)
Abstract:
The Reactor Experiment for Neutrino Oscillation (RENO) has been taking electron antineutrino ($\overlineν_{e}$) data from the reactors in Yonggwang, Korea, using two identical detectors since August 2011. Using roughly 500 live days of data through January 2013 we observe 290,775 (31,514) reactor $\overlineν_{e}$ candidate events with 2.8 (4.9)% background in the near (far) detector. The observed…
▽ More
The Reactor Experiment for Neutrino Oscillation (RENO) has been taking electron antineutrino ($\overlineν_{e}$) data from the reactors in Yonggwang, Korea, using two identical detectors since August 2011. Using roughly 500 live days of data through January 2013 we observe 290,775 (31,514) reactor $\overlineν_{e}$ candidate events with 2.8 (4.9)% background in the near (far) detector. The observed visible positron spectra from the reactor $\overlineν_{e}$ events in both detectors show discrepancy around 5 MeV with regard to the prediction from the current reactor $\overlineν_{e}$ model. Based on a far-to-near ratio measurement using the spectral and rate information we have obtained $\sin^2 2 θ_{13} = 0.082 \pm 0.009({\rm stat.}) \pm 0.006({\rm syst.})$ and $|Δm_{ee}^2| =[2.62_{-0.23}^{+0.21}({\rm stat.})_{-0.13}^{+0.12}({\rm syst.})]\times 10^{-3}$eV$^2$.
△ Less
Submitted 16 May, 2018; v1 submitted 14 October, 2016;
originally announced October 2016.
-
In-Situ Measurement of Relative Attenuation Length of Gadolinium-Loaded Liquid Scintillator Using Source Data at RENO Experiment
Authors:
H. S. Kim,
S. Y. Kim,
J. H. Choi,
W. Q. Choi,
Y. Choi,
H. I. Jang,
J. S. Jang,
K. K. Joo,
B. R. Kim,
J. Y. Kim,
S. B. Kim,
W. Kim,
E. Kwon,
D. H. Lee,
I. T. Lim,
M. Y. Pac,
I. G. Park,
J. S. Park,
R. G. Park,
H. Seo,
S. H. Seo,
Y. G. Seon,
C. D. Shin,
I. S. Yeo,
I. Yu
Abstract:
We present in situ measurements of the relative attenuation length of the gadolinium loaded liquid scintillator in the RENO (Reactor Experiment Neutrino Oscillation) detectors using radioactive source calibration data. We observed a steady decrease in the attenuation length of the Gd-LS in the RENO detectors by 50% in about four years since the commissioning of the detectors.
We present in situ measurements of the relative attenuation length of the gadolinium loaded liquid scintillator in the RENO (Reactor Experiment Neutrino Oscillation) detectors using radioactive source calibration data. We observed a steady decrease in the attenuation length of the Gd-LS in the RENO detectors by 50% in about four years since the commissioning of the detectors.
△ Less
Submitted 22 May, 2023; v1 submitted 29 September, 2016;
originally announced September 2016.
-
Development and Mass Production of a Mixture of LAB- and DIN-based Gadolinium-loaded Liquid Scintillator for the NEOS Short-baseline Neutrino Experiment
Authors:
Ba Ro Kim,
Boyoung Han,
Eun-ju Jeon,
Kyung Kwang Joo,
H. J. Kim,
Hyunsoo Kim,
Jinyu Kim,
Yeongduk Kim,
Youngju Ko,
Jaison Lee,
Jooyoung Lee,
Moohyun Lee,
Kyungju Ma,
Yoomin Oh,
Hyangkyu Park,
Kang-soon Park,
Kyungmin Seo,
Gwang-Min Seon,
Kim Siyeon
Abstract:
A new experiment, which is called as NEOS (NEutrino Oscillation at Short baseline), is proposed on the site of Hanbit reactors at Yonggwang, South Korea, to investigate a reactor antineutrino anomaly. A homogeneous NEOS detector having a 1000-L target volume has been constructed and deployed at the tendon gallery ~25 m away from the reactor core. A linear alkylbenzene (LAB) is used as a main base…
▽ More
A new experiment, which is called as NEOS (NEutrino Oscillation at Short baseline), is proposed on the site of Hanbit reactors at Yonggwang, South Korea, to investigate a reactor antineutrino anomaly. A homogeneous NEOS detector having a 1000-L target volume has been constructed and deployed at the tendon gallery ~25 m away from the reactor core. A linear alkylbenzene (LAB) is used as a main base solvent of the NEOS detector. Furthermore, a di-isopropylnaphthalene (DIN) is added to improve the light output and pulse shape discrimination (PSD) ability. The ratio of LAB to DIN is 90:10. PPO (3 g/L) and bis-MSB (30 mg/L) are dissolved to formulate the mixture of LAB- and DIN-based liquid scintillator (LS). Then, ~0.5% gadolinium (Gd) is loaded into the LS by using the solvent-solvent extraction technique. In this paper, we report the characteristics of Gd-loaded LS (GdLS) for the NEOS detector and the handling during mass production.
△ Less
Submitted 16 November, 2015;
originally announced November 2015.
-
Slow Control Systems of the Reactor Experiment for Neutrino Oscillation
Authors:
J. H. Choi,
H. I. Jang,
W. Q. Choi,
Y. Choi,
J. S. Jang,
E. J. Jeon,
K. K. Joo,
B. R. Kim,
H. S. Kim,
J. Y. Kim,
S. B. Kim,
S. Y. Kim,
W. Kim,
Y. D. Kim,
Y. J. Ko,
J. K. Lee,
I. T. Lim,
M. Y. Pac,
I. G. Park,
J. S. Park,
R. G. Park,
H. K. Seo,
C. D. Shin,
K. Siyeon,
I. S. Yeo
, et al. (1 additional authors not shown)
Abstract:
The RENO experiment has been in operation since August 2011 to measure reactor antineutrino disappearance using identical near and far detectors. For accurate measurements of neutrino mixing parameters and efficient data taking, it is crucial to monitor and control the detector in real time. Environmental conditions also need to be monitored for stable operation of detectors as well as for safety…
▽ More
The RENO experiment has been in operation since August 2011 to measure reactor antineutrino disappearance using identical near and far detectors. For accurate measurements of neutrino mixing parameters and efficient data taking, it is crucial to monitor and control the detector in real time. Environmental conditions also need to be monitored for stable operation of detectors as well as for safety reasons. In this article, we report the design, hardware, operation, and performance of the slow control system.
△ Less
Submitted 9 December, 2015; v1 submitted 2 July, 2013;
originally announced July 2013.