An insertable glucose sensor using a compact and cost-effective phosphorescence lifetime imager and machine learning
Authors:
Artem Goncharov,
Zoltan Gorocs,
Ridhi Pradhan,
Brian Ko,
Ajmal Ajmal,
Andres Rodriguez,
David Baum,
Marcell Veszpremi,
Xilin Yang,
Maxime Pindrys,
Tianle Zheng,
Oliver Wang,
Jessica C. Ramella-Roman,
Michael J. McShane,
Aydogan Ozcan
Abstract:
Optical continuous glucose monitoring (CGM) systems are emerging for personalized glucose management owing to their lower cost and prolonged durability compared to conventional electrochemical CGMs. Here, we report a computational CGM system, which integrates a biocompatible phosphorescence-based insertable biosensor and a custom-designed phosphorescence lifetime imager (PLI). This compact and cos…
▽ More
Optical continuous glucose monitoring (CGM) systems are emerging for personalized glucose management owing to their lower cost and prolonged durability compared to conventional electrochemical CGMs. Here, we report a computational CGM system, which integrates a biocompatible phosphorescence-based insertable biosensor and a custom-designed phosphorescence lifetime imager (PLI). This compact and cost-effective PLI is designed to capture phosphorescence lifetime images of an insertable sensor through the skin, where the lifetime of the emitted phosphorescence signal is modulated by the local concentration of glucose. Because this phosphorescence signal has a very long lifetime compared to tissue autofluorescence or excitation leakage processes, it completely bypasses these noise sources by measuring the sensor emission over several tens of microseconds after the excitation light is turned off. The lifetime images acquired through the skin are processed by neural network-based models for misalignment-tolerant inference of glucose levels, accurately revealing normal, low (hypoglycemia) and high (hyperglycemia) concentration ranges. Using a 1-mm thick skin phantom mimicking the optical properties of human skin, we performed in vitro testing of the PLI using glucose-spiked samples, yielding 88.8% inference accuracy, also showing resilience to random and unknown misalignments within a lateral distance of ~4.7 mm with respect to the position of the insertable sensor underneath the skin phantom. Furthermore, the PLI accurately identified larger lateral misalignments beyond 5 mm, prompting user intervention for re-alignment. The misalignment-resilient glucose concentration inference capability of this compact and cost-effective phosphorescence lifetime imager makes it an appealing wearable diagnostics tool for real-time tracking of glucose and other biomarkers.
△ Less
Submitted 11 June, 2024;
originally announced June 2024.
-
Enhanced tunable cavity development for axion dark matter searches using a piezoelectric motor in combination with gears
Authors:
A. K. Yi,
T. Seong,
S. Lee,
S. Ahn,
B. I. Ivanov,
S. V. Uchaikin,
B. R. Ko,
Y. K. Semertzidis
Abstract:
Most search experiments sensitive to quantum chromodynamics (QCD) axion dark matter benefit from microwave cavities, as electromagnetic resonators, that enhance the detectable axion signal power and thus the experimental sensitivity drastically. As the possible axion mass spans multiple orders of magnitude, microwave cavities must be tunable and it is desirable for the cavity to have a tunable fre…
▽ More
Most search experiments sensitive to quantum chromodynamics (QCD) axion dark matter benefit from microwave cavities, as electromagnetic resonators, that enhance the detectable axion signal power and thus the experimental sensitivity drastically. As the possible axion mass spans multiple orders of magnitude, microwave cavities must be tunable and it is desirable for the cavity to have a tunable frequency range that is as wide as possible. Since the tunable frequency range generally increases as the dimension of the conductor tuning rod increases for a given cylindrical conductor cavity system, we developed a cavity system with a large dimensional tuning rod in order to increase this. We, for the first time, employed not only a piezoelectric motor, but also gears to drive a large and accordingly heavy tuning rod, where such a combination to increase driving power can be adopted for extreme environments as is the case for axion dark matter experiments: cryogenic, high-magnetic-field, and high vacuum. Thanks to such higher power derived from the piezoelectric motor and gear combination, we realized a wideband tunable cavity whose frequency range is about 42\% of the central resonant frequency of the cavity, without sacrificing the experimental sensitivity too much.
△ Less
Submitted 8 July, 2024; v1 submitted 11 June, 2024;
originally announced June 2024.
-
Dosimetric calibration of an anatomically specific ultra-high dose rate electron irradiation platform for preclinical FLASH radiobiology experiments
Authors:
Jinghui Wang,
Stavros Melemenidis,
Rakesh Manjappa,
Vignesh Viswanathan,
Ramish M. Ashraf,
Karen Levy,
Lawrie Skinner,
Luis A. Soto,
Stephanie Chow,
Brianna Lau,
Ryan B. Ko,
Edward E. Graves,
Amy S. Yu,
Karl K. Bush,
Murat Surucu,
Erinn B. Rankin,
Billy W. Loo Jr,
Emil Schüler,
Peter G. Maxim
Abstract:
We characterized the dosimetric properties of a clinical linear accelerator configured to deliver ultra-high dose rate (UHDR) irradiation to mice and cell-culture FLASH radiobiology experiments. UHDR electron beams were controlled by a microcontroller and relay interfaced with the respiratory gating system. We produced beam collimators with indexed stereotactic mouse positioning devices to provide…
▽ More
We characterized the dosimetric properties of a clinical linear accelerator configured to deliver ultra-high dose rate (UHDR) irradiation to mice and cell-culture FLASH radiobiology experiments. UHDR electron beams were controlled by a microcontroller and relay interfaced with the respiratory gating system. We produced beam collimators with indexed stereotactic mouse positioning devices to provide anatomically specific preclinical treatments. Treatment delivery was monitored directly with an ionization chamber, and charge measurements were correlated with radiochromic film at the entry surface of the mice. The setup for conventional (CONV) dose rate irradiation was similar but the source-to-surface distance was longer. Monte Carlo simulations and film dosimetry were used to characterize beam properties and dose distributions. The mean electron beam energies before the flattening filter were 18.8 MeV (UHDR) and 17.7 MeV (CONV), with corresponding values at the mouse surface of 17.2 MeV and 16.2 MeV. The charges measured with an external ion chamber were linearly correlated with the mouse entrance dose. Use of relay gating for pulse control initially led to a delivery failure rate of 20% ($+/-$ 1 pulse); adjustments to account for the linac latency improved this rate to <1/20. Beam field sizes for two anatomically specific mouse collimators (4x4 $cm^2$ for whole-abdomen and 1.5x1.5 $cm^2$ for unilateral lung irradiation) were accurate within <5% and had low radiation leakage (<4%). Normalizing the dose at the center of the mouse (~0.75 cm depth) produced UHDR and CONV doses to the irradiated volumes with >95% agreement. We successfully configured a clinical linear accelerator for increased output and developed a robust preclinical platform for anatomically specific irradiation, with highly accurate and precise temporal and spatial dose delivery, for both CONV and UHDR applications.
△ Less
Submitted 17 December, 2023;
originally announced December 2023.
-
Heterogeneous reconstruction of deformable atomic models in Cryo-EM
Authors:
Youssef Nashed,
Ariana Peck,
Julien Martel,
Axel Levy,
Bongjin Koo,
Gordon Wetzstein,
Nina Miolane,
Daniel Ratner,
Frédéric Poitevin
Abstract:
Cryogenic electron microscopy (cryo-EM) provides a unique opportunity to study the structural heterogeneity of biomolecules. Being able to explain this heterogeneity with atomic models would help our understanding of their functional mechanisms but the size and ruggedness of the structural space (the space of atomic 3D cartesian coordinates) presents an immense challenge. Here, we describe a heter…
▽ More
Cryogenic electron microscopy (cryo-EM) provides a unique opportunity to study the structural heterogeneity of biomolecules. Being able to explain this heterogeneity with atomic models would help our understanding of their functional mechanisms but the size and ruggedness of the structural space (the space of atomic 3D cartesian coordinates) presents an immense challenge. Here, we describe a heterogeneous reconstruction method based on an atomistic representation whose deformation is reduced to a handful of collective motions through normal mode analysis. Our implementation uses an autoencoder. The encoder jointly estimates the amplitude of motion along the normal modes and the 2D shift between the center of the image and the center of the molecule . The physics-based decoder aggregates a representation of the heterogeneity readily interpretable at the atomic level. We illustrate our method on 3 synthetic datasets corresponding to different distributions along a simulated trajectory of adenylate kinase transitioning from its open to its closed structures. We show for each distribution that our approach is able to recapitulate the intermediate atomic models with atomic-level accuracy.
△ Less
Submitted 29 September, 2022;
originally announced September 2022.
-
Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
T. Beyrouthy,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (157 additional authors not shown)
Abstract:
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton co…
▽ More
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton collisions is expected to exceed $2-3\times10^{34}$~cm$^{-2}$s$^{-1}$ for Run 3 (starting in 2022), and it will be at least $5\times10^{34}$~cm$^{-2}$s$^{-1}$ when the High Luminosity Large Hadron Collider is completed for Run 4. These conditions will affect muon triggering, identification, and measurement, which are critical capabilities of the experiment. To address these challenges, additional muon detectors are being installed in the CMS endcaps, based on Gas Electron Multiplier technology. For this purpose, 161 large triple-Gas Electron Multiplier detectors have been constructed and tested. Installation of these devices began in 2019 with the GE1/1 station and will be followed by two additional stations, GE2/1 and ME0, to be installed in 2023 and 2026, respectively. The assembly and quality control of the GE1/1 detectors were distributed across several production sites around the world. We motivate and discuss the quality control procedures that were developed to standardize the performance of the detectors, and we present the final results of the production. Out of 161 detectors produced, 156 detectors passed all tests, and 144 detectors are now installed in the CMS experiment. The various visual inspections, gas tightness tests, intrinsic noise rate characterizations, and effective gas gain and response uniformity tests allowed the project to achieve this high success rate.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
Development of an FPGA-based realtime DAQ system for axion haloscope experiments
Authors:
MyeongJae Lee,
ByeongRok Ko,
Saebyeok Ahn
Abstract:
A real-time Data Acquisition (DAQ) system for the CULTASK axion haloscope experiment was constructed and tested. The CULTASK is an experiment to search for cosmic axions using resonant cavities, to detect photons from axion conversion through the inverse Primakoff effect in a few GHz frequency range in a very high magnetic field and at an ultra low temperature. The constructed DAQ system utilizes…
▽ More
A real-time Data Acquisition (DAQ) system for the CULTASK axion haloscope experiment was constructed and tested. The CULTASK is an experiment to search for cosmic axions using resonant cavities, to detect photons from axion conversion through the inverse Primakoff effect in a few GHz frequency range in a very high magnetic field and at an ultra low temperature. The constructed DAQ system utilizes a Field Programmable Gate Array (FPGA) for data processing and Fast Fourier Transformation. This design along with a custom Ethernet packet designed for real-time data transfer enables 100% DAQ efficiency, which is the key feature compared with a commercial spectrum analyzer. This DAQ system is optimally designed for RF signal detection in the axion experiment, with 100 Hz frequency resolution and 500 kHz analysis window. The noise level of the DAQ system averaged over 100,000 measurements is around -111.7 dBm. From a pseudo-data analysis, an improvement of the signal-to-noise ratio due to repeating and averaging the measurements using this real-time DAQ system was confirmed.
△ Less
Submitted 6 November, 2021;
originally announced November 2021.
-
Fast DAQ system with image rejection for axion dark matter searches
Authors:
S. Ahn,
M. J. Lee,
A. K. Yi,
B. Yeo,
B. R. Ko,
Y. K. Semertzidis
Abstract:
A fast data acquisition (DAQ) system for axion dark matter searches utilizing a microwave resonant cavity, also known as axion haloscope searches, has been developed with a two-channel digitizer that can sample 16-bit amplitudes at rates up to 180 MSamples/s. First, we realized a practical DAQ efficiency of greater than 99% for a single DAQ channel, where the DAQ process includes the online fast F…
▽ More
A fast data acquisition (DAQ) system for axion dark matter searches utilizing a microwave resonant cavity, also known as axion haloscope searches, has been developed with a two-channel digitizer that can sample 16-bit amplitudes at rates up to 180 MSamples/s. First, we realized a practical DAQ efficiency of greater than 99% for a single DAQ channel, where the DAQ process includes the online fast Fourier transforms (FFTs). Using an IQ mixer and two parallel DAQ channels, we then also implemented a software-based image rejection without losing the DAQ efficiency. This work extends our continuing effort to improve the figure of merit in axion haloscope searches, the scanning rate.
△ Less
Submitted 17 April, 2022; v1 submitted 16 September, 2021;
originally announced September 2021.
-
Metasurface Holography over 90% Efficiency in the Visible via Nanoparticle-Embedded-Resin Printing
Authors:
Joohoon Kim,
Dong Kyo Oh,
Hongyoon Kim,
Gwanho Yoon,
Chunghwan Jung,
Jae Kyung Kim,
Trevon Badloe,
Seokwoo Kim,
Younghwan Yang,
Jihae Lee,
Byoungsu Ko,
Jong G. Ok,
Junsuk Rho
Abstract:
Metasurface holography, the reconstruction of holographic images by modulating the spatial amplitude and phase of light using metasurfaces, has emerged as a next-generation display technology. However, conventional fabrication techniques used to realize metaholograms are limited by their small patterning areas, high manufacturing costs, and low throughput, which hinder their practical use. Herein,…
▽ More
Metasurface holography, the reconstruction of holographic images by modulating the spatial amplitude and phase of light using metasurfaces, has emerged as a next-generation display technology. However, conventional fabrication techniques used to realize metaholograms are limited by their small patterning areas, high manufacturing costs, and low throughput, which hinder their practical use. Herein, we demonstrate a high efficiency hologram using a one-step nanomanufacturing method with a titanium dioxide nanoparticle-embedded-resin, allowing for high-throughput and low-cost fabrication. At a single wavelength, a record high 96.4% theoretical efficiency is demonstrated with an experimentally measured conversion efficiency of 90.6% and zero-order diffraction of 7.3% producing an ultrahigh-efficiency, twin-image free hologram, that can even be directly observed under ambient light conditions. Moreover, we design a broadband meta-atom with an average efficiency of 76.0% and experimentally demonstrate a metahologram with an average efficiency of 62.4% at visible wavelengths from 450 to 650 nm.
△ Less
Submitted 2 September, 2021;
originally announced September 2021.
-
Performance of a Triple-GEM Demonstrator in $pp$ Collisions at the CMS Detector
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstr…
▽ More
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstrator GEM detectors were installed in CMS during 2017 to gain operational experience and perform a preliminary investigation of detector performance. We present the results of triple-GEM detector performance studies performed in situ during normal CMS and LHC operations in 2018. The distribution of cluster size and the efficiency to reconstruct high $p_T$ muons in proton--proton collisions are presented as well as the measurement of the environmental background rate to produce hits in the GEM detector.
△ Less
Submitted 22 September, 2021; v1 submitted 20 July, 2021;
originally announced July 2021.
-
Modeling the triple-GEM detector response to background particles for the CMS Experiment
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
I. Azhgirey,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (164 additional authors not shown)
Abstract:
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The…
▽ More
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The simulation framework uses a combination of the FLUKA and Geant4 packages to obtain the hit rate. FLUKA provides the radiation environment around the GE1/1 chambers, which is comprised of the particle flux with momentum direction and energy spectra ranging from $10^{-11}$ to $10^{4}$ MeV for neutrons, $10^{-3}$ to $10^{4}$ MeV for $γ$'s, $10^{-2}$ to $10^{4}$ MeV for $e^{\pm}$, and $10^{-1}$ to $10^{4}$ MeV for charged hadrons. Geant4 provides an estimate of detector response (sensitivity) based on an accurate description of detector geometry, material composition and interaction of particles with the various detector layers. The MC simulated hit rate is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties of 10-14.5%. This simulation framework can be used to obtain a reliable estimate of background rates expected at the High Luminosity LHC.
△ Less
Submitted 8 July, 2021;
originally announced July 2021.
-
Isogeometric Configuration Design Optimization of Three-dimensional Curved Beam Structures for Maximal Fundamental Frequency
Authors:
Myung-Jin Choi,
Jae-Hyun Kim,
Bonyong Koo,
Seonho Cho
Abstract:
This paper presents a configuration design optimization method for three-dimensional curved beam built-up structures having maximized fundamental eigenfrequency. We develop the method of computation of design velocity field and optimal design of beam structures constrained on a curved surface, where both designs of the embedded beams and the curved surface are simultaneously varied during the opti…
▽ More
This paper presents a configuration design optimization method for three-dimensional curved beam built-up structures having maximized fundamental eigenfrequency. We develop the method of computation of design velocity field and optimal design of beam structures constrained on a curved surface, where both designs of the embedded beams and the curved surface are simultaneously varied during the optimal design process. A shear-deformable beam model is used in the response analyses of structural vibrations within an isogeometric framework using the NURBS basis functions. An analytical design sensitivity expression of repeated eigenvalues is derived. The developed method is demonstrated through several illustrative examples.
△ Less
Submitted 23 January, 2021;
originally announced January 2021.
-
CAPP-8TB: Axion Dark Matter Search Experiment around 6.7 $μ$eV
Authors:
J. Choi,
S. Ahn,
B. R. Ko,
S. Lee,
Y. K. Semertzidis
Abstract:
CAPP-8TB is an axion dark matter search experiment dedicated to an axion mass search near 6.7 $μ$eV. The experiment uses a microwave resonant cavity under a strong magnetic field of 8 T produced by a superconducting solenoid magnet in a dilution refrigerator. We describe the experimental configuration used to search for a mass range of 6.62 to 6.82 $μ$eV in the first phase of the experiment. We al…
▽ More
CAPP-8TB is an axion dark matter search experiment dedicated to an axion mass search near 6.7 $μ$eV. The experiment uses a microwave resonant cavity under a strong magnetic field of 8 T produced by a superconducting solenoid magnet in a dilution refrigerator. We describe the experimental configuration used to search for a mass range of 6.62 to 6.82 $μ$eV in the first phase of the experiment. We also discuss the next phase of the experiment and its prospects.
△ Less
Submitted 14 July, 2020;
originally announced July 2020.
-
Axion Dark Matter Research with IBS/CAPP
Authors:
Yannis K. Semertzidis,
Jihn E. Kim,
SungWoo Youn,
Jihoon Choi,
Woohyun Chung,
Selcuk Haciomeroglu,
Dongmin Kim,
Jingeun Kim,
ByeongRok Ko,
Ohjoon Kwon,
Andrei Matlashov,
Lino Miceli,
Hiroaki Natori,
Seongtae Park,
MyeongJae Lee,
Soohyung Lee,
Elena Sala,
Yunchang Shin,
Taehyeon Seong,
Sergey Uchaykin,
Danho Ahn,
Saebyeok Ahn,
Seung Pyo Chang,
Wheeyeon Cheong,
Hoyong Jeong
, et al. (12 additional authors not shown)
Abstract:
The axion, a consequence of the PQ mechanism, has been considered as the most elegant solution to the strong-CP problem and a compelling candidate for cold dark matter. The Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) was established on 16 October 2013 with a main objective to launch state of the art axion experiments in South Korea. Relying on th…
▽ More
The axion, a consequence of the PQ mechanism, has been considered as the most elegant solution to the strong-CP problem and a compelling candidate for cold dark matter. The Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) was established on 16 October 2013 with a main objective to launch state of the art axion experiments in South Korea. Relying on the haloscope technique, our strategy is to run several experiments in parallel to explore a wide range of axion masses with sensitivities better than the QCD axion models. We utilize not only the advanced technologies, such as high-field large-volume superconducting (SC) magnets, ultra low temperature dilution refrigerators, and nearly quantum-limited noise amplifiers, but also some unique features solely developed at the Center, including high-quality SC resonant cavities surviving high magnetic fields and efficient cavity geometries to reach high-frequency regions. Our goal is to probe axion dark matter in the frequency range of 1-10 GHz in the first phase and then ultimately up to 25 GHz, even in a scenario where axions constitute only 10% of the local dark matter halo. In this report, the current status and future prospects of the experiments and R&D activities at IBS/CAPP are described.
△ Less
Submitted 25 October, 2019;
originally announced October 2019.
-
CAPP-8TB: Search for Axion Dark Matter in a Mass Range of 6.62 to 7.04 $μ$eV
Authors:
Soohyung Lee,
Saebyeok Ahn,
Jihoon Choi,
Byeong Rok Ko,
Yannis K. Semertzidis
Abstract:
The axion is a hypothetical particle proposed to solve the strong $CP$ problem, and also a candidate for dark matter. This non-relativistic particle in the galactic halo can be converted into a photon under a strong magnetic field and detected with a microwave resonant cavity. Relying on this detection method, many experiments have excluded some mass regions with certain sensitivities in terms of…
▽ More
The axion is a hypothetical particle proposed to solve the strong $CP$ problem, and also a candidate for dark matter. This non-relativistic particle in the galactic halo can be converted into a photon under a strong magnetic field and detected with a microwave resonant cavity. Relying on this detection method, many experiments have excluded some mass regions with certain sensitivities in terms of axion-photon coupling ($g_{aγγ}$) for decades, but no axion dark matter has been discovered to date. CAPP-8TB is an axion haloscope experiment at IBS/CAPP designed to search for the axion in a mass range of 6.62 to 7.04 $μ$eV. The experiment aims for the most sensitive axion dark matter search in this particular mass range with its first-phase sensitivity reaching the QCD axion band. In this presentation, we discuss the overview of the experiment, and present the first result. We also discuss an upgrade of the experiment to achieve higher sensitivity.
△ Less
Submitted 14 October, 2019; v1 submitted 30 September, 2019;
originally announced October 2019.
-
Kibble-Zurek universality in a strongly interacting Fermi superfluid
Authors:
Bumsuk Ko,
Jee Woo Park,
Y. Shin
Abstract:
Near a continuous phase transition, systems with different microscopic origins display universal dynamics if their underlying symmetries are compatible. In a thermally quenched system, the Kibble-Zurek mechanism for the creation of topological defects unveils this universality through a characteristic power-law exponent, which captures the dependence of the defect density on the quench rate. Here,…
▽ More
Near a continuous phase transition, systems with different microscopic origins display universal dynamics if their underlying symmetries are compatible. In a thermally quenched system, the Kibble-Zurek mechanism for the creation of topological defects unveils this universality through a characteristic power-law exponent, which captures the dependence of the defect density on the quench rate. Here, we report the observation of the Kibble-Zurek universality in a strongly interacting Fermi superfluid. As the system's microscopic description is tuned from bosonic to fermionic, the quench formation of vortices reveals a constant scaling exponent arising from the $U(1)$ gauge symmetry of the system. For rapid quenches, destructive vortex collisions lead to the saturation of their densities, whose values can be universally scaled by the interaction-dependent area of the vortex cores.
△ Less
Submitted 19 February, 2019;
originally announced February 2019.
-
Three dimensional fast tracker for central drift chamber based level 1 trigger system in the Belle II experiment
Authors:
E. Won,
J. B. Kim,
B. R. Ko
Abstract:
The Belle II detector at the SuperKEKB accelerator has a level 1 trigger implemented in field-programmable gate arrays. Due to the high luminosity of the beam, a trigger that effectively rejects beam induced background is required. A three dimensional tracking algorithm for the level 1 trigger that uses the Belle II central drift chamber detector response is being developed to reduce the recorded…
▽ More
The Belle II detector at the SuperKEKB accelerator has a level 1 trigger implemented in field-programmable gate arrays. Due to the high luminosity of the beam, a trigger that effectively rejects beam induced background is required. A three dimensional tracking algorithm for the level 1 trigger that uses the Belle II central drift chamber detector response is being developed to reduce the recorded beam background while having a high efficiency for physics of interest. In this paper, we describe the three dimensional track trigger that finds and fits track parameters which we developed.
△ Less
Submitted 7 November, 2017;
originally announced November 2017.
-
First axion dark matter search with toroidal geometry
Authors:
J. Choi,
H. Themann,
M. J. Lee,
B. R. Ko,
Y. K. Semertzidis
Abstract:
We firstly report an axion haloscope search with toroidal geometry. In this pioneering search, we exclude the axion-photon coupling $g_{aγγ}$ down to about $5\times10^{-8}$ GeV$^{-1}$ over the axion mass range from 24.7 to 29.1 $μ$eV at a 95\% confidence level. The prospects for axion dark matter searches with larger scale toroidal geometry are also considered.
We firstly report an axion haloscope search with toroidal geometry. In this pioneering search, we exclude the axion-photon coupling $g_{aγγ}$ down to about $5\times10^{-8}$ GeV$^{-1}$ over the axion mass range from 24.7 to 29.1 $μ$eV at a 95\% confidence level. The prospects for axion dark matter searches with larger scale toroidal geometry are also considered.
△ Less
Submitted 5 September, 2017; v1 submitted 25 April, 2017;
originally announced April 2017.
-
Observation of vortex-antivortex pairing in decaying 2D turbulence of a superfluid gas
Authors:
Sang Won Seo,
Bumsuk Ko,
Joon Hyun Kim,
Yong-il Shin
Abstract:
In a two-dimensional (2D) classical fluid, a large-scale flow structure emerges out of turbulence, which is known as the inverse energy cascade where energy flows from small to large length scales. An interesting question is whether this phenomenon can occur in a superfluid, which is inviscid and irrotational by nature. Atomic Bose-Einstein condensates (BECs) of highly oblate geometry provide an e…
▽ More
In a two-dimensional (2D) classical fluid, a large-scale flow structure emerges out of turbulence, which is known as the inverse energy cascade where energy flows from small to large length scales. An interesting question is whether this phenomenon can occur in a superfluid, which is inviscid and irrotational by nature. Atomic Bose-Einstein condensates (BECs) of highly oblate geometry provide an experimental venue for studying 2D superfluid turbulence, but their full investigation has been hindered due to a lack of the circulation sign information of individual quantum vortices in a turbulent sample. Here, we demonstrate a vortex sign detection method by using Bragg scattering, and we investigate decaying turbulence in a highly oblate BEC at low temperatures, with our lowest being $\sim 0.5 T_c$, where $T_c$ is the superfluid critical temperature. We observe that weak spatial pairing between vortices and antivortices develops in the turbulent BEC, which corresponds to the vortex-dipole gas regime predicted for high dissipation. Our results provide a direct quantitative marker for the survey of various 2D turbulence regimes in the BEC system.
△ Less
Submitted 10 May, 2017; v1 submitted 20 October, 2016;
originally announced October 2016.
-
Axion Haloscopes with Toroidal Geometry at CAPP/IBS
Authors:
B. R. Ko
Abstract:
The present state of the art axion haloscope employs a cylindrical resonant cavity in a solenoidal field. We, the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) in Korea, are also pursuing halo axion discovery using this cylindrical geometry. However, the presence of end caps of cavities increases challenges as we explore higher frequency regions fo…
▽ More
The present state of the art axion haloscope employs a cylindrical resonant cavity in a solenoidal field. We, the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) in Korea, are also pursuing halo axion discovery using this cylindrical geometry. However, the presence of end caps of cavities increases challenges as we explore higher frequency regions for the axion at above 2 GHz. To overcome these challenges we exploit a toroidal design of cavity and magnetic field. A toroidal geometry offers several advantages, two of which are a larger volume for a given space and greatly reduced fringe fields which interfere with our preamps, in particular the planned quantum-based devices. We introduce the concept of toroidal axion haloscopes and present ongoing research activities and plans at CAPP/IBS.
△ Less
Submitted 13 September, 2016;
originally announced September 2016.
-
Belle II Technical Design Report
Authors:
T. Abe,
I. Adachi,
K. Adamczyk,
S. Ahn,
H. Aihara,
K. Akai,
M. Aloi,
L. Andricek,
K. Aoki,
Y. Arai,
A. Arefiev,
K. Arinstein,
Y. Arita,
D. M. Asner,
V. Aulchenko,
T. Aushev,
T. Aziz,
A. M. Bakich,
V. Balagura,
Y. Ban,
E. Barberio,
T. Barvich,
K. Belous,
T. Bergauer,
V. Bhardwaj
, et al. (387 additional authors not shown)
Abstract:
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr…
▽ More
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been proposed. A new international collaboration Belle-II, is being formed. The Technical Design Report presents physics motivation, basic methods of the accelerator upgrade, as well as key improvements of the detector.
△ Less
Submitted 1 November, 2010;
originally announced November 2010.