Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–13 of 13 results for author: Kubarovsky, V

Searching in archive physics. Search in all archives.
.
  1. arXiv:2209.00496  [pdf, other

    physics.ins-det nucl-ex

    CORE -- a COmpact detectoR for the EIC

    Authors: CORE Collaboration, R. Alarcon, M. Baker, V. Baturin, P. Brindza, S. Bueltmann, M. Bukhari, R. Capobianco, E. Christy, S. Diehl, M. Dugger, R. Dupré, R. Dzhygadlo, K. Flood, K. Gnanvo, L. Guo, T. Hayward, M. Hattawy, M. Hoballah, M. Hohlmann, C. E. Hyde, Y. Ilieva, W. W. Jacobs, K. Joo, G. Kalicy , et al. (34 additional authors not shown)

    Abstract: The COmpact detectoR for the Eic (CORE) Proposal was submitted to the EIC "Call for Collaboration Proposals for Detectors". CORE comprehensively covers the physics scope of the EIC Community White Paper and the National Academies of Science 2018 report. The design exploits advances in detector precision and granularity to minimize size. The central detector includes a 3Tesla, 2.5m solenoid. Tracki… ▽ More

    Submitted 1 September, 2022; originally announced September 2022.

    Comments: Contact authors: C.E. Hyde, chyde@odu.edu and P. Nadel-Turonski, turonski@jlab.org

  2. arXiv:2202.07776  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Characterization of Multianode Photomultiplier Tubes for use in the CLAS12 RICH Detector

    Authors: Pavel Degtiarenko, Andrey Kim, Valery Kubarovsky, Ben Raydo, Andrew Smith, Fatiha Benmokhtar

    Abstract: We present results of the detailed study of several hundred Hamamatsu H12700 Multianode Photomultiplier Tubes (MaPMTs), characterizing their response to the Cherenkov light photons in the second Ring Imaging Cherenkov detector, a part of the CLAS12 upgrade at Jefferson Lab. The total number of pixels studied was 25536. The single photoelectron spectra were measured for each pixel at different high… ▽ More

    Submitted 6 September, 2022; v1 submitted 15 February, 2022; originally announced February 2022.

  3. arXiv:2108.13276  [pdf, other

    nucl-ex physics.ins-det

    A Direct Detection Search for Hidden Sector New Particles in the 3-60 MeV Mass Range

    Authors: A. Ahmidouch, S. Davis, A. Gasparian, T. J. Hague, S. Mtingwa, R. Pedroni, C. Ayerbe-Gayoso, H. Bhatt, B. Devkota, J. Dunne, D. Dutta, L. El Fassi, A. Karki, P. Mohanmurthy, C. Peng, S. Ali, X. Bai, J. Boyd, B. Dharmasena, V. Gamage, K. Gnanvo, S. Jeffas, S. Jian, N. Liyanage, H. Nguyen , et al. (36 additional authors not shown)

    Abstract: In our quest to understand the nature of dark matter and discover its non-gravitational interactions with ordinary matter, we propose an experiment using a \pbo ~calorimeter to search for or set new limits on the production rate of i) hidden sector particles in the $3 - 60$ MeV mass range via their $e^+e^-$ decay (or $γγ$ decay with limited tracking), and ii) the hypothetical X17 particle, claimed… ▽ More

    Submitted 4 August, 2022; v1 submitted 30 August, 2021; originally announced August 2021.

    Comments: 47 pages, 44 Figures. JLab PAC50 Proposal

    Report number: PR12-21-003

  4. arXiv:1910.03532  [pdf, other

    physics.ins-det hep-ex

    Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab -- 2018 update to PR12-16-001

    Authors: M. Battaglieri, A. Bersani, G. Bracco, B. Caiffi, A. Celentano, R. De Vita, L. Marsicano, P. Musico, F. Panza, M. Ripani, E. Santopinto, M. Taiuti, V. Bellini, M. Bondi', P. Castorina, M. De Napoli, A. Italiano, V. Kuznetzov, E. Leonora, F. Mammoliti, N. Randazzo, L. Re, G. Russo, M. Russo, A. Shahinyan , et al. (100 additional authors not shown)

    Abstract: This document complements and completes what was submitted last year to PAC45 as an update to the proposal PR12-16-001 "Dark matter search in a Beam-Dump eXperiment (BDX)" at Jefferson Lab submitted to JLab-PAC44 in 2016. Following the suggestions contained in the PAC45 report, in coordination with the lab, we ran a test to assess the beam-related backgrounds and validate the simulation framework… ▽ More

    Submitted 8 October, 2019; originally announced October 2019.

    Report number: PR12-16-001

  5. arXiv:1712.01518  [pdf, other

    physics.ins-det hep-ex

    Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab: an update on PR12-16-001

    Authors: M. Battaglieri, A. Bersani, G. Bracco, B. Caiffi, A. Celentano, R. De Vita, L. Marsicano, P. Musico, M. Osipenko, F. Panza, M. Ripani, E. Santopinto, M. Taiuti, V. Bellini, M. Bondi', P. Castorina, M. De Napoli, A. Italiano, V. Kuznetzov, E. Leonora, F. Mammoliti, N. Randazzo, L. Re, G. Russo, M. Russo , et al. (101 additional authors not shown)

    Abstract: This document is an update to the proposal PR12-16-001 Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab submitted to JLab-PAC44 in 2016 reporting progress in addressing questions raised regarding the beam-on backgrounds. The concerns are addressed by adopting a new simulation tool, FLUKA, and planning measurements of muon fluxes from the dump with its existing shielding around t… ▽ More

    Submitted 8 January, 2018; v1 submitted 5 December, 2017; originally announced December 2017.

    Comments: Document submitted to JLab PAC 45

    Report number: FERMILAB-TM-2667-PPD

  6. arXiv:1711.09089  [pdf, other

    physics.ins-det nucl-ex

    Design and Performance of the Spin Asymmetries of the Nucleon Experiment

    Authors: J. D. Maxwell, W. R. Armstrong, S. Choi, M. K. Jones, H. Kang, A. Liyanage, Z. -E. Meziani, J. Mulholland, L. Ndukum, O. A. Rondon, A. Ahmidouch, I. Albayrak, A. Asaturyan, O. Ates, H. Baghdasaryan, W. Boeglin, P. Bosted, E. Brash, J. Brock, C. Butuceanu, M. Bychkov, C. Carlin, P. Carter, C. Chen, J. -P. Chen , et al. (80 additional authors not shown)

    Abstract: The Spin Asymmetries of the Nucleon Experiment (SANE) performed inclusive, double-polarized electron scattering measurements of the proton at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. A novel detector array observed scattered electrons of four-momentum transfer $2.5 < Q^2< 6.5$ GeV$^2$ and Bjorken scaling $0.3<x<0.8$ from initial beam energies of 4.7 and 5.9 GeV. Employin… ▽ More

    Submitted 21 December, 2017; v1 submitted 22 November, 2017; originally announced November 2017.

    Report number: JLAB-PHY-17-2595

  7. arXiv:1610.04319  [pdf, other

    physics.ins-det hep-ex nucl-ex

    The HPS electromagnetic calorimeter

    Authors: Ilaria Balossino, Nathan Baltzell, Marco Battaglieri, Mariangela Bondi, Emma Buchanan, Daniela Calvo, Andrea Celentano, Gabriel Charles, Luca Colaneri, Annalisa D'Angelo, Marzio De Napoli, Raffaella De Vita, Raphael Dupre, Hovanes Egiyan, Mathieu Ehrhart, Alessandra Filippi, Michel Garcon, Nerses Gevorgyan, Francois-Xavier Girod, Michel Guidal, Maurik Holtrop, Volodymyr Iurasov, Valery Kubarovsky, Kenneth Livingston, Kyle McCarty , et al. (14 additional authors not shown)

    Abstract: The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called "heavy photon." Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HP… ▽ More

    Submitted 2 February, 2017; v1 submitted 14 October, 2016; originally announced October 2016.

    Comments: 34 pages, 25 figures

  8. arXiv:1509.02818  [pdf, ps, other

    physics.ins-det nucl-ex

    Test of the CLAS12 RICH large scale prototype in the direct proximity focusing configuration

    Authors: N. Baltzell, L. Barion, F. Benmokhtar, W. Brooks, E. Cisbani, M. Contalbrigo, A. El Alaoui, K. Hafidi, M. Hoek, V. Kubarovsky, L. Lagamba, V. Lucherini, R. Malaguti, M. Mirazita, R. A. Montgomery, A. Movsisyan, P. Musico, A. Orlandi, D. Orecchini, L. L. Pappalardo, R. Perrino, J. Phillips, S. Pisano, P. Rossi, S. Squerzanti , et al. (3 additional authors not shown)

    Abstract: A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c up to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Laboratory. The adopted solution foresees a novel hybrid optics design based on aerogel radiator, composite mirrors and high-pack… ▽ More

    Submitted 1 February, 2016; v1 submitted 9 September, 2015; originally announced September 2015.

    Comments: 15 pages, 23 figures, to appear on EPJA

    Journal ref: Eur. Phys. J. A (2016) 52: 23

  9. arXiv:1406.6115  [pdf, other

    physics.ins-det hep-ex

    The Heavy Photon Search Test Detector

    Authors: Marco Battaglieri, Sergey Boyarinov, Stephen Bueltmann, Volker Burkert, Andrea Celentano, Gabriel Charles, William Cooper, Chris Cuevas, Natalia Dashyan, Raffaella DeVita, Camille Desnault, Alexandre Deur, Hovanes Egiyan, Latifa Elouadrhiri, Rouven Essig, Vitaliy Fadeyev, Clive Field, Arne Freyberger, Yuri Gershtein, Nerses Gevorgyan, Francois-Xavier Girod, Norman Graf, Mathew Graham, Keith Griffioen, Alexander Grillo , et al. (39 additional authors not shown)

    Abstract: The Heavy Photon Search (HPS), an experiment to search for a hidden sector photon in fixed target electroproduction, is preparing for installation at the Thomas Jefferson National Accelerator Facility (JLab) in the Fall of 2014. As the first stage of this project, the HPS Test Run apparatus was constructed and operated in 2012 to demonstrate the experiment's technical feasibility and to confirm th… ▽ More

    Submitted 4 June, 2015; v1 submitted 23 June, 2014; originally announced June 2014.

    Comments: Revised version to match published version, 16 pages, 18 figures, published in Nuclear Instruments and Methods in Physics Research Section A, editor: Per Hansson Adrian

    Report number: SLAC-PUB-15999

    Journal ref: Nuclear Inst. and Methods in Physics Research, A Volume 777, 21 March 2015, Pages 91-101, ISSN 0168-9002

  10. arXiv:1406.3028  [pdf, other

    physics.ins-det astro-ph.IM hep-ex hep-ph nucl-ex

    Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab

    Authors: BDX Collaboration, M. Battaglieri, A. Celentano, R. De Vita, E. Izaguirre, G. Krnjaic, E. Smith, S. Stepanyan, A. Bersani, E. Fanchini, S. Fegan, P. Musico, M. Osipenko, M. Ripani, E. Santopinto, M. Taiuti, P. Schuster, N. Toro, M. Dalton, A. Freyberger, F. -X. Girod, V. Kubarovsky, M. Ungaro, G. De Cataldo, R. De Leo , et al. (61 additional authors not shown)

    Abstract: MeV-GeV dark matter (DM) is theoretically well motivated but remarkably unexplored. This Letter of Intent presents the MeV-GeV DM discovery potential for a 1 m$^3$ segmented plastic scintillator detector placed downstream of the beam-dump at one of the high intensity JLab experimental Halls, receiving up to 10$^{22}$ electrons-on-target (EOT) in a one-year period. This experiment (Beam-Dump eXperi… ▽ More

    Submitted 11 June, 2014; originally announced June 2014.

    Comments: 28 pages, 17 figures, submitted to JLab PAC 42

  11. arXiv:physics/0504035  [pdf, ps, other

    physics.ins-det hep-ex

    The SPHINX spectrometer

    Authors: SPHINX Collaboration, Yu. Antipov, A. Artamonov, V. Batarin, V. Bezzubov, O. Eroshin, S. Golovkin, Yu. Gorin, V. Govorun, A. Isaev, V. Kolganov, A. Konstantinov, A. Kozhevnikov, V. Kubarovsky, V. Kurshetsov, A. Kushnirenko, L. Landsberg, V. Leontiev, G. Lomkatsi, M. Medinskiy, V. Medovikov, V. Molchanov, V. Morozova, V. Mukhin, A. Nilov , et al. (13 additional authors not shown)

    Abstract: The paper describes the SPHINX facility which includes a wide-aperture magnetic spectrometer with scintillation counters and hodoscopes, proportional chambers and drift tubes, multichannel electromagnetic and hadron calorimeters, a guard system, a RICH velocity spectrometer and a hodoscopical threshold Cherenkov detector for the identification of charged secondary particles. The SPHINX spectrome… ▽ More

    Submitted 26 December, 2005; v1 submitted 5 April, 2005; originally announced April 2005.

    Comments: 18 pages, 8 figures; minor fixes in: acknowledgements, fig.quality

    Report number: IHEP-04-53

  12. arXiv:hep-ex/0208046  [pdf, ps, other

    hep-ex physics.ins-det

    SELEX RICH Performance and Physics Results

    Authors: J. Engelfried, I. S Filimonov, J. Kilmer, A. P. Kozhevnikov, V. P. Kubarovsky, V. V Molchanov, A. V. Nemitkin, E. Ramberg, V. I. Rud, L. Stutte

    Abstract: SELEX took data in the 1996/7 Fixed Target Run at Fermilab. The excellent performance parameters of the SELEX RICH Detector had direct influence on the quality of the obtained physics results.

    Submitted 28 August, 2002; originally announced August 2002.

    Comments: Contributed talk at the Fourth Workshop on RICH Detectors, June 5-10, 2002, Pylos, Greece. Accepted for publication in NIMA

    Report number: UASLP-IF-02-007, FERMILAB-Conf-02/181-E

    Journal ref: Nucl.Instrum.Meth.A502:285-288,2003

  13. arXiv:hep-ex/9811001  [pdf, ps, other

    hep-ex physics.ins-det

    The SELEX Phototube RICH Detector

    Authors: J. Engelfried, I. Filimonov, J. Kilmer, A. Kozhevnikov, V. Kubarovsky, V. Molchanov, A. Nemitkin, E. Ramberg, V. Rud, L. Stutte

    Abstract: In this article, construction, operation, and performance of the RICH detector of Fermilab experiment 781 (SELEX) are described. The detector utilizes a matrix of 2848 phototubes for the photocathode to detect Cherenkov photons generated in a 10m Neon radiator. For the central region an N0 of 104/cm, corresponding to 13.6 hits on a beta=1 ring, was obtained. The ring radius resolution measured i… ▽ More

    Submitted 30 October, 1998; originally announced November 1998.

    Comments: 25 pages with 14 figures included. Submitted to Nuclear Instruments and Methods A

    Report number: FERMILAB-PUB-98/299-E

    Journal ref: Nucl.Instrum.Meth. A431 (1999) 53-69