-
Thermal Barrier Coatings in burner rig experiment analyzed through LAser Shock for DAmage Monitoring (LASDAM) method
Authors:
Lara Mahfouz,
Vincent Maurel,
Vincent Guipont,
Basile Marchand,
Rami El Hourany,
Florent Coudon,
Daniel E. Mack,
Robert Vaßen
Abstract:
This study investigates failure mechanisms in a typical thermal barrier coating (TBC) system comprising an EB-PVD columnar top coat, an aluminide bond coat, and a Ni-based single crystal superalloy substrate, simulating gas turbine operating conditions using a burner rig. TBC degradation, initiated by interfacial defects from the LASAT method, was studied during thermal gradient cycling under fast…
▽ More
This study investigates failure mechanisms in a typical thermal barrier coating (TBC) system comprising an EB-PVD columnar top coat, an aluminide bond coat, and a Ni-based single crystal superalloy substrate, simulating gas turbine operating conditions using a burner rig. TBC degradation, initiated by interfacial defects from the LASAT method, was studied during thermal gradient cycling under fast and slow cooling. In-situ optical and infrared imaging, along with ex-situ SEM cross-sectional analysis, monitored failure mechanisms. The Laser Shock for Damage Monitoring (LASDAM) technique provided insights into gradient and cooling rate impacts on columnar TBC damage. Results showed significant effects of cooling rate on delamination and localized failure at blister sites, with LASDAM revealing significant overheating at damage sites. Analysis included full-field temperature and damage assessment, emphasizing blister-driven delamination under severe thermal gradients. Discussion focused on elastic stored energy effects, noting that fast cooling induced transient conditions where reversed temperature gradients increased damage, limiting TBC lifespan
△ Less
Submitted 29 April, 2024; v1 submitted 9 April, 2024;
originally announced April 2024.
-
A tenuous, collisional atmosphere on Callisto
Authors:
Shane Carberry Mogan,
Orenthal Tucker,
Robert Johnson,
Audrey Vorburger,
Andre Galli,
Benoit Marchand,
Angelo Tafuni,
Sunil Kumar,
Iskender Sahin,
Katepalli Sreenivasan
Abstract:
A simulation tool which utilizes parallel processing is developed to describe molecular kinetics in 2D, single-and multi-component atmospheres on Callisto. This expands on our previous study on the role of collisions in 1D atmospheres on Callisto composed of radiolytic products (Carberry Mogan et al., 2020) by implementing a temperature gradient from noon to midnight across Callisto's surface and…
▽ More
A simulation tool which utilizes parallel processing is developed to describe molecular kinetics in 2D, single-and multi-component atmospheres on Callisto. This expands on our previous study on the role of collisions in 1D atmospheres on Callisto composed of radiolytic products (Carberry Mogan et al., 2020) by implementing a temperature gradient from noon to midnight across Callisto's surface and introducing sublimated water vapor. We compare single-species, ballistic and collisional O2, H2 and H2O atmospheres, as well as an O2+H2O atmosphere to 3-species atmospheres which contain H2 in varying amounts. Because the H2O vapor pressure is extremely sensitive to the surface temperatures, the density drops several order of magnitude with increasing distance from the subsolar point, and the flow transitions from collisional to ballistic accordingly. In an O2+H2O atmosphere the local temperatures are determined by H2O near the subsolar point and transition with increasing distance from the subsolar point to being determined by O2 When radiolytically produced H2 is not negligible in O2+H2O+H2 atmospheres, this much lighter molecule, with a scale height roughly an order of magnitude larger than that for the heavier species, can cool the local temperatures via collisions. In addition, if the H2 component is dense enough, particles originating on the day-side and precipitating into the night-side atmosphere deposit energy via collisions, which in turn heats the local atmosphere relative to the surface temperature. Finally, we discuss the potential implications of this study on the presence of H2 in Callisto's atmosphere and how the simulated densities correlate with expected detection thresholds at flyby altitudes of the proposed JUpiter ICy moons Explorer (JUICE) spacecraft.
△ Less
Submitted 26 July, 2021;
originally announced July 2021.
-
Characterization and performances of a monitoring ionization chamber dedicated to IBA-universal irradiation head for Pencil Beam Scanning
Authors:
C. Courtois,
G. Boissonnat,
C. Brusasco,
J. Colin,
D. Cussol,
J. M. Fontbonne,
B. Marchand,
T. Mertens,
S. De Neuter,
J. Perronnel
Abstract:
Every radiotherapy center has to be equipped with real-time beam monitoring devices. In 2008, the medical application group from the Laboratory of Corpuscular Physics (LPC Caen) developed an Ionization Chamber in collaboration with the company IBA (Ion Beam Applications). This monitoring device called IC2/3 was developed to be used in IBAs universal irradiation head for Pencil Beam Scanning (PBS).…
▽ More
Every radiotherapy center has to be equipped with real-time beam monitoring devices. In 2008, the medical application group from the Laboratory of Corpuscular Physics (LPC Caen) developed an Ionization Chamber in collaboration with the company IBA (Ion Beam Applications). This monitoring device called IC2/3 was developed to be used in IBAs universal irradiation head for Pencil Beam Scanning (PBS). The objectives presented in this article are to characterize the IC2/3 monitor in the energy and ux ranges used in protontherapy. The equipment has been tested with an IBAs cyclotronable to deliver proton beams from 70 to 230 MeV. This beam monitoring device has been validated and is now installed at the Westdeutsches Protonentherapiezentrum Essen protontherapy center (WPE, Germany). The results obtained in both terms of spatial resolution and dose measurements are at least equal to the initials speci cations needed for PBS purposes. The detector measures the dose with a relative precision better than 1% in the range 0.5 Gy/min to 8 Gy/min while the spatial resolution is higher than 250 m. The technology has been patented and ve IC2/3 chambers were delivered to IBA. Nowadays, IBA produces the IC2/3 beam monitoring device as part of its Proteus 235 product
△ Less
Submitted 12 September, 2013; v1 submitted 28 June, 2013;
originally announced June 2013.