Euclid preparation. LensMC, weak lensing cosmic shear measurement with forward modelling and Markov Chain Monte Carlo sampling
Authors:
Euclid Collaboration,
G. Congedo,
L. Miller,
A. N. Taylor,
N. Cross,
C. A. J. Duncan,
T. Kitching,
N. Martinet,
S. Matthew,
T. Schrabback,
M. Tewes,
N. Welikala,
N. Aghanim,
A. Amara,
S. Andreon,
N. Auricchio,
M. Baldi,
S. Bardelli,
R. Bender,
C. Bodendorf,
D. Bonino,
E. Branchini,
M. Brescia,
J. Brinchmann,
S. Camera
, et al. (217 additional authors not shown)
Abstract:
LensMC is a weak lensing shear measurement method developed for Euclid and Stage-IV surveys. It is based on forward modelling to deal with convolution by a point spread function with comparable size to many galaxies; sampling the posterior distribution of galaxy parameters via Markov Chain Monte Carlo; and marginalisation over nuisance parameters for each of the 1.5 billion galaxies observed by Eu…
▽ More
LensMC is a weak lensing shear measurement method developed for Euclid and Stage-IV surveys. It is based on forward modelling to deal with convolution by a point spread function with comparable size to many galaxies; sampling the posterior distribution of galaxy parameters via Markov Chain Monte Carlo; and marginalisation over nuisance parameters for each of the 1.5 billion galaxies observed by Euclid. The scientific performance is quantified through high-fidelity images based on the Euclid Flagship simulations and emulation of the Euclid VIS images; realistic clustering with a mean surface number density of 250 arcmin$^{-2}$ ($I_{\rm E}<29.5$) for galaxies, and 6 arcmin$^{-2}$ ($I_{\rm E}<26$) for stars; and a diffraction-limited chromatic point spread function with a full width at half maximum of $0.^{\!\prime\prime}2$ and spatial variation across the field of view. Objects are measured with a density of 90 arcmin$^{-2}$ ($I_{\rm E}<26.5$) in 4500 deg$^2$. The total shear bias is broken down into measurement (our main focus here) and selection effects (which will be addressed elsewhere). We find: measurement multiplicative and additive biases of $m_1=(-3.6\pm0.2)\times10^{-3}$, $m_2=(-4.3\pm0.2)\times10^{-3}$, $c_1=(-1.78\pm0.03)\times10^{-4}$, $c_2=(0.09\pm0.03)\times10^{-4}$; a large detection bias with a multiplicative component of $1.2\times10^{-2}$ and an additive component of $-3\times10^{-4}$; and a measurement PSF leakage of $α_1=(-9\pm3)\times10^{-4}$ and $α_2=(2\pm3)\times10^{-4}$. When model bias is suppressed, the obtained measurement biases are close to Euclid requirement and largely dominated by undetected faint galaxies ($-5\times10^{-3}$). Although significant, model bias will be straightforward to calibrate given the weak sensitivity.
△ Less
Submitted 1 May, 2024;
originally announced May 2024.
Voluntary phantom hand and finger movements in transhumeral amputees could be used to naturally control polydigital prostheses
Authors:
Nathanael Jarrasse,
Caroline Nicol,
Florian Richer,
Amelie Touillet,
Noël Martinet,
Jean Paysant,
Jozina de Graaf
Abstract:
An arm amputation is extremely invalidating since many of our daily tasks require bi-manual and precise control of hand movements. Perfect hand prostheses should therefore offer a natural, intuitive and cognitively simple control over their numerous biomimetic active degrees of freedom. While efficient polydigital prostheses are commercially available, their control remains complex to master and o…
▽ More
An arm amputation is extremely invalidating since many of our daily tasks require bi-manual and precise control of hand movements. Perfect hand prostheses should therefore offer a natural, intuitive and cognitively simple control over their numerous biomimetic active degrees of freedom. While efficient polydigital prostheses are commercially available, their control remains complex to master and offers limited possibilities, especially for high amputation levels. In this pilot study, we demonstrate the possibility for upper-arm amputees to intuitively control a polydigital hand prosthesis by using surface myoelectric activities of residual limb muscles (sEMG) associated with phantom limb movements, even if these residual arm muscles on which the phantom activity is measured were not naturally associated with hand movements before amputation. Using pattern recognition methods, three arm amputees were able, without training, to initiate 5-8 movements of a robotic hand (including individual finger movements) by simply mobilizing their phantom limb while the robotic hand was mimicking the action in real time. This innovative control approach could offer to numerous upper-limb amputees an access to recent biomimetic prostheses with multiple controllable joints, without requiring surgery or complex training; and might deeply change the way the phantom limb is apprehended by both patients and clinicians.
△ Less
Submitted 26 April, 2019;
originally announced April 2019.