Unfolding of sparse high-energy $γ$-ray spectra from LaBr$_{3}$:Ce detectors
Authors:
P. -A. Söderström,
L. Capponi,
V. Iancu,
D. Lattuada,
A. Pappalardo,
G. V. Turturică,
E. Açıksöz,
D. L. Balabanski,
P. Constantin,
G. L. Guardo,
M. Ilie,
S. Ilie,
C. Matei,
D. Nichita,
T. Petruse,
A. Spataru
Abstract:
Here we report on the characterization of one of the large-volume LaBr$_{3}$:Ce detectors for the ELIGANT project at ELI-NP. The main focus of this work is the response function for high-energy $γ$ rays of such detectors. In particular, we compare a selection of unfolding methods to resolve small structures in $γ$-ray spectra with high-energies. Three methods have been compared using $γ$-ray spect…
▽ More
Here we report on the characterization of one of the large-volume LaBr$_{3}$:Ce detectors for the ELIGANT project at ELI-NP. The main focus of this work is the response function for high-energy $γ$ rays of such detectors. In particular, we compare a selection of unfolding methods to resolve small structures in $γ$-ray spectra with high-energies. Three methods have been compared using $γ$-ray spectra with energies up to 12 MeV obtained in an experiment at the 3 MV Tandetron\texttrademark\ facility at IFIN-HH. The results show that the iterative unfolding approach gives the best qualitative reproduction of the emitted $γ$-ray spectrum. Furthermore, the correlation fluctuations in high-energy regime from the iterative method are two orders of magnitude smaller than when using the matrix inversion approach with second derivative regularization. In addition, the iterative method is computationally faster as it does not contain large matrix inversions. The matrix inversion method does, however, give more consistent results over the full energy range and in the low-statistics limit. Our conclusion is that the performance of the iterative approach makes it well suitable for semi-online analysis of experimental data. These results will be important, both for experiments with the ELIGANT setup, and for on-line diagnostics of the energy spread of the $γ$-ray beam which is under implementation at ELI-NP.
△ Less
Submitted 16 October, 2019;
originally announced October 2019.
Time Projection Chamber (TPC) Detectors for Nuclear Astrophysics Studies With Gamma Beams
Authors:
M. Gai,
D. Schweitzer,
S. R. Stern,
A. H. Young,
R. Smith,
M. Cwiok,
J. S. Bihalowicz,
H. Czyrkowski,
R. Dabrowski,
W. Dominik,
A. Fijalkowska,
Z. Janas,
L. Janiak,
A. Korgul,
T. Matulewicz,
C. Mazzocchi,
M. Pfuetzner,
M. Zaremba,
D. Balabanski,
I. Gheorghe,
C. Matei,
O. Tesileanu,
N. V. Zamfir,
M. W. Ahmed,
S. S. Henshaw
, et al. (11 additional authors not shown)
Abstract:
Gamma-Beams at the HIgS facility in the USA and anticipated at the ELI-NP facility, now constructed in Romania, present unique new opportunities to advance research in nuclear astrophysics; not the least of which is resolving open questions in oxygen formation during stellar helium burning via a precise measurement of the 12C(a,g) reaction. Time projection chamber (TPC) detectors operating with lo…
▽ More
Gamma-Beams at the HIgS facility in the USA and anticipated at the ELI-NP facility, now constructed in Romania, present unique new opportunities to advance research in nuclear astrophysics; not the least of which is resolving open questions in oxygen formation during stellar helium burning via a precise measurement of the 12C(a,g) reaction. Time projection chamber (TPC) detectors operating with low pressure gas (as an active target) are ideally suited for such studies. We review the progress of the current research program and plans for the future at the HIγS facility with the optical readout TPC (O-TPC) and the development of an electronic readout TPC for the ELI-NP facility (ELITPC).
△ Less
Submitted 22 December, 2018;
originally announced December 2018.