-
Lost options commitment: how short-term policies affect long-term scope of action
Authors:
Marina Martinez Montero,
Nuria Brede,
Victor Couplet,
Michel Crucifix,
Nicola Botta,
Claudia Wieners
Abstract:
We propose to explore the sustainability of climate policies based on a novel commitment metric. This metric allows to quantify how future generations' scope of action is affected by short-term climate policy. In an example application, we show that following a moderate emission scenario like SSP2-4.5 could commit future generations to heavily rely on carbon dioxide removal or/and solar radiation…
▽ More
We propose to explore the sustainability of climate policies based on a novel commitment metric. This metric allows to quantify how future generations' scope of action is affected by short-term climate policy. In an example application, we show that following a moderate emission scenario like SSP2-4.5 could commit future generations to heavily rely on carbon dioxide removal or/and solar radiation modification to avoid unmanageable sea level rise.
△ Less
Submitted 14 September, 2023;
originally announced September 2023.
-
Searching for millicharged particles with 1 kg of Skipper-CCDs using the NuMI beam at Fermilab
Authors:
Santiago Perez,
Dario Rodrigues,
Juan Estrada,
Roni Harnik,
Zhen Liu,
Brenda A. Cervantes-Vergara,
Juan Carlos D'Olivo,
Ryan D. Plestid,
Javier Tiffenberg,
Tien-Tien Yu,
Alexis Aguilar-Arevalo,
Fabricio Alcalde-Bessia,
Nicolas Avalos,
Oscar Baez,
Daniel Baxter,
Xavier Bertou,
Carla Bonifazi,
Ana Botti,
Gustavo Cancelo,
Nuria Castelló-Mor,
Alvaro E. Chavarria,
Claudio R. Chavez,
Fernando Chierchie,
Juan Manuel De Egea,
Cyrus Dreyer
, et al. (35 additional authors not shown)
Abstract:
Oscura is a planned light-dark matter search experiment using Skipper-CCDs with a total active mass of 10 kg. As part of the detector development, the collaboration plans to build the Oscura Integration Test (OIT), an engineering test with 10% of the total mass. Here we discuss the early science opportunities with the OIT to search for millicharged particles (mCPs) using the NuMI beam at Fermilab.…
▽ More
Oscura is a planned light-dark matter search experiment using Skipper-CCDs with a total active mass of 10 kg. As part of the detector development, the collaboration plans to build the Oscura Integration Test (OIT), an engineering test with 10% of the total mass. Here we discuss the early science opportunities with the OIT to search for millicharged particles (mCPs) using the NuMI beam at Fermilab. mCPs would be produced at low energies through photon-mediated processes from decays of scalar, pseudoscalar, and vector mesons, or direct Drell-Yan productions. Estimates show that the OIT would be a world-leading probe for mCPs in the MeV mass range.
△ Less
Submitted 2 December, 2023; v1 submitted 17 April, 2023;
originally announced April 2023.
-
Skipper-CCD Sensors for the Oscura Experiment: Requirements and Preliminary Tests
Authors:
Brenda A. Cervantes-Vergara,
Santiago Perez,
Juan Estrada,
Ana Botti,
Claudio R. Chavez,
Fernando Chierchie,
Nathan Saffold,
Alexis Aguilar-Arevalo,
Fabricio Alcalde-Bessia,
Nicolás Avalos,
Oscar Baez,
Daniel Baxter,
Xavier Bertou,
Carla Bonifazi,
Gustavo Cancelo,
Nuria Castelló-Mor,
Alvaro E. Chavarria,
Juan Manuel De Egea,
Juan Carlos D'Olivo,
Cyrus Dreyer,
Alex Drlica-Wagner,
Rouven Essig,
Ezequiel Estrada,
Erez Etzion,
Paul Grylls
, et al. (30 additional authors not shown)
Abstract:
Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2-10 electron ionization-signal…
▽ More
Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2-10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru. In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.
△ Less
Submitted 11 April, 2024; v1 submitted 10 April, 2023;
originally announced April 2023.
-
Volume reduction of water samples to increase sensitivity for radioassay of lead contamination
Authors:
A. Aguilar-Arevalo,
C. Canet,
M. A. Cruz-Pérez,
A. Deisting,
A. Dias,
J. C. D'Olivo,
F. Favela-Pérez,
E. A. Garcés,
A. González Muñoz,
J. O. Guerra-Pulido,
J. Mancera-Alejandrez,
D. J. Marín-Lámbarri,
M. Martinez Montero,
J. R. Monroe,
S. Paling,
S. J. M. Peeters,
P. R. Scovell,
C. Türkoğlu,
E. Vázquez-Jáuregui,
J. Walding
Abstract:
The World Health Organisation (WHO) presents an upper limit for lead in drinking water of 10 parts per billion ppb. Typically, to reach this level of sensitivity, expensive metrology is required. To increase the sensitivity of low cost devices, this paper explores the prospects of using a volume reduction technique of a boiled water sample doped with Lead-210 ($^{210}Pb$), as a means to increase t…
▽ More
The World Health Organisation (WHO) presents an upper limit for lead in drinking water of 10 parts per billion ppb. Typically, to reach this level of sensitivity, expensive metrology is required. To increase the sensitivity of low cost devices, this paper explores the prospects of using a volume reduction technique of a boiled water sample doped with Lead-210 ($^{210}Pb$), as a means to increase the solute's concentration. $^{210}$Pb is a radioactive lead isotope and its concentration in a water sample can be measured with e.g. High Purity Germanium (HPGe) detectors at the Boulby Underground Germanium Suite. Concentrations close to the WHO limit have not been examined. This paper presents a measurement of the volume reduction technique retaining $99\pm(9)\%$ of $^{210}$Pb starting from a concentration of $1.9\times10^{-6}$ ppb before reduction and resulting in $2.63\times10^{-4}$ ppb after reduction. This work also applies the volume reduction technique to London tap water and reports the radioassay results from gamma counting in HPGe detectors. Among other radio-isotopes, $^{40}$K, $^{210}$Pb, $^{131}$I and $^{177}$Lu were identified at measured concentrations of $2.83\times10^{3}$ ppb, $2.55\times10^{-7}$ ppb, $5.06\times10^{-10}$ ppb and $5.84\times10^{-10}$ ppb in the London tap water sample. This technique retained $90\pm50\%$ of $^{40}$K. Stable lead was inferred from the same water sample at a measured concentration of 0.012 ppb, prior to reduction.
△ Less
Submitted 9 May, 2022;
originally announced May 2022.
-
PlomBOX -- development of a low-cost CMOS device for environmental monitoring
Authors:
A. Aguilar-Arevalo,
E. Alba Posse,
M. Alvarez,
H. Arnaldi,
H. Asorey,
X. Bertou,
A. Colque,
A. Deisting,
A. Dias,
J. C. D'Olivo,
F. Favela-Pérez,
Y. Gándola,
E. A. Garcés,
J. Gasulla,
M. Gómez Berisso,
A. González Muñoz,
J. O. Guerra-Pulido,
S. Gutierrez,
S. Jois,
J. Lipovetzky,
J. Lovera,
M. B. Lovino,
D. J. Marín-Lámbarri,
L. Marpegan,
D. Martín
, et al. (14 additional authors not shown)
Abstract:
This paper reports on the development of a novel CMOS device employing lead-sensing bacteria to assay lead in drinking water. The objective of the PlomBOX project is to develop a low-cost sensor (£10) which can expedite access to on-demand assay methods and thus help mitigate lead intake through contaminated drinking water. The project follows three development paths: a) Certain bacteria can fluor…
▽ More
This paper reports on the development of a novel CMOS device employing lead-sensing bacteria to assay lead in drinking water. The objective of the PlomBOX project is to develop a low-cost sensor (£10) which can expedite access to on-demand assay methods and thus help mitigate lead intake through contaminated drinking water. The project follows three development paths: a) Certain bacteria can fluoresce or change colour when in the presence of lead. A genetically modified strain of Escherichia coli sensitive to lead concentrations up to 10 ppb is being developed. This constitutes the biosensor that fluoresces in proportion to the presence of lead. b) Bacteria response is imaged using a microprocessor (ESP32) with a camera module. This constitutes the optical metrology component of the PlomBOX. c) Data acquisition and control of the PlomBOX is achieved through a Bluetooth connection with the PlomApp, a custom-developed mobile phone application. Data are sent from the PlomApp to a database where a bespoke automated analysis software provides a result of the lead concentration in a sample of water. This paper reports on the instrumentation challenges of developing the electronics for the PlomBOX and on the first prototype.
△ Less
Submitted 10 January, 2022;
originally announced January 2022.
-
Search for coherent elastic neutrino-nucleus scattering at a nuclear reactor with CONNIE 2019 data
Authors:
CONNIE collaboration,
Alexis Aguilar-Arevalo,
Javier Bernal,
Xavier Bertou,
Carla Bonifazi,
Gustavo Cancelo,
Victor G. P. B. de Carvalho,
Brenda A. Cervantes-Vergara,
Claudio Chavez,
Gustavo Coelho Corrêa,
Juan C. D'Olivo,
João C. dos Anjos,
Juan Estrada,
Aldo R. Fernandes Neto,
Guillermo Fernandez Moroni,
Ana Foguel,
Richard Ford,
Julián Gasanego Barbuscio,
Juan Gonzalez Cuevas,
Susana Hernandez,
Federico Izraelevitch,
Ben Kilminster,
Kevin Kuk,
Herman P. Lima Jr,
Martin Makler
, et al. (11 additional authors not shown)
Abstract:
The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) is taking data at the Angra 2 nuclear reactor with the aim of detecting the coherent elastic scattering of reactor antineutrinos with silicon nuclei using charge-coupled devices (CCDs). In 2019 the experiment operated with a hardware binning applied to the readout stage, leading to lower levels of readout noise and improving the detecti…
▽ More
The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) is taking data at the Angra 2 nuclear reactor with the aim of detecting the coherent elastic scattering of reactor antineutrinos with silicon nuclei using charge-coupled devices (CCDs). In 2019 the experiment operated with a hardware binning applied to the readout stage, leading to lower levels of readout noise and improving the detection threshold down to 50 eV. The results of the analysis of 2019 data are reported here, corresponding to the detector array of 8 CCDs with a fiducial mass of 36.2 g and a total exposure of 2.2 kg-days. The difference between the reactor-on and reactor-off spectra shows no excess at low energies and yields upper limits at 95% confidence level for the neutrino interaction rates. In the lowest-energy range, 50-180 eV, the expected limit stands at 34 (39) times the standard model prediction, while the observed limit is 66 (75) times the standard model prediction with Sarkis (Chavarria) quenching factors.
△ Less
Submitted 6 April, 2022; v1 submitted 25 October, 2021;
originally announced October 2021.
-
Characterization of Germanium Detectors for the First Underground Laboratory in Mexico
Authors:
A. Aguilar-Arevalo,
S. Alvarado-Mijangos,
X. Bertou,
C. Canet,
M. A. Cruz-Pérez,
A. Deisting,
A. Dias,
J. C. D'Olivo,
F. Favela-Pérez,
E. A. Garcés,
A. González Muñoz,
J. O. Guerra-Pulido,
J. Mancera-Alejandrez,
D. J. Marín-Lámbarri,
M. Martínez Montero,
J. Monroe,
C. Iván Ortega-Hernández,
S. Paling,
S. Peeters,
D. Ruíz Esparza Rodríguez,
P. R. Scovell,
C. Türkoğlu,
E. Vázquez-Jáuregui,
J. Walding
Abstract:
This article reports the characterization of two High Purity Germanium detectors performed by extracting and comparing their efficiencies using experimental data and Monte Carlo simulations. The efficiencies were calculated for pointlike $γ$-ray sources as well as for extended calibration sources. Characteristics of the detectors such as energy linearity, energy resolution, and full energy peak ef…
▽ More
This article reports the characterization of two High Purity Germanium detectors performed by extracting and comparing their efficiencies using experimental data and Monte Carlo simulations. The efficiencies were calculated for pointlike $γ$-ray sources as well as for extended calibration sources. Characteristics of the detectors such as energy linearity, energy resolution, and full energy peak efficiencies are reported from measurements performed on surface laboratories. The detectors will be deployed in a $γ$-ray assay facility that will be located in the first underground laboratory in Mexico, Laboratorio Subterráneo de Mineral del Chico (LABChico), in the Comarca Minera UNESCO Global Geopark
△ Less
Submitted 24 September, 2020;
originally announced September 2020.
-
Dosimetry and calorimetry performance of a scientific CMOS camera for environmental monitoring
Authors:
Alexis Aguilar-Arevalo,
Xavier Bertou,
Carles Canet,
Miguel Angel Cruz-Perez,
Alexander Deisting,
Adriana Dias,
Juan Carlos D'Olivo,
Francisco Favela-Perez,
Estela A. Garces,
Adiv Gonzalez Munoz,
Jaime Octavio Guerra-Pulido,
Javier Mancera-Alejandrez,
Daniel Jose Marin-Lambarri,
Mauricio Martinez Montero,
Jocelyn Monroe,
Sean Paling,
Simon J. M. Peeters,
Paul Scovell,
Cenk Turkoglu,
Eric Vazquez-Jauregui,
Joseph Walding
Abstract:
This paper explores the prospect of CMOS devices to assay lead in drinking water, using calorimetry. Lead occurs together with traces of radioisotopes, e.g. Lead-210, producing $γ$-emissions with energies ranging from 10 keV to several 100 keV when they decay; this range is detectable in silicon sensors. In this paper we test a CMOS camera (Oxford Instruments Neo 5.5) for its general performance a…
▽ More
This paper explores the prospect of CMOS devices to assay lead in drinking water, using calorimetry. Lead occurs together with traces of radioisotopes, e.g. Lead-210, producing $γ$-emissions with energies ranging from 10 keV to several 100 keV when they decay; this range is detectable in silicon sensors. In this paper we test a CMOS camera (Oxford Instruments Neo 5.5) for its general performance as a detector of x-rays and low energy $γ$-rays and assess its sensitivity relative to the World Health Organization upper limit on lead in drinking water. Energies from 6 keV to 60 keV are examined. The CMOS camera has a linear energy response over this range and its energy resolution is for the most part slightly better than 2 %. The Neo sCMOS is not sensitive to x-rays with energies below $\sim\!\!10 keV$. The smallest detectable rate is 40$\pm$3 mHz, corresponding to an incident activity on the chip of 7$\pm$4 Bq. The estimation of the incident activity sensitivity from the detected activity relies on geometric acceptance and the measured efficiency vs. energy. We report the efficiency measurement, which is 0.08$\pm$0.02 % (0.0011$\pm$0.0002 %) at 26.3 keV (59.5 keV). Taking calorimetric information into account we measure a minimal detectable rate of 4$\pm$1 mHz (1.5$\pm$0.1 mHz) for 26.3 keV (59.5 keV) $γ$-rays, which corresponds to an incident activity of 1.0$\pm$0.6 Bq (57$\pm$33 Bq). Toy Monte Carlo and Geant4 simulations agree with these results. These results show this CMOS sensor is well-suited as a $γ$- and x-ray detector with sensitivity at the few to 100 ppb level for Lead-210 in a sample.
△ Less
Submitted 23 September, 2020;
originally announced September 2020.