-
Trajectory Deflection of Spinning Magnetic Microparticles, the Magnus Effect at the Microscale
Authors:
M. Solsona,
H. Keizer,
H. de Boer,
Y. P. Klein,
W. Olthuis,
L. Abelmann,
A. van den Berg
Abstract:
The deflection due to the Magnus force of magnetic particles with a diameter of 80 micrometer dropping through fluids and rotating in a magnetic field was measured. With Reynolds number for this experiment around 1, we found trajectory deflections of the order of 1 degree, in agreement within measurement error with theory. This method holds promise for the sorting and analysis of the distribution…
▽ More
The deflection due to the Magnus force of magnetic particles with a diameter of 80 micrometer dropping through fluids and rotating in a magnetic field was measured. With Reynolds number for this experiment around 1, we found trajectory deflections of the order of 1 degree, in agreement within measurement error with theory. This method holds promise for the sorting and analysis of the distribution in magnetic moment and particle diameter of suspensions of microparticles, such as applied in catalysis, or objects loaded with magnetic particles.
△ Less
Submitted 29 April, 2020;
originally announced April 2020.
-
Miniaturised control of acidity in multiplexed microreactors
Authors:
Divya Balakrishnan,
Wouter Olthuis,
César Pascual-García
Abstract:
The control of acidity influences the structural assembly of biopolymers that are essential for a wide range of applications. Its miniaturization can increase the speed and the possibilities of combinatorial throughput for their manipulation, similarly to the way that the miniaturization of transistors allows the high throughput of logical operations in microelectronics. Here we present a device c…
▽ More
The control of acidity influences the structural assembly of biopolymers that are essential for a wide range of applications. Its miniaturization can increase the speed and the possibilities of combinatorial throughput for their manipulation, similarly to the way that the miniaturization of transistors allows the high throughput of logical operations in microelectronics. Here we present a device containing multiplexed micro-reactors, each one enabling independent electrochemical control of the acidity in ~ 2.5 nL volumes, with a large acidity range in aqueous solutions from pH 3 to 7 and an accuracy of at least 0.4 pH units. The attained pH within each microreactor (with footprints of ~ 0.3 mm2 for each spot) was kept constant for long retention times (~10 minutes) and over repeated cycles >100. The acidity is driven by redox proton exchange reactions, which can be driven at different rates that influence the efficiency of the device in order to achieve more charge exchange (larger acidity range) or better reversibility. By the performance in the acidity control the miniaturisation and the possibility to multiplex paves the way for the control of combinatorial chemistry through pH and acidity controlled reactions.
△ Less
Submitted 7 August, 2019;
originally announced August 2019.
-
High Performance Fin-FET electrochemical sensor with high-k dielectric materials
Authors:
Serena Rollo,
Dipti Rani,
Wouter Olthuis,
César Pascual García
Abstract:
In this work we combine a Fin Field Effect Transistor (Fin-FET) characterised by a high height to width aspect ratio with high-k dielectric materials to study the optimized design for chemical-FETs to provide higher transconductance (and thus a better signal to noise ratio), increased dynamic range and chemical stability. We used pH sensing to verify the design. We explored the sensitivity and res…
▽ More
In this work we combine a Fin Field Effect Transistor (Fin-FET) characterised by a high height to width aspect ratio with high-k dielectric materials to study the optimized design for chemical-FETs to provide higher transconductance (and thus a better signal to noise ratio), increased dynamic range and chemical stability. We used pH sensing to verify the design. We explored the sensitivity and response linearity of silicon dioxide, alumina and hafnium oxide as dielectric materials sensing pH, and compared their chemical stability in different acids. The high aspect ratio fin geometry of the sensor provides high currents, as well as a planar conduction channel more reliable than traditional silicon nanowires. The hafnium oxide Fin-FET configuration performed the best delivering the most linear response both for the output and transfer characteristics providing a wider dynamic range. Hafnium oxide also showed the best chemical stability. Thus, we believe that the developed high aspect ratio Fin-FETs/high-k dielectric system can offer the best compromise of performance of FET-based sensors.
△ Less
Submitted 25 July, 2019;
originally announced July 2019.
-
A high aspect ratio Fin-Ion Sensitive Field Effect Transistor: compromises towards better electrochemical bio-sensing
Authors:
Serena Rollo,
Dipti Rani,
Renaud Leturcq,
Wouter Olthuis,
César Pascual García
Abstract:
The development of next generation medicines demand more sensitive and reliable label free sensing able to cope with increasing needs of multiplexing and shorter times to results. Field effect transistor-based biosensors emerge as one of the main possible technologies to cover the existing gap. The general trend for the sensors has been miniaturisation with the expectation of improving sensitivity…
▽ More
The development of next generation medicines demand more sensitive and reliable label free sensing able to cope with increasing needs of multiplexing and shorter times to results. Field effect transistor-based biosensors emerge as one of the main possible technologies to cover the existing gap. The general trend for the sensors has been miniaturisation with the expectation of improving sensitivity and response time, but presenting issues with reproducibility and noise level. Here we propose a Fin-Field Effect Transistor (FinFET) with a high heigth to width aspect ratio for electrochemical biosensing solving the issue of nanosensors in terms of reproducibility and noise, while keeping the fast response time. We fabricated different devices and characterised their performance with their response to the pH changes that fitted to a Nernst-Poisson model. The experimental data were compared with simulations of devices with different aspect ratio, stablishing an advantage in total signal and linearity for the FinFETs with higher aspect ratio. In addition, these FinFETs promise the optimisation of reliability and efficiency in terms of limits of detection, for which the interplay of the size and geometry of the sensor with the diffusion of the analytes plays a pivotal role.
△ Less
Submitted 8 January, 2019;
originally announced January 2019.